Hydrogel Contact Lenses Surface Roughness and Bacterial Adhesion

Written By

Maria Jesus Giraldez and Eva Yebra-Pimentel

Submitted: November 28th, 2011 Published: September 19th, 2012

DOI: 10.5772/48436

Chapter metrics overview

3,923 Chapter Downloads

View Full Metrics

1. Introduction

Contact lenses are a safe and effective mode of vision correction and today’s industry offers wearers the choice of continuous wear, overnight orthokeratology, frequent-replacement or daily-disposable lenses among others. However, despite these options, including different care and maintenance systems, there are still features of contact lenses that could be improved such as possible microbial contamination (Weisbarth et al., 2007).

Microbial keratitis (MK) is a serious complication of contact lens (CL) wear that can lead to vision impairment (Buehler et al., 1992; Catalonotti et al., 2005; Leitch et al., 1998; Mah-Sadorra et al., 2005; Keay et al., 2009). Although the incidence of CL-related MK is only 0.02–0.5% (Cheng et al., 1999; Holden et al., 2005), the use of CL is so wide-spread that the problem may affect several millions of people and must therefore be considered a major health threat.

The CL surface is a suitable substrate for bacterial adhesion and biofilm formation, and can sustain the growth of microorganisms in prolonged contact with the cornea (Elder et al., 1995). In addition, CL wear may impair the immune response of the cornea by distorting its epithelial barrier function, and thus promote MK (Liesegang, 2002). To improve the corneal/CL interface, new soft hydrogel lens materials incorporate several co-polymers, including silicone polymers for increased oxygen permeability and phosphoryl-choline to increase biocompatibility. Further, the new modalities of wear, such as daily disposable (DD) hydrogel CL, avoid the need for regular cleaning and storage, which are known to be an important cause of microbial contamination (Laughlin-Borlace et al., 1998). However, several studies have surprisingly shown that users of DD and silicone hydrogel CL do not show a reduced risk of MK (Dart et al., 2008; Stapleton et al., 2008; Willcox et al., 2010). In effect, in the paper by Dart et al., differences in soft CL design and/or the composing polymer rather than the mode of wear were found to determine susceptibility to MK (Dart et al., 2008).

The process of initial adhesion of bacteria to the CL surface has been extensively examined in terms of the physical and chemical properties of both the bacterial cell and CL surface, such as hydrophobicity and roughness. Thus, the results of several in vivostudies suggest that a rougher CL surface is prone to more extensive bacterial adhesion (Bruinsma et al., 2002; Bruinsma et al., 2003) since imperfections in the lens surface is where deposits are likely to form (Hosaka et al., 1983). Also, depending on the surface thermodynamics, hydrophilic strains seem to preferentially adhere to hydrophilic surfaces, while more hydrophobic strains have a preference for hydrophobic surfaces (Bos et al., 1999; Bruinsma et al., 2001). Apart from lens surface factors, adhesion is also conditioned by features of the bacterial surface including flagella and fimbriae (Fletcher et al., 1993a; Fletcher et al., 1993b; Gupta et al., 1994; Gupta et al., 1996; Willcox et al., 2001; Donlan, 2002; Donlan, 2002; Kogure et al., 1998; Morisaki et al., 1999) or the presence or release of extracellular substances such as polysaccharides, proteins and biosurfactants (Mack et al., 1999; Mack et al., 1996; Mack et al., 1994).

Occasionally, a contact lens wearer will suffer an adverse response to a lens. These problems are frequently caused by bacterial contamination of the contact lens surface, and MK is one of the most feared complications (Patel and Hammersmith, 2008; Stapleton et al., 2008). Contact lenses absorb tear film proteins and lipids and this induces lens contamination and deterioration. Moreover, the build-up of tear film components on contact lenses can cause discomfort and inflammatory complications such as giant papillary conjunctivitis (GPC) (Skotnitsky et al., 2002; Skotnitsky et al., 2006), and this may occur with any type of daily or extended wear lenses (Donshik PC, 2003). This adsorption depends mainly on the contact lens material, and varies according to the tear secretion rate and certain pathological conditions. Research on conventional poly-HEMA-based lens materials has shown that the deposition of lysozyme and albumin depends upon the polymer’s composition (Bohnert et al., 1988), charge (Garrett et al., 2000; Soltys-Robitaille et al., 2001) and water content (Garrett et al., 1999). Silicone-hydrogel materials give rise to different deposition profiles to those associated with the use of conventional poly-HEMA hydrogel lenses in that they induce less protein deposition and more lipid deposition (Jones et al., 2003; Subbaraman et al., 2006; Carney et al., 2008). Surface roughness also need to be considered since deposits are more likely to form on imperfections of the lens surface (Hosaka et al., 1983). It was also previously demonstrated that as surface roughness increases, the biofilm deposited on the lens also increases (Baguet et al., 1995) and that bacterial transfer from a contact lens is determined by the roughness and hydrophobicity of the surface receiving the bacteria (Vermeltfoort et al., 2004).

Further, a smooth surface is essential for the optical quality of a contact lens since reduced scattered light improves the performance of an optical system (Bennett, 1992). Developments in soft contact lens materials continue to be an important issue, since the performance and comfort of a contact lens will depend on the material, its surface architecture and the quality of the lens manufacturing process (Lorentz et al., 2007; Riley et al., 2006; Guillon and Maissa, 2007). In addition, the performance of contact lenses does not remain constant over time and lens surface changes induced by wear will affect their performance and determine a need to replace the lens.

The aim of this chapter was to qualitatively and quantitatively characterize the surfaces of unworn hydrogel contact lenses using Atomic Force Microscopy (AFM) and White Light Optical Profiling (WLOP), and to analyze how these surface characteristics affect on bacterial adhesion.

Advertisement

2. Contact lens surface roughness

2.1. Roughness parameters

The actual geometry of a surface is very complex (Gadelmawla et al., 2002). Even areas considered "very smooth" show a complex mix of geometric features. Surface roughness is becoming increasingly important for applications in many fields (Bennett, 1992). Among other factors, surface roughness of devices in direct contact with living systems will influence their biological reactivity. How a surface is finished is an important factor for a good operation of many types of products, which include optical products (Bennett, 1992), related to engineering (Blunt, 2006), food (Sheen et al., 2008; Wang et al., 2009) and biomedical products (Hooton et al., 2004; Hooton et al., 2006; Linneweber et al., 2007; Lee et al., 2009). The surface of any body or object is the part which interacts with the surrounding environment. Roughness is a biological factor that affects in a molecular scale, the manner in which bacteria adhere to surfaces, above all for initial adhesion. (Mitik-Dineva et al., 2008; Mitik-Dineva et al., 2009). The real geometry of a surface is so complex that only by increasing the number of parameters used can a more accurate description be obtained (Gadelmawla et al., 2002). Surface parameters can be considered as height and shape parameters:

2.1.1. Height parameters

The parameters generally used to quantify roughness include height parameters such as average roughness (Ra), mean-square-roughness (Rms) and Maximum Roughness (Rmax) (Baguet et al., 1993; Guryca et al., 2007; Bhatia et al., 1997; Hinojosa Rivera and Reyes Melo, 2001; Lira et al., 2008; Gonzalez-Meijome et al., 2009; Giraldez et al., 2010a; Giraldez et al., 2010c; Gonzalez-Meijome et al., 2006a). Ra is the average deviation or arithmetic mean of the profile from the mean line; it is universally accepted and is the most used international parameter of roughness. Rms is the standard deviation from the mean surface plane. Although Ra and Rms seem to be the most informative and consistent parameters used to define the surface topography of contact lenses (Gonzalez-Meijome et al., 2006a), they both show a dependency on sample length (Hinojosa Rivera and Reyes Melo, 2001; Kiely and Bonnell, 1997; Kitching et al., 1999). Degree of their variation with sample length could be representative of how homogeneous a surface is in its irregularities distribution. Rmax is the maximum peak-to-valley height identified within the observed area. It could be affected by local imperfections or sample contamination leading to higher values than expected, so material characterization based on this parameter could be unreliable.

2.1.2. Shape parameters

Two statistical parameters of roughness, not generally used to analyze contact lens surfaces, are kurtosis (Rku) and skewness (Rsk). Rku is a measure of the sharpness of the profile about the mean line that provides information on the distribution of spikes above and below the mean line. Thus, spiky surfaces will have a high kurtosis value (Rku > 3) and bumpy surfaces a low value (Rku < 3). Rsk is a measure of the symmetry of the profile about the mean line, giving information on asymmetrical profiles for surfaces with the same values of Ra and Rms. Negative values of Rsk indicate a predominance of troughs, while positive ones are observed for surfaces with peaks. The use of both shape parameters, Rku and Rsk, which serve to distinguish between two profiles with the same Ra and/or Rms, (Gadelmawla et al., 2002) has been reported in several biomedical fields (Hansson, 2000; Olefjord and Hansson, 1993; Yang et al., 2007; Linde et al., 1989; Zyrianov, 2005; Raulio et al., 2008; Szmukler-Moncler et al., 2004; Cehreli et al., 2008). Figure 1 shows the amplitude distributions/shape profiles of two surfaces with a similar Ra but different values of Rsk or Rku (Gadelmawla et al., 2002).

The clinical applications of Rku and Rsk in the contact lens field could be to provide a measure of the susceptibility of a contact lens surface to deposit formation or colonization by microorganisms. Also, different shapes could determine a greater specific surface area, and thus more available active sites for thermodynamic reactions. As two surfaces with similar Ra or Rms could differ in shape (Figure 1), they may also differ in their performance.

Figure 1.

Amplitude distribution curve about the mean line for two surfaces showing similar Ra values but different values of Rsk (a) or Rku (b).

2.2. Surface roughness measurement

A wide variety of methods are available for measuring surface roughness and the light scattering the roughness produces. As commented previously, the apparent surface roughness depends upon the size of the sample area, so in order to provide a better description of the surface roughness, measurements must be acquired for a variety of sample sizes (Kiely and Bonnell, 1997; Kitching et al., 1999); with roughness parameters being calculated for areas with different location and size.

2.2.1. Atomic force microscopy

Atomic force microscopy (AFM) provides detailed information on the surface characteristics of contact lenses (Bhatia et al., 1997; Baguet et al., 1993; Baguet et al., 1995; Bruinsma et al., 2003; Lira et al., 2008; Guryca et al., 2007; Gonzalez-Meijome et al., 2006a; Gonzalez-Meijome et al., 2009; Teichroeb et al., 2008; Maldonado-Codina and Efron, 2005) and is a powerful tool for the high resolution examination of the structure of the hydrated contact lens surface. The method has the advantages that it avoids artefacts due to dehydration and coating (Bhatia et al., 1997; Kim et al., 2002), and allows for non-destructive surface topography and roughness measurements. AFM consists of a microscale cantilever with a sharp tip (probe) that is used to scan the specimen surface. The cantilever is typically made of silicon or silicon nitride with a tip radius of curvature of the order of nanometers. When the tip is brought into the proximity of a sample surface, forces between the tip and the sample cause the cantilever to deflect according to Hooke's law. (Lira et al., 2008) The advantage of AFM over conventional microscopy or scanning electron microscopy (SEM) is the high level resolution offered in three dimensions and that topographic information can be obtained in aqueous, nonaqueous or dry conditions, eliminating the need for sample preparation (e.g., dehydration, freezing or coating). In effect, AFM has proved useful for characterizing tear deposits on worn soft contact lens surfaces (Baguet et al., 1995; Rebeix et al., 2000) or characterizing the rigid gas permeable contact lens surface (Bruinsma et al., 2003). In fact, detailed information about the surface quality of CL has been studied previously by Atomic Force Microscopy (AFM) (Bhatia et al., 1997; Baguet et al., 1993; Baguet et al., 1995; Bruinsma et al., 2003; Gonzalez-Meijome et al., 2006a; Gonzalez-Meijome et al., 2009; Giraldez et al., 2010c) and Cryo-SEM (Gonzalez-Meijome et al., 2006b; Guryca et al., 2007). AFM is a very powerful tool for high resolution examination of hydrated CL surface structure. The method avoids artifacts due to dehydration and coating (Bhatia et al., 1997; Kim et al., 2002). However, when using AFM to analyse CL surface the area of measurement is very small, so it may be answered how representative of the total lens are Ra and Rms obtained by AFM. Cryo-SEM, a modification of the Scanning Electron Microscopy (SEM), requires that the material be frozen in nitrogen before examination (Serp et al., 2002). In hydrogels, this usually means the destruction of the material, which is the main disadvantage of this technique.

2.2.2. White Light Optical Perfilometer

White Light Optical Perfilometer (WLOP) is one of the preferred methods of precision surface characterization in many fields (Caber, 1993; Windecker and Tiziani, 1999; Bennett, 1992; O'Mahony et al., 2003). WLOP is a topographic technique, that as well as AFM, enables the analysis of surface topography and roughness by means of a nondestructively methodology. It is a powerful and well-established technique for non-contact measurement of surface topography for quickly determining three-dimensional surface shape over larger areas at high vertical and moderate lateral resolution (Bennett, 1992; O'Mahony et al., 2003; Novak et al., 2003). Two modes of operation are generally available for the optical profilers. For smooth surfaces the phase-shifting integrating bucket technique (PSI) is generally used since it gives sub-nanometer height resolution capability. For rougher surfaces, a vertical scanning coherence sensing technique can be used to give a nanometer height resolution over several hundred microns of surface height. WLOP allows analyze larger areas than techniques used before in contact lenses, so the values and statistics could be more representative of roughness distribution over the lens surface. Topographic information can be obtained from the surface in aqueous conditions.

2.3. Contact lens surface roughness characteristics

Surface topography and roughness parameters showed different characteristics depending on the type of contact lens (material, water content, manufacture system, replacement frequency). Moreover roughness varies with magnification, so the size of the measured area must be considered when comparing the results of different studies (Kiely and Bonnell, 1997; Kitching et al., 1999). Ra is the arithmetic mean of the departures of the profile from the mean line (Hinojosa Rivera and Reyes Melo, 2001). Thus, it should not vary with magnification for a surface with homogeneously distributed irregularities, regardless of how smooth or rough the surface is. However, the irregularities of most surfaces are not perfectly homogeneously distributed, and effectively differences in contact lens surface roughness values have been observed at different magnifications, with higher roughness scores obtained for larger areas more enlarged areas (Gonzalez-Meijome et al., 2006a). Hence, the amount of variation could reflect how homogeneous a surface is.

Contact lens surface characteristics determined by AFM and by WLOP are presented in the next sections.

2.3.1. CL surface roughness by AFM

Contact lens surfaces roughness and topography can be determined by AFM (Veeco, multimode-nanoscope V) in tapping mode™. (Giraldez et al., 2010c) Although the method used is the same as for dry conditions, a special cell could be necessary so measurements could be made on the lenses in their original shipping fluid (physiological saline) to keep CL hydrated during microscopy observation. All procedures and examinations must be conducted in the same room kept at 21ºC and approximately 50% relative humidity. Then images have to be processed, for example, using the Vision®32 and Nanoscope v7.20 software packages.

Table 1 and table 2 shows height (Ra and Rms) and shape (Rku and Rsk) parameters of 6 hydrogel CL. The specific characteristics of these CL are provided in Table 3. They were all manufactured by cast-molding and had no surface treatment. Although all the lenses are suitable for daily wear, manufacturers recommend a different replacement frequency (Table 1). Senofilcon A and comfilcon A are silicone-hydrogel contact lenses, while hioxifilcon (Osmo 2®), omafilcon A and ocufilcon B are hydroxyethylmethacrylate (HEMA) copolymers and nefilcon A is a polyvinyl alcohol (PVA). The main monomers of the material used to manufacture Osmo 2 contact lenses are those that comprise hioxifilcon (2-HEMA GMA; GMA, glycerylmethacrylate) plus MA (methacrylic acid).

Contact lens25 µm2196 µm2
Ra (nm)Rq (nm)Ra (nm)Rq (nm)
Hioxifilcon-based4.31 0.595.50 0.585.91 0.657.90 0.89
Omafilcon A1.90 0.392.78 0.454.66 2.056.80 2.74
Nefilcon A11.25 0.3815.41 1.2612.99 0.0518.34 0.25
Ocufilcon B11.01 1.7914.38 2.1311.45 2.5623.11 4.49
Senofilcon A3.33 0.284.06 0.383.76 0.054.70 0.005
Comfilcon A1.56 0.372.34 0.692.76 0.804.21 0.44

Table 1.

Mean roughness parameters recorded for the hydrogel contact lenses using AFM on surface areas of 25 µm2 and 196 µm2

Hioxifilcon-basedOmafilcon ANefilcon AOculfincon BSenofilcon AComfilcon A
Rku3.71 0.9423.54 14.815.86 2.035.45 1.953.74 1.6331.09 0.95
Rsk-0.22 0.172.04 1.071.43 0.320.98 0.170.74 0.412.93 0.82

Table 2.

Mean Rku and Rsk values recorded for the hydrogel contact lenses using AFM on a 25 µm2 surface area

Brand nameMaterial
Generic name
ChargeWater content (%)Type of hydrogelReplacement Frequency*
Osmo 2Hioxifilcon-basedNon ionic72HEMA copolymerThree months
ProclearOmafilcon ANon ionic62HEMA copolymerOne month
Focus DailiesNefilcon ANon ionic69PolyvinylalcoholOne day
Frequency 1 dayOcufilcon BIonic52HEMA copolymerOne day
Acuvue OasysSenofilcon ANon ionic38Silicone hydrogelTwo weeks
BiofinityComfilcon ANon ionic48Silicone hydrogelOne month

Table 3.

Specifications of the contact lenses analyzed by AFM.

The corresponding 3-D image of the lenses with the lowest (comfilcon A and omafilcon A) and highest (nefilcon A and ocufilcon B) roughness scores are shown in figure 2. Figure 3 and 4 show the corresponding image for senofilcon A and hioxifilcon CL respectively.

A different surface roughness in a new lens can be the result of the manufacturing method and the material’s properties. The spin casting method generates contact lenses with the smoothest surfaces, followed by cast-molding and then lathe-cut lenses (Guryca et al., 2007; Grobe, 1996). All the lenses presented here were cast-molded, and their roughness parameters were similar to the ranges reported for other non surface-treated cast-molded lenses (Guryca et al., 2007). Thus, the roughness differences between lenses cannot be attributed only to the manufacturing procedure. Besides the mode of elaboration, other authors have linked the presence of methacrylic acid (MA) (Baguet et al., 1993) or a reduced water content (Guryca et al., 2007; Vermeltfoort et al., 2004) to a greater lens surface roughness.

Daily replacement hydrophilic contact lenses (nefilcon A and ocufilcon B), showed the highest roughness values for both surface areas analyzed. In contrast, comfilcon A showed the smoothest, or flattest surface (Ra = 1.56 nm), followed closely by omafilcon A (Ra = 1.90 nm). Similar roughness values were observed for the hioxifilcon-based material and senofilcon A, yet their surface appearance was different (figures 3 and 4). Although the hioxifilcon-based contact lens contains MA, which should determine a greater surface roughness, its similar Ra to senofilcon A could be attributed to its high water content. As may be observed in Figure 3, senofilcon A shows a granulated surface structure, which is similar to that previously reported for the AFM observation of senofilcon A (Teichroeb et al., 2008), of galyficon A (Lira et al., 2008) and for the cryogenic SEM visualization of the latter. (Gonzalez-Meijome et al., 2006b) Galyfilcon A is a non surface-treated silicone hydrogel contact lens that contains PVP as an internal wetting agent.

Figure 2.

Three-dimensional images generated by the AFM analysis of a 25 µm2 area of nefilcon A (a), ocufilcon B (b), comfilcon A (c) and omafilcon A (d).

Figure 3.

Three-dimensional image generated by the AFM analysis of senofilcon A over a 25 µm2 area.

Figure 4.

Three-dimensional image generated by the AFM analysis of hioxifilcon over a 25 µm2 area..

Silicone-hydrogel contact lenses exhibit different surface characteristics depending on their chemical composition and surface treatments (Nicolson PC, 2003). Surface treatments are targeted at obtaining wettable surfaces (Jones L and Dumbleton K, 2002), although the surfaces of the silicone-hydrogel contact lenses presented here were untreated. Thus, senofilcon A incorporates an internal wetting agent (polyvinyl pyrrolidone) that apparently leaches to the lens surface, and the AquaformTM technology used in comfilcon A minimizes lens dehydration by forming hydrogen bonds with water molecules, creating a naturally hydrophilic contact lens that retains water inside the lens (Szczotka-Flynn L, 2007; Whittaker G, 2008). The roughness parameters obtained for these lenses were similar to those observed previously in silicone-hydrogel contact lenses lacking surface treatment, such as galyfilcon A and comfilcon A (Lira et al., 2008; Gonzalez-Meijome et al., 2009), but lower than those reported for surface-treated designs (Gonzalez-Meijome et al., 2006a; Guryca et al., 2007). Despite the similar surface appearance of silicone hydrogels included here and those examined by others, (Teichroeb et al., 2008; Gonzalez-Meijome et al., 2009) Teichroeb et al. observed higher roughness parameters for senofilcon A than Comfilcon A when measuring a 25 µm2 area. These differences could be related to the fact that the lenses were analysed after drying in ambient conditions for 15 minutes.

2.3.2. CL surface roughness by WLOP

The issue of measurement area is an important point to be considered in all surface roughness measurements (Bennett, 1992; Blunt, 2006; Hinojosa and Reyes, 2001; kiely and Bonnell, 1997; Kitching et al., 1999). WLOP allows analysing larger areas than other techniques used before in CL. In this regard, the maximum Hydrogel CL area studied by AFM was 400 µm2 (Gonzalez-Meijome et al., 2006a), which means that for a 14.00 mm diameter CL, only about 2.6x10-4 % of the entire CL surface area would be analyzed. When using WLOP we were able to determine roughness parameters in areas as large as 67646µm2, which is almost 170 higher than the greatest area evaluated by AFM, so values and statistics are suppose to be more representative of the total CL surface (Giraldez et al., 2010a).

WLOP measurements can be obtained with the interference microscopy Wyko-NT1100, a tool that combines a microscopy and an interferometer into the same instrument and which was previously used for hydrogel CL surface analysis. (Giraldez et al., 2010a)

Table 4, 5 and 6 shows values for Ra, Rms and Rmax parameters of 4 hydrogel CL obtained from WLOP analysis for 625 µm2, 2500 µm2, 10829 µm2 and 67646 µm2 areas. The specific characteristics of these CL are provided in Table 7. All these CL were manufactured by cast-moulding and had no surface treatment. Although all lenses are indicated for daily wear, different replacement frequency is recommended by manufacturer (table 1). According with material, hioxifilcon, omafilcon A and ocufilcon B are hydroxyethylmethacrylate (HEMA) copolymers and nefilcon A is a polyvinylalcohol (PVA). Osmo 2 contact lens material is based in hioxifilcon, as their main monomers are those from hioxifilcon (2-HEMA GMA; GMA, glycerylmethacrylate) and MA (methacrylic acid). Lenses were obtained in the original containers filled with a physiological saline solution. As an example, surface appearance of hydrogel contact lenses at different magnification is shown in figure 5.

625 µm22500 µm210829 µm267646 µm2
Hioxifilcon-based31,04 1,7532,88 2,1842,26 7,9247,89 3,97
Omafilcon A17,62 2,5022,18 0,5549,84 9,8367,12 12,59
Ocufilcon B31,11 3.0335,68 2,5030,70 4,50173,11 95,55
Nefilcon A25,04 5.0454,73 17,31114,93 7,29323,77 16,11

Table 4.

Average Roughness (Ra) of hydrogel contact lenses determined by WLOP for 625 µm2, 2500 µm2, 10829 µm2 and 67646 µm2 areas. Mean and Standard Deviation are shown. Values are in nanometers (nm).

625 µm22500 µm210829 µm267646 µm2
Hioxifilcon-based40,07 2,2444,94 4,2561,54 13,3263,25 4,22
Omafilcon A22,41 3,2228,20 0,8865,99 16,0889,37 17,87
Ocufilcon B46,04 3,7452,92 2,2853,07 5,80307,61 178,88
Nefilcon A39,08 12,7197,89 30,97175,03 5,40508,47 49,04

Table 5.

Root-Mean-Square (Rms) of hydrogel contact lenses determined by WLOP for 625 µm2, 2500 µm2, 10829 µm2 and 67646 µm2 areas. Mean and Standard Deviation are shown. Values are in nanometers (nm).

625 µm22500 µm210829 µm267646 µm2
Hioxifilcon-based433,98 27,40869,04 117,331996,67 426,182306,67 1259,61
Omafilcon A280,67 59,22353,57 35,631303,86 528,492646,67 2019,53
Ocufilcon B583,65 103,34854,75 43,991401,80 352,8418196,67 10208,47
Nefilcon A620,39 94,481800,00 612,202723,33 583,1222970,00 4690,00

Table 6.

Maximum Roughness (Rmax) of hydrogel contact lenses determined by WLOP for 625 µm2, 2500 µm2, 10829 µm2 and 67646 µm2 areas. Mean and Standard Deviation are shown. Values are in nanometers (nm).

BrandManufacturerMaterial (USAN)ChargeWater content (%)Principal monomersReplacement Frequency*
Osmo 2MarkEnnovyHioxifilcon-basedNon ionic722-HEMA GMA MAThree months
ProclearCooper VisionOmafilcon ANon ionic62HEMA, PCOne month
Frequency 1 dayCooper VisionOcufilcon BIonic522-HEMA EGDMAOne day
Focus Dailies+Ciba VisionNefilcon ANon ionic69PVP NAAADAOne day

Table 7.

Specifications of the contact lenses analyzed by WLOP.

Figure 5.

Surface topography of hioxifilcon and omafilcon A contact lenses (surface area: 625 µm2) obtained by WLOP.

According with the 625 µm2 and 2500 µm2 area, ocufilcon B and hioxifilcon based CL showed statistical rougher surface scores than those obtainded by omafilcon A, although differences between lenses were not large enough to be clinically relevant. However, when higher areas were considered, it could be observed that daily CL showed an important increase in their roughness values, which is not observed in hioxifilcon based and Omafilcon A lenses (Figures 6 and 7). According to this, analyzing higher areas could assist to detect differences between lenses surface characteristics, which may be not so obvious if smaller areas are studied.

Figure 6.

Variation of Ra (a) and Rms (b) parameters for different scanning surface areas. Y-values represent nanometers (nm). X-values represent µm2.

Figure 7.

Variation of Maximum Roughness (Rmax) for different scanning surface areas. Y-values represent nanometers (nm). X-values represent µm2.

As can be observed, roughness analysis varies with the magnification. Ra is the arithmetic mean of the departures of the profile from the mean line. So, when a surface presents irregularities homogeneously distributed, Ra should not vary with magnification, irrespective of its roughness degree. However, this is not the usual situation, as most of surfaces are not perfectly homogeneous in their irregularities distribution. In fact, there has been reported differences in CL surface roughness values at different magnifications using AFM technique, showing higher roughness scores in higher areas (Gonzalez-Meijome et al., 2006a; Giraldez et al., 2010c). Degree of variation of roughness parameters when increasing size of the measured area could be representative of how homogeneous a surface is. From the data presented here, hioxifilcon based CL has the most homogeneous surface, showing the lower Ra and Rms variation when comparing values from different areas (Figure 6 and 7). Conversely, Nefilcon A showed the highest increase in roughness, displaying the less homogeneous surface of the study.

Local imperfections or sample contamination could affect Ra, Rms and Rmax values. However, their effect on Ra and Rms is supposed to be lower than that on Rmax, since Ra and Rms are average values that should be less affected by local imperfections when higher areas are considered. On the other hand, Rmax might show higher values than expected when imperfections are present, as it indicate maximum peak to valley distance in a measured area, independently of its size. When comparing CL presented here, Rmax variation with area size had a similar pattern than that observed in Ra and Rms for all CL. This can be easily observed when comparing figures 6 and 7. This finding could indicate that the higher Rmax values observed in larger areas, especially in daily CL, would not be due to local imperfections or sample contamination, but rather due to the actual surface roughness of the CL.

Roughness parameters values obtained by WLOP are significantly higher than those previously observed in other hydrogel CL by AFM. This difference between techniques could be related to the effect of the measured area size on the Ra and Rms values, as they tend to be higher when the analyzed area increases (Hinojosa and Reyes, 2001; kiely and Bonnell, 1997; Kitching et al., 1999).

CL surface roughness degree is an important issue as imperfections in the lens surface is where deposits are likely to form (Hosaka et al., 1983). It was also previously demonstrated that the surface roughness increase, the biofilm deposited on the lens increase (Baguet et al., 1995), and that bacterial transfer from a CL is determined by the roughness and hydrophobicity of the surface receiving the bacteria (Vermeltfoort et al., 2004). Daily replacement CL in present study are suppose to acquire more deposits during wear as they had the highest increase in roughness values when higher areas are considered. So, strict replacement regime must be follow in nefilcon A and ocufilcon B CL wear. By gaining a better understanding of the surface roughness of different types of CL, practitioners will be better placed to prescribe the most suitable lens for any given patient and to interpret the clinical performance of lenses they prescribe in relation to patient symptoms and ocular surface signs.

Advertisement

3. Bacterial adhesion to contact lenses

The process of initial adhesion of bacteria to the CL surface has been extensively examined in terms of the physical and chemical properties of both the bacterial cell and CL surface such as hydrophobicity and roughness. Thus, depending on the surface thermodynamics, hydrophilic strains seem to preferentially adhere to hydrophilic surfaces, while more hydrophobic strains have a preference for hydrophobic surfaces. (Bos et al., 1999; Bruinsma et al., 2001)Also, the results of several in vivostudies suggest that a rougher CL surface will be prone to more extensive bacterial adhesion (Bruinsma et al., 2002; Bruinsma et al., 2003) since imperfections in the lens surface is where deposits are likely to form. (Hosaka et al., 1983)

Microbial colonization can be quantified by enumerating colony-forming units (CFU) using different bacterial strains, as the P. aeruginosastrain CECT 110 or S. epidermidisstrain CECT 4184 (both from the Spanish Type Culture Collection).Adhesion can be determined by immersing each CL, convex side up, in 1 ml of a cell suspension of P. aeruginosaor S. epidermidiswhose concentration of 1.2 x 109 CFU/ml (adjusted to McFarland scale No.4) is determined by dilution in sterile saline solution (SS) and spreading on Tryptic Soy Agar (TSA) plates. Following incubation of the bacterial suspension for 2 h at 37ºC with continuous shaking (15 rpm), each CL has to be carefully removed and washed 3 times in sterile SS. Next each lens is placed in 2 ml of sterile SS and sonicated using a Bronson Sonifier 250 for 1 min. The suspensions then spread on TSA-1 plates and CFU enumerated after 24 h of incubation at 37ºC.

3.1. Microbial keratitis on contact lens wear

The adhesion of bacteria to contact lenses (CL), notably that of Pseudomonas aeruginosaand Staphylococcus epidermidis, is considered a primary risk factor of serious corneal problems (Buehler PO et al., 1992; Catalonotti P et al., 2005; Leitch EC et al., 1998). The CL surface is a suitable substrate for bacterial adhesion and biofilm formation, and can sustain the growth of an inoculum of organisms in prolonged contact with the cornea (Elder Mj et al., 1995). In addition, corneal interaction with the CL can override the protective mechanisms of the cornea, augmenting the capacity of microbial cells to adhere to the cornea and progress to microbial keratitis (MK). To improve the corneal/CL interface, several co-polymers have been incorporated into soft hydrogel lens materials, including silicone polymers for increased oxygen permeability and phosphoryl-choline to increase biocompatibility. Further, the new modalities of wear, such as daily disposable (DD) hydrogel CL, avoid the need for regular cleaning and storage, which are known to be an important cause of microbial contamination (Laughlin-Borlace et al., 1998). Notwithstanding, studies have shown that users of DD and silicone hydrogel CL do not show a reduced risk of MK (Dart et al., 2008; Stapleton et al., 2008). In the paper by Dart et al., differences in soft CL design and/or the composing polymer rather than the mode of wear were found to determine susceptibility to MK (Dart et al., 2008).

Several microbial strains have been isolated from clinical samples of MK. Approximately two thirds of these strains are Gram-negative bacterial strains, most notably Pseudomonas aeruginosabut also some Serratiaspecies, while one third comprises Gram-positive cocci, including Staphylococcus aureusand Staphylococcusepidermidis(Catalonotti P et al., 2005; Leitch EC et al., 1998; Seal et al., 1999). S epidermidisis one of the microorganisms most frequently isolated from the normal microbiota of the human eye surface (Ayoub M et al., 1994; Doyle A et al., 1995; Hara J et al., 1997). Despite this, this bacterium has been held responsible for infections such as chronic blepharitis, conjunctivitis and keratitis, especially in immunocompromised hosts (Pinna A et al., 1999), and may account for 45 per cent of all cases of bacterial keratitis (Nayak et al., 2007; Nayak and Satpathy, 2000). In CL wearers, S. epidermidisfinds itself in a privileged position to act as an opportunistic pathogen, colonizing the lens surface from the eye and surrounding areas. The microorganism also shows an adhesion preference for foreign materials and has the capacity to produce an extracellular substance comprised of polysaccharides (slime) (Perilli et al., 2000).

Pseudomonasaeruginosais a common Gram-negative bacillus that acts as an opportunistic pathogen under several circumstances (Lyczak et al., 2000). As a Gram-negative bacterium, the lipopolysaccharides (LPS) composing its outer membrane act as key virulence factor, promoting infection by interfering with the host immune response (Wilkinson, 1983; Cryz, Jr. et al., 1984). Other virulence factors encoded by P. aeruginosacould help bacterial survival on the ocular surface. These factors are those needed for strategies such as biofilm formation, resistance against killing, communication between bacteria (e.g., quorum sensing), invading epithelial cells and surviving within them, destroying tear components, breaking down cell-to cell junctions and extracellular matrices, and injecting toxins into cells (Alarcon et al., 2009; Angus et al., 2008; Evans et al., 2007; Fleiszig et al., 1994; Fleiszig, 2006; Hauser, 2009; Lyczak et al., 2000; Wagner and Iglewski, 2008; Willcox, 2007; Zolfaghar et al., 2003; Zolfaghar et al., 2005; Zolfaghar et al., 2006). Pseudomonas aeruginosaalso possesses factors that are highly immunogenic (initiate inflammation) while being able to evade the immune responses they initiate (Choy et al., 2008; Evans et al., 2007; Hazlett, 2007; Lyczak et al., 2000). Interestingly, P. aeruginosavirulence factors can also confer resistance to contact lens disinfectants (Lakkis and Fleiszig, 2001).

3.2. Effect of hydrophobicity and surface roughness

Bacterial adhesion to a biomaterial is thought to depend on the hydrophobicity of the biomaterial, such that adhesion decreases with the water content of the CL (Ahanotu et al., 2001; Kodjikian et al., 2004; Magnusson, 1982). The effect of surface roughness on bacterial adhesion to a CL is still far from being well understood. According to prior work, it seems clear that surface roughness is related to deposit formation and microorganism colonization of the surface (Baguet et al., 1995; Vermeltfoort et al., 2004). Greater surface roughness determines a greater specific surface area, thus creating more available active sites for thermodynamic reactions. Bacterial adhesion initiates on surface irregularities that serve as microenvironments where bacteria are sheltered from unfavorable environmental factors and then promote their survival (Shellenberger and Logan, 2002; Chae et al., 2006; Jones and Velegol, 2006). The effects of surface roughness have been examined over a wide range of physical scales (Bruinsma et al., 2001; Li and Logan, 2004; Li and Logan, 2005; Emerson et al., 2006; Mitik-Dineva et al., 2008; Park et al., 2008) and previous studies suggest that nanoscale surface roughness may greatly influence bacterial adhesion (Mitik-Dineva et al., 2008).

3.2.1. Staphylococcus epidermidis

Initial adhesion of S. epidermidisto unworn or worn conventional hydrogel CL has been reported to be strain and substrate related, the hydrophilic nature of the lens being a key factor (George et al., 2003; Henriques et al., 2005). The incorporation of silicone in a hydrogel polymer achieves high oxygen permeability but on the other hand reduces hydrophilicity (Tighe B, 2009). According with previous studies (Giraldez et al., 2010b), unworn silicone hydrogel CL (more hydrophobic) show a greater susceptibility to S. epidermidisadhesion than the conventional hydrogel CL (Figure 6). This observation is consistent with the established relationship between microbial adhesion and lens surface hydrophobicity. Notwithstanding, Santos et al. (Santos et al., 2008) were unable to detect any difference in microbial adhesion when comparing unworn silicone hydrogel and conventional hydrogel CL. This discrepancy could be explained by the different extents of microbial colonization observed for different S. epidermidisstrains, and/or the different methodologies employed (Henriques et al., 2005; Kodjikian et al., 2007). In both hydrophobic and hydrophilic groups, the lenses showing the lowest Ra values (omafilcon A and comfilcon A) also returned the lowest numbers of S. epidermidisCFU, despite their high Rku and Rsk values. Roughness values corresponding to these lenses are shown in tables 1 and 2.

Figure 8.

Adhesion ofS. epidermidisCECT 4184 to hydrophilic (a) and hydrophobic (b) hydrogel contact lenses.

3.2.2. Pseudomona aeruginosa

Figure 7 provides the quantities, in CFU, of P. aeruginosathat adhered to six unworn CL (4 silicone hydrogel and 2 conventional hydrogel CL). In these lenses, it can be observed no substantial preference of P. aeruginosato adhere to unworn hydrophilic or hydrophobic CL. Although this is consistent with other studies for other bacterial strains (Borazjani et al., 2004; Santos et al., 2008), it challenges the established relationship between microbial adhesion and lens surface hydrophobicity (Pritchard et al., 1999; Doyle, 2000; Young et al., 2002; van Oss, 2003; Giraldez et al., 2010b). This discrepancy could be explained by the different extents of microbial colonization observed for different bacterial strains, and/or the different methodologies employed (Henriques et al., 2005; Kodjikian et al., 2007). In fact, most P. aeruginosastrains have a more hydrophilic surface than S. epidermidisor other bacteria (Gottenbos et al., 2001; Mitik-Dineva et al., 2009). This could explain the scarce difference observed between P. aeruginosaadhesion to hydrophilic and hydrophobic contact lenses relative to previously observed S. epidermidisadhesion patterns (Bos et al., 1999; Bakker et al., 2002; Giraldez et al., 2010b).

In relation with roughness effect, the lenses showing the highest Ra values accompanied by low Rku and Rsk values (for a 25 µm2 area, ocufilcon B: Ra=11.01 1.79 nm, Rku=5.45 1.95 and Rsk= 0.98 0.17; and lotrafilcon B: Ra=26,97 3,91nm, Rku=4,11 1,28 and Rsk= -0,34 0,07) also returned the lowest numbers of P. aeruginosaCFU. Nanomaterials are those with constituent dimensions smaller than 100 nm in at least one direction and have numerous biomedical applications (Park et al., 2008). Nanophase materials have greater surface areas, more surface defects, increased surface electron delocalization and greater numbers of surface grain boundaries. Since they show a higher percentage of atoms at their surfaces compared to conventional materials, the surface properties of nanophase materials differ and this results in higher surface reactivity to cell responses (Park et al., 2008; Mitik-Dineva et al., 2008). Although changes in metabolic responses have not been clearly defined, research has shown altered attachment rates for certain bacteria on nanophase surfaces, which could translate to enhanced or reduced adhesion (Park et al., 2008; Mitik-Dineva et al., 2008; Mitik-Dineva et al., 2009). Thus, while nanophase materials show reduced Staphylcoccus epidermidiscolonization compared to conventional materials (Colon et al., 2006; Giraldez et al., 2010b) they nevertheless show improved P. aeruginosacolonization (Mitik-Dineva et al., 2009; Webster et al., 2005).

Figure 9.

Adhesion ofP. aeruginosato both hydrophilic (omafilcon A and ocufilcon B) and hydrophobic (senofilcon A, comfilcon A, balafilcon A and lotrafilcon B) contact lenses.

Advertisement

4. Conclusion

Surface hydrophobicity and roughness are critical factors for bacterial adhesion; the surface of any body or object is the part which interacts with the surrounding environment. Hydrophobicity effect on bacterial adhesion to contact lenses is different in depending on bacterial strains; it seems to have a higher influence in S epidermidisthan in P aeruginosaadhesion. Moreover, roughness is a biological factor that affects the manner in which bacteria adhere to surfaces, above all for initial adhesion; so by gaining a better understanding of the surface roughness of different types of CL, practitioners will be better placed to prescribe the most suitable lens for any given patient and to interpret the clinical performance of lenses they prescribe in relation to patient symptoms and ocular surface signs.

References

  1. 1. AhanotuE. N.HyattM. D.GrahamM. J.AhearnD. G.2001Comparative radiolabel and ATP analyses of adhesion of Pseudomonas aeruginosa and Staphylococcus epidermidis to hydrogel lenses.CLAO J278993.
  2. 2. AlarconI.KwanL.YuC.EvansD. J.FleiszigS. M.2009Role of the corneal epithelial basement membrane in ocular defense against Pseudomonas aeruginosa.Infect.Immun.77326471.
  3. 3. AngusA. A.LeeA. A.AugustinD. K.LeeE. J.EvansD. J.FleiszigS. M.2008Pseudomonas aeruginosa induces membrane blebs in epithelial cells, which are utilized as a niche for intracellular replication and motility. Infect.Immun.7619922001.
  4. 4. AyoubM.BadrA.ElianS.1994A study of the effect of antibiotics on the normal flora of the eye. Med J Cairo Univ621218.
  5. 5. BaguetJ.SommerF.Claudon-EylV.DucT. M.1995Characterization of lacrymal component accumulation on worn soft contact lens surfaces by atomic force microscopy.Biomaterials1639.
  6. 6. BaguetJ.SommerF.DucT. M.1993Imaging surfaces of hydrophilic contact lenses with the atomic force microscope.Biomaterials1427984.
  7. 7. BakkerD. P.BusscherH.and van der Mei, H. C.2002Bacterial deposition in a parallel plate and a stagnation point flow chamber: microbial adhesion mechanisms depend on the mass transport conditions.Microbiology148597603.
  8. 8. BennettJ. M.1992Recent developments in surface roughenss characterization. Meas Sci Technol3111927.
  9. 9. BhatiaS.GoldbergE. P.EnnsJ. B.1997Examination of contact lens surfaces by Atomic Force Microscope (AFM).CLAO J.232649.
  10. 10. BluntR. T.2006White light interferometry- a production worthy technique for measuring surface roughness on semiconductor wafers. CS Mantched Conference. Proceedings of the CS Mantched Conferences.
  11. 11. Bohnert JL, Horbett TA, Ratner BD and Royce FH.1988Adsorption of proteins form artificial tear solutions to contact lens materials. Ophthalmol Vis Sci2936273.
  12. 12. BorazjaniR. N.LevyB.AhearnD. G.2004Relative primary adhesion of Pseudomonas aeruginosa, Serratia marcescens and Staphylococcus aureus to HEMA-type contact lenses and an extended wear silicone hydrogel contact lens of high oxygen permeability. Cont Lens Anterior Eye2738.
  13. 13. BosR.van der MeiH. C.BusscherH. J.1999Physico-chemistry of initial microbial adhesive interactions--its mechanisms and methods for study.FEMS Microbiol Rev23179230.
  14. 14. BruinsmaG. M.Rustema-AbbingM.de VriesJ.BusscherH. J.van der LindenM. L.HooymansJ.and van der Mei, H. C.2003Multiple surface properties of worn RGP lenses and adhesion of Pseudomonas aeruginosa. Biomaterials24166370.
  15. 15. BruinsmaG. M.Rustema-AbbingM.deV. J.StegengaB.van der MeiH. C.van der LindenM. L.HooymansJ. M.BusscherH. J.2002Influence of wear and overwear on surface properties of etafilcon A contact lenses and adhesion of Pseudomonas aeruginosa. Invest Ophthalmol.Vis.Sci.43364653.
  16. 16. BruinsmaG. M.Rustema-AbbingM.van der MeiH. C.BusscherH. J.2001Effects of cell surface damage on surface properties and adhesion of Pseudomonas aeruginosa.J.Microbiol.Methods4595101.
  17. 17. BuehlerP. O.ScheinO. D.StamlerJ. F.VerierD. D.KarzJ.1992The increased risk of ulcerative keratitis among disposable soft contact lens users.Arch Ophthalmol11015558.
  18. 18. CaberP.1993Interferometric profiler for rough surfaces.Appl Opt32343841.
  19. 19. CarneyF. P.NashW. L.SentellK. B.2008The Adsorption of Major Tear Film Lipids In Vitro to Various Silicone Hydrogels over Time. Invest Ophthalmol.Vis.Sci.491204.
  20. 20. CatalonottiP.LanzaM.Del PreteA.LucidoM.CataniaM. R.CalleF.BoggiaD.PerfettoB.RossanoF.2005Slime-producing Staphylococcus epidermidis and S. aureus in acute bacterial conjunctivitis in soft contact lens wearers. New Microbiol2834554.
  21. 21. CehreliZ. C.LakshmipathyM.YaziciR.2008Effect of different splint removal techniques on the surface roughness of human enamel: a three-dimensional optical profilometry analysis.Dental Traumatology2417782.
  22. 22. ChaeM. S.SchraftH.TruelstrupH. L.MackerethR.2006Effects of physicochemical surface characteristics of Listeria monocytogenes strains on attachment to glass. Food Microbiol.232509.
  23. 23. ChengK. H.LeungS. L.HoekmanH. W.BeekhuisW. H.MulderP. G.GeerardsA. J.KijlstraA.1999Incidence of contact-lens-associated microbial keratitis and its related morbidity. Lancet3541815.
  24. 24. ChoyM. H.StapletonF.WillcoxM. D.ZhuH.2008Comparison of virulence factors in Pseudomonas aeruginosa strains isolated from contact lens- and non-contact lens-related keratitis.J.Med.Microbiol.57153946.
  25. 25. ColonG.WardB. C.WebsterT. J.2006Increased osteoblast and decreased Staphylococcus epidermidis functions on nanophase ZnO and TiO2.J.Biomed.Mater.Res.A78595604.
  26. 26. CryzS. J.JrPittT. L.FurerE.GermanierR.1984Role of lipopolysaccharide in virulence of Pseudomonas aeruginosa. Infect.Immun.4450813.
  27. 27. DartJ. K.RadfordC. F.MinassianD.VermaS.StapletonF.2008Risk factors for microbial keratitis with contemporary contact lenses: a case-control study.Ophthalmology115164754.
  28. 28. DonlanR. M.2002Biofilms: microbial life on surfaces. Emerg.Infect.Dis.888190.
  29. 29. Donshik PC.2003Contact lens chemistry and giant papillary conjunctivitis.Eye Contact Lens 29, S37-S39.
  30. 30. DoyleA.BelgiB.EarlyA.BlakeA.EustaceP.HoneR.1995Adherence of bacteria to intraocular lenses: a propective study. Br J Ophthalmol793479.
  31. 31. DoyleR. J.2000Contribution of the hydrophobic effect to microbial infection.Microbes.Infect.2391400.
  32. 32. MjElderStapleton. F.EvansE.DartJ. K.1995Biofilm-related infections in ophthalomology. Eye91029.
  33. 33. EmersonR. J.BergstromT. S.LiuY.SotoE. R.BrownC. A.Mc GimpseyW. G.CamesanoT. A.2006Microscale correlation between surface chemistry, texture, and the adhesive strength of Staphylococcus epidermidis. Langmuir221131121.
  34. 34. EvansD. J.Mc NamaraN. A.FleiszigS. M.2007Life at the front: dissecting bacterial-host interactions atthe ocular surface.Ocul.Surf.521327.
  35. 35. FleiszigS. M.2006The Glenn A. Fry award lecture 2005. The pathogenesis of contact lens-related keratitis.Optom.Vis.Sci.8386673.
  36. 36. FleiszigS. M.ZaidiT. S.FletcherE. L.PrestonM. J.PierG. B.1994Pseudomonas aeruginosa invades corneal epithelial cells during experimental infection. Infect.Immun.62348593.
  37. 37. FletcherE. L.FleiszigS. M.BrennanN. A.1993aLipopolysaccharide in adherence of Pseudomonas aeruginosa to the cornea and contact lenses.Invest Ophthalmol Vis Sci3419306.
  38. 38. FletcherE. L.WeissmanB. A.EfronN.FleiszigS. M.CurcioA. J.BrennanN. A.1993bThe role of pili in the attachment of Pseudomonas aeruginosa to unworn hydrogel contact lenses.Curr.Eye Res.12106771.
  39. 39. GadelmawlaE. S.KouraM. M.MaksoudT. M. A.ElewaI. M.SolimanH. H.2002Roughness parameters. Journal of Materials Processing Technology12313345.
  40. 40. GarrettQ.GarrettR. W.MilthorpeB. K.1999Lysozime sorption in hydrogel contact lenses. Invest Ophthalmol.Vis.Sci.40897903.
  41. 41. GarrettQ.LaycockB.GarrettR. W.2000Hydrogel lens monover constituents modulate protein sorption. Invest Ophthalmol.Vis.Sci.41167895.
  42. 42. GeorgeM.AhearnD.PierceG.GabrielM.2003Interactions of Pseudomonas aeruginosa and Staphylococcus epidermidis in adhesion to a hydrogel.Eye Contact Lens 29, S105-S109.
  43. 43. GiraldezM. J.Garcia-ResuaC.LiraM.RealOliveira. M. E.Yebra-PimentelE.2010aWhite light interferometry to characterize the hydrogel contact lens surface. Ophthalmic Physiol Opt.3028997.
  44. 44. GiraldezM. J.ResuaC. G.LiraM.OliveiraM. E.MagarinosB.ToranzoA. E.Yebra-PimentelE.2010bContact lens hydrophobicity and roughness effects on bacterial adhesion. Optom.Vis.Sci. 87, E426-E431.
  45. 45. GiraldezM. J.SerraC.LiraM.RealOliveira. M. E.Yebra-PimentelE.2010cSoft contact lens surface profile by atomic force microscopy. Optom.Vis.Sci. 87, E475-E481.
  46. 46. Gonzalez-MeijomeJ. M.Lopez-AlemanyA.AlmeidaJ. B.ParafitaM. A.2009Surface AFM microscopy of unworn and worn samples of silicone hydrogel contact lenses. J Biomed Mater Res.B Appl Biomater.887582.
  47. 47. Gonzalez-MeijomeJ. M.Lopez-AlemanyA.AlmeidaJ. B.ParafitaM. A.RefojoM. F.2006aMicroscopic observation of unworn siloxane-hydrogel soft contact lenses by atomic force microscopy.J.Biomed.Mater.Res.B Appl.Biomater.764128.
  48. 48. Gonzalez-MeijomeJ. M.Lopez-AlemanyA.AlmeidaJ. B.ParafitaM. A.RefojoM. F.2006bMicroscopic observations of superficial ultrastructure of unworn siloxane-hydrogel contact lenses by cryo-scanning electron microscopy.J.Biomed.Mater.Res.B Appl.Biomater.7641923.
  49. 49. GottenbosB.GrijpmaD. W.van der MeiH. C.FeijenJ.BusscherH. J.2001Antimicrobial effects of positively charged surfaces on adhering Gram-positive and Gram-negative bacteria. J.Antimicrob.Chemother.48713.
  50. 50. GrobeG.1996Surface chemical structure for soft contact lenses as a funciton of polymer processing. J.Biomed.Mater.Res.324554.
  51. 51. GuillonM.MaissaC.2007Use of silicone hydrogel material for daily wear. Cont.Lens Anterior.Eye30510.
  52. 52. GuptaS. K.BerkR. S.MasinickS.HazlettL. D.1994Pili and lipopolysaccharide of Pseudomonas aeruginosa bind to the glycolipid asialo GM1.Infect.Immun.6245729.
  53. 53. GuptaS. K.MasinickS. A.HobdenJ. A.BerkR. S.HazlettL. D.1996Bacterial proteases and adherence of Pseudomonas aeruginosa to mouse cornea. Exp Eye Res.6264150.
  54. 54. GurycaV.HobzovaR.PradnyM.SircJ.MichalekJ.2007Surface morphology of contact lenses probed with microscopy techniques. Cont.Lens Anterior.Eye3021522.
  55. 55. HanssonS.2000Surface roughness parameters as predictors of anchorage strength in bone: a critical analysis.J Biomech.331297303.
  56. 56. HaraJ.YasudaF.HigashitsutsumiM.1997Preoperative desinfection of the conjunctival sac in cataract surgery. Ophthalmologica211627.
  57. 57. HauserA. R.2009The type III secretion system of Pseudomonas aeruginosa: infection by injection. Nat.Rev.Microbiol.765465.
  58. 58. HazlettL. D.2007Bacterial infections of the cornea (Pseudomonas aeruginosa).Chem.Immunol.Allergy9218594.
  59. 59. HenriquesM.SousaC.LiraM.ElisabeteM.OliveiraR.OliveiraR.AzeredoJ.2005Adhesion of Pseudomonas aeruginosa and Staphylococcus epidermidis to silicone-hydrogel contact lenses.Optom Vis Sci8244650.
  60. 60. HinojosaRivera. M.ReyesMelo.ME2001La rugosidad de las superficies: topometría. Ingenierias42733.
  61. 61. HoldenB. A.SankaridurgP. R.SweeneyD. F.StrettonS.NaduvilathT. J.RaoG. N.2005Microbial keratitis in prospective studies of extended wear with disposable hydrogel contact lenses. Cornea2415661.
  62. 62. HootonJ. C.GermanC. S.AllenS.DaviesM. C.RobertsC. J.TendlerS. J.WilliamsP. M.2004An atomic force microscopy study of the effect of nanoscale contact geometry and surface chemistry on the adhesion of pharmaceutical particles. Pharm.Res.2195361.
  63. 63. HootonJ. C.GermanC. S.DaviesM. C.RobertsC. J.2006A comparison of morphology and surface energy characteristics of sulfathiazole polymorphs based upon single particle studies. Eur.J Pharm.Sci2831524.
  64. 64. HosakaS.OzawaH.TanzawaH.IshidaH.YoshimuraK.MomoseT.MagataniH.NakajimaA.1983Analysis of deposits on high water content contact lenses. J.Biomed.Mater.Res.1726174.
  65. 65. JonesL.DumbletonK.2002Silicone hydrgels contact lenses, Part 1. Evolution and current status. Optometry Today202632.
  66. 66. JonesL.SenchynaM.MAGlasierSchickler. J.ForbeI.LouieD.MayC.2003Lysozyme and lipid deposition on silicone hydrogel contact lens materials.Eye Contact Lens 29, S75-S79.
  67. 67. JonesJ. F.VelegolD.2006Laser trap studies of end-on E. coli adhesion to glass. Colloids Surf.B Biointerfaces.506671.
  68. 68. KeayL.EdwardsK.StapletonF.2009Signs, symptoms, and comorbidities in contact lens-related microbial keratitis. Optom.Vis.Sci.868039.
  69. 69. Kiely JD and Bonnell DA.1997Quantification of topographic structure by scanning probe microscopy. J Vac Sci Technol B15148393.
  70. 70. KimS. H.OpdahlA.MarmoC.SomorjaiG. A.2002AFM and SFG studies of pHEMA-based hydrogel contact lens surfaces in saline solution: adhesion, friction, and the presence of non-crosslinked polymer chains at the surface.Biomaterials23165766.
  71. 71. KitchingS.WilliamsP. M.RobertsC. J.DaviesM. C.TendlerS. J. B.1999Quantifying surface topography and scannig probe image reconstruction. J Vac Sci Technol B172739.
  72. 72. KodjikianL.BurillonC.RoquesC.PellonG.RenaudF. N.HartmannD.FreneyJ.2004Intraocular lenses, bacterial adhesion and endophthalmitis prevention: a review. Biomed Mater Eng14395409.
  73. 73. KodjikianL.Casoli-BergeronE.MaletF.Janin-ManificatH.FreneyJ.BurillonC.ColinJ.SteghensJ. P.2007Bacterial adhesion to conventional hydrogel and new silicone-hydrogel contact lens materials. Graefes Arch.Clin.Exp.Ophthalmol.
  74. 74. KogureK.IkemotoE.MorisakiH.1998Attachment of Vibrio alginolyticus to glass surfaces is dependent on swimming speed. J Bacteriol.1809327.
  75. 75. LakkisC.FleiszigS. M.2001Resistance of Pseudomonas aeruginosa isolates to hydrogel contact lens disinfection correlates with cytotoxic activity.J Clin Microbiol.39147786.
  76. 76. Laughlin-BorlaceL.StapletonF.MathesonM.DartJ. K.1998Bacterial biofilm on contact lenses and lens storage cases in wearers with microbial keratitis.J Appl Microbiol8482738.
  77. 77. LeeS. P.LeeS. J.LimB. S.AhnS. J.2009Surface characteristics of orthodontic materials and their effects on adhesion of mutans streptococci. Angle Orthod.7935360.
  78. 78. Leitch EC, Harmis NY, Corrigan KM and Willcox MD.1998Identification and enumeration of staphylococci form the eye during soft contact lens wear. Optom Vis Sci7525865.
  79. 79. LiB.LoganB. E.2004Bacterial adhesion to glass and metal-oxide surfaces. Colloids Surf.B Biointerfaces.368190.
  80. 80. LiB.LoganB. E.2005The impact of ultraviolet light on bacterial adhesion to glass and metal oxide-coated surface. Colloids Surf.B Biointerfaces.4115361.
  81. 81. LiesegangT. J.2002Physiologic changes of the cornea with contact lens wear.CLAO J.281227.
  82. 82. LindeY. W.BengtssonA.LodenM.1989Dry’ skin in atopic dermatitis. II. A surface profilometry study. Acta Derm.Venereol.693159.
  83. 83. LinneweberJ.DohmenP. M.KertzscherU.AffeldK.NoseY.KonertzW.2007The effect of surface roughness on activation of the coagulation system and platelet adhesion in rotary blood pumps. Artif.Organs3134551.
  84. 84. LiraM.SantosL.AzeredoJ.Yebra-PimentelE.OliveiraM. E.2008Comparative study of silicone-hydrogel contact lenses surfaces before and after wear using atomic force microscopy. J.Biomed.Mater.Res.B Appl.Biomater.853617.
  85. 85. LorentzH.RogersR.JonesL.2007The impact of lipid on contact angle wettability.Optom.Vis.Sci.8494653.
  86. 86. LyczakJ. B.CannonC. L.PierG. B.2000Establishment of Pseudomonas aeruginosa infection: lessons from a versatile opportunist.Microbes.Infect.2105160.
  87. 87. MackD.HaederM.SiemssenN.LaufsR.1996Association of biofilm production of coagulase-negative staphylococci with expression of a specific polysaccharide intercellular adhesin.J Infect.Dis.1748814.
  88. 88. MackD.NedelmannM.KrokotschA.SchwarzkopfA.HeesemannJ.LaufsR.1994Characterization of transposon mutants of biofilm-producing Staphylococcus epidermidis impaired in the accumulative phase of biofilm production: genetic identification of a hexosamine-containing polysaccharide intercellular adhesin.Infect.Immun.62324453.
  89. 89. MackD.RiedewaldJ.RohdeH.MagnusT.FeuchtH. H.ElsnerH. A.LaufsR.RuppM. E.1999Essential functional role of the polysaccharide intercellular adhesin of Staphylococcus epidermidis in hemagglutination. Infect.Immun.6710048.
  90. 90. MagnussonK. E.1982Hydrophobic interaction--a mechanism of bacterial binding.Scand.J Infect.Dis.Suppl33326.
  91. 91. Mah-SadorraJ. H.YavuzS. G.NajjarD. M.LaibsonP. R.RapuanoC. J.CohenE. J.2005Trends in contact lens-related corneal ulcers. Cornea24518.
  92. 92. Maldonado-CodinaC.EfronN.2005Impact of manufacturing technology and material composition on the surface characteristics of hydrogel contact lenses.Clin Exp Optom88396404.
  93. 93. Mitik-DinevaN.WangJ.MocanasuR. C.StoddartP. R.CrawfordR. J.IvanovaE. P.2008Impact of nano-topography on bacterial attachment. Biotechnol.J.353644.
  94. 94. Mitik-DinevaN.WangJ.TruongV. K.StoddartP.MalherbeF.CrawfordR. J.IvanovaE. P.2009Escherichia coli, Pseudomonas aeruginosa, and Staphylococcus aureus Attachment Patterns on Glass Surfaces with Nanoscale Roughness. Current Microbiology5826873.
  95. 95. MorisakiH.NagaiS.OhshimaH.IkemotoE.KogureK.1999The effect of motility and cell-surface polymers on bacterial attachment.Microbiology 145 ( Pt 10),2797 EOF802 EOF.
  96. 96. NayakN.NagT. C.SatpathyG.RayS. B.2007Ultrastructural analysis of slime positive & slime negative Staphylococcus epidermidis isolates in infectious keratitis.Indian J Med Res.12576771.
  97. 97. NayakN.SatpathyG.2000Slime production as a virulence factor in Staphylococcus epidermidis isolated from bacterial keratitis.Indian J Med Res.111610.
  98. 98. Nicolson PC.2003Continuous wear contact lens surface chemistry and wearability.Eye Contact Lens 29, S30-S32.
  99. 99. NovakE.PasopF.BrowneT.2003Production metrology for MEMS characterization. Proceedings of the 2003 Desing, Test, Integration & Packaging of MEMS/MOEMS. Cannes-Mandelieu
  100. 100. O’MahonyC.HillM.BrunetM.DuaneR.MathewsonA.2003Characterization fo micromechanical structures using white-light interferometry. Meas Sci Technol14180714.
  101. 101. OlefjordI.HanssonS.1993Surface analysis of four dental implant systems. Int J Oral Maxillofac.Implants.83240.
  102. 102. ParkM. R.BanksM. K.ApplegateB.WebsterT. J.2008Influence of nanophase titania topography on bacterial attachment and metabolism. Int.J.Nanomedicine.3497504.
  103. 103. PatelA.HammersmithK.2008Contact lens-related microbial keratitis: recent outbreaks. Curr.Opin.Ophthalmol193026.
  104. 104. PerilliR.MarzianoM. L.FormisanoG.CaiazzaS.ScorciaG.BaldassarriL.2000Alteration of organized structure of biofilm formed by Staphylococcus epidermidis on soft contact lenses.J Biomed Mater Res.49537.
  105. 105. PinnaA.ZabettuS.SotgiuM.SechiL. A.FaddaG.CartaF.1999Identification and antibiotic susceptibility of coagulase negative staphylococi isolated in corneal /external infections. Br J Ophthalmol837713.
  106. 106. PritchardN.FonnD.BrazeauD.1999Discontinuation of contact lens wear: a survey. Int Contact Lens Clin2615762.
  107. 107. RaulioM.JarnM.AholaJ.PeltonenJ.RosenholmJ. B.TervakangasS.KolehmainenJ.RuokolainenT.NarkoP.Salkinoja-SalonenM.2008Microbe repelling coated stainless steel analysed by field emission scanning electron microscopy and physicochemical methods. J Ind.Microbiol Biotechnol3575160.
  108. 108. RebeixV.SommerF.MarchinB.BaudeD.TranM. D.2000Artificial tear adsorption on soft contact lenses: methods to test surfactant efficacy.Biomaterials211197205.
  109. 109. RileyC.YoungG.ChalmersR.2006Prevalence of ocular surface symptoms, signs, and uncomfortable hours of wear in contact lens wearers: the effect of refitting with daily-wear silicone hydrogel lenses (senofilcon a).Eye Contact Lens322816.
  110. 110. SantosL.RodriguesD.LiraM.RealOliveira. M. E.OliveiraR.VilarE. Y.AzeredoJ.2008Bacterial adhesion to worn silicone hydrogel contact lenses. Optom Vis Sci855205.
  111. 111. SealD. V.KirknessC. M.BennettH. G.PetersonM.1999Population-based cohort study of microbial keratitis in Scotland: incidence and features. Cont.Lens Anterior.Eye224957.
  112. 112. SerpD.MuellerM.VonStockar. U.MarisonI. W.2002Low-temperature electron microscopy for the study of polysaccharide ultraestructures in hydrogels.I. Theoretical and technical considerations. Biotechnol Bioeng7924352.
  113. 113. SheenS.BaoG.CookeP.2008Food surface texture measurement using reflective confocal laser scanning microscopy. J Food Sci 73, E227-E234.
  114. 114. ShellenbergerK.LoganB. E.2002Effect of molecular scale roughness of glass beads on colloidal and bacterial deposition.Environ.Sci Technol361849.
  115. 115. SkotnitskyC.NaduvilathT. J.SweeneyD. F.SankaridurgP. R.2006Two presentations of contact lens-induced papillary conjunctivitis (CLPC) in hydrogel lens wear: local and general.Optom Vis Sci832736.
  116. 116. SkotnitskyC.SankaridurgP. R.SweeneyD. F.BAHolden2002General and local contact lens induced papillary conjunctivitis (CLPC).Clin Exp Optom851937.
  117. 117. CESoltys-RobitailleAmmon. D. M.jr ValintP. L.jrGrobeG.2001The relationship between contact lens surface charge and in-vitro protein deposition levels.Biomaterials22325760.
  118. 118. StapletonF.KeayL.EdwardsK.NaduvilathT.DartJ. K.FranzcoG. B.HoldenB.2008The Incidence of Contact Lens-Related Microbial Keratitis in Australia. Ophthalmology
  119. 119. SubbaramanL. N.BayerS.GeprS.MAGlasierLorentz. H.SenchynaM.JonesL.2006Rewetting drops containing surface active agents improve the clinical performance of silicone hydrogel contact lenses.Optom Vis Sci8314351.
  120. 120. Szczotka-FlynnL.2007Lens distinctions.http://www.clspectrum.com/
  121. 121. Szmukler-MonclerS.TestoriT.BernardJ. P.2004Etched implants: a comparative surface analysis of four implant systems.J Biomed Mater Res.B Appl Biomater.694657.
  122. 122. TeichroebJ. H.ForrestJ. A.NgaiV.MartinJ. W.JonesL.MedleyJ.2008Imaging protein deposits on contact lens materials. Optom Vis Sci85115164.
  123. 123. TigheB.2009Silicone hydrogels: what are they and how should they be used in everyday practice? Optician218312.
  124. 124. van OssC. J.2003Long-range and short-range mechanisms of hydrophobic attraction and hydrophilic repulsion in specific and aspecific interactions.J Mol.Recognit.1617790.
  125. 125. VermeltfoortP. B.van der MeiH. C.BusscherH. J.HooymansJ. M.BruinsmaG. M.2004Physicochemical factors influencing bacterial transfer from contact lenses to surfaces with different roughness and wettability.J Biomed Mater Res.B Appl.Biomater.7133642.
  126. 126. WagnerV. E.IglewskiB. H.2008P. aeruginosa Biofilms in CF Infection. Clin.Rev.Allergy Immunol.3512434.
  127. 127. WangH.FengH.LiangW.LuoY.MalyarchukV.2009Effect of surface roughness on retention and removal of Escherichia coli O157:H7 on surfaces of selected fruits. J Food Sci 74, E8-E15.
  128. 128. WebsterT. J.TongZ.LiuJ.KatherineB. M.2005Adhesion of Pseudomonas fluorescens onto nanophase materials. Nanotechnology 16, S449-S457.
  129. 129. WeisbarthR. E.GabrielM. M.GeorgeM.RapponJ.MillerM.ChalmersR.WintertonL.2007Creating antimicrobial surfaces and materials for contact lenses and lens cases. Eye Contact Lens334269.
  130. 130. WhittakerG.2008Biofinity silicone hydrogels.www.opticianonline.net1920.
  131. 131. WilkinsonS. G.1983Composition and structure of lipopolysaccharides from Pseudomonas aeruginosa.Rev.Infect.Dis. 5 Suppl 5, S941-S949.
  132. 132. WillcoxM. D.2007Pseudomonas aeruginosa infection and inflammation during contact lens wear: a review.Optom.Vis.Sci.842738.
  133. 133. WillcoxM. D.HarmisN.CowellWilliams. T.Holden2001Bacterial interactions with contact lenses; effects of lens material, lens wear and microbial physiology.Biomaterials22323547.
  134. 134. WillcoxM. D.NaduvilathT. J.VaddavalliP. K.HoldenB. A.OzkanJ.ZhuH.2010Corneal erosions, bacterial contamination of contact lenses, and microbial keratitis. Eye Contact Lens363405.
  135. 135. WindeckerR.TizianiH. J.1999Optical roughness measurements using extended white-light interferometry. Opt Eng3810817.
  136. 136. YangS.ZhangH.HsuS. M.2007Correction of random surface roughness on colloidal probes in measuring adhesion.Langmuir231195202.
  137. 137. YoungG.VeysJ.PritchardN.ColemanS.2002A multi-centre study of lapsed contact lens wearers. Ophthalmic Physiol Opt2251627.
  138. 138. ZolfagharI.AngusA. A.KangP. J.ToA.EvansD. J.FleiszigS. M.2005Mutation of retS, encoding a putative hybrid two-component regulatory protein in Pseudomonas aeruginosa, attenuates multiple virulence mechanisms.Microbes.Infect.7130516.
  139. 139. ZolfagharI.EvansD. J.FleiszigS. M.2003Twitching motility contributes to the role of pili in corneal infection caused by Pseudomonas aeruginosa. Infect.Immun.71538993.
  140. 140. ZolfagharI.EvansD. J.RonaghiR.FleiszigS. M.2006Type III secretion-dependent modulation of innate immunity as one of multiple factors regulated by Pseudomonas aeruginosa RetS.Infect.Immun.7438809.
  141. 141. ZyrianovY.2005Distribution-based descriptors of the molecular shape.J Chem.Inf.Model.4565772.

Written By

Maria Jesus Giraldez and Eva Yebra-Pimentel

Submitted: November 28th, 2011 Published: September 19th, 2012