Experimentally calculated values of local natural convective heat transfer coefficient for three heating conditions of wire.
Abstract
Digital holographic interferometry (DHI) is used worldwide for many scientific and industrial applications. In DHI, two digital holograms; one in the reference/ambient state of the object and another in changed state of object are recorded by electronic imaging sensors (such as CCD/CMOS) as reference holograms and object holograms, respectively. Phase of object wavefronts in different states of the object is numerically reconstructed from digital holograms. The interference phase is reconstructed by subtracting the phase of reference hologram from the phase of object hologram, without performing any phase-shifting interferometry. Thus, no extra effort is needed in DHI for calculating the interference phase. Apart from direct reconstruction of interference phase from two digital holograms, the recent development, availability of recording devices at video rate, and high-performance computers make the measurements faster, reliable, robust, and even real-time. In this chapter, DHI is presented for the investigation of temperature distribution and heat transfer parameters such as natural convective heat transfer coefficient and local heat flux around the surface of industrial heated objects such as cylindrical wires and heat sinks.
Keywords
- digital holography
- interferometry
- temperature
- heat transfer parameters
- convective heat transfer coefficient
- heat flux
1. Introduction
The study of heat flow/heat transfer from industrial heated objects such as wires, cylinders, conductors, and heats sinks is involved in many scientific and industrial applications. The knowledge of surface temperature and temperature profile normal to the surface of heated objects is sought for the measurements of heat transfer parameters such as convective heat transfer coefficients and heat flux [1, 2, 3]. The temperature measurements by intrusive methods such as thermocouple, thermistor, hot wire anemometer, and resistance temperature detector (RTD) are not reliable because these contact type methods disturb the heat flow and also lack in providing full field temperature information [3]. In the past, many optical interferometric methods have been widely used for the measurements of temperature, temperature profile, and heat transfer studies. These methods being non-invasive and non-contact type in nature provide reliable measurement of temperature. Other advantages of optical methods are (1) these methods provide full field temperature measurements in contrast to contact-type methods which provide point-by-point measurements and (2) measurements are inertia free so rapidly time-varying phenomena can also be investigated [3, 4]. Careful use of optical methods leads to more accurate and precise temperature measurements.
In the past, most of the temperature and heat transfer studies such as natural convection, forced convections, heat flux in liquids, and gases from heated objects such as cylinders, vertical plates, horizontal plates, finned plates, compact channels, microprocessor chips, grooved channels, downward facing heater surfaces, rib-roughened vertical surfaces, and horizontal cylinders were performed using classical interferometry (Mach–Zehnder Interferometry [MZI] and Michelson Interferometry [MI]), and holographic interferometry (HI) [5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25, 26, 27, 28, 29, 30, 31, 32, 33, 34]. Goldstein used MZI to study the aerodynamics and heat transfer [20] and Haridas et al. used both MI and MZI to measure the forced convection in compact channels [21]. In these studies it was concluded that MI provides a larger number of fringes (data points) in the temperature fields in comparison to MZI, thus MI is a better method of temperature field measurement in compact channels [21]. MI is more sensitive to temperature change than MZI but MI is not good for studying dynamic/rapidly varying phenomena as the light has to travel the test section/object field two times.
In the temperature and heat transfer studies using classical interferometry and HI mentioned in the above paragraph, the full field quantitative temperature field was not measured but the qualitative information on temperature was visualized. The temperature was calculated at each fringe position (i.e., isothermal line) using fringe count and fringe shift methods. The temperature profile was plotted by fitting the temperature data calculated at the location of each fringe. HI has several advantages in comparison to classical interferometry. HI does not require high-quality optical components in comparison to classical interferometry, because in HI, only the relative phase change of object wavefronts is evaluated. This leads to reduced costs of holographic interferometric equipment. HI provides the major advantage of greater experimental and technical simplicity. Thus, the time required for adjustment of equipment and taking measurement is also reduced considerably [26].
Furthermore, several optical interferometric methods such as classical interferometry [5, 6, 35, 36], holographic interferometry [22, 23, 24, 37], moiré deflectometry [38], speckle shearing interferometry [39], shearing interferometry [40, 41], Talbot interferometry (TI) [42, 43], Lau phase interferometry (LPI) [44], digital speckle pattern interferometry (DSPI) [45], holo-shear lens based lateral shear interferometry [46, 47, 48], and DHI [49, 50, 51, 52, 53, 54, 55, 56, 57, 58] have been investigated to measure the temperature field inside the axi-symmetric gaseous flames and transparent hot objects. TI, Moiré deflectometry, lateral shear interferometry, and holo-shear lens-based interferometry are common path interferometric methods and hence these methods are relatively less sensitive to vibrations or external perturbations as compared to speckle shearing interferometry, HI, and DHI. In shearing interferometry and speckle shearing interferometry, prior information regarding temperature profile direction is required. Prior information regarding temperature profile direction is also needed, if TI and LPI are performed with linear grating. However, TI and LPI using circular grating do not require any prior information regarding temperature field direction [39]. Also, in TI and LPI with linear gratings, the alignment between the gratings is difficult to achieve. LPI uses white light source, so the advantage of using LPI over TI is that it reduces coherent speckle noise in the interferogram, and thus provides high signal-to-noise ratio [39, 59]. TI, LPI, and holo-shear lens-based interferometry require high-quality optical components (such as gratings, lenses, and holo-shear lens) as compared to HI. The interference fringes in speckle shearing interferometry, and DSPI are not of good contrast because these fringes are formed due to speckles. Speckle filtering techniques are used to minimize the speckle noise to get usable information [60, 61].
In digital holography (DH), holograms are recorded in digitized form by using CCD or CMOS sensors and complex amplitude of object wave-front from recorded digital hologram is reconstructed by numerical methods using computers [62, 63, 64]. Thus precise quantitative reconstruction/evaluation of amplitude and phase of an object wave-front from single digital hologram is possible in DH using numerical reconstruction methods. In double exposure DHI, two digital holograms, one in the ambient/reference state of object and other in changed state of objects are recorded. The interference phase is directly calculated from two digital holograms by subtracting the numerically reconstructed phase of reference hologram from the phase of object hologram without performing any phase-shifting interferometry. Thus no extra efforts are required in DHI for the reconstruction of interference phase. Also in DH, the data acquisition rate is also high because by using CCD/CMOS sensor, signals are available at video frequencies. The data acquisition rate in DH is only limited by the frame rate of recording CCD/CMOS sensor. The reconstruction rate is also high (∼1 Hz) and can be controlled by using fast computers and efficient reconstruction algorithms [65]. Hence, the processes of measurement become faster, reliable, and even almost real-time. The sensitivity of photographic plate is ∼105 photons/μm2, whereas the sensitivity of CCD can be ∼1 photon/μm2 [66]. This leads to a large reduction in exposure time as well as simpler requirements on experimental set-up stability against external vibration and perturbations/disturbances. These parameters make the system simple, reliable, robust, more precise, accurate, and more suitable for industrial environment. Whereas, in conventional HI the time-consuming and tedious development process of recording materials makes the use of HI difficult in industrial environment.
In the past, DHI has been extensively used for many applications such as measurement of temperature [49, 50, 51, 52, 53, 54, 55, 56, 57, 58, 67, 68, 69], heat transfer from surface of heated objects [52, 54], diffusion coefficient [70, 71], flow field analysis [72], observation of decomposition of crude oil under dispersant fluid [73], refractive index of liquids [74], heat conduction in glass [75], solution concentration variation in protein crystallization process [76], visualization of thermal gradients in bulb [77], and human skin temperature [78].
In this chapter, DHI in lenless Fourier transform (LLFT) configuration is presented for the investigation of temperature distribution and heat transfer parameters such as natural convective heat transfer coefficient and local heat flux around the surface of industrial heated objects such as cylindrical wires and heat sinks.
2. Theory/methodology
In DH, numerical methods are applied for hologram reconstruction in which diffraction of digital reference wave at the micro interference fringes of digital hologram is simulated using scalar diffraction theory. Several numerical reconstruction methods of hologram such as Fresnel reconstruction [62, 63, 64], convolution [79], and angular reconstruction method [80] have been developed. But, these reconstruction methods suffer from the following shortcomings (1) lateral resolution of the numerically reconstructed images is limited by the inherent coherent speckle noise. For getting high lateral resolution in reconstructed image, the speckle size should be minimized. (2) Due to low spatial resolution (∼125 lines pair per mm for CCD with pixel size 4 μm) of CCD/CMOS sensor, the object needs to be placed at a minimum distance from the sensor to ensure that the angle between the object beam and reference beam does not exceed a certain value at all points of the surface of sensor so that sampling theorem is not violated which requires that fringe spacing of interference pattern in hologram is larger than double the pixel size [64]. (3) Most of holographic set-ups use plane reference waves for hologram reconstruction, and hence the angle between object and the reference beam varies over entire sensor chip and so does the spatial frequency. Thus, the full spatial bandwidth of sensor is not utilized in these set-ups. As the lateral resolution in the reconstruction relies on the complete evaluation of information captured by sensor, so full spatial bandwidth of the sensor should be utilized. Also, in Fresnel and convolution methods, several Fourier transforms and complex multiplications have to be performed. Therefore, to enhance the speed of digital image processing, computation of image reconstruction algorithm should be simpler and fast. All these problems as mentioned above are tackled by lensless Fourier transform digital holography (LLFTDH). Improved lateral resolution and use of the full spatial bandwidth of the CCD sensor can be achieved through LLFTDH. In LLFTDH, set-up, a spherical reference wave is used instead of plane reference wave and the point source of spherical wave is kept in the plane of object. This ensures that the angle between the interfering reference and object beams remains approximately same over the entire sensor chip. Thus, one can ensure that the sampling theorem is not violated over the full area of recording sensor and complete spatial-frequency spectrum of sensor is used at all point of sensor surface area. The entire spatial bandwidth of sensor can be utilized for complete evaluation of all the information one get from the sensor, if the ratio of object size and the distance between the object and the CCD target is optimized [3, 64]. Fresnel reconstruction method is used to derive the reconstruction algorithm of LLFTDH. The digitized form of complex amplitude of object wavefront is expressed as [63].
In Eq. (1), M × N is the total number of pixels on the CCD/CMOS sensor,
In LLFT configuration of DH, the object and point source of spherical wave are kept in same plane. Thus in this configuration, the spherical phase factor associated with the Fresnel diffraction of the transmitted wave through hologram is eliminated by using of a spherical reference wave
By substituting
In Eq. (4), inverse fast Fourier transform (IFFT) of only single term, that is, recorded digital hologram is evaluated apart from some multiplicative constant. Also an autofocus image is obtained without tuning the distance “d”. Thus, this method is simpler and faster as compared to other reconstruction methods such as Fresnel reconstruction and convolution method, in which combination of several Fourier transform and complex multiplications need to be evaluated. The simpler and faster reconstruction algorithm of LLFTDH enhances the possibility of real-time applications [3]. The spatial phase distribution from reconstructed object wavefront is evaluated as [3].
In the above equation, the operators “Re” and “Im” provide the real and imaginary part of complex functions, respectively. In double exposure DHI, two digital holograms, one in Ref. or ambient state of object, and other in changed state of object are recorded. Phases of two different states of the object wavefronts are calculated using Eq. (5). Let
From this equation, one can directly evaluate the interference phase from the digital holograms. This phase is wrapped between 0 and 2π. A continuous phase difference is obtained by applying appropriate phase unwrapping algorithm [84]. The physical parameters of interest like deformation, refractive index, temperature, etc. are calculated from the unwrapped phase difference.
3. Applications of LLFTDHI in heat transfer measurements
3.1 Measurement of heat transfer parameters along the surface of heated wire
Measurement of natural convective heat transfer from heated wires/cylinders is used in several scientific and industrial applications such as quality control of electrical wires, to find ideal insulation properties of current carrying conductors, vertical tubes of HVAC (Heating, Ventilation and Air Conditioning), in resistive heating of electronic components, space shuttle launch pads, waste nuclear rods stored in repositories, refrigerating coils, and hot radiators [3, 57, 85]. Surface temperature and temperature gradient normal to the surface of the heated object is needed for the calculation of heat transfer parameters such as local convective heat transfer coefficient “
In this section, an application of LLFTDHI is presented for the measurement of the natural local (
Phase difference maps of heated air and ambient air around the wire were calculated from the two digital holograms by using Eq. (6), and unwrapped phase difference map was calculated using the Goldstein phase unwrapping method [84]. The phase change
Here
Experiment was conducted in a closed room with stable air, refractive index of heated air around wire can be considered cylindrically symmetrical. For the axisymmetric objects, the evaluated phase difference map can be transformed into a radial distribution of refractive index difference distribution by using inverse Abel transforms as [52].
where
where
where
Initially, an experiment was conducted on three different heating conditions of tungsten wire of diameter 0.4 mm, when applied power across the wire were (I) P1 = 70 Watt, (II) P2 = 46.8 Watt, and (III) P3 = 37 Watt. Different reconstruction steps involved in the temperature profile calculation from the wrapped phase difference map in case when P = 46.8 W, are shown in Figure 3. From Figure 3(d), experimentally calculated surface temperature of wire is found to be 477 K. The surface temperature of wire was also verified with the temperature measured by thermocouple. The thermocouple readings were also in the range 475–479 K (Avg. Temperature 477 K ± 2 K). Temperature profile along the lines AB, CD, EF and GH shown in Figure 3(d) are used to calculate the natural local “
Experimental results corresponding to power P = 70 W and P = 37 W are shown in Figure 4. Experimentally calculated values of “
Height | Applied input power = 70 W, | Applied input power = 46.8 W, | Applied input power = 37 W, |
---|---|---|---|
Along AB | 13.94 | 11.55 | 10.87 |
Along CD | 13.30 | 10.50 | 9.56 |
Along EF | 12.20 | 8.93 | 8.41 |
Along GH | 10.84 | 8.60 | 6.92 |
A comparison of temperature measured by DHI and thermocouple is shown in Figure 5, and a good agreement is observed between the two measurements. Deviations in the temperature measured by DHI and thermocouple are found to be within 0.82–5.2%. The value of “
Further, an experiment was conducted on wires of different diameters (d1 = 0.4 mm, d2 = 0.6 mm, d3 = 0.78 mm) of equal length with a constant power (70 W) applied across the wire. Results are shown in Figure 6. A comparison of experimentally calculated values of local “
Height | Applied input power = 70 W, | Applied input power = 70 W, | Applied input power = 70 W, | |||
---|---|---|---|---|---|---|
Along AB | 13.94 | 3136.5 | 12.38 | 2463.62 | 10.28 | 1778.44 |
Along CD | 13.3 | 2992.5 | 10.78 | 2145 | 8.80 | 1522 |
Along EF | 12.2 | 2745 | 10.12 | 2013 | 8.37 | 1448 |
Along GH | 10.84 | 2439 | 9.37 | 1864 | 7.72 | 1335.56 |
3.2 Heat Flow performances of heat sinks
Electronics circuits, components/devices are highly demanded in every aspect of modern world ranging from toys, appliances to high performance computers. In recent, with increasing demand in processing, manufacturer of electronic circuits/equipment are forced to increase the performance and functionality of electronics components/ICs chips in addition to reducing their sizes. In high performance electronic components /ICs/computers, rate of heat generation is comparatively high. This elevated heat generation from high performance electronic components/devices produces high temperature level in the electronics components/devices, which may lead to their failure due to overheating. Operating temperature of high performance components/devices/computers plays a vital role in maintaining trouble free functioning. So, there is requirement to keep these electronic devices in reasonable temperature range suitable for their functioning by enhancing the transfer of generated heat. The heat sink as a source of heat transfer plays an important role in effective thermal management strategies, which makes the optimization of heat sink design a useful area of investigation. Heat sink are used in effective thermal management for increased reliability and proper functioning of such devices, while micro-channel heat sinks are used in miniaturized heat transport systems like compact heat exchangers, fuel cell powered mechanisms, components of advanced propulsion systems, micro-electromechanical systems (MEMS) applications, and cooling system for fusion reactor, rocket nozzles, avionics, hybrid vehicle power electronics and systems, etc. [3, 54, 56, 85]. The temperature distribution surrounding the heat sink must be measured for investigating the heat flow performance of heat sinks.
This section presents the investigations about heat flow performance from plate fin heat sink using LLFTDHI. Visual inspection of reconstructed phase difference maps of heated air and ambient air around the heat sink provide qualitative information about the variation of temperature and heat dissipation process. Quantitative information of temperature distribution is obtained from the relationship between the digitally reconstructed phase difference map of ambient air and heated air. The effect of fin spacing on the heat flow performance of heat sink is experimentally studied in case of natural heat convection. From experimental data, heat transfer parameters such as local heat flux and convective heat transfer coefficients are also calculated. Same LLFTDHI set-up is used in this application. Figure 7 shows a photograph of DHI set-up used to study the heat flow performance of plate fin heat sink. In experiment, aluminum heat sink is attached with a load resistor in its bottom to heat the heat sink. A known value of voltage and current (5 V and 2.4 A) is applied across the load resistor to heat the heat sink.
During the heating process, several digital holograms are recorded at different time interval. Reconstructed wrapped phase difference maps of hot and ambient air surrounding the heat sink at different times are shown in Figure 8(a)–8(h). Wrapped phase difference maps at time 75 and 90 min. are same. It indicates that that after 75 minute temperature surrounding the heat sink has reached in steady state. It is assumed that the refractive index of air along the direction of propagation of light ray is uniform, then the relationship between the unwrapped phase difference data
where “
In Eq. (12),
Further an experiment was conducted to study the effect of channel width/fin spacing (S) on heat flow performance of the plate fin heat sink. For this purpose, heat sinks with different fin spacing (Number of channels = 6, S1 = 3.25 mm; Number of channels = 5, S2 = 5 mm; Number of channels = 3, S3 = 9 mm) were chosen and all other dimensional parameters of heat sink were kept same. An equal power of P = 16.8 W was applied across the load resistor for all the three heat sinks. In steady state of hot air, experimentally reconstructed phase difference maps of hot air and ambient air for the heat sinks of three different fin spacing are shown in Figure 9(a1)–9(a3). The reconstructed 2D temperature distribution around the heat sink of three channel widths corresponding to Figure 9(a1)–9(a3) are shown in Figure 9(b1)–9(b3). The color variations shown in Figure 9(b1)–9(b3) indicate that the temperature distribution/variation between the adjacent fins. Temperature is observed to be almost constant (i.e., almost negligible temperature gradient) in the case of heat sink of smaller fin spacing (S1 = 3.25 mm), and temperature gradient is the highest in case of the heat sink of largest channel width (S3 = 9 mm). It indicates that heat is accumulated between the adjacent fins of a heat sink with smaller fin spacing and it is more difficult to diffuse the heat than that of heat sinks with larger fin spacing in the case of natural convection.
Temperature profiles along the line AB for the heat sinks of different fin spacing are shown in Figure 9(c). The temperature gradient along AB is observed to be highest for heat sink of wider fin spacing/channel width S3 = 9 mm than that of the heat sinks of lower channel widths (i.e., S1 = 3.25 mm, and S2 = 5 mm). This is the reason why natural local convective “
Table 3 shows a comparison of experimentally calculated values of local convective “
Fin spacing or channel width | Dimensions of heat sink Length Room temperature = 32.5°C, applied power across load resistor = 16.8 W | |||
---|---|---|---|---|
Calculated base temperature Tb (K) | Thermocouple value of Tb (K) | Local convective heat flux (w/m2) | Experimentally calculated | |
402 | 404 | 182.9 | 1.89 | |
397.2 | 400 | 243.6 | 2.64 | |
396.3 | 399 | 305 | 3.34 |
4. Conclusions
In conclusion, this chapter demonstrates LLFTDHI technique for the investigation of temperature distribution, and measurement of heat transfer parameters around the heated industrial objects such as wires/conductors and heat sinks. The LLFT configuration of DHI offers following advantages (1) due to a simpler hologram reconstruction algorithm, it provides faster reconstruction than other counterpart methods such as Fresnel and Convolution approach, (2) it can be implement almost in real time, and (3) LLFTDH provides improved lateral resolution in the reconstructed image because entire spatial bandwidth can be utilized for complete evaluation of information from sensor by optimizing the ratio of object size and distance between object and sensor. The LLFTDHI system is investigated for the following scientific and industrial applications (1) Measurement of temperature profile, natural local convective heat transfer coefficient and heat flux along the surface of electrically heated wire. These investigations are helpful to study the heat transfer characteristics of wires/conductors, and finding ideal insulation properties of wires/conductors. (2) The heat dissipation performances of heat sinks. Heat dissipation capabilities of heat sinks are determined by qualitative and quantitative estimations of temperature distribution and heat transfer parameters. These investigations can be helpful in making the proper choice of the heat sink in the electronic circuit, and are also required in making electronic circuits of high reliability for critical industrial as well as for space application. Based on investigated applications, it can be concluded that LLFTDHI provides a feasible and effective method for temperature measurements and heat transfer studies.
References
- 1.
Hauf W, Grigull U. Optical methods in heat transfer. In: Hartnett JP, Irvine TF. Jr. (eds.). Advances in Heat Transfer. Vol. 6. New York: Elsevier; 1970 Jan 1. pp. 133-366 - 2.
Naylor D. Recent developments in the measurement of convective heat transfer rates by laser interferometry. International Journal of Heat and Fluid Flow. Jun 1 2003; 24 (3):345-355 - 3.
Kumar V. Digital holographic interferometry for the measurement of temperature profile, heat dissipation and contouring [Doctoral dissertation], IIT Delhi; 2016 - 4.
Norris JK. Interferometric measurement of free convective heat transfer coefficients in the transitional and turbulent regimes [Doctoral dissertation], Georgia Institute of Technology. 1973 - 5.
Wilkie D, Fisher SA. Measurement of temperature by Mach-Zehnder interferometry. Proceedings of the Institution of Mechanical Engineers. Jun 1963; 178 (1):461-470 - 6.
Goldstein RJ. Optical measurement of temperature. In: Eckert ERG, Goldstein RJ, editors. Measurement Techniques in Heat Transfer, AGARDograph, no. 130. Slough, London: Technivision Services [distributed by Technical Press]; 1970 Jan 1. pp. 177-228 - 7.
Kennard RB. Temperature distribution and heat flux in air by interferometry. Temperature: Its Measurement and Control in Science and Industry. 1941; 1 :685-706 - 8.
Eckert ER, Soehngen EE. Studies on heat transfer in laminar free convection with the Zehnder-Mach interferometer. Air Materiel Command Wright-Patterson AFB OH; 1948 Dec 27. - 9.
Goldstein RJ, Eckert ER. The steady and transient free convection boundary layer on a uniformly heated vertical plate. International Journal of Heat and Mass Transfer. Aug 1 1960; 1 (2–3):208-218 - 10.
Ostroumov GA. Unsteady heat convection near a horizontal cylinder. Soviet Physics-Technical Physics. Jan 1 1956; 1 (12):2627-2641 - 11.
Vest CM, Lawson LM. Onset of convection near a suddenly heated horizontal wire. International Journal of Heat and Mass Transfer. 1972; 15 :1281-1283 - 12.
Duarte DN. Direct temperature gradient measurement using interferometry. Experimental Heat Transfer. Oct 1 1999; 12 (4):279-294 - 13.
Goharkhah M, Ashjaee M, Madanipour K. Investigation of the accuracy of different methods of interferogram analysis for calculation of local free convection heat transfer coefficient on axisymmetric objects. Experimental Thermal and Fluid Science. 2009 Nov 1; 33 (8):1188-1196 - 14.
Fatehi S, Madanipour K, Parvin P. Measurement of convective heat transfer coefficient around a vertical hot wire in different heights using Michelson interferometer based on Abel transform. Applied Physics Express. 2011; 1 :124-132 - 15.
Kwak CE, Song TH. Natural convection around horizontal downward-facing plate with rectangular grooves: experiments and numerical simulations. International Journal of Heat and Mass Transfer. Mar 1 2000; 43 (5):825-838 - 16.
Wright JL, Jin H, Hollands KG, Naylor D. Flow visualization of natural convection in a tall, air-filled vertical cavity. International Journal of Heat and Mass Transfer. Mar 1 2006; 49 (5–6):889-904 - 17.
Sajith V, Sobhan CB. Digital interferometric measurement of forced convection heat transfer in a miniature rectangular channel. Experimental Heat Transfer. Oct 2 2008; 21 (4):314-333 - 18.
Sajith V, Sobhan CB. Characterization of heat dissipation from a microprocessor chip using digital interferometry. IEEE Transactions on Components, Packaging and Manufacturing Technology. Jun 19 2012; 2 (8):1298-1306 - 19.
Ahadi A, Saghir MZ. An extensive heat transfer analysis using Mach Zehnder interferometry during thermodiffusion experiment on board the International Space Station. Applied Thermal Engineering. Jan 25 2014; 62 (2):351-364 - 20.
Goldstein RJ. Interferometer for aerodynamic and heat transfer measurements. Review of Scientific Instruments. Oct 1965; 36 (10):1408-1410 - 21.
Haridas D, Reddy GR, Sobhan CB. Digital interferometric measurement of forced convection fields in compact channels. International Journal of Optomechatronics. Jan 2 2015; 9 (1):9-34 - 22.
Vest CM. Holographic Interferometry. New York: Wiley; 1979 - 23.
Farrell PV, Springer GS, Vest CM. Heterodyne holographic interferometry: concentration and temperature measurements in gas mixtures. Applied Optics. May 1 1982; 21 (9):1624-1627 - 24.
Reuss DL. Temperature measurements in a radially symmetric flame using holographic interferometry. Combustion and Flame. Jan 1 1983; 49 (1–3):207-219 - 25.
Sweeney DW, Vest CM. Measurement of three-dimensional temperature fields above heated surfaces by holographic interferometry. International Journal of Heat and Mass Transfer. Dec 1 1974; 17 (12):1443-1454 - 26.
Mayinger F, editor. Optical Measurements: Techniques and Applications. Berlin Heidelberg GmbH, Germany: Springer; 1994 - 27.
Herman C, Kang E. Comparative evaluation of three heat transfer enhancement strategies in a grooved channel. Heat and Mass Transfer. Sep 2001; 37 (6):563-575 - 28.
Ambrosini D, Paoletti D, Tanda G. Measurement of free convection heat transfer coefficient along a rib-roughened vertical surface. In 16th International Symposium on Transport Phenomena. Prague, Czech Republic: ISTP; 2005 - 29.
Ambrosini D, Tanda G. Comparative measurements of natural convection heat transfer in channels by holographic interferometry and schlieren. European Journal of Physics. Dec 22 2005; 27 (1):159 - 30.
Herraez JV, Belda R. A study of free convection in air around horizontal cylinders of different diameters based on holographic interferometry. Temperature field equations and heat transfer coefficients. International Journal of Thermal Sciences. Mar 1 2002; 41 (3):261-267 - 31.
Tauscher R, Mayinger F. Visualization of flow temperature fields by holographic interferometry – optimization of compact heat exchangers. Honolulu, USA: Proceedings of PSFVIP-2; 1999 May 16 - 32.
Herman C, Kang E. Experimental visualization of temperature fields and study of heat transfer enhancement in oscillatory flow in a grooved channel. Heat and Mass Transfer. Jan 2001; 37 (1):87-99 - 33.
Manickam S, Dhir V. Holographic interferometric study of heat transfer associated with a single vapor bubble sliding along a downward-facing heater surface. In: Heat Transfer Summer Conference 1 Jan 2003 (Vol. 36940). Las Vegas, Nevada, USA: HTSC; pp. 317–327 - 34.
Spagnolo GS, Ambrosini D. Sandwich holography for determining the convective heat transfer coefficient. Journal of Optics A: Pure and Applied Optics. 2000; 2 (1):39 - 35.
Karaminejad S, Askari MH, Ashjaee M. Temperature field investigation of hydrogen/air and syngas/air axisymmetric laminar flames using Mach–Zehnder interferometry. Applied Optics. Jun 20 2018; 57 (18):5057-5067 - 36.
Wang Q, Meng H, et al. Optical fiber temperature sensor based on a Mach-Zehnder interferometer with single-mode-thin-core-single-mode fiber structure. Review of Scientific Instruments. Jan 1 2020; 91 (1):015006 - 37.
Zhu J, Huang S, Lv W, Zhou H. Study on the measurement of temperature field using laser holographic interferometry. Frontiers in Energy. Mar 2011; 5 (1):120-124 - 38.
Keren E, Bar-Ziv E, Glatt I, Kafri O. Measurements of temperature distribution of flames by moiré deflectometry. Applied Optics. Dec 15 1981; 20 (24):4263-4266 - 39.
Shakher C, Nirala AK. A review on refractive index and temperature profile measurements using laser-based interferometric techniques. Optics and Lasers in Engineering. Jun 1 1999; 31 (6):455-491 - 40.
Stella A, Guj G, Giammartini S. Measurement of axisymmetric temperature fields using reference beam and shearing interferometry for application to flames. Experiments in Fluids. Jul 2000; 29 (1):1-2 - 41.
Singh P, Faridi MS, Shakher C. Measurement of temperature of an axisymmetric flame using shearing interferometry and Fourier fringe analysis technique. Optical Engineering. Feb 2004; 43 (2):387-392 - 42.
Shakher C, Daniel AP. Talbot interferometer with circular gratings for the measurement of temperature in axisymmetric gaseous flames. Applied Optics. Sep 1 1994; 33 (25):6068-6072 - 43.
Khramtsov PP, Penyazkov OG, Shatan IN. Temperature measurements in an axisymmetric methane–air flame using Talbot images. Experiments in Fluids. Feb 2015; 56 (2):1-9 - 44.
Thakur M, Vyas AL, Shakher C. Measurement of temperature and temperature profile of an axisymmetric gaseous flames using Lau phase interferometer with linear gratings. Optics and Lasers in Engineering. Oct 1 2001; 36 (4):373-380 - 45.
Pandey PK, Kumar M, Kumar V, Shakher C. Measurement of temperature and temperature profile of wick stabilized micro diffusion flame under the effect of magnetic field using digital speckle pattern interferometry. Optical Engineering. Jan 2017; 56 (1):014106 - 46.
Kumar V, Shakher C. Measurement of temperature and temperature profile of candle flame using holo-shear lens and Fourier fringe analysis technique. Optical Engineering. Aug 2015; 54 (8):084105 - 47.
Kumar V, Rastogi V, Agarwal S, Shakher C. Holo-shear lens based interferometer for measurement of temperature distribution and fluctuation of temperature in micro flame. In: Holography, Diffractive Optics, and Applications IX 18 November 2019; (Vol. 11188). Hangzhou, China: SPIE; pp. 244–250 - 48.
Kumar V, Rastogi V, Agarwal S, Shakher C. Investigation of temperature profile and temperature stability of micro diffusion flame under the influence of magnetic field by use of a holo-shear lens-based interferometer. Optical Engineering. Jun 2020; 59 (6):064107 - 49.
Sharma S, Sheoran G, Shakher C. Digital holographic interferometry for measurement of temperature in axisymmetric flames. Applied Optics. 2012; 51 (16):3228-3235 - 50.
Kumar V, Kumar M, Sharma S, Shakher C. Measurement of temperature profile around heated wire using digital holography. In: Osten W, editor. Fringe. Berlin, Heidelberg: Springer; 2013. pp. 497-502 - 51.
Doleček R, Psota P, Lédl V, Vít T, Václavík J, Kopecký V. General temperature field measurement by digital holography. Applied Optics. Jan 1 2013; 52 (1):A319-A325 - 52.
Kumar V, Kumar M, Shakher C. Measurement of natural convective heat transfer coefficient along the surface of a heated wire using digital holographic interferometry. Applied Optics. Sep 20 2014; 53 (27):G74-G83 - 53.
Kumar V, Kumar M, Shakher C. Temperature measurement of axi-symmetric butane diffusion flame under the influence of upward decreasing gradient magnetic field using digital holographic interferometry. In SPECKLE 2015: VI International Conference on Speckle Metrology 24 August 2015; (Vol. 9660). Guanajuato, Mexico: SPIE; pp. 99–106 - 54.
Kumar V, Shakher C. Study of heat dissipation process from heat sink using lensless Fourier transform digital holographic interferometry. Applied Optics. Feb 20 2015; 54 (6):1257-1266 - 55.
Agarwal S, Kumar V, Shakher C. Temperature measurement of wick stabilized micro diffusion flame under the influence of magnetic field using digital holographic interferometry. Optics and Lasers in Engineering. Mar 1 2018; 102 :161-169 - 56.
Kumar V, Shakher C. Visual and quantitative investigation on heat flow performance from heat sinks using digital holographic interferometer. In: Holography, Diffractive Optics, and Applications IX 18 November 2019; (Vol. 11188). Hangzhou, China: SPIE; pp. 230–237 - 57.
Kumar V, Shakher C. Digital holography for local heat flux measurement along the surface of heated wire. In CLEO: QELS_Fundamental Science 5 May 2019; San Jose, California, United States: Optica Publishing Group; pp. JW2A-1 - 58.
Rastogi V, Agarwal S, Kumar V, Shakher C. Holographic optical element based digital holographic interferometer for the study of macro flames, micro flames and their temperature instability. Optics and Lasers in Engineering. Nov 1 2019; 122 :29-36 - 59.
Quan C, Thakur M, Tay CJ. Lau phase interferometry with a vibrating object. Optik. Jan 15 2006; 117 (1):9-14 - 60.
Kaufmann GH, Galizzi GE. Speckle noise reduction in television holography fringes using wavelet thresholding. Optical Engineering. Jan 1996; 35 (1):9-14 - 61.
Sharma A, Sheoran G, Jaffery ZA. Improvement of signal-to-noise ratio in digital holography using wavelet transform. Optics and Lasers in Engineering. Jan 1 2008; 46 (1):42-47 - 62.
Schnars U, Jüptner WP. Digital recording and numerical reconstruction of holograms. Measurement Science & Technology. Aug 7 2002; 13 (9):R85 - 63.
Schnars U, Jüeptner W. Digital Holography: Digital Hologram Recording, Numerical Reconstruction, and Related Techniques. Berlin Heidelberg GmbH, Germany: Springer; 2005 - 64.
Wagner C, Seebacher S, Osten W, Jüptner W. Digital recording and numerical reconstruction of lensless Fourier holograms in optical metrology. Applied Optics. Aug 1 1999; 38 (22):4812-4820 - 65.
Jeong K, Turek JJ, Nolte DD. Speckle fluctuation spectroscopy of intracellular motion in living tissue using coherence-domain digital holography. Journal of Biomedical Optics. May 2010; 15 (3):030514 - 66.
Yu X, Hong J, Liu C, Kim MK. Review of digital holographic microscopy for three-dimensional profiling and tracking. Optical Engineering. Apr 2014; 53 (11):112306 - 67.
Wetzel M, Herman C. Accurate measurement of high-speed, unsteady temperature fields by holographic interferometry in the presence of periodic pressure variations. Measurement Science & Technology. Jun 1 1998; 9 (6):939 - 68.
Hossain MM, Shakher C. Temperature measurement in laminar free convective flow using digital holography. Applied Optics. Apr 1 2009; 48 (10):1869-1877 - 69.
Imbe M. Radiometric temperature measurement by incoherent digital holography. Applied Optics. Feb 10 2019; 58 (5):A82-A89 - 70.
Sheoran G, Anand A, Shakher C. Lensless Fourier transform digital holographic interferometer for diffusivity measurement of miscible transparent liquids. Review of Scientific Instruments. May 6 2009; 80 (5):053106 - 71.
Agarwal S, Kumar M, Kumar V, Shakher C. Analysis of alcohol-water diffusion process using digital holographic interferometry. In: SPECKLE 2015: VI International Conference on Speckle Metrology 24 August 2015; (Vol. 9660). Guanajuato, Mexico: SPIE; pp. 135–141 - 72.
Desse JM, Picart P, Tankam P. Digital three-color holographic interferometry for flow analysis. Optics Express. Apr 14 2008; 16 (8):5471-5480 - 73.
Gopalan B, Katz J. Turbulent shearing of crude oil mixed with dispersants generates long microthreads and microdroplets. Physical Review Letters. Feb 1 2010; 104 (5):054501 - 74.
Hossain MM, Mehta DS, Shakher C. Refractive index determination: an application of lensless Fourier digital holography. Optical Engineering. Oct 2006; 45 (10):106203 - 75.
Wang Q, Zhao J, Jiao X, Di J, Jiang H. Visual and quantitative measurement of the temperature distribution of heat conduction process in glass based on digital holographic interferometry. Journal of Applied Physics. May 1 2012; 111 (9):093111 - 76.
Zhang Y, Zhao J, Di J, Jiang H, Wang Q, Wang J, et al. Real-time monitoring of the solution concentration variation during the crystallization process of protein-lysozyme by using digital holographic interferometry. Optics Express. Jul 30 2012; 20 (16):18415-18421 - 77.
Desse JM, Picart P. Stochastic digital holography for visualizing inside strongly refracting transparent objects. Applied Optics. Jan 1 2015; 54 (1):A1-A8 - 78.
Rastogi V, Kumar V, Dubey SK, Khan GS, Shakher C. Noncontact temperature measurement of human hand skin using volume phase holographic optical element based digital holographic interferometer. Optics and Lasers in Engineering. Apr 1 2022; 151 :106886 - 79.
Kris TM. Frequency analysis of digital holography with reconstruction by convolution. Optical Engineering. 2002; 41 (8):1829-1839 - 80.
Matsushima K, Schimmel H, Wyrowski F. Fast calculation method for optical diffraction on tilted planes by use of the angular spectrum of plane waves. Journal of the Optical Society of America A. Sep 1 2003; 20 (9):1755-1762 - 81.
Kumar V, Khan GS, Shakher C. Phase contrast imaging of red blood cells using digital holographic interferometric microscope. In Third International Conference on Applications of Optics and Photonics 22 August 2017; (Vol. 10453). Faro, Portugal: SPIE; pp. 678–684 - 82.
Kumar V, Shakher C. Testing of micro-optics using digital holographic interferometric microscopy. In 2016 4th International Conference on Photonics, Optics and Laser Technology (PHOTOPTICS) 27 February 2016; Rome, Italy: IEEE; pp. 1–6 - 83.
Kumar V, Shakher C. Characterization of micro-lenslet array using digital holographic interferometric microscope. In: Ribeiro PA, Raposo M, editors. Optics, Photonics and Laser Technology. Springer Nature, Switzerland AG: Springer, Champions; 2018. pp. 25-45 - 84.
Goldstein RM, Zebker HA, Werner CL. Satellite radar interferometry: Two-dimensional phase unwrapping. Radio Science. Jul 1988; 23 (4):713-720 - 85.
Mudawar I. Two-phase microchannel heat sinks: theory, applications, and limitations. Journal of Electronic Packaging. 2011; 133 (4):041002 - 86.
Farrell PV, Hofeldt DL. Temperature measurement in gases using speckle photography. Applied Optics. Apr 1 1984; 23 (7):1055-1059