Crude oil, which exported to refineries, already contains salt, water, and fouling crude oil received with salt content not less than 50 ppm. Dewania refinery with a capacity of 20,000 BPSD, which serves with two crude distillation units, each unit with a capacity of 10,000 BPSD, which operate without crude desalter. In an aim to reduce the effects of salts, water and, fouling associated with crude oil, two crude distillation units connected with one crude oil desalter with a capacity of 20,000 BPSD (one desalter). crude oil desalter transferred from (Daura Refinery) to Dewania refinery, in aim to reduce salt content from 50ppm to 5 ppm and mitigate water and other fouling. Crude oil desalter installed in the middle distance between two crude distillations units (90 m from each unit isometric piping). Crude oil, which is pumped by a charge pump to preheated in crude oil distillation unit with a train of heat exchangers. When the pipeline size increased from 4″ to 6″, which reduces the pressure dropped from 0.946 to 0.15 bar for each transfer pipeline and in consequence, the total pressure drop reduces from 11.011 to 10.215 bar for the whole unit. In an aim to reduce the heat dissipated from surface of transfer pipeline. Each transfer pipeline insulated with calcium silicate insulator, the thickness of insulator increased from 38mm to 50mm in an aim to reduce heat loss from −101.56 watts/m to −84.282 watts/m, which reduced temperature difference between the surface pipeline and environment from 13 to 10°C.
Part of the book: Crude Oil
Daura refinery, with a capacity of 140,000 barrel per stream day as a refining capacity, wastewater discharged from refining and treatment processing units, polluted water as foul water, drainages, oil spills, blowdown of boilers and cooling towers, and many other polluted water sources, aims to remove pollutants and reject clean water to the river; wastewater treatment system takes place in this treatment process. Wastewater treatment system suffers from many problems and specifically biological stage; at this stage, activated sludge with bacteria, should be supplied with oxygen, aeration system done by surface aerators with four surface fans; these fans suffer from high vibration, loss support, and in consequence, lack in oxygen supply to aerobic bacteria less than 4 ppm. The nonporous aerator is suggested as an oxygen source for the biological pool. The pilot plant builds the aim to study the ability to apply the new aeration system at the biological pool, pilot plant build with 1 cubic meter capacity tank and continuous overflow of wastewater of 10 liters.min−1, air injected with the pressure of (0.5–0.75) bar(g), and airflow of (7.6–9.7) liter.min−1 respectively. Oxygen concentration was recorded as (3.4–6.0) ppm; in terms of consumption power, changing the aeration system reduces it to less than 20%.
Part of the book: Wastewater Treatment