This chapter describes a methodology for the development and calibration of computational fluid dynamics (CFD) models of three-dimensional enclosures for buildings with combined forced and natural convection from experimental result. The models were validated with physical test measurements of room air temperature. The developed CFD models included a model of an internal wall-mounted air conditioning (HVAC) split unit. The methodology proposed here aims at selecting the correct grid size and the appropriate boundary conditions from experimental data. The experimental campaign took place in an empty office room within an educational building. A set of experiments was performed with varying boundary conditions of two main variables, the fan speed of the HVAC unit and the surface wall temperature of the opposite wall to the HVAC unit. The developed CFD models used the standard k-ε turbulence model and the SIMPLE algorithm. The variable of interest was the room air temperature and its distribution within the internal environment. The application of the methodology has shown satisfactory results, finding a maximum error of 9% between the CFD model and the experimental result. This methodology can be used by other researchers to calibrate CFD models in existing rooms and then carry out detailed studies of temperature distribution, comfort and energy demand analysis.
Part of the book: Computational Fluid Dynamics Simulations
This work presents a new parametric correlation for 2D enclosures with forced convection obtained from CFD simulation. The convective heat transfer coefficient of walls for enclosures depends on the geometry of the enclosure and the inlet and outlet openings, the velocity and the air to wall temperature difference. However, current correlations not dependent on the above parameters, especially the position of the inlet and outlet, or the temperature difference between the walls. In this work a new correlation of the average Nusselt number for each wall of the enclosure has been developed as a function of geometrical, hydrodynamic and thermal variables. These correlations have been obtained running a set of CFD simulations of a 3 m high sample enclosure with an inlet and outlet located at opposite walls. The varying parameters were: a) the aspect-ratio of the enclosure (L/H = 0.5 to 2), b) the size of the inlet and outlet (0.05 m to 2 m), c) the inlet and outlet relative height (0 m to 3 m high), and d) the Reynolds number (Rein = 103 to 105). Furthermore, a parametric analysis has been performed changing the temperature boundary conditions at the internal wall and founds a novel correlation function that relates different temperatures at each wall. A specifically developed numerical model based on the SIMPLER algorithm is used for the solution of the Navier–Stokes equations. The realisable turbulence k-ε model, and an enhanced wall-function treatment have been used. The heat transfer rate results obtained are expressed through dimensionless correlation-equations. All developed correlations have been compared with CFD simulations test cases obtaining a R2 = 0.98. This new correlation function could be used in building energy models to enhance accuracy of HVAC demands calculation and estimate the thermal load.
Part of the book: Applications of Computational Fluid Dynamics Simulation and Modeling