The main geometrical dimensions of mixers and operation conditions
Abstract
The mass transfer process is the subject of many experimental studies in chemical engineering and also one of the most commonly used processes. Unfortunately, the mechanism of this process is still not fully understood, especially when nonstandard methods of intensification of mass transfer are used. In this investigation, the use of an alternating magnetic field action (AMFs) causing mass transfer was taking into consideration. As a result of the flow of electrically conductive fluid near the alternating magnetic field, electromagnetic forces can be generated within the liquid. These forces arise as a result of interaction between the magnetic field and the electric current. They are responsible for the rotation and consequently cause movement of the fluid on which they act. Therefore, there is the possibility of using these properties in the construction of a nonintrusive mixing stirrer.
Keywords
- Rotating magnetic field
- mixing energy
- mass transfer
1. Introduction
The mass transfer process is the subject of many experimental studies in chemical engineering and also one of the most commonly used processes. Unfortunately, the mechanism of this process is still not fully understood, especially when nonstandard methods of intensification of mass transfer are used. In this investigation, the use of an alternating magnetic field action (AMFs) causing mass transfer was taken into consideration. In many industries, static magnetic fields (MSSF) are mainly used as magnetic separators or electromagnetic brakes, while transverse rotating magnetic fields (TRMFs) are used in asynchronous electric motors or as an electromagnetic stirrer. As a result of the flow of electrically conductive fluid near the alternating magnetic field, electromagnetic forces can be generated within the liquid. These forces arise as a result of interaction between the magnetic field and the electric current, and they are called Lorentz or Laplace forces. They are responsible for the rotation and consequently cause movement of the fluid on which they act. Therefore, there is the possibility of using these properties in the construction of a nonintrusive mixing stirrer. The use of rotating magnetic field (RMF) acting on the conductive fluid is mainly used in the crystallization process and other processes in chemical engineering.
The application of the TRMF in chemical engineering processes has many advantages. Instead of using a mechanical mixer to increase the process intensity, it is possible the use static or rotating magnetic field (RMF). Generally, it is known that small particles having magnetic properties are arranged along the magnetic field lines and that they are also moving with movement of the magnetic field. The use of TRMF creates the possibility of using these particles and also controlling the hydrodynamic state of the magnetodispersion. Magnetic particles in the system, which are subjected to the influence of magnetic field, will behave as active microstirrers. Usually, the mixing process is carried out in the mixing tank or stirred vessel. The process performance can be evaluated on the basis of energy consumption and mixing time. However, when choosing the proper mixing equipment, the mixing time and energy of the system should not be considered separately. The minimum value of the mixing energy determines the optimum process conditions. Therefore, it is desirable to know value of the mixing energy during the design of the mixing device.
The aim of this study are to determine the mixing time, the power consumption and the mixing efficiency in the mass transfer process (dissolution of NaCl-cylindrical sample) that is induced under the action of RMF. The present study compared the mass transfer coefficient of two reactor types: RMF mixer and stirred tank reactor (STR) equipped with Rushton turbine. It is decided that in the present report, the influence of the mixing system consisting of the RMF generator or the mechanical stirrer on the mass transfer process is described by applying the nondimensional parameters, like Sherwood, Schmidt, and Reynolds numbers, and mixing energy. Mixing energy was calculated as a product of the mixing time and power input to the mixing liquid. These dimensionless numbers allow quantitative representation and characterization of the influence of the hydrodynamics state under the various hydrodynamic conditions on the mass transfer rate. The dimensionless groups are used to establish the effect of the various types of the mixing process on this operation in the form of the dimensionless correlation. Moreover, the comparison of the amount of energy input to reach the same mass transfer rate with two different devices (RMF mixer and STR) is discussed.
2. Theoretical background
There is one way of looking at the intensity of the external mass transfer, namely, the criterion of Sherwood,
where
In Eq. (1), a major role in mass transport has the following dimensionless numbers: Sherwood and Schmidt numbers. The first one (Sherwood number) describes the ratio of convective to diffusive mass transport [2], while the second one (Schmidt number) indicates physical parameters important for the analyzed setup. Furthermore, the Schmidt number is also the measure of the mass and momentum transport relative effectiveness by diffusion. In the basic Eq. (1), except the Sherwood and Schmidt numbers, additionally the Reynolds number can be found. The Reynolds number represents the ratio of convective to viscous momentum transport. The value of the Reynolds number determines the existence of laminar or turbulent regime of fluid flow. For small values of the Reynolds number, viscous forces are sufficiently large relative to inertia forces, and we have laminar flow. With increasing values of the Reynolds number, viscous effects become progressively less important relative to inertia effects, and we have turbulent flow.
It is clear that Eq. (1) in present form cannot be practical use. First, it must be rendered quantitative. It can be achieved by assuming that the functional relation is in the following form [3,4]:
This is commonly known that the coefficient of the mass transfer process can be calculated using three dimensionless groups: Sherwood, Reynolds, and Schmidt numbers. Using Eq. (2), it is possible to combine a lot of data obtained from experimental measurements for many different operations. The
The exponent upon of the Schmidt number is to be 0.33 [6–10] as there is some theoretical and experimental evidence for this value [11], although reported values vary from 0.56 [12] to 1.13 [13].
It should be also noted that for the mass transfer process under natural convection conditions, i.e., then, when the Reynolds number is unimportant, the general expression for the mass transfer has the following form:
However, in the presented report, the mass transfer process proceeds under convective conditions; therefore, it is described by means of the following relationships:
The above dimensionless groups were calculated with the psychical properties of the tested fluid in the temperature 20°C. In this paper, we present results of the mass transfer process using similar dimensionless groups. In this case, the relationship between Sherwood number and two other numbers, which inform about hydrodynamic conditions in the system, Reynolds and Schmidt numbers, was slightly modified. The Reynolds numbers for the process realized with using the STR or RMF were defined by the following equations, respectively:
where
In order to establish the effect of the hydrodynamic conditions on the mass transfer process in the tested experimental setups, we propose the following relationship:
The effect of mass transfer process can be described by using the variable
One of the parameters that describe the mixing process is the mixing time. This parameter determines the time needed to obtain required level of the mixture homogeneity. Therefore, the mixing time is a contractual value and depends on the mixture homogeneity definition. The homogenization time is often describe with a nondimensional module, defined as a required rotational impeller speed to obtain expected value of the mixing system homogeneity. Mixing time can be expressed as follows:
To measure the level of the mixture homogeneity, the techniques based on put the system out of equilibrium are frequently used. Afterward, the time in which system returns to the equilibrium state is measured. Usually, one of the two techniques is used: a method that relies on the conductivity measurements [14–17] or thermal method [18,19]. Both of them are characterized by easy conduct of the experiment, and there are also relatively cheap. The conductometric method is based on adding to the system impulse influencing the change in the electrical conductivity of the mixed liquor. The second method is based on adding to the system signal in the form of the hot liquid. In this work, the thermal method of put the system out of equilibrium was used.
Another important parameter that determines the system cost of the process is the power consumption. This parameter can be used as a measure of energy consumption in the process. Power consumption for the mixing process can be calculated on the basis of the relationship between dimensionless number [20,21] as follows:
where Newton number is defined as
In the case of using a mechanical stirrer,
In the case of influence, the rotating magnetic field
Where
The Reynolds numbers for the process realized with using the STR or RMF were defined before (Eqs. 6–8).
A parameter that connects both mixing time and power consumption is a mixing energy [22–26]. This parameter is defined as the product of the mixing time in relation to the volume of mixed liquor and power input:
This parameter can be presented as a dimensionless number:
By calculating the dimensionless value of the mixing energy, it is possible to compare the efficiency of mixing between different systems.
To calculate dimensionless mixing energy for the both systems (Eq. 16), some relationships must be designated. First, from the measured experimental data of the mixing time, a function must be plotted. Then the approximation curve must be designated in the form of the following equations:
Second, from the measured experimental data of the power consumption, a function given by the Eq. (11) must be plotted. Then the approximation curve must be designated in the form of the following equations:
Considering the resulting equations (Eq. 17) and rearranging terms to Eq. (10), the following equations were obtained:
Substituting Eq. (12) into Eq. (18), we have
The obtained Eqs. (19) and (20) are then substituted in Eq. (15), and consequently we have the following relationships:
Transforming Eq. (21), it may be given in the dimensionless forms, as follows:
3. Dissolution solid body in two reactor types
3.1. Literature survey
Many processes in chemical and related industries are carried out in heterogeneous solid–liquid systems. One of the most commonly used processes is the dissolution of a solid body in a liquid. The dissolution process of a solid body in a liquid can occur spontaneously or it can be intensified. One of the simplest methods of the mass transfer intensification is dissolution in mechanical mixers, i.e., apparatus with moving impellers [27,28]. Using the mechanical impeller should provide increase of the liquid turbulence, particularly at the boundary of the phases. The case of using mechanical mixers kinetic of the solid body dissolution depends on hydrodynamic conditions occurring inside the liquid volume, whereas hydrodynamics of the liquid depends on geometric configuration of the device. This is why the choice of the suitable impeller and mixing tank dimensions to the stirred medium, the type of the process, and the purpose of what we want to achieve are important issues. Except the result of research carried out for the well-known mechanical agitators, new constructional proposals of the mechanical mixers for performing solid dissolution process in a liquid can be found in the literature. This may have a positive effect on the mass transfer process, for example, using a reciprocating agitator [10,29–32]. Among other methods that are commonly used to intensify solid dissolution, a liquid pulsation [33], electrical discharges [34], other physical methods of the interaction [35], and dissolution on the solid or fluidized bed [36] can be found. In the case of dissolution process with chemical reaction an ultrasound can be used to the intensification [37–39]. In the last few years, a growth of interest in using of the magnetic fields in processes and unit operations in the scientific community was observed. Externally applied static magnetic field was used primarily to intensify the process of crystal growth [40,41] or during solidification of metal alloys [42,43]. The rotating magnetic field can be successfully used in the crystallization process [44–47], fluidization [48,49], metallurgy [50,51], or even to increase the intensity of the dissolution process, as an alternative for mechanical mixing. This type of magnetic field induces azimuthal forces, which are time averaged. If the stirred liquid is magnetically susceptible, then azimuthal forces make a circumferential flow. Lines of the magnetic field rotate in a horizontal direction with rotation frequency of the field,
3.2. Preparation of samples
As a solid body, the NaCl-cylindrical samples were used. To obtain suitable samples, i.e., samples that are dissolving in uniform manner, all of them were subjected to hardening process. First, raw rock salt cylinders were placed in a container filled up with a NaCl saturated solution. Second, after 24 h, the samples were pulled out and left dry. This process was repeated two times to obtain homogeneous and smooth surface of the cylindrical samples. A short thread stainless steel rod was glued to the top surface of the sample, which allows to mount it in a selected position in volume of the stirred liquid. Finally, the samples were securing at the bottom and top surface of the cylinder by applying a thin layer of glue on it. The prepared samples were used to perform the measurements.
Before the solubility measuring, the samples were hardened again in saturated salt solution during 60 s and then dried with paper. It was necessary because the dry samples may have to collect moisture from the stirred water, which could have a negative impact on the solubility process. Before each measurement the samples were weighed. Moreover, their height and diameter were measured. The diameter of the sample was measured at five different high levels located in equal increments and taken three times for different angular position of the sample. The location of the places where the diameter was measured is schematically shown in Figure 1.
Before the measurements in the magnetic stirrer were started, the magnetic field at a set point value of operating frequency of the stator was turned on. In the case of measurements for a mechanical mixer, first the impeller was set in motion on the requested rotation speed. Second, the conductivity measurement was switched. Then the sample was placed in a container filled up with tap water. In the case of a magnetic mixer, the sample was placed at the mid-height of electromagnetic laminations, where the most intensive magnetic field induction generated in a container takes place. Based on the literature data [54], it was found that it is also the place where the mass transfer process should proceed the fastest. The typical examples of the magnetic induction distribution in the form of the contours were presented in Figure 2.
Every sample was dissolved once in short time equal to 5 s and then was pulled out of the system, dried by using the paper, measured, and weighed. For each sample, 13 replicates were performed. The number of repetition dissolution of the sample was chosen in a way to get appearance of the first pinholes. After the series of measurements, the data from multiparameter sensors were read. The water inside the container was replaced with a new one after every measurement series, keeping its temperature at constant level (
3.3. Experimental setup
The first measurements of the NaCl-solid body dissolution were carried out in the RMF generator, which is shown in Figure 3. This experimental apparatus consists of a cylindrical glass container (2), a.c. transistorized inverter (3), and multifunctional computer meter (CX-701, Elmetron, Gliwice, Poland) (4). All of these elements are connected to the computer (5). The RMF generator was constructed of the stator, which was supplied from an electric motor with 50 Hz three-phase alternating current. The process parameters of the RMF generator were controlled using the special software. By controlling the inverter via a computer, it was possible to change the frequency of rotating magnetic field. In this case, the frequency was changed in the range of
The second experimental apparatus are shown in Figure 5. It was the same glass vessel as in the first system; however, in this case, the mixing process was realized by using the mechanical high-speed impeller (Rushton disc turbine). The diameter of the agitator was equal to
3.4. Mixing time and power consumption measurements
The mixing time measurements for two systems were performed. The first mixer was under the action of the rotating magnetic field, and the second was equipped with the Rushton turbine mechanical impeller. The stirred vessel was filled up with a tap water (density 1000 kg m–3, viscosity 1.002 mPa s, temperature 22–23°C). The geometric dimensions and process parameters for both systems are shown in Table 1.
|
|
Geometrical dimensions of mixer | |
Vessel diameter, m | 0.235 |
Agitator diameter, m | 0.076 |
Time of dissolution, s | 5 |
Height of liquid level in vessel, m | 0.42 |
Operating conditions | |
The frequency of rotation agitator, s-1 | 0 – 3 |
Input power of agitator, W | 0.002 - 26 |
Poles pair of generator RMF | 2 |
The frequency of RMF, Hz | 2 – 120 |
Input power of generator RMF, W | 1 – 1050 |
Average diameter of sample, m | 0.031 |
Average height of sample, m | 0.074 |
Impulse temperature, oC | 85 |
Electrical conductivity, (Ωm)-1 | 2.5·10-4 |
In this investigation, a thermal method was used to mixing time determination. First, a specific volume of the liquid with much higher temperature comparing to the mixed liquid was added to the system. As a tracer, a 0.3-dm3 tap water with temperature equal to 85°C was used. Then changes of the liquid temperature were measured by using special experimental apparatus. It was an LM35 temperature sensor with measuring test card, which can process an analog signal in the form of the voltage to a digital signal. The voltage signal from the temperature probe was recorded at a frequency of 0.01 s. When the measurement was finished, a content of the glass container was poured out, and the vessel was filled up again with a new tap water characterized by the initial temperature. The mixing process was regarded as complete when the temperature fluctuations on one level were established. In this experiment, the end point was reached, when changes of the temperature at two measurement points were less than ±5% of the overall temperature increase. The mixing time,
where
Additionally, measurements of the active power input to the test system with a mechanical stirrer and RMF were performed. In the case of the mechanical stirrer, it was possible to read power consumption directly from the digital display stirrer drive, whereas in the case of the system comprising an RMF generator, it has to be measured by using the electricity meter (type C-52 Pafal), located between the magnetic agitator and the a.c. transistorized inverter. The data that were collected were then graphically shown in Figure 7, in the form of the power change depending on an increasing rate of the rotational impeller speed. A similar relationship for the RMF is shown in Figure 8, except that in this case, the power depends on the frequency of magnetic field rotation change.
4. Results and discussion
4.1. Influence of the Rushton turbine and the RMF on the mass transfer
The experimental results of the solid body dissolution are graphically shown in Figures 9 and 10. In Figure 9, results of the measurements for the mixing tank equipped with Rushton turbine impeller were presented. Furthermore, in the picture, an approximation of the experimental results and the proposed relationship were also presented. Analogous graph was prepared for the magnetic mixer and shown in Figure 10. Analyzing the plots, it was found that values of the mass transfer coefficients in the tested systems are depended on the Reynolds number. Additionally, a significant effect of the mixing method on the mass transfer process was observed. The higher impact of the Reynolds number value on the mass transfer coefficients in the STR was observed. In both systems, the mass transfer rate increased with increasing value of Reynolds number. However, the slope of the approximation curve was bigger in the case of the mechanical mixer than that in the case of the magnetic mixer. The proposed relationships were
4.2. Power characteristics for the Rushton turbine and the RMF
Power characteristics for both systems in Figures 11 and 12 were presented. As it could be seen, values of the power number for the STR system were much lower than those in the magnetic mixer. It is caused by the fact that in the case of the RMF generator, the power consumption was significantly higher, which consequently affects the calculated values of the Ne number. Based on the slope of the proposed approximation curve, in the case of mechanical mixer with increase value of the rotational impeller speed, the value of the Ne number was slightly decreasing. In the tested range, the proportionality
4.3. Mixing time characteristics for the Rushton turbine and the RMF
In present consideration, the dimensionless mixing time was defined as
The mixing time may be analytically described using the relationship between the dimensionless mixing time and the Reynolds number. The experimental data obtained for the systems with the RMF generator or Rushton turbine in log–log graphs were presented (Figures 13 and 14). Analyzing the results shown in the graphs, it was found that values of the dimensionless mixing time decreased with increasing Reynolds number in both systems. Comparing results for both systems, it was found that smaller values of the dimensionless mixing time in the mixing process realized with using a Rushton turbine were obtained. Based on the curve slope, it can be assumed that the process using a mechanical impeller proceeds more intensively than that under the action of RMF. It should be noted that in the magnetic mixer, the process proceeds as a laminar, while the mechanical impeller induces a turbulent regime of the flow. According to that, using of an RMF mixer can be useful in a mixing process, when a turbulent flow of the fluid cannot be achieved, even if it will cause an increasing mixing time. An example can be here a bioprocess, where high shear forces connected with a turbulent flow can have a destructive impact on the microorganisms.
Additionally, values of the power number obtained from the experimental measurements and calculated on the basis of an approximating equation for the process under the action of the RMF are presented in the Figure 15 and compared.
5. Mixing energy
As mentioned before, an evaluation of the mixing process realized in different geometrical systems with a mixing energy parameter can be performed. Characteristics of the dimensionless mixing energy for both systems were graphically presented in Figures 16 and 17. As follows from the graphical analysis, lower values of the dimensionless mixing energy in the case of RT using were noted. The conclusion is that the rotational movements of mechanical impeller are more effective for the liquid mixing than the magnetic mixer in the whole tested range of the rotational impeller speed and RMF frequency. Nevertheless, the mixing process under the action of RMF is nonintrusive, which pose a huge advantage this type of mixer.
6. Conclusion
Obtained in this consideration, experimental and calculated results present an interesting effect of the rotating magnetic field and stirred tank reactor applications in the mass transfer process. Analyzing the obtained results reveals the following conclusions:
Values of the mass transfer coefficients increases with an increasing value of the rotational agitator speed and the magnetic field intensity. In the laminar regime of the flow, a stronger impact on the solid body dissolution in the case of magnetic mixer was observed, while in the turbulent regime of the flow, better results in the stirred tank with mechanical RT impeller were obtained.
In the STR system, values of the power number were much lower than those in the magnetic mixer. Based on the proposed approximation curves slope, with the increasing value of the rotational impeller speed or RMF frequency, the value of the
In both systems, the dimensionless mixing time decreased with increasing value of the Reynolds number. However, smaller values of the dimensionless mixing time in the mixing process realized with using a Rushton turbine were obtained. It must therefore be concluded that the process carried out with using a mechanical impeller proceeds more intensively than that under the action of RMF.
On the basis of the dimensionless mixing energy comparison for both systems, it was found from the economical point of view that using of the rotating magnetic field is less profitable due to high power consumption. In the future, additional experimental measurements should be carried out for the system with the RMF generator in order to find a way to reduce the calculated values of dimensionless mixing energy. One of the possibilities is using of the magnetic particles, which can be added to the mixed liquid.
In order to better understand the mechanism of the mass transfer process under the action of the rotating magnetic field further studies, both theoretical and experimental should be carried out.
Nomenclature
Pa; active power; W
Greek letters
(
Dimensionless number
Ne; Newton number
Re; Reynolds number
Sc; Schmidt number
Sh; Sherwood number
Θ; mixing time number
Subscripts
0; reference value
L; liquid
P; conductivity probe
S; sample
Abbreviations
mix; Mixing
RMF; rotating magnetic field
STR; Rushton turbine
References
- 1.
Incropera, F.P., DeWitt, D.P. Fundamentals of Heat and Mass Transfer. USA: John Wiley & Sons Inc.; 2011. ISBN: 978-0470-50197-9 - 2.
Basmadjian, D. Mass Transfer. Principles and Applications.USA: CRC Press LLC; 2004. ISBN 9780203503140 - 3.
Bird, R.B.; Stewart, W.E., Lightfoot, E.N. Transport Phenomena.USA: Wiley; 1966. ISBN: 978-0471073925 - 4.
Kays, W.M., Crawford, M.E. Convective Heat and Mass Transfer. USA: McGraw-Hill; 1980. ISBN 9780070334571 - 5.
Garner, F.H., Suckling, R.D. Mass transfer form a soluble solid sphere. American Institute of Chemical Engineers Journal. 1958;4(1):114–124. DOI: 10.1002/aic.690040120 - 6.
Condoret, J.S.; Riba, J.P., Angelino, H. Mass transfer in a particle bed with oscillating flow. Chemical Engineering Science. 1989;44(10):2107–2111. DOI:10.1016/0009-2509(89)85145-0 - 7.
Jameson, G.J.Mass (or heat) transfer form an oscillating cylinder. Chemical Engineering Science. 1964;19:793–800. DOI: 10.1016/0009-2509(64)85090-9 - 8.
Lemcoff, N.O., Jameson, G.J. Solid–liquid mass transfer in a resonant bubble contractor. Chemical Engineering Science. 1975;30:363–367. DOI: 10.1016/0009-2509(75)85001-9.3 - 9.
Noordsij, P., Rotte, J.W. Mass transfer coefficients to a rotating and to a vibrating sphere. Chemical Engineering Science. 1967;22:1475–1481. DOI: 10.1016/0009-2509(67)80073-33 - 10.
Tojo K., Miyanami K., Minami I. Vibratory agitation in solid–liquid mixing. Chemical Engineering Science. 1981;36:279–284. DOI: 10.1016/0009-2509(81)85006-3 - 11.
Sugano, Y., Rutkowsky, D.A. Effect of transverse vibration upon the rate of mass transfer for horizontal cylinder. Chemical Engineering Science. 1968;23:707–716. DOI: 10.1016/0009-2509(68)85005-5 - 12.
Wong, P.F.Y., Ko, N.W.M., Yip, P.C. Mass transfer from large diameter vibrating cylinder. Transactions of the Institution of Chemical Engineers. 1978;56(3):214–216. ISSN: 0371-7496 - 13.
Lemlich, R., Levy, M.R. The effect of vibration on natural convective mass transfer. American Institute of Chemical Engineers Journal. 1961;7:240–241. DOI: 10.1002/aic.690070214 - 14.
Woziwodzki Sz., Broniarz-Press L., Ochowiak M. Effect of eccentricity on transitional mixing in vessel equipped with turbine impellers. Chemical Engineering Research and Design. 2010;88(12):1607–1614.DOI:10.1016/j.cherd.2010.04.007 - 15.
Kuzmanić N., Ljubičić B. Suspension of floating solids with up-pumping pitched blade impellers; mixing time and power characteristics. Chemical Engineering Journal. 2001;84(3):325–333.DOI: 10.1016/S1385–8947(00)00382-X - 16.
Kuzmanić N., Žanetić R., Akrap M. Impact of floating suspended solids on the homogenisation of the liquid phase in dual-impeller agitated vessel. Chemical Engineering Process. 2008;47(4):663–669. DOI: 10.1016/j.cep.2006.12.010 - 17.
Delaplace G., Leuliet J.C., Relandeau V. Circulation and mixing times for helical ribbon impellers. Review and experiments. Experiments in Fluids. 2000;28:170–182. DOI: 10.1007/s003480050022 - 18.
Karcz J., Cudak M., Szoplik J. Stirring of a liquid in a stirred tank with an eccentrically located impeller. Chemical Engineering Science 2005;60(8–9):2369–2380. DOI: 10.1016/j.ces.2004.11.018 - 19.
Masiuk S. Mixing time for a reciprocating plate agitator with flapping blades. Chemical Engineering Journal 2000;79(1):23–30. DOI: 10.1016/S1385-8947(00)00141-8 - 20.
Zlokarnik M. Stirring—Theory and Practice. Weinheim: Wiley-VCH Verlag; 2001. ISBN 978-3-527-29996-3 - 21.
Harnby N., Edwards M.F., Nienow A.W. Mixing in the Process Industries. 2nd ed.UK: Butterworth-Heinemann, 2000. - 22.
Rakoczy R. Mixing energy investigations in a liquid vessel that is mixed by using a rotating magnetic field. Chemical Engineering and Processing. 2013;66:1–11. DOI: 10.1016/j.cep.2013.01.012 - 23.
Masiuk, S., Kawecka-Typek, J. Mixing energy measurements in liquid vessel with pendulum agitators. Chemical Engineering and Processing. 2004;43(2):91–99. DOI: 10.1016/S0255-2701(03)00072-2 - 24.
Masiuk, S., Rakoczy, R., Kordas, M. Comparison density of maximal energy for mixing process using the same agitator in rotational and reciprocating movements. Chemical Engineering and Processing. 2008;47(8):1252–1260. DOI: 10.1016/j.cep.2007.04.004 - 25.
Nienow, A.W. On impeller circulation and mixing effectiveness in the turbulent flow regime. Chemical Engineering Science. 1997;52(15):2557–2565. DOI: 10.1016/S0009-2509(97)00072-9 - 26.
Bouaifi M., Roustan M. Power consumption, mixing time and homogenisation energy in dual-impeller agitated gas–liquid reactors. Chemical Engineering and Processing. 2001;40(2):87–95, DOI: 10.1016/S0255-2701(00)00128-8 - 27.
Hörmann T., SuzziD., Khinast J.G. Mixing and dissolution processes of pharmaceutical bulk materials in stirred tanks: experimental and numerical investigations. Industrial and Engineering Chemistry Research. 2011;50(21):12011–12025. DOI: 10.1021/ie2002523 - 28.
Hartmann H., Derksen J.J., van den Akker H.E.A. Numerical simulation of a dissolution process in a stirred tank reactor. Chemical Engineering Science. 2006;61:3025–3032. DOI: 10.1016/j.ces.2005.10.058 - 29.
Baird M.H.I., Rama Rao N.V., Vijayan S. Axial mixing and mass transfer in a vibrating perforated plate extraction column. Canadian Journal of Chemical Engineering. 1992;70:69–76. DOI: 10.1002/cjce.5450700111 - 30.
Kordas M., Rakoczy R., Grądzik P., Story G. Rozpuszczanie ciała stałego w mieszalniku z mieszadłem wykonującym ruch obrotowy i posuwisto-zwrotny. Inżynieria i Aparatura Chemiczna. 2012;51(6):346–347. (In Polish). - 31.
Masiuk S. Dissolution of solid body in a tubular reactor with reciprocating plate agitator. Chemical Engineering Journal. 2001;83:139–144. DOI: 10.1016/S1385-8947(00)00268-0. - 32.
Masiuk S., Rakoczy R. Power consumption, mixing time, heat and mass transfer measurements for liquid vessels that are mixed using reciprocating multiplates agitators. Chemical Engineering and Processing. 2007;46:89–98. DOI:10.1016/j.cep.2006.05.002 - 33.
NiX., GaoS. Scale-up correlation for mass transfer coefficients in pulsed baffled reactors. Chemical Engineering Journal and the Biochemical Engineering Journal. 1996;63(3):157–166. DOI:10.1016/S0923-0467(96)03120-X - 34.
Coteaţă M., Schulze H.P., Slătineanu L. Drilling of difficult-to-cut steel by electrochemical discharge machining. Materials and Manufacturing Processes. 2011;26(12):1466–1472. DOI: 10.1080/10426914.2011.557286 - 35.
Tai C.Y., Chi-Kao W., Chang M.C. Effects of magnetic field on the crystallization of CaCO3 using permanent magnets. Chemical Engineering Science. 2008;63:5606–5612. DOI: 10.1016/j.ces.2008.08.004 - 36.
Kalaga D.V., Dhar A., Dalvi S.V., Joshi J.B. Particle–liquid mass transfer in solid–liquid fluidized beds. Chemical Engineering Journal. 2014;245:323–341. DOI:10.1016/j.cej.2014.02.038 - 37.
Grénman H., Murzina E., Rönnholm M., Eränen K., Mikkola J., Lahtinen M., et al. Enhancement of solid dissolution by ultrasound. Chemical Engineering and Processing. 2007;46:862–869. DOI:10.1016/j.cep.2007.05.013 - 38.
Kannan A., Pathan S.K. Enhancement of solid dissolution process. Chemical Engineering Journal. 2004;102:45–49. DOI: 10.1016/j.cep.2009.11.004 - 39.
Sandilya K.D., Kannan A. Effect of ultrasound on the solubility limit of a sparingly soluble solid. Ultrasonics Sonochemistry. 2010;17:427–434. DOI:10.1016/j.ultsonch.2009.10.005 - 40.
Dold P., Szofran F.R., Benz K.W. Thermoelectromagnetic convection in vertical Bridgman grown germanium–silicon. Journal of Crystal Growth. 2006;291:1–7. DOI:10.1016/j.jcrysgro.2006.02.055 - 41.
Kao, A., Djambazov, G., Pericleous, K. and Voller, V. Effects of magnetic fields on crystal growth. Proceedings in Applied Mathematics and Mechanics. 2007;7:4140015–4140016. DOI: 10.1002/pamm.200700922 - 42.
Du D., Hou L., Gagnoud A., Ren Z., Fautrelle Y. Cao G., Li X. Effect of an axial high magnetic field on Sn dendrite morphology of Pb–Sn alloys during directional solidification. Journal of Alloys and Compounds. 2014;588:190–198. DOI:10.1016/j.jallcom.2013.11.011 - 43.
Bouabdallah S., Bessaїh R. Effect of magnetic field on 3D flow and heat transfer during solidification from a melt. International Journal of Heat and Fluid Flow. 2012;37:154–166. DOI: 10.1016/j.ijheatfluidflow.2012.07.002 - 44.
Spitzer K.H. Application of rotating magnetic field in Czochralski crystal growth. Progress in Crystal Growth Characterization. 1999;38(1–4):59–71. DOI: 10.1016/S0960-8974(99)00008-X - 45.
Dold P., Benz K.W. Rotating magnetic field: fluid flow and crystal growth applications. Progress in Crystal Growth Characterization of Materials. 1999;38:7–38, DOI 10.1016/S0960-8974(99)00007-8 - 46.
Walker J.S. Bridgman crystal growth with a strong, low-frequency, rotating magnetic field. Journal of Crystal Growth. 1998;192(1–2):318–327. DOI:10.1016/S0022-0248(98)00438-2 - 47.
Yang, M., Ma, N., Bliss, D.F., Bryant G.G. Melt motion during liquid-encapsulated Czochralski crystal growth in steady and rotating magnetic field. International Journal of Heat and Mass Transfer. 2007;28:768–776. DOI: 10.1016/j.ijheatfluidflow.2006.08.001 - 48.
Lu, X.S., Li, H. Fluidization of CaCO3 and Fe2O3 particle mixtures in a transverse rotating magnetic field. Powder Technology. 2000;107:66–78. DOI: 10.1016/S0032-5910(99)00092-3 - 49.
Hristov J. Magnetic field assisted fluidization—dimensional analysis addressing the physical basis. China Particuology. 2007;5(1–2):103–110. DOI:10.1016/j.cpart.2007.03.002 - 50.
Nikrityuk, P.A., Eckert, K., Grundmann, R. A numerical study of unidirectional solidification of a binary metal alloy under influence of a rotating magnetic field. International Journal of Heat and Mass Transfer. 2006;49:1501–1515. DOI: 10.1016/j.ijheatmasstransfer.2005.08.035 - 51.
Willers, B., Eckert, S., Michel, U., Haase, I., Zouhar, G. The columnar-to-equiaxed transition in Pb–Sn alloys affected by electromagnetically driven convection. Materials Science and Engineering A. 2005;402(1–2):55–65, DOI: 10.1016/j.msea.2005.03.108 - 52.
Lu, X.S., Li, H. Fluidization of CaCO3 and Fe2O3 particle mixtures in a transverse rotating magnetic field. Powder Technology. 2000;107:66–78. DOI: 10.1016/S0032-5910(99)00092-3 - 53.
Rakoczy, R., Masiuk, S. Influence of transverse rotating magnetic field on enhancement of solid dissolution process. American Institute of Chemical Engineers Journal. 2010;56:1416–1433. DOI: 10.1002/aic.12097 - 54.
Rakoczy R. Enhancement of solid dissolution process under the influence of rotating magnetic field. Chemical Engineering and Processing: Process Intensification. 2010:49(1):42–50. DOI: 10.1016/j.cep.2009.11.004