Types and features of papers used in biosensors described recently.
Abstract
The presence of contaminants in water generates a great concern worldwide. As contaminants, we can refer different classes of chemicals, such as pharmaceuticals, personal care products, heavy metals, and also microorganisms, such as waterborne pathogens. Some of the chemical compounds have the potential to bioaccumulate in the aquatic biota. Hence, the development of simple and portable methods for the detection of contaminants in the aquatic environment can improve their monitoring and, consequently, the study of their environmental impact. In this context, the development of paper-based analytical tools and also of biosensor devices has been exploited for quantitative and semiquantitative analysis of several contaminants in different water matrices. The association of these two analytical strategies can provide the implementation of low-cost, portable, and easily handled methods for detecting chemical and biological contaminations in water. In this chapter, we provide a review of the developed paper-based analytical biosensors, highlighting the features of the paper-based (paper substrate and fabrication procedures) and biosensor devices (transducers and biorecognition elements). Moreover, the application of the referred paper-based biosensors for the detection of different water contaminants (pathogens, pharmaceuticals, and heavy metals) in environmental and wastewater samples is discussed.
Keywords
- microfluidic
- paper-based devices
- water analysis
- water contaminants
- biosensing
1. Introduction
The contamination of the different water compartments with several chemicals and by-products has become a major concern for human health and aquatic biota [1, 2, 3]. The environmental contaminants of major concern are pharmaceuticals, personal care products, pesticides and herbicides, heavy metals, and waterborne pathogens. Some of the chemical compounds are persistent to degradation and, therefore, can accumulate in aquatic organisms and sediments. Thus, the monitoring of contaminants in the aquatic environment is crucial to study their impact [4].
Currently, there is no regulation about the allowed levels of pharmaceutical compounds, including ethinylestradiol and antibiotics, in water. Concerning the maximum contaminant levels (MCL) in drinking water for the target metals presented in this work, their MCL are between 2 and 30 μg L−1, according to the chemical species [5, 6]. Arsenic presents an MCL value of 10 μg L−1 [5, 6], while the MCL value for mercury is 2 or 6 μg L−1 according to United States Environmental Protection Agency (EPA) and World Health Organization (WHO), respectively. Moreover, the MCL for lead is 15 [5] and 10 μg L−1 [6]. Uranium presents the higher MCL, which is 30 μg L−1 [5, 6]. Cadmium’s maximum contaminant level corresponds to 3 and 5 μg L−1 according to WHO and EPA, respectively. With respect to the pathogens targeted in the paper-based biosensors, the EPA [7] recommends that
In this context, paper-based biosensor devices combine the main features of paper substrates (cost-effectiveness, easy manipulation, and compatibility with proteins and biomolecules), with the high specificity and selectivity of the biorecognition systems of biosensors [1, 8, 9]. Furthermore, paper-based assays can be a solution in resource-limited contexts, as both sample and reagents can be introduced without any flow device, through imbibition and filtration via capillary action [10].
The first types of paper-based devices were related to semiquantitative analysis of glucose in urine and immunoassays on chromatographic paper test strips (or lateral flow) [11]. In the last decade, a new fabrication method based on wax patterning was introduced, allowing the design of well-defined channels on paper surface, which provided microfluidic features to the paper-based devices [12].
Reviews concerning the application of paper-based devices in different fields such as food, water analysis, environmental monitoring, and health diagnostics are available [8, 11, 13]. Furthermore, the application of biosensors has been extensively discussed regarding both their usefulness on assessing environmental and urban pollutants [1], and also their role as part of portable biochemical detection systems [14]. However, gathering information about the implementation of paper-based techniques coupled with biosensor devices to water analysis is still lacking. Hence, the aim of this work is to provide a description of the state of the art about the development and application of paper-based analytical biosensors to detect contaminants in water, focusing on work developed in the last 3 years.
2. Paper-based analytical devices
2.1 Substrate material
Paper is a complex material and a promising support for the development of biosensor analytical devices. Its main features, such as versatility, low-cost, and biocompatibility, generate simple and disposable bioanalytical tools using low reagent consumption (in the order of microliters) [8, 11, 12]. Paper is mainly constituted of cellulose fibers. The cellulose is a hydrophilic polymer, which makes paper substrate permeable to aqueous liquids [15].
There are different types of paper that are used for fabrication of paper-based devices (Table 1). Filter papers have been widely used as substrate material to paper-based devices for biosensor application [16, 17, 18, 19]. There are a vast range of commercially available high-quality filter papers, mainly constituted of alpha cellulose, a highly stable form of cellulose. The filter papers can be classified according to different properties, such as particle retention, pore size, thickness, and flow rate.
Type of paper | Examples | Features |
---|---|---|
Cellulose filter paper | Whatman® filter paper grades 1 and 2 | Hydrophilic polymer, permeable to aqueous liquids; available with different pore sizes and thickness |
Cellulose chromatography paper | Whatman® chromatographic paper grades 1, and 2 | Allows the concentration of nanostructures in its surface and the separation of nanoparticles in agglutination-based assays |
Nitrocellulose membrane | Millipore Hi-Flow Plus HF240 | Hydrophobic polymer; adequate for immobilization of complex biological structures by electrostatic interactions |
Printing paper | Fabriano 5 HP paper, Boise®Aspen® 30 multiuse recycled copy paper | 3D structures can be easily printed in its surface, providing microchannels or screen-printed electrodes |
The filter paper grade 1, considered as a medium retention and flow filter paper, has been functionalized to obtain paper-based immunosensors [16, 17]. Irvine et al. adsorbed metallothioneins in grade 1 filter paper for the detection of heavy metals [18]. In the same way, other filter paper grades have been used, such as the slow filter paper grade 42 (pore size of 2.5 μm) for the incorporation of an in vitro transcription/translation system [19].
Cellulose chromatography paper is also an alternative as high-quality substrate in paper-based biosensors. These papers can be differentiated by their flow rate and thickness. Vijitvarasan et al. [20] developed a paper-based device taking in advantage of the separative properties of chromatographic paper in order to enhance the concentration of gold nanoparticles (AuNPs) on the surface of the paper. Thus, a lower level of reduced silver particles was detected on the surface of AuNPs. Chromatography papers have also been applied in the development of microfluidic devices based on capillary flow measurement [21, 22]. McCraken et al. [22] tested two different chromatography papers (grade 1 Chr and grade 2 Chr) to optimize the separation of immunoagglutinated particles. The chromatography paper providing the lower flow rate (grade 2, 115 mm/30 min) was selected for the immunoagglutination assay.
Derivatives of cellulose, such as nitrocellulose membranes, have been applied as substrates of paper-based devices. These membranes are naturally hydrophobic and demonstrate to be adequate for the immobilization of enzymes and proteins by electrostatic interactions [11]. For instance, Lopez-Marzo et al. [23] developed a lateral flow immunodevice with nitrocellulose membrane for the detection of Cd2+ in water, taking advantage of the immobilization of antibodies (2A81G5 mouse antibody and antibovine serum albumin (BSA) mouse antibody), to create zones where the probe conjugate and the positive control containing BSA would interact. A similar approach was reported for immobilization of BSA conjugate and control goat antimouse immunoglobulin for the detection of U(VI) [24].
Concerning electrochemical paper-based devices, printing paper can be applied in the development of screen-printed electrodes. Hence, carbon-based conductive ink is printed onto paper surface [25, 26]. In this context, Rengaraj et al. [27] fabricated a paper-based electrode with the high-quality printing paper using only three layers of printing.
In addition, both chromatographic paper and multiuse recycled copy paper were used for printing wax wells in paper-based devices as a confinement strategy [20], or as a low-cost alternative to microplates [28].
2.2 Fabrication procedures
There are different techniques that can be applied in order to obtain paper-based biosensor devices with variable properties, such as functionalized platforms with biomolecules or cell suspensions, conductive characteristics for electrochemical analysis, and create barriers to define the reaction zones.
Wax printing is a process used to create hydrophobic barriers that define reaction microzones or fluid reservoirs [29], as exemplified in Figure 1. Different works [16, 17, 20, 22, 28] applied this technique using graphic design software [16, 17, 22] or stencils [28] to define the microchannel areas. The incorporation of the wax onto the microfluidic channel is performed by printing the wax onto the paper surface with subsequent heating to allow wax penetration in the paper.
Screen printing is another technique used to fabricate paper-based devices, particularly for electrochemical analysis (Figure 1B). For example, Rengaraj et al. [27] fabricated a paper-based electrode by printing three layers of a carbon-based conductive ink onto hydrophobic printer paper. Other fabrication techniques include a simple procedure of cutting by punching [18, 19], obtaining discs with millimetric dimensions that can be functionalized and/or introduced into devices, such as commercial screen-printed electrodes [18].
Furthermore, lateral flow immune-based devices can be fabricated by assembling different layers, which include the conjugation of pad strip (signal producer), the nitrocellulose membrane, as well as the sample and absorption pad [23, 24]. Stocker et al. [30] applied a simple technique based on premarking the spots with a pencil, with subsequent physical deposition of a cell suspension and drying of the paper strips.
3. Integrated biosensors methods
3.1 Transducers
Biosensors can be defined as analytical devices, which integrate or associate a biorecognition element and a transducer. The bioelement recognizes the target analyte and the transducer converts the biochemical interaction to a measurable signal [1]. The most frequently applied transducers are based on optical, electrochemical, thermal, and piezoelectric properties. This work focused on the transducer types most used in the paper-based biosensors for analysis of water (electrochemical, optical, and piezoelectric).
The electrochemical paper-based biosensors are based on the modification of paper-based platforms placed in commercial screen-printed electrodes [17, 18], or rely on the fabrication of lab-made functionalized paper-based screen-printed electrodes [27].
Concerning the optical approaches used in the paper-based devices, the most applied strategies were based on colorimetric measurement [19, 20, 28] using image processing algorithms as an analytical system. In this context, a colorimetric based approach for the detection of Pb2+ and for U(VI) resorted to the acquisition of images of the paper spots with a digital camera, and images processed using the ImageJ software [20, 24]. On the other hand, Adkins et al. [28] developed a paper-based colorimetric method for the detection of
Other example of mobile-based strategy involves the quantification of different pathogens (
A piezoelectric strategy was also implemented for measurement of immunoagglutinated samples for the detection of
3.2 Biorecognition elements
The biorecognition element has a strong and selective affinity to the target. There are several types of biorecognition elements, such as natural biomolecules (nucleic acids, antibodies, enzymes, and other proteins), synthetic bioelements (molecularly imprinted polymers, aptamers), or whole cells (Figure 2) [1].
Different types of biorecognition elements have been applied for the development of paper-based biosensors for the detection of target analytes in water. An in vitro transcription/translation system reconstituted from purified recombinant components necessary for
Concerning the application of antibodies as biorecognition elements, specific antibodies (polyclonal rabbit anti-EE2) have been applied for the detection of the estrogen ethinylestradiol in river water samples [16, 17]. In addition, suspensions of antibody-conjugated particles were used for the detection of two target pathogens (
Biomolecules aiming the detection of toxic metals can also be referred. A complex comprising magnetic beads, gold nanoparticles (AuNPs), and the functional nucleotide GR5-DNAzyme was applied as a biorecognition element of lead ion [20]. In another work, the recombinant human metallothionein 1a, a metal-binding protein [18], was used for the recognition of As3+ and Hg2+ in water. The tetrameric protein lectin concanavalin A (obtained from
Finally, whole-cell living bacterial biosensors for arsenite detection were based on genetically engineered
4. Applications
In this section, the application of paper-based biosensors for the detection of different types of target analytes in water samples is discussed. In Table 2, the main features of the target analyte, the sample type, the paper substrate, and the fabrication method of the paper-based device, the method of detection, and the biorecognition element are summarized.
Target | Sample type | Paper substrate; fabrication method | Detection method | Biorecognition element | LOD | Reference |
---|---|---|---|---|---|---|
Pharmaceuticals | ||||||
Ethinylestradiol (EE2) | River water | Filter paper grade 1; wax printing | F | Antibody (anti-EE2) | 0.05 ng L−1 | [16] |
EE2 | River water | Filter paper grade 1; wax printing | E | Antibody (anti-EE2) | 0.1 ng L−1 | [17] |
Antibiotics inhibiting protein synthesisa | Surface water | Filter paper discs, 1442-055; cutting by punching | C | Enzyme (β-galactosidase) | 0.5–6.1 μg L−1 | [19] |
Metals | ||||||
Arsenic, mercury | Ultrapure water | Filter paper grade 1; cutting by punching | E | Recombinant human metallothionein 1a | 13 ppb (As3+); 45 ppb (Hg2+) | [18] |
Lead ion | River water; synthetic urine | Chromatography paper; wax printing | C | GR5-DNAzyme | 0.3 nM | [20] |
Uranium (VI) | River water | Cellulose and nitrocellulose membranes; assembling of different layers in a plastic backing card | C | 12F6 antibody against U(VI)-chelator complex | 36 nM | [20, 24] |
Arsenite | Ground-water | 0.5 × 4 cm paper; cutting | C | 8 μg L−1 | [30] | |
Cd2+ | Drinking water, tap water | Hi-Flow Plus nitrocellulose membrane; assembling of different layers in a plastic backing card | C | Cd–EDTA–BSA–AuNP | 0.1 ppb | [23] |
Pathogens | ||||||
Deionized water; serum simulant | Paper Chr. grade 2; wax printing | P | Antibody-conjugated particles | 1 log CFU mL−1 b; 20 pg mL−1 c | [21] | |
E. coli K12 and Zika virus | Deionized water; simulated serum | Paper Chr. grade 2; wax printing | R | Antibody (goat polyclonal) | 2 log CFU mL−1 b; 0.531d | [22] |
Bacterial cultures from sewage sludge | Synthetic wastewater | Cotton-based paper; screen printing | E | Lectin concanavalin A | 1.9 × 103 CFU mL−1 | [27] |
E. coli, | Lagoon water, alfalfa sprout | Multiuse recycled copy paper; wax printing | C | Substrates ONP and PNP | 81 μM (ONP), 119 μM (PNP) | [28] |
Others | ||||||
Water toxicity | Artificial wastewater | Cotton-based paper; screen printing | E | Biofilm formed from anaerobic sludge | 0.1e | [25] |
Shock pollution | Wastewater | Filter paper; ink coating | E | Bacteria consortium | 0.022f | [26] |
Pharmaceuticals are among the targets. Indeed, they are considered emerging environmental contaminants, as they can be harmful to human health and to aquatic life. In this context, the synthetic hormone—ethinylestradiol, one of the main compounds of oral contraceptives, is considered an emerging pollutant due to its potential high estrogenic effect on the biota. Scala-Benuzzi et al. developed two different methods for the detection of ethinylestradiol in river water samples using an antiethinylestradiol specific antibody [16, 17]. In both approaches, the water samples were filtered, and pH was adjusted to 7.0 with phosphate buffer before the analysis. In one work, a fluorescent paper-based biosensor was implemented [16]. This methodology presented a limit of detection (LOD) of 0.05 ng L−1, which is mainly related to the high sensitivity of fluorescence methods. In another work, ethinylestradiol was detected in river water with a paper-based immunosensor based on electrochemical analysis [17], which also reached a low LOD value of 0.1 ng L−1, suitable for environmental analysis.
Antibiotics are another group of pollutants of great concern due to the global threat of antimicrobial resistance and the excessive, and sometimes abusive, use of these compounds. A colorimetric biosensor for screening of several antibiotics (paromomycin, tetracycline, chloramphenicol, and erythromycin) inhibiting bacterial protein synthesis was applied for the detection of antibiotics in surface water [19]. The method was based on the ability of these antimicrobials to inhibit β-galactosidase synthesis. When a water sample without the target antibiotics was placed in the paper-based device, the enzyme β-galactosidase was synthetized and its activity induced a color change on the paper disc surface. However, when antibiotics were present, the inhibition of β-galactosidase synthesis prevented the change of color. Despite the limit of detection was on the microgram per milliliter level (0.5, 2.1, 0.8, and 6.1 μg mL−1 for paromomycin, tetracycline, chloramphenicol, and erythromycin, respectively), this biosensor can be applied as a simple and portable screening methodology.
Heavy metals are naturally present in the environment. However, these elements can be toxic to human and aquatic organisms even at low concentrations. Moreover, their presence can be increased by industrial and agriculture activities. Vijitvarasan et al. implemented a paper-based scanometric biosensor for the detection of lead in water [20]. The biosensor was applied to river water samples. These samples were filtered, diluted 10 times with 10 mM tris-acetate buffer and spiked with different Pb2+ concentrations before analysis. An LOD value of 0.9 nM was determined. Furthermore, a method using a sensitive gold nanoparticle-based lateral flow immunodevice [23] was applied for the quantification of cadmium. Drinking water samples were spiked with 10 and 100 ppb of Cd2+, and other 11 metals commonly found in such type of water, containing also EDTA and ovoalbumin (masking agent). An LOD of 0.1 ppb was achieved.
A semiquantitative approach based on a paper-based bacterial biosensor was applied [30] for the detection of arsenite in groundwater samples. It was observed that arsenite produced a visible blue color from substrate of β-galactosidase (reporter protein) at arsenite concentration above 8 μg L−1. Finally, a paper-based lateral flow device was developed for uranium (VI) determination with an LOD (36 nM) below the action level established by the World Health Organization (126 nM) using an immunological competitive approach [24]. These sensors are a suitable tool for field analysis, in opposition to conventional time-consuming and expensive techniques performed under lab environment.
Sensors based on microbial metabolism were developed for application in wastewaters. Pollution peaks, meaning the abrupt change in concentration of organic and metal pollutant in wastewater treatment plants, can compromise the biological treatment phases by killing or inhibiting microorganisms present in sludge. Hence, untargeted sensors were developed using either biofilms [25] or bacteria consortium [26] to report spiking pollution in wastewater influents.
Waterborne pathogens are a major public health as they can lead to several diseases such as cholera, typhoid fever, and dysentery. Hence, accessible, cheap, and disposable analytical tools for monitoring the presence of these pathogens are mandatory, especially in areas with low resources. In this context, an electrochemical paper-based biosensor [28] was developed for the detection of
5. Conclusions
The paper-based biosensors developed for quantification of the synthetic hormone EE2 presented higher sensitivity when compared to the more complex and expensive LC-MS/MS methods [31, 32]. With respect to the developed biosensors for quantification of different metals (uranium [24], arsenite [30], and cadmium [23]), the LOD was lower than their respective MCLs, thus complying with regulatory requirements. Furthermore,
The most frequently used transducers comprised electrochemical and optical methods, with analytical strategies based on colorimetric reactions, associated with image processing analysis. Besides the recent advances in the development of paper-based analytical tools and biosensor devices, their association to the analysis of contaminants in water is still an open research field with a high potential for the implementation of new portable and low-cost analytical methods for
Acknowledgments
This work received financial support from the European Union (FEDER funds through COMPETE POCI-01-0145-FEDER-031756) and National Funds (FCT/MEC, Fundação para a Ciência e Tecnologia and Ministério da Educação e Ciência) through project PTDC/CTAAMB/31756/2017.
References
- 1.
Hashemi Goradel N, Mirzaei H, Sahebkar A, Poursadeghiyan M, Masoudifar A, Malekshahi ZV, et al. Biosensors for the detection of environmental and urban pollutions. Journal of Cellular Biochemistry. 2018; 119 (1):207-212. DOI: 10.1002/jcb.26030 - 2.
Ebele AJ, Abou-Elwafa Abdallah M, Harrad S. Pharmaceuticals and personal care products (PPCPs) in the freshwater aquatic environment. Emerging Contaminants. 2017; 3 (1):1-16. DOI: 10.1016/j.emcon.2016.12.004 - 3.
Peixoto PS, Toth IV, Segundo MA, Lima JLFC. Fluoroquinolones and sulfonamides: Features of their determination in water. A review. International Journal of Environmental Analytical Chemistry. 2016; 96 (2):185-202. DOI: 10.1080/03067319.2015.1128539 - 4.
Zulkifli SN, Rahim HA, Lau WJ. Detection of contaminants in water supply: A review on state-of-the-art monitoring technologies and their applications. Sensors and Actuators B: Chemical. 2018; 255 :2657-2689. DOI: 10.1016/j.snb.2017.078 - 5.
EPA. Edition of the Drinking Water Standards and Health Advisories. EPA 822-F-18-001. Washington, DC: U.S. EPA Office of Water; 2018 - 6.
World Health Organization. Guidelines for Drinking-Water Quality: Fourth Edition Incorporating First Addendum. 4th ed + 1st add. World Health Organization; 2017 - 7.
EPA. Recreational Water Quality Criteria. U.S. EPA Office of Water 820-F-12-058; 2012 - 8.
Busa LSA, Mohammadi S, Maeki M, Ishida A, Tani H, Tokeshi M. Advances in microfluidic paper-based analytical devices for food and water analysis. Micromachines. 2016; 7 (5):-21. DOI: 10.3390/mi7050086 - 9.
Ejeian F, Etedali P, Mansouri-Tehrani HA, Soozanipour A, Low ZX, Asadnia M, et al. Biosensors for wastewater monitoring: A review. Biosensors & Bioelectronics. 2018; 118 :66-79. DOI: 10.1016/j.bios.2018.07.019 - 10.
Aydindogan E, Celik EG, Timur S. Paper-based analytical methods for smartphone sensing with functional nanoparticles: Bridges from smart surfaces to Global Health. Analytical Chemistry. 2018; 90 :12325-12333. DOI: 10.1021/acs.analchem.8b03120 - 11.
Liana DD, Raguse B, Gooding JJ, Chow E. Recent advances in paper-based sensors. Sensors. 2012; 12 (9):11505-11526. DOI: 10.3390/s120911505 - 12.
Martinez AW, Phillips ST, Butte MJ, Whitesides GM. Patterned paper as a platform for inexpensive, low-volume, portable bioassays. Angewandte Chemie International Edition. 2007; 46 (8):1318-1320. DOI: 10.1002/anie.200603817 - 13.
Almeida MIGS, Jayawardane BM, Kolev SD, McKelvie ID. Developments of microfluidic paper-based analytical devices (muPADs) for water analysis: A review. Talanta. 2018; 177 :176-190. DOI: 10.1016/j.talanta.2017.08.072 - 14.
Zhang D, Liu Q. Biosensors and bioelectronics on smartphone for portable biochemical detection. Biosensors & Bioelectronics. 2016; 75 :273-284. DOI: 10.1016/j.bios.2015.08.037 - 15.
Li X, Tian JF, Shen W. Progress in patterned paper sizing for fabrication of paper-based microfluidic sensors. Cellulose. 2010; 17 (3):649-659. DOI: 10.1007/s10570-010-9401-2 - 16.
Scala-Benuzzi ML, Takara EA, Alderete M, Soler-Illia G, Schneider RJ, Raba J, et al. Ethinylestradiol quantification in drinking water sources using a fluorescent paper based immunosensor. Microchemical Journal. 2018; 141 :287-293. DOI: 10.1016/j.microc.2018.05.038 - 17.
Scala-Benuzzi ML, Raba J, Soler-Illia G, Schneider RJ, Messina GA. Novel electrochemical paper-based immunocapture assay for the quantitative determination of ethinylestradiol in water samples. Analytical Chemistry. 2018; 90 (6):4104-4111. DOI: 10.1021/acs.analchem.8b00028 - 18.
Irvine GW, Tan SN, Stillman MJ. A simple metallothionein-based biosensor for enhanced detection of arsenic and mercury. Biosensors-Basel. 2017; 7 (1):11. DOI: 10.3390/bios7010014 - 19.
Duyen TTM, Matsuura H, Ujiie K, Muraoka M, Harada K, Hirata K. Paper-based colorimetric biosensor for antibiotics inhibiting bacterial protein synthesis. Journal of Bioscience and Bioengineering. 2017; 123 (1):96-100. DOI: 10.1016/j.jbiosc.2016.07.015 - 20.
Vijitvarasan P, Oaew S, Surareungchai W. Paper-based scanometric assay for lead ion detection using DNAzyme. Analytica Chimica Acta. 2015; 896 :152-159. DOI: 10.1016/j.aca.2015.09.011 - 21.
Klug KE, Reynolds KA, Yoon JY. A capillary flow dynamics-based sensing modality for direct environmental pathogen monitoring. Chemistry: A European Journal. 2018; 24 (23):6025-6029. DOI: 10.1002/chem.201800085 - 22.
McCracken KE, Tat T, Paz V, Reynolds KA, Yoon JY. Immunoagglutinated particle rheology sensing on a microfluidic paper-based analytical device for pathogen detection. In: ASABE Annual International Meeting Spokane. United States: American Society of Agricultural and Biological Engineers; 2017 - 23.
Lopez-Marzo AM, Pons J, Blake DA, Merkoci A. High sensitive gold-nanoparticle based lateral flow immunodevice for Cd2+ detection in drinking waters. Biosensors & Bioelectronics. 2013; 47 :190-198. DOI: 10.1016/j.bios.2013.02.031 - 24.
Quesada-Gonzalez D, Jairo GA, Blake RC, Blake DA, Merkoci A. Uranium (VI) detection in groundwater using a gold nanoparticle/paper-based lateral flow device. Scientific Reports. 2018; 8 . DOI: 10.1038/s41598-018-34610-5 - 25.
Chouler J, Cruz-Izquierdo A, Rengaraj S, Scott JL, Di Lorenzo M. A screen-printed paper microbial fuel cell biosensor for detection of toxic compounds in water. Biosensors & Bioelectronics. 2018; 102 :49-56. DOI: 10.1016/j.bios.2017.11.018 - 26.
Xu ZH, Liu YC, Williams I, Li Y, Qian FY, Zhang H, et al. Disposable self-support paper-based multi-anode microbial fuel cell (PMMFC) integrated with power management system (PMS) as the real time “shock” biosensor for wastewater. Biosensors & Bioelectronics. 2016; 85 :232-239. DOI: 10.1016/j.bios.2016.05.018 - 27.
Rengaraj S, Cruz-Izquierdo A, Scott JL, Di Lorenzo M. Impedimetric paper-based biosensor for the detection of bacterial contamination in water. Sensors and Actuators B: Chemical. 2018; 265 : 50-58. DOI: 10.1016/j.snb.2018.03.020 - 28.
Adkins JA, Boehle K, Friend C, Chamberlain B, Bisha B, Henry CS. Colorimetric and electrochemical bacteria detection using printed paper- and transparency-based analytic devices. Analytical Chemistry. 2017; 89 (6):3613-3621. DOI: 10.1021/acs.analchem.6b05009 - 29.
Carrilho E, Martinez AW, Whitesides GM. Understanding wax printing: A simple micropatterning process for paper-based microfluidics. Analytical Chemistry. 2009; 81 (16):7091-7095. DOI: 10.1021/ac901071p - 30.
Stocker J, Balluch D, Gsell M, Harms H, Feliciano J, Daunert S, et al. Development of a set of simple bacterial biosensors for quantitative and rapid measurements of arsenite and arsenate in potable water. Environmental Science & Technology. 2003; 37 (20):4743-4750. DOI: 10.1021/es034258b - 31.
Viglino L, Aboulfadl K, Prevost M, Sauve S. Analysis of natural and synthetic estrogenic endocrine disruptors in environmental waters using online preconcentration coupled with LC-APPI-MS/MS. Talanta. 2008; 76 (5):1088-1096. DOI: 10.1016/j.talanta.2008.05.008 - 32.
Avar P, Zrinyi Z, Maasz G, Takatsy A, Lovas S, G-Toth L, et al. Beta-estradiol and ethinyl-estradiol contamination in the rivers of the Carpathian Basin. Environmental Science and Pollution Research. 2016; 23 (12):11630-11638. DOI: 10.1007/s11356-016-6276-2