Mathematical Model on Magnetic Drug Targeting in Microvessel

By Sachin Shaw

Submitted: October 16th 2017Reviewed: January 10th 2018Published: September 19th 2018

DOI: 10.5772/intechopen.73678

Downloaded: 307

Abstract

Drug targeting is a process by which the distribution of drug in an organism is deployed in such a manner that its major fraction interacts exclusively with the target tissue at the cellular or subcellular level. Magnetic drug targeting is one of the major drug delivery methods due to its noninvasiveness, high targeting efficiency, and minimized toxic side effects on healthy cells and tissues. There are several experimental works on the magnetic drug targeting through microvessel, but very few works are carried out on the mathematical models on magnetic drug delivery. The aim of the present chapter is to discuss all major and minor factors, such as fluidic force, magnetic force, particle-particle interaction, inertia force, Saffman lift force, permeability of the microvessel and carrier particle, and so on, which influenced the drug targeting through microvessel by considering the nature of blood flow as Newtonian, non-Newtonian, single phase, and two phase model. A brief details of fluidic force, magnetic force, particle-particle interaction, Saffman force, buoyancy force, etc. Mathematical models on the fluidic force are discussed for Newtonian, non-Newtonian fluid, single phase, and two-phase fluid model including other forces that influence the magnetic drug targeting in microvessel.

Keywords

  • magnetic drug targeting
  • mathematical model
  • non-Newtonian fluid
  • single phase
  • two-phase flow

1. Introduction

Magnetic micro- and nanoparticles are finding increasing use in different fields of microbiology, biomedicine, and biotechnology where they are used to transport and separate materials, label, and to deliver therapeutic drugs to a target tissue. The use of the magnetic particles as transport agents in different bio-applications has been discussed by Furlani [1]. They have discussed the advantages of using magnetic nanoparticles which are well suited for the different bio-applications due to the following reasons: (1) they are nontoxic and well tolerated by living organisms after being well synthesized and functionalized; (2) they can be synthesized in sizes that range from a few nanometers to higher ranges with a very narrow interval. This nature makes them ideal for probing and manipulating bioparticles and biosystems of different ranges such as protein (5–50 nm), viruses (20–50 nm), genes (2 nm wide and 10–100 nm long), or whole cells (10–100 μm). It is also noted that sub-micron and micron-sized magnetic nanoparticles are used in different bio-applications; (3) magnetic nanoparticles are very familiar with custom-tailored surface treatment to enhance biocompatibility and enable coating with affinity biomolecules for highly specific binding with a target biomaterial; (4) magnetic nanoparticles can easily be magnetized by an applied magnetic field, but once field is removed, it reverts back to an unmagnetized state. This behavior can easily be used to separate or immobilize magnetically labeled biomaterials from a carrier fluid using an external magnetic field. Significantly, the relatively low permeability of an aqueous carrier fluid enables efficient magnet coupling to an immersed magnetically labeled biomaterial. Moreover, the low intrinsic magnetic susceptibility of most biomaterials provides substantial contrast between labeled and unlabeled material, which enables a high degree of selectivity and detection. Magnetic labeling has advantages over conventional fluorescence and chemiluminescence-based biolabels. Notably, small samples of magnetically labeled material can be detected using ultra-sensitive ferromagnetic “spin valve” sensors, which can be integrated into microfluidic-based diagnostic systems.

Magnetic particles have an additional advantage, mainly designed to absorb energy at a resonant frequency from a time-varying magnetic field, which enables their use for therapeutic hyperthermia of tumors. During radio frequency (RF) hyperthermia, magnetic nanoparticles are directed to malignant tissue and then irradiated with an AC magnetic field of sufficient magnitude and duration to heat the tissue to 42°C for 30 min or more, which is sufficient to destroy the tissue (Moroz et al., [2]). In the same manner, it will be used for other cancer therapies (Hergt and Duzt [3]; Gupta and Gupta [4]; Shaw and Murthy [5, 6, 7]). Magnetic nanoparticles are also used for bioimaging, both optically, using surface-bound fluorophores for biophotonic applications (Kircher et al. [8]; Sahoo et al. [9]; Sosnovik et al. [10]; Prasad [11]; Levy et al. [12]; Medarova et al. [13]) and magnetically where they serve as contrast agents for enhanced MRI.

Drug targeting is a process by which the distribution of drug in an organism is deployed in such a manner that its major fraction interacts exclusively with the target tissue at the cellular or subcellular level. Magnetic drug targeting is one of the major drug delivery methods due to its noninvasiveness, high targeting efficiency, and minimized toxic side effects on healthy cells and tissues (Lübbe et al. [14]; Alexiou et al. [15]). This drug targeting is mainly used for the medical treatment of various diseases, especially cancer, and cardiovascular and endovascular diseases, such as stenosis, thrombosis, aneurysm, atherosclerosis (Jurgons et al. [16]), trancheobronchial airways (Pourmehran et al. [17]), and so on. Magnetic drug targeting is a growing interest with recent progress in the development of carrier particles that are designed to target a specific tissue and effect local chemo-, radio- and gene therapy at the tumor site (Figure 1) (Fabrizio and Francois [18]; Berryl and Curtis [19]).

Figure 1.

Schematic illustration of multifunctional and stimuli-responsive porous carrier particle, which is modified with specific antibodies, ligands targeting the cell surface, and anti-adhesive molecules (shown in the red area), and loaded with magnetic particles, fluorescent agents, and drugs for imaging, detection, and therapy (shown in the blue area). It is synthesized from stimuli-responsive polymers or modified with responsive molecules, which can respond to the change of environmental stimuli like pH, light, heat, oxides, and so on. (shown in the yellow area) (Fan et al. [20]).

Magnetic drug targeting is one of the growing interests with recent progress in the development of carrier particles that are designed to target a specific tissue to cure the tumor. In magnetic drug targeting, the therapeutic agent can be either encapsulated into a magnetic micro- or nanosphere or conjugated on its surface. Magnetic particles with bound drug molecules are injected into the vascular system upstream from the malignant tissue (Figure 2). They can be immobilized at the tumor site using a local magnetic field gradient produced by an external field source. Particle accumulation at the tumor is often augmented by magnetic agglomeration, and the efficiency of the accumulation depends on various physiological parameters including particle size, surface characteristics, field strength, blood flow rate, and so on (Figure 3).

Figure 2.

Noninvasive magnetic drug targeting in a microvessel (Furlani [1]).

Figure 3.

Drug-loaded carrier is typically composed of a magnetic core and a biocompatible coating material. The magnetic core was made from different materials such as Fe3O4, Fe2O3, or Fe. The coating materials are Au, PEG, or SiO2. Based on the biokinetics of particles, a drug carrier ranging from 10 to 200 nm in diameter is optimal for in vivo delivery, as the small particles (D < 10 nm) escape by renal clearance and the large ones (D > 200 nm) are sequestered by the reticuloendothelial system of the spleen and liver (Lunnoo and Puangmali [22]).

Upon achieving a sufficient particle concentration at a tumor, drug molecules can be released from their carrier particles by changing physiological conditions such as pH, osmolality, or temperature, or by enzymatic activity (Berry and Curtis [19]; Arrueboa et al. [21]). Since the therapeutic agents are localized to regions of diseased tissue, higher dosages can be applied, which enables more effective treatment. This is in contrast to less selective conventional chemotherapy wherein a toxic drug is distributed systemically throughout the body, potentially harming healthy tissue.

During magnetic drug targeting, beyond fluidic force and magnetic force, there are several factors that play a different role in the phenomena. They are related to blood flow such as particle-particle interaction (mainly for the vessel with small radius), Saffman lift force, and so on. Some of them related to the drug particles e.g., drag force, interparticle effects such as magnetic dipole interactions, particle-blood cell interaction, etc. Here, one by one, we discuss different forces that directly influence the trajectories of the carrier particle and on magnetic drug targeting.

2. Magnetic force on the particle

Magnetic force on the particle that flows with the fluid is well described by Furlani and Furlani [23]. By linear magnetization model, relation of magnetization and intensity of the magnetic field in the saturation can be written as

Msp=χpHin,sat,E1

where χp=μp/μ01is the susceptibility of the particle, μpis the permeability of the particle, and μ0is the permeability of air. The magnetic force is determined by “effective” dipole moment method as described by Jones [24] and Furlani [25]. In this method, the magnetized particle will be replaced by an “equivalent” point dipole with a moment mp,eff, and the force on the dipole (and hence on the particle) is given by

Fm=μfmeff.Ha,E2

where μfis the permeability of the transport fluid, meffis the effective dipole moment of the particle, and Hais the externally applied magnetic field intensity at the center of the particle, where the equivalent dipole is located. Firstly, we solve the magneto-static boundary value problem for the particle (here the considered shape of the particle is spherical, and it may change according to the shape) immersed in a fluid where the magnetization Mpis parallel to the applied field and then determine the equivalent point dipole moment mp,eff. Spherical coordinate system (r.θ,ϕ)is considered for the spherical particle with origin as the center of the spherical particle. Cartesian coordinates (x,y,z) are considered for the microvessel and magnet (see Figure 4).

Figure 4.

Geometry and reference frame for analysis: (a) coordinate systems and reference frames, (b) magnetic flux lines for a cylinder magnet, cross-section of microvessel with reference frame (Furlani [23]).

The potential field inside and outside of the particle can be written as

Φinrθ=Hin=Cinrcosθr<Rp.E3
Φoutrθ=Hout=Harcosθ+Coutcosθr2rRp.E4

where Rpis the radius of the spherical particle. Moreover, we considered zaxis in the direction of applied magnetic field. The magnitude of the field intensity inside the particle in the zaxis is

Hin,z=rΦinrθcosθ+1rrΦinrθsinθ.E5

The corresponding boundary condition with respect to the potential inside and outside the particle surface and normal component of resultant of the magnetic force are written as:

Φinrθ=Φoutrθ,μ0rΦin+Mp=μfrΦout.E6

Solving Eqs. (3) and (4) with boundary condition (6), we get

Cin=3μfμ0+2μfHaμ0μ0+2μfMa,E7

and

Cout=Rp3μ0μfμ0+2μfHa+μ0μ0+2μfMa.E8

From the definition (see Eq. (3)), it is clear that Hin=Cinand if the particle is below the saturation, then Mp=χpHin. By substituting these two relations in Eq. (7), we get:

Hin=3χf+1χpχf+3χf+1Ha,E9

and

Mp=χpHin=3χpχf+1χpχf+3χf+1Ha.E10

The magnitude of the “equivalent” dipole for the particle is related to Cout, and it can be written as

mp,eff=4πCout=Vp3χpχfχpχf+3χf+1Ha,E11

where Vp=4/3πRp3which is the volume of the spherical particle.

Substituting Eq. (11) into Eq. (2), we can define the magnetic force in the form of

Fm=μfVp3χpχfχpχf+3χf+1Ha.Ha.E12

Now when the susceptibility of the fluid is very small (i.e., χf1), then μfμ0and hence Eq. (12) can be written as

Fm=μ0Vp3χpχfχpχf+3χf+1Ha.Ha.E13

In similar fashion,

Hin=3χpχf+3Ha,E14

and

mp,eff=Vp3χpχfχpχf+3Ha.E15

In general, the effective dipole moment can be written as

mp,eff=VpfHaHa,E16

where

fHa=3χpχfχpχf+3,Ha<χpχf+33χpMspMsp/Ha,Ha<χpχf+33χpMspχf<<1E17

and Ha=Ha.

In this analysis, we assume that the magnet is infinitely extended in the y-direction, and therefore the ycomponent of the magnetic field and force is considered as zero.

So, the intensity of the magnetic field and magnetic force has two components along xaxis and zaxis. The resultant of the intensity of the magnetic field is written as

Ηa=Haxxzx̂+HazxzẑE18

and similarly, the resultant of the magnetic force is written as

Fm=Fmxxzx̂+Fmzxzẑ,E19

where

Fmxxz=μ0VpfHaHaxxzHaxxzx+Haz(xz)Haxxzz,E20

and

Fmxxz=μ0VpfHaHaxxzHazxzx+Haz(xz)Hazxzz.E21

2.1. Magnetic field and force of a cylindrical magnet

Equations (20) and (21) represent the magnetic force for a rectangular cylinder whose y-axis extends infinitely and components of the magnetic force act along xand zaxis. The calculation will be different for the case of cylindrical magnet. The cylindrical coordinate system (r,ϕ) with origin as the center of the magnet is shown in Figure 4.

Components of the intensity of the magnetic field in cylindrical coordinates are written as

Hr'r'ϕ=MsRmag22r'2cosϕ,E22

and

Hϕ'r'ϕ=MsRmag22r'2sinϕ.E23

Again, the geometry of the microvessel and flow nature is considered as the Cartesian coordinate system, and so it is necessary to convert the cylindrical coordinate system into the general Cartesian coordinate systems, say (x,z); then, the intensity of the magnetic field in the Cartesian coordinate system is written as:

Hx'x'z'=MsRmag22x'2z2x'2+z22,E24
Hz'x'z'=MsRmag222x'z'x'2+z22,E25

and the corresponding field gradients is written as:

x'Hx'x'z'=MsRmag22x'3z'2x'2x'2+z23,E26
z'Hz'x'z'=MsRmag22z'z'23x'2x'2+z23,E27
z'Hx'x'z'=MsRmag22z'z'23x'2x'2+z23,E28
z'Hz'x'z'=MsRmag2x'x'23z'2x'2+z23.E29

Finally, components of the magnetic field from Eqs. (20) and (21) with the help of expression for intensity of the magnetic fields (Eqs. (26)(29)) in a fixed Cartesian coordinate system (x,z) with respect to the microvessel are written as:

Fmxxz=μ0VpfHaMs2Rmag4x+d2x+d2+z23,E30

and

Fmxxz=μ0VpfHaMs2Rmag4z2x+d2+z23,E31

where drepresents the distance between the axis of magnet and the carrier particle.

This magnetic force is further simplified for noninvasive magnetic drug targeting. In this procedure, the treatment takes place in such a way that there are no breaks in the skin, and there are no contacts with skin break or mucosa, or internal body cavity beyond a natural or artificial body orifice. In this case, the magnet is placed outside the body, and the distance from the magnet to blood vessel is much larger than the diameter of the blood vessel, that is, dx. Furthermore, we used magnetite (Fe3O4) as a magnetic nanoparticle, which is highly biocompatible and for that the susceptibility of the magnetic particle is much larger, that is, χmp1. Based on above two assumptions, the magnetic force components are simplified to:

Fmxxz=3μ0VpMs2Rmag42d2+z23,E32

and

Fmxxz=3μ0VpMs2Rmag4z2d2+z23,E33

3. Fluidic force on the particle

Fluidic force mainly represents the drug force acts on the particle and it depends on the velocity of the fluid. There are several phenomena, and studies have been carried out to understand the blood flow though artery. Blood is a marvelous fluid. Blood consists of a suspension of red blood cells (erythrocytes), white blood cells (leukocytes), and platelets in an aqueous solution (plasma). All contain different density. The plasma is a transparent, slightly yellowish fluid, and its density is about 1.035 gm/ml which can modeled as a Newtonian fluid. The red blood cells are dominant particulate matter in blood with about 40–45% by volume of the whole blood, and it plays a vital role in changing the viscosity of the blood. In general, we use the term “hematocrit” to specify the volume percentage of red cells and entrained plasma. Platelets are much smaller than red or white cells, and so it is not so significant for the nature of blood while it plays a vital role in the formation of blood clots which may severely interfere with the flow.

3.1. Fluidic force for single-phase flow (Newtonian fluid)

We start with a simple mathematical model for drag force. Here we considered blood as a Newtonian fluid. This nature of the blood flow appears mainly for vessel of radius more than 1500 μm. The flow nature is well discussed by Furlani and Furlani [23]. Using Stokes’ approximation, the fluidic force for the Newtonian fluid is written as:

Ff=6πηRcpvcpvf,E34

where vcpis the velocity of the carrier particle, vfis the velocity of the fluid, and η is the viscosity of the fluid. First, we are interested to find the drag force for Newtonian fluid. Assume that the blood vessel is cylindrical and the flow is laminar, fully developed, and symmetric about the axis. So, the velocity profile is function of r (along the axis), and it is written as

vfr=2v¯f1rRv2,E35

where v¯fis the average velocity of blood flow and Rvis the radius of the blood vessel.

With the help of Eq. (34), fluidic forces along the radial and axial radial direction are written as

Ffr=6πηRcpvp,x,E36

and

Ffz=6πηRcpvcp,z2v¯f1rRv2.E37

3.2. Fluidic force for single-phase flow (non-Newtonian fluid model)

The radius of the microvessel plays a vital role on the nature of the blood flow. It is observed that the blood behaves as a non-Newtonian fluid due to low shear stress mainly when the diameter of the vessel is less than 1300 μm. The blood in microvessel is more complex due to the irregular geometry, mechanical behavior of blood, and its cellular constituents (mainly red blood cells). It is well established that the Casson models hold satisfactory for the blood flow through microvessel of diameter 130–1300 μm, while the Herschel-Bulkley model is more suitable for the microvessel of radius 20–100 μm (Mishra et al. [26]; Prier et al. [27]; Bugliarello and Sevilla [28]; Cokelet [29]; Merrill et al. [30]).

The drag force for the Newtonian fluid is different than the non-Newtonian fluid. The drag force for the spherical particle is written as

CD=CDQ=24Xn/Q,E38

where dynamic parameter Q=Re/1+Bi2with Reynolds number Re and Bingham number Bi and Xnis the rheological parameter.

For Casson fluid Xn=1, while Reynolds and Bringham number is written as (Shaw et al. [31])

ReCasson=vcpdcpρν,BiCasson=ρτy/νvcp/dcp,E39

where vcpand dcpare the reference velocity and diameter of the carrier particle ρand νare the density and kinematic viscosity of the fluid.

For Herschel-Bulkley fluid, the rheological parameter Xnis defined in Table 1, and it is well correlated by the following analytical expression (Renaud et al. [32])

Xn=6n1/23n2+n+1n+1.E40
nXn
0.1
0.2
0.3
0.4
0.5
0.6
0.7
0.8
0.9
1.0
1.2
1.4
1.6
1.8
1.354
1.413
1.458
1.442
1.420
1.382
1.320
1.240
1.140
1.002
0.827
0.569
0.390
0.261

Table 1.

Value of rheological parameter X(n) for different values of n.

The Reynolds number and Birmingham number are written as

ReHB=vcp2ndcpnρm,BiHB=τymvcp/dcpn,E41

where m is the Herschel-Bulkley model parameter.

3.3. Shape of the carrier particle

The shape of the carrier particles plays a significant role in magnetic drug targeting. A variety of nonspherical shapes including ellipsoids, discs, cylinders, hemispheres, cones, and red blood cell-like bioconcave discoids have been shown to have an impact on biological processes associated with the delivery of drugs (Geng et al. [33]; Canelas et al. [34]; Doshi and Mitragotri [35]; Enayati et al. [36]). Several experimental and laboratorial scientists have worked on the shape factor of particles in transport through the phagocytosis (Champion and Mitragotri [37]), circulation half-life (Geng et al. [33]), endocytosis (Gratton et al. [38]), targeting efficiency (Sutradhar et al. [39]), subsequent intracellular transport (Yoo et al. [40]), and vasculature (Decuzzi et al. [41]). Spherical and non-spherical carrier particles plays an imperative role on the passive drug targeting and bio-distribution of particles at the vascular level (Champion et al. [37]; Decuzzi et al. [42]; Mitragotri [43]; Fox et al. [44]). An excellent review of different shapes of carrier particles in drug delivery is given by Venkataraman et al. [45] where they discuss different experimental observations in this field and point out that understanding the implications of particle shapes would accelerate the development of next-generation drug delivery vehicles. It is noted that the shape of the magnetic nanoparticle does not change, and it is spherical in shape.

Due to the different shapes, the drag force on the carrier particle is modified as

CD=CDQ=24k'Xn/Q,E42

where kis the shape constant which is defined as

k'=1,Sphere,β21β1/3lnβ+β21,Prolate ellipsoid,2γ31lnγ+0.193,Cylinder,8π3,Circular disk.E43

The fluidic force on the carrier particle in a laminar flow is written as

Ff=12ρAcpvcp2CD,E44

where Acpis a reference cross-sectional area of the carrier particle.

With the help of Eq. (34), fluidic forces for the Casson fluid along the radial and axial radial direction are written as

Ffr=12Acpηk'τyη1/2+vcp,xdcp1/22,E45

and

Ffz=12Acpηk'τyη1/2+vcp,zv¯fdcp1/22.E46

However, fluidic forces for the Herschel-Bulkley fluid along the radial and axial radial direction are written as

Ffr=12AcpXnk'τy+ηvcp,xdcpn,E47

and

Ffz=12AcpXnk'τy+ηvcp,zv¯fdcpn.E48

3.4. Fluidic force for two-phase flow

Due to the microscopic properties of the blood and interaction among its different particles (Blood cells, platelets) in plasma, the nature of blood flow leads a two-phase flow model with a core of rouleaux surrounded by a cell-depicted peripheral layer. Due to the translation, deformation, and rotation, RBCs accumulated near the axis of the vessel and followed a constant velocity while the plasma layer appears near the vessel wall and velocity profile follows a parabolic profile. A mathematical model for a two-phase fluid model has been discussed by Seshadri and Jaffrin [46] in which they have considered the outer layer as cell depleted, having a lower hematocrit than the core region. Later, several researchers are worked on this direction (Gupta et al. [47]; Srivastava [48]; Sankar and Lee [49]).

3.5. Glycocalyx layer and permeability of the microvessel

Permeability of the vessel is another important characteristic, which mainly influences the flow nature of the blood. Due to the wall permeability, the fluid flows laterally and across the vessel fenestrations/pores. Fluid flow through the porous medium is defined by the Darcy law and extended Darcy law or Brinkman Law. Microvessel walls consist mainly of endothelial cell. The vascular endothelium layer helps to regulate the material exchange between circulating blood and the body tissues. The mechanism of the endothelium cells modulates microvessel permeability. It is well known that the luminal surface of the vascular endothelium is lined with a glycocalyx, a layer of membrane-bound macromolecules and adsorbed plasma proteins. This glycocalyx layer is capable of reducing or restricting the plasma flow at the peripheral layer, near to the vessel wall. Moreover, the presence of the glycocalyx layer decreases the effective cross-sectional area of the vessel available for plasma and red cell motion, so that it would possibly cause an increase in flow resistance. The flow resistance highly depends on the thickness of the glycocalyx layer. The flow resistance of the glycocalyx layer is more higher for the thick layer with respect to the thin layer (Pries et al. [27]; Weinbaum et al. [50]; Sugihara-Seki and Fu [51]). It is observed that the permeability of the microvessel significantly changes from organ to organ with the location of the microvessel and is written in ascending order as brain < skin < skeletal muscle < lung < heart <gastrointestinal tract< glomerulus of kidney.

3.6. Porosity of the carrier particle

In recent years, researchers are focused on the development of porous materials as controlled drug delivery matrices due to its unique features such as stable uniform porous structure, high surface area, tunable pore sizes with narrow distribution, and well-defined surface properties (Sher et al. [52]; Shivanand and Sprockel [53]; Ahuja and Pathak [54]) (Figure 5). Due to these wide physical flexibilities, porous carriers have been used in pharmaceuticals for many purposes including development of novel drug delivery systems such as floating drug delivery system, sustained drug delivery system, and improvement of solubility of poorly soluble drugs (Sharma et al. [55]; Streubel et al. [56]). These materials possess larger amounts of nanopores that allow the inclusion of drugs (Wang et al. [57]). Also, these features allow them to adsorb drugs and release them in a more reproducible and predictable manner. The use of mesoporous, microporous, and nanoporous carriers for drug delivery is a part of growing research (Song et al. [58]; Andersson [59]).

Figure 5.

Electron microscopy images of porous Cu2O nanospheres (Zhu [60]).

4. Particle-particle interaction

In a small vessel where diameter of the vessel is less than 500 μm, it is observed that the apparent viscosity of blood is significantly decreased. This reduction of the apparent blood viscosity with decreasing diameter is continued down to the diameter of approximately 10 μm. This phenomenon was first observed by Martini et al. [61] and at the same time by Fahraeus and Lindqvist [62] during their vitro experiment to measure apparent viscosity of blood in a small narrow glass tube. This phenomenon is called as the Fahraeus-Lindqvist effect after their name. The reduction of the apparent viscosity of blood mainly appeared due to the rotation and displacement of the deformable cells (mainly red blood cells) toward the tube axis so that a cell-depleted region (mainly plasma) is formed near the wall. The effect of the cell-depleted region does not significantly influence the apparent viscosity of blood for large vessels (d>500μm) as the width of the cell-depleted layer is much smaller than the diameter of the vessel. Pries et al. [63] compiled literature data on relative blood viscosity in tube flow in vitro and obtained the empirical relationship between the relative apparent viscosity and tube diameter for red cell suspensions with a hematocrit of 45% in glass tubes.

μappμ0.45=220e1.3d+3.22.44e0.06d0.645,E49

where μappis the apparent viscosity, μis the viscosity of the plasma, and d(in μm) is the diameter of the tube. The apparent viscosity of blood for the medium-to-high flow velocities (above 50 tube diameters/s) is written as

μappμ=1+μappμ0.4511HdC110.45C1,E50

where

C=0.8+e0.075d1+11+10d/1012+11+10d/1012.E51

Typical flow patterns of red blood cells in narrow tubes with different diameters are shown in Figure 6. In all cases, at the wall where the highest shear stress occurs (wall shear stress), the local viscosity of blood is the same as the viscosity of plasma (1.2cP), which reduces the wall shear stress and flow resistance.

Figure 6.

Schematic drawings of red cells flowing through narrow glass tubes. The flow is from right to left. The left panel is at low hematocrit, and the right panel is at high hematocrit. Single-file flow is always present in smaller tubes, whereas transition to “zipper” or multi-file flow may occur at higher hematocrit in tubes larger than approximately 7 μm (Gaehtgens [66]).

Red blood cells are gathered near the axis of the vessel and so a cell-free region or low hematocrit region appears near the wall of the vessel. Red blood cells flow faster than the cell-depleted wall layer which mainly contains plasma and due to that the average velocity at the core region (RBCs’ region) is much higher than the outer region (plasma region). This phenomenon leads to a reduction of the tube hematocrit as compared to the discharged hematocrit. A simple schematic diagram of this model is given in Figure 6 where a steady laminar flow of suspension of cells through a tube to or from a reservoir is considered. The problem leads to conservation of mass, which is written as

HT/Hd=US/UC,E52

where HTand Hdrepresent the volume concentration of cells in the tube and in reservoir, respectively. USand UCare the mean velocities of the suspension and cells, respectively. In narrow tubes, US<UCwhich gives HT<Hdand it implies that HT/Hddecreases with decrease in tube diameter. This phenomenon is called Fahraeus effect. A further decrease in tube diameter below approximate 30 μm and less, we find an increase in HT/Hd, which known as inverse Fahraeus effect (Figure 7). The dependence of HT/Hdon tube diameter D (in μm) and discharge hematocrit Hdis compiled by Pries et al. [64] and is written as

HTHd=Hd+1Hd1+1.7e0.415d0.6e0.011d.E53

Figure 7.

(a) Relative apparent viscosity of blood and (b) hematocrit ratio HT/HD, as a function of tube diameter. Solid and dashed curves, empirical fit to in vitro experimental data for blood flow in glass tubes (Eqs. (52), (53), and (55)); Dotted curves, prediction by the stacked-coins model Eq. (55); filled circles, theoretical predictions based on axisymmetric geometries at cell velocity = 1 mm/s (Secomb et al. [68]; Secomb [69]). Eqs. (52) and (55) at HD = 0.45 are represented by solid curves, corresponding to normal states.

Consider a Newtonian fluid flow through the vessel as cylindrical tube of diameter d. Consider the viscosity at the core region and outside the core region (or at plasma region) as μand μ0, respectively. Considered the continuity of velocity and stresses at the interface of the core and outer region while a non-slip condition on the tube of the wall. Using the abovementioned assumption, the velocity profile of the fluid as a function of radial coordinates r is written as

u=Pz4μd22r2,λd2rd/2,Pz4μ0λd22r2+Pz4μd221λ2,0rd/2,E54

where Pzrepresents the pressure gradient along the tube axis, λ is a constant which lies between 0 and 1, and λdis the diameter of the core region with das the diameter of the cylinder (vessel).

Using Eqs. (52) and (53), the Fahraeus-Lindqvist effect and Fahraeus effects (Pries et al. [65]) are evaluated as

μapp=μ11μμ0Pz4,HTHd=121Pz41μμ01Pz21μ2μ0.E55

In the limit of λ approaching 0, we have HT/Hd→ 1/2 and μapp/μ→ 1, and in the other way for the limit of λ approaching 1, we have HT/Hd→ 1 and μapp/μμ0/μ.

4.1. Saffman lift force

Saffman lift force is mainly effective for small particles in the shear field. During drug targeting, we always used carrier particles with nanosizes, and so the particles experience a lift force perpendicular to the direction of the flow, which is known as Saffman lift force. The shear lift originates from the inertia effect in the viscous flow around the particle, and it can be defined as (Zheng and Silber-Li [67])

Fsaff=8k'μγ̇/νRcp2vfvcp,E56

where γ̇is the shear rate of the fluid and kis the shape factor.

5. Buoyant force

For the large artery of diameter more than 1000 μm, the buoyant force plays a vital role with the convective term due to the mass of the carrier particle. The buoyant force acting on the carrier particle during its motion in the microvessel is written as

Fb=Vcpρcpρfgx,E57

where gis the gravitational acceleration and Vcpis the volume of the carrier particle.

6. Geometry of the microvessel

The geometry of the microvessel is not uniform throughout the cardiovascular system. Different geometries of the vessel have been observed in the cardiovascular system, such as bifurcated vessel, with atherosclerosis inside the vessel which is attached with the wall of the vessel, curved vessel, and so on. The flow phenomenon is very complex and interesting when blood flows through curved or bifurcated or stenosed artery. Sometimes secondary flow appears near the apex of the bifurcation vessel or near stenosis. In general, numerical simulations are performed to obtain better insights into the theoretical analysis with computational fluid dynamics (Wang et al. [57]; Pourmehran et al. [17]).

7. Inertia force

Inertia force is playing an important role in blood flow through a vessel with a large diameter. In general we may use carrier particles with large radius, which can easily capture the tumor position. In general multiplication of mass of the carrier particle (which is actually same as the velocity of fluid) and acceleration of carrier particles (which is same as the acceleration of the blood flow in vessel) is not negligible, and it gives a significant influence in the magnetic drug targeting.

8. Equation of motion

Equation of the motion is followed by Newton’s second law of motion. According to this law, the total force on any particle is equal to the multiplication of mass and acceleration of the particle. According to this law, the equation of motion is written as

mcpdvcpdt=SumofAllforces=Fm+Ff+Fsaff+Fb,E58

where mcpis the mass of the carrier particle.

Equation (58) represents the force equation in the presence of inertia force. While in the absence of inertia force, when the diameter of the vessel is very small, then the right part of the Eq. (58) is negligible, and the equation of motion can be written as

0=SumofAllforces=Fm+Ff+Fsaff+Fb.E59

9. Conclusion and future work

Magnetic drug targeting is one of the very useful and biocompatible noninvasive methods. Still there are many scopes left to study and build different mathematical models. There are several factors that directly and indirectly act on the drug targeting and influence the trajectory of the carrier particle. Moreover, here the main focus is on the magnetic drug targeting in the cardiovascular, more particularly in the microvessel. Several experimental works have been done in this direction, which can be implemented as mathematical models. Also, magnetic drug targeting is effective for other human systems such as renal system, gastrointestinal tract, and so on.

© 2018 The Author(s). Licensee IntechOpen. This chapter is distributed under the terms of the Creative Commons Attribution 3.0 License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.

How to cite and reference

Link to this chapter Copy to clipboard

Cite this chapter Copy to clipboard

Sachin Shaw (September 19th 2018). Mathematical Model on Magnetic Drug Targeting in Microvessel, Magnetism and Magnetic Materials, Neeraj Panwar, IntechOpen, DOI: 10.5772/intechopen.73678. Available from:

chapter statistics

307total chapter downloads

More statistics for editors and authors

Login to your personal dashboard for more detailed statistics on your publications.

Access personal reporting

Related Content

This Book

Next chapter

Introductory Chapter

By Neeraj Panwar

Related Book

First chapter

Morphotropic Phase Boundary in Ferroelectric Materials

By Abdel-Baset M. A. Ibrahim, Rajan Murgan, Mohd Kamil Abd Rahman and Junaidah Osman

We are IntechOpen, the world's leading publisher of Open Access books. Built by scientists, for scientists. Our readership spans scientists, professors, researchers, librarians, and students, as well as business professionals. We share our knowledge and peer-reveiwed research papers with libraries, scientific and engineering societies, and also work with corporate R&D departments and government entities.

More About Us