Muscles modelled on each skeletal chain (acronyms in the nomenclature section)
1. Introduction
Most of human mechanical interactions with the surrounding world are performed by the hands. They allow us to perform very different tasks; from exerting high forces (e.g. using a hammer) to executing very precise movements (e.g. cutting with a surgical tool). This versatility is possible because of a very complex constitution: a great number of bones connected through different joints, a complicated musculature and a dense nervous system. This complexity is already evident from the kinematics point of view, with more than 20 degrees of freedom (DOF) controlled by muscles, tendons and ligaments.
Mathematical representations are used in order to perform qualitative or quantitative analyses on this complex reality. These representations are known as biomechanical models of the hand. In biomechanics, their use allows studying problems that cannot be analysed directly on humans or that have an experimental cost that is too high; e.g., the study of new alternatives for restoring hand pathologies. Biomechanical models are a description of the hand as a mechanical device: the different elements of the hand are defined in terms of rigid bodies, joints and actuators, and the mechanical laws are applied. As they are simplified mathematical models of the reality, their use and validity depends on the simplifications considered.
The first biomechanical models of the hand were developed to explain and clarify the functionality of different anatomical elements. In this regard, we can find many works that studied the function of the intrinsic muscles (Leijnse & Kalker, 1995; Spoor, 1983; Spoor & Landsmeer, 1976; Storace & Wolf, 1979, 1982; Thomas et al., 1968) and many others that tried to give an insight into the movement coordination of the interphalangeal joints (Buchner et al., 1988; Lee & Rim, 1990). Models for studying the causes and effects of different pathologies of the hand also appeared early on, such as the swan neck and boutonnière deformities or the rupture of the triangular ligament or the volar displacement of the extensor tendon (Smith et al., 1964; Storace & Wolf, 1979, 1982). All these models were, though, very limited, two-dimensional models allowing only the study of flexion-extension movements, they modelled only one finger, and they included important simplifications. By the year 2000, few three-dimensional models had been developed (Biryukova & Yourovskaya, 1994; Casolo & Lorenzi, 1994; Chao et al., 1976; Chao & An, 1978; Esteki & Mansour, 1997; Mansour et al., 1994; Valero-Cuevas et al., 1998), and none of them modelled the complete hand.
Since 2000, many three-dimensional biomechanical models can be found in literature, having been developed for very different purposes (Fok & Chou, 2010; Kamper et al., 2006; Kurita et al., 2009; Lee et al., 2008a, 2008b; Qiu et al., 2009; Roloff et al., 2006; Sancho-Bru et al., 2001, 2003a, 2003b, 2008; Valero-Cuevas, 2000; Valero-Cuevas et al., 2000, 2005; Vigouroux et al., 2006, 2008; Wu et al., 2010): to understand the role of the different anatomical elements, to understand the causes and effects of pathologies, to simulate neuromuscular abnormalities, to plan rehabilitation, to simulate tendon transfer and joint replacement surgeries, to analyse the energetics of human movement and athletic performance, to design prosthetics and biomedical implants, to design functional electric stimulation controllers, to name a few. These models, however, do not differ much from the ones developed before 2000, and many limitations are still evident. For example, contact forces and zones need to be measured experimentally and input to the model.
In contrast, much research has been carried out on animation techniques over the past years, mainly for use in developing computer games. Lately, these advances have been cleverly used by some ergonomics researchers to develop improved graphical and kinematics hand models for evaluating the use of products (Endo et al., 2007, 2009; Goussous, 2007; Kawaguchi, 2009), with good results.
On the other hand, robot hand grasps have been extensively studied for years. Although until 2000 little attention was paid to human hand grasping, this too has become a hot topic in robotics. The experience in modelling the robot hand grasps has been used to reach a better understanding of human grasping (Miller & Allen, 2004; Peña-Pitarch, 2007). The hand is considered as the end-effector for humans. These models, however, are not appropriate for studying many of the above-mentioned objectives, as their interest is different. The focus in robotics research is on planning the grasp and finding an optimum grasp, and quality grasp measures that have been developed for robots are used. These models do not include muscles and tendons in the formulation.
The latest developments in ergonomic hand models and human hand grasp models can be used to improve the existing biomechanical models of the hand and extend their functionality. A promising research area lies ahead with scientist, aiming to obtain a more comprehensive model of the hand, integrating knowledge and developments from the fields of biomechanics, ergonomics, robotics, and computer animation.
In this chapter, a review of the literature regarding biomechanical models of the hand, ergonomics hand models and human hand grasp models is presented. The three approaches are used to draw out the rules for developing an improved biomechanical model, able to tackle any of the above-mentioned objectives in a virtual environment, without external experimental data.
2. Literature review
2.1. Biomechanical models of the hand
Over the years, biomechanical models of the hand have been developed for different purposes. Some of them tried to study the functionality of different anatomical elements with the aim of gaining a deeper understanding of the causes and effects of many hand pathologies. These are usually very simplified (mostly two-dimensional) kinematic models (sometimes dynamic) that are used to perform qualitative analyses (Leijnse et al., 1992; Storace & Wolf, 1979). Others were developed to help in medical planning and surgery for patients; they are usually dynamic models and are used to perform quantitative analyses, such as the study of the tendon excursions in the medical planning of tendon transfers (Giurintano & Hollister, 1991) or to study the nervous stimulation required to restore the grasping ability in muscular dysfunction patients (Esteki & Mansour, 1997). Yet others studied the hand while performing specific tasks with different aims, so as to have approximate values for the articular forces for testing prosthetic designs (Weightman & Amis, 1982). These too are quantitative analyses performed on dynamic models.
Recent models do not differ much from the ones developed before 2000 (Fok & Chou, 2010; Kamper et al., 2006; Kurita et al., 2009; Lee et al., 2008a, 2008b; Qiu et al., 2009; Roloff et al., 2006; Sancho-Bru et al., 2001, 2003a, 2003b, 2008; Valero-Cuevas, 2000; Valero-Cuevas et al., 2000, 2005; Vigouroux et al., 2006, 2008; Wu et al., 2010). All models present a similar configuration. The kinematics are modelled without considering the restraining structure, just the resultant physiological articular movement. The concept of instantaneous centre of rotation has been used to define an axis of rotation in joints with a single predominant DOF. Much effort has also been spent on finding the rotation axes of joints with two DOF (Brand & Hollister, 1992), through the consideration of a virtual link connecting the axes (Giurintano et al., 1995). Thus, all works use fixed axes of rotation; depending on the joint, one or two axes of rotation are considered. This approximation has been found to be good enough for most of the cases, particularly if there is no interest in analysing the role of the articular soft tissue or the articular stresses (Youm et al., 1978).
All works in the literature consider the ideal case of a non-friction belt around a pulley to model the tendons on a joint. Therefore, the tensional force on a tendon is the same along its pathway if no split or connection to other tendon exists. Two different approaches have been used to model tendon action on the joints. The first one considers the tendon freely running when crossing the joint between two points attached one to the proximal segment of the joint and the other to the distal segment. This approach is the basis of the first serious attempt to develop a 3D normative model of the hand (An et al., 1979), in which the position of the tendons with respect the bone segments were obtained from the measurement on 10 fresh cadaveric specimens. The second approach comes from the application of the virtual work principle and considers the moment arm created by the tendon as the first derivative of the tendon excursion with respect to the rotated angle about the rotation axis under study (Storace & Wolf, 1979). This second approach is not strictly correct (Casolo & Lorenzi, 1994), as it does not take into account the work due to the deformation of the sheaths and other structures that constrain the tendon’s trajectory along its pathway. Although both approaches present advantages and disadvantages, the second one is difficult to implement in 3D modelling, mainly because of the complexity in the tendon excursion calculation at joints with more than one DOF.
Most of the works in the literature use Hill’s model to account for the muscles’ mathematical modelling. This simple model allows the consideration of the three main parameters, i.e., muscle activation level and variation of the maximum deliverable muscle force with muscle length and muscle contraction velocity.
Finally, the dynamic equilibrium equations lead to an indeterminate system of equations, with more unknowns (muscle forces) than available equations. Inequality constraints taking into account the maximal forces that may be delivered by each muscle and that tendons cannot support compressive forces have to be considered as well. The problem is usually solved by minimising some cost function. Different functions have been investigated, most of them without any physiological basis. The most often used criterion is the minimisation of the sum of the squared muscle stresses, which has been related to the maximisation of fatigue resistance (Crowninshield & Brand, 1981).
All the effort in biomechanics has been focused on appropriately modelling the different hand components (kinematics, muscles, tendons, etc.). Little effort has been spent on the formulation of the grasping problem when using a biomechanical model. In this sense, many limitations persist. Current models do not allow the estimation of the contact information required to use biomechanical models for simulating the grasping of objects. Forces and zones of contact still need to be measured experimentally and input to the model.
2.2. Hand models in ergonomics
Ergonomics, according to the International Ergonomics Association, is ‘the scientific discipline concerned with the understanding of interactions among humans and other elements of a system, and the profession that applies theory, principles, data and methods to design in order to optimise human well-being and overall system performance’. Hand models in Ergonomics are used to simulate postures adopted while grasping objects with different purposes. One of the main goals of physical ergonomics is the study of the size and shape of objects according to the anthropometry of the different people that have to interact with them. Thus, the main feature of a model for Ergonomics is that it has to allow representing different populations and percentiles. People having hands of different sizes and proportions will adopt different postures in grasping the same object for the same functions. For example, pressing a button of a phone with the thumb while holding it with the same hand can be easily achieved for a specific hand size while keeping the grasp. However, other people with different size of hand will need to change the grasping posture to achieve pressing the button. This is a typical problem of reach that needs to be solved in ergonomic assessment.
In recent years, virtual humans have been incorporated into the design process for ergonomic assessment of different types of products, mainly in the aerospace and automotive industry but also in others like product design, tasks simulation, personnel training or simulation of other worker environments (Colombo & Cugini, 2005; Yang et al., 2007). Several commercial software programs such as Jack, RAMSIS, HumanCAD, Safework and SantosHuman are available and other studies have been conducted on digital human models such as SAMMIE (Case et al. 1990) or the Boeing Human Modeling System for the same purposes. A virtual human in these packages is defined as a kinematic chain composed of a number of rigid links connected by joints. These joints have the DOF and allowable motion limits corresponding to the anatomical joint of the human being. Direct and inverse kinematics is incorporated into the models so they can replicate human body movements and also evaluate forces acting in joints. Moreover, different population and percentiles may be selected for the size of the model, usually from known anthropometric databases. With these capabilities the problems of reach and clearance usual in ergonomics may be solved easily. Other useful capabilities of these models are the simulation of the sense of sight with virtual cameras located in the eyes or the possibility to change any particular data of the model, like dimensions of limbs or motion limits of some joints, in order to simulate a particular person or disability. However, the majority of these models focuses on the whole body and does not pay attention to the accuracy of the hand model. Most of them just incorporate a list of hand postures (grasping or others) to be chosen, i.e. direct kinematics, but do not allow for example inverse kinematics for the joints of the hand, even when it is incorporated for the other joints of the body. In recent developments some attempts to improve the hand model incorporated into some programs have been done (Peña-Pitarch, 2007, Yang et al., 2007).
Early models of the hand (Davidoff & Freivalds, 1993) were actually kinematic models that simulated roughly the external geometry of the hand and its movements. The geometry of the hand has been modelled mainly by jointed cylinders (Fig. 1) and cones (Armstrong, 2009; Sancho-Bru et al., 2003a, 2003b). However, if the geometry of the hand model is not very accurate, the algorithms for inverse kinematics are not precise enough. Recently, some efforts have been made in accurately modelling the surface of real hands to be incorporated into 3D hand models. Rhee et al. (2006) presented an automated method to make a specific human hand model from an image of the palm of the hand. Different algorithms were used in the process: principal creases are extracted, joint locations are estimated from them and the skin geometry of a generic hand model deformed based on hand contours. Rogers et al (2008) made a scalable 3-D geometric model of the hand based on 66 landmarks of the palm surface from 100 subjects in four functional postures. The purpose was to analyse the deformation of the palm surface during the grasp of an object. Recent models incorporate the surface of the hand as a mesh object with more or less realism, obtained from the location of a number of landmarks of the hand or from digital 3D-scanning of the hand (Endo et al., 2007; Peña-Pitarch, 2007, van Nierop et al., 2008). The mesh is linked to a skeleton whose movement controls the deformation of the mesh with different types of algorithms.
Other important aspect of hand models for ergonomics is associated with the study of musculoskeletal disorders. Early epidemiological studies (Mital and Kilbom, 1992) showed that the use of hand tools with an improper design for the worker or the task could lead to a high risk of developing cumulative hand trauma disorders (CHTD). The factors influencing the development of CHTD have been reported in different works (Keyserling, 2000; Kong et al., 2006; Muggleton et al., 1999; Schoenmarklin et al., 1994; Spielholz et al., 2001) and different methods have been used in these studies: epidemiological studies, physiological measurements (electromyography activity, pressure in tissues, posture of hand and wrist, tactile sensitivity), biomechanical models of hand and wrist structures and psychophysical assessments. These studies report that CHTD are associated with repetitive tasks, high forces, extreme or awkward postures of hand and wrist, velocity and acceleration of wrist motions and exposure time, among others. Different theories of injury development have been proposed (Kumar, 2001). All of them assume that CHTD and other musculoskeletal disorders are of biomechanical nature.
Therefore, biomechanical hand models able to predict movements, postures and internal forces of hand and wrist structures can be used to assess the risk of developing CHTD. Tendon excursions or maximum gripping strength have been used as index in different works to assess gripping posture for health (Armstrong et al., 2009, Sancho-Bru et al., 2003b).
None of the reported biomechanical models of the hand for ergonomics accounts for all the above-mentioned requirements, although some attempts have been made. Armstrong et al (2009) have developed a scalable kinematic model of the hand with simple geometry (cones and cylinders). The model includes a posture prediction algorithm for fingers that reproduces in a high percentage the observed postures and is able to compute tendon excursions and wrist movements. The model is used to assess how much space is required for hands in an assembly task and to calculate the risk of CHTD from tendon forces and hand strength. Other group of researchers (Endo et al 2007, 2009; Kawaguchi et al., 2009) have developed a scalable digital hand model with an accurate shape of the hand that includes a semiautomatic grasp planning function with robotics indexes of quality (see next section). The model incorporates a ‘comfort database’ obtained from experimental measurements to assess comfort of postures and is used in the assessment of physical interaction with electronic appliances.
2.3. Grasping in robotics
For many years the robotics community has been studying the autonomous handling of objects by robots. A robot should be able to locate the object and then grasp it, and possibly transport it to a specified destination. The purpose of a grasp is to constrain the potential movements of the object in the event of external disturbances. For a specific robotic hand, different grasp types are planned and analysed in order to decide which one to execute.
A grasp is commonly defined as a set of contacts on the surface of the object. A contact model should be defined to determine the forces or torques that the robot manipulator must exert on the contact areas. Most of the work in robotics assumes point contacts, and larger areas of contact are usually discretised to follow this assumption (Bicchi & Kumar, 2000).
Two main problems can be distinguished in robotic grasping: analysis and synthesis (Mason, 2001). Grasp analysis consists on finding whether the grasp is stable using common closure properties, given an object and a set of contacts. Then, a quality measure can be evaluated in order to enable the robot to select the best grasp to execute. On the other hand, grasp synthesis is the problem of finding a suitable set of contacts given an object and some constrains on the allowable contacts.
In the following sections, a detailed description of the contact models and the most common approaches for grasp analysis and synthesis is presented.
2.3.1. Grasp contact models
A contact can be defined as a joint between the finger and the object. Their shape, stiffness and frictional characteristics define the nature of this joint (Mason, 2001). The force applied by a finger at a contact point generates a
A
A
Finally, the soft contact model is used to model the contact between a soft finger and a rigid object allowing the finger to apply an additional torsional moment with respect to the normal at the contact point (Ciocarlie et al., 2005, 2007; Howe et al., 1988; Howe & Cutkosky, 1996; Kao & Cutkosky, 1992; Kao & Yang, 2004). A typical contact between a soft finger and a contact surface can be modelled by the Hertzian contact model (Hertz, 1882; Johnson, 1985). However, robotic fingertips are made of nonlinear elastic materials. For that reason, the Hertzian contact model does not accurately represent this contact. In Xydas & Kao (1999) and Xydas et al. (2000) a power-law theory is presented for modelling nonlinear elastic contacts present in robotic fingers. It subsumes the Hertzian contact theory. More realistic, and complicated, models have been developed in the last few years that better represent the contact mechanics for soft fingers (Ciocarlie et al., 2005, 2007; Gonthier, 2007). However, it is the hard finger contacts with friction that are used more often in robotics.
2.3.2. Grasp analysis
After establishing the contact model, the set of contacts defining each grasp can be analysed in order to test its ability to resist disturbances and its dexterity properties. As it is presented afterwards, a grasp can resist disturbances in any direction if it fulfils one of the two closure conditions
Disturbance resistance
The first test for evaluating a grasp consists of determining its ability to constrain the motions of the manipulated object and to apply arbitrary contact forces on the object without violating friction constraints at the contacts (Bicchi, 1995). Two commonly used properties have been proposed to ensure this condition: force and form closure. A grasp is in
Form closure is a stronger condition than force closure and it is mostly used when executing power grasps (Siciliano & Khatib, 2008). Force closure is possible with fewer contacts, making it suitable for executing precision grasps, but it requires the ability to control internal forces.
In order to verify the form or force closure property of a grasp, many tests have been proposed (see Liu et al. (2004b) and Roa Garzón (2009) for a review). Most of them define conditions to be satisfied by the grasp wrenches in the wrench space. A
Measures of grasp performance
Many approaches have been proposed to measure the quality of a grasp. Some of the measures focus on evaluating the ability to resist external disturbances, others on evaluating the dexterity. These measures can be classified into two groups depending on whether they consider the location of the contact points on the object or the configuration of the end-effector. There are also some that are a combination of these two approaches (see Roa Garzón (2009) for a thorough review).
Measures from the first group take into account the geometric properties of the objects, their materials and closure properties to evaluate the grasp. For example, Li & Sastry (1998) proposed to calculate the smallest singular value of the grasp matrix, which indicates how far the grasp configuration is from losing the capability of withstanding external wrenches. Others have proposed to favour the grasps whose contact points are distributed in a uniform way on the object surface, which improves their stability (Mirtich & Canny, 1994; Park & Starr, 1992). This can be done by measuring either the angles or the area of the polygon whose vertices are the contact points. The centroid of this polygon is also used to calculate its distance to the object centre of mass (Ding et al., 2001; Ponce et al., 1997). The smaller this distance the better the grasp can resist the effect of external forces. In addition, some other measures take into account the uncertainty in the position of the fingers; therefore instead of contact points they calculate contact regions in which force closure grasps are assured (Nguyen, 1988; Roa Garzón, 2009). The quality of the grasp is measured by the size of these regions.
The previous approaches do not consider any limitation on the finger forces, so that in some cases the fingers have to apply very large forces to resist small perturbations. Other measures do consider limitations on the magnitudes of the finger forces. They can limit the force on each finger or the sum of forces applied by all fingers. Ferrari & Canny (1992) used the largest ball not only to evaluate grasp closure but also to measure the grasp quality. This is a geometric representation of the smallest perturbation wrench that breaks the grasp, independently of its direction. It has been widely used by the robotics community (Borst et al., 2003; Miller & Allen, 1999; Roa Garzón, 2009). The volume of the ball is also considered as a quality measure with the advantage that it remains constant independently of the used torque reference system (Miller & Allen, 1999).
When a task is specified to be performed after the object is grasped, the quality of the grasp can be measured with its ability to counteract the expected disturbances during the task execution. The set of all wrenches that are expected to be applied on the object defines the
On the other hand, there are measures that consider the configuration of the end-effector, requiring the hand-object Jacobian for their calculation (Roa Garzón, 2009). An example of this group is a measure that favours a grasp that, given certain velocities in the finger joints, produces the largest velocities on the grasped object, calculated with the volume of the manipulability ellipsoid (Yoshikawa, 1985). There is another measure that penalises the joints of the hand being in their maximum limits, calculating the deviation of the joint angles from their centres (Liegeois, 1977). Additionally, there are other measures in this group that also consider the task, giving higher quality indexes to the grasps which ensure the maximum transformation ratio along the direction wrenches more likely to be applied on the object when executing it (Chiu, 1988).
2.3.3. Grasp synthesis
Given an object, grasp synthesis algorithms should provide a suitable set of contacts on the object surface and determine an appropriate hand configuration. Usually they take the geometry of the object as an input to select optimal force-closure contact locations. These contacts are the starting point for grasp analysis and dexterous manipulation methods.
Some approaches give only information about the finger contact locations on the object without considering the hand constraints. They can result in stable grasps that are not reachable in practice by the robot hand. Moreover, even if they are reachable, it is difficult to position the fingers precisely on the contact points because there will be always unavoidable errors locating the end-effector (Morales et al., 2006).
Alternative approaches, called knowledge-based approaches, have considered the configuration of the hand by generating the grasp with a predefined set of hand postures. The idea of hand preshapes started with studies of the human prehension capabilities (Napier, 1956) that introduced the distinction between power and precision grasps. Following this work, Cutkosky (1989) created a taxonomy in which details of the task and the object geometry are taken into account. Since then, several papers have adopted this approach for grasping (Morales et al., 2006; Stansfield, 1991; Wren, 1995). Miller et al. (2003) used a simulator called GraspIt! to test the set of hand preshapes on a 3D model of the object. Using a simulator has many advantages, including the ability to plan grasps in complex environments involving obstacles and also to check the reachability constraints of the robot arm. More recently OpenRAVE, a planning architecture that has a more flexible design, has been proposed to automate this process (Diankov, 2010).
Despite many years of research and all the advances we have reviewed, the robotics community is still not able to build a manipulator with similar capabilities to the human hand. The robot hands constructed until now are only simplifications (Fig. 3), given the complexities not only at the sensor and actuator level, but also at the control level. They vary from the easiest to control, such as 2-jaw grippers, to more anthropomorphic hands like the Salisbury Hand, the Utah-MIT Hand, the Barrett Hand, the ARMAR III Hand or the DLR Hand II (see Biagiotti et al. (2002) and Parada et al. (2008) for a review).
3. Hand biomechanical model proposal
In this section, the current knowledge on biomechanical, ergonomics and robotics hand models is used to draw out the rules for developing a realistic and self-contained biomechanical model of the hand.
Based on the literature review, current hand biomechanical models allow estimating the muscular patterns required to perform a movement while counteracting a system of external forces. But their use for studying object grasping is limited. On the one hand, biomechanical
models lack realism for assessing the use of handheld products from an ergonomics point of view. Hand models in ergonomics have reached a high level of realism but do not allow for mechanical analyses. On the other hand, biomechanical models are not self-contained, as they need contact information to be input to the model. Current models do not allow predicting grasping postures nor evaluating contact forces and zones, much less predicting the movements while grasp planning. Quality grasp measures in robotics allow comparing different robotic grasping postures and could be adapted to human grasping.
A detailed proposal for modelling the different components of the hand is provided below: joints-kinematics, muscles, ligaments and passive tissues, skin, contact with objects and neuromuscular control. The features that we require in order to create a model are:
The model has to simulate the complete hand in order to allow the study of any grasp.
The model has to be scalable to allow the simulation of different population groups.
The model has to simulate and show the grasping of an object in a realistic way.
The model has to estimate the muscular patterns required to perform a movement while counteracting the system of external forces that define the object manipulation. Furthermore, the model has to estimate the articular forces at the hand joints.
The model has to be dynamic in order to allow the study of any grasping task (slow or fast) during the object manipulation.
The model has to predict feasible grasping postures for a given object and provide the contact information required for evaluating the grasp
The model has to incorporate quality grasping measures for evaluating the grasp.
The model proposed in this section has been developed in a scalable way, choosing two very well known anthropometric parameters of the hand that are easy to measure and representative of the hand size. The parameters are the hand length (HL) and hand breadth (HB) and are shown in Fig. 4.
3.1. Kinematics
In order to achieve realistic grasping postures, care has to be taken when selecting the appropriate DOF among the different hand bones. The DOF have to allow the hand model to reach the hand posture for any grasping task. In this sense, it is important that the model considers not only the thumb and finger movements but also the palm arching.
The hand has been considered as five skeletal open chains of rigid bodies connected to the carpus through different joints which characterise the kinematic behaviour of the chains.
Distal and proximal interphalangeal (DIP and PIP) joints of the fingers as well as the interphalangeal (IP) joint of the thumb are trochlear joints, capable only of flexion/extension movements (Brand & Hollister, 1992). These joints are modelled as one DOF joints by means of defining a rotation axis connecting the adjacent phalanxes (hinge joint).
Thumb and fingers metacarpophalangeal (MCP) joints are condylar joints, capable of flexion/extension and abduction/adduction movements (Brand & Hollister, 1992). The thumb carpometacarpal (CMC) joint is a saddle joint, capable also of flexion/extension and abduction/adduction movements (Brand & Hollister, 1992). All these joints are modelled as two DOF joints by defining two axes of rotation connecting the adjacent segments. The axes are neither intersecting nor orthogonal (Brand & Hollister, 1992), so that a virtual link is used to connect both axes (Giurintano et al., 1995).
Finally, the hand model allows the arching of the palm by modelling the CMC joints of the little and ring fingers. These joints are arthrodial joints, with a very limited range of movement (Kapandji, 1998). They have been modelled as one DOF joints by means of defining a flexion/extension axis of rotation connecting the carpus to each metacarpal. The orientation of the axes is defined oblique in order to appropriately simulate the arching of the palm (Kapandji, 1998). Due to the important role that the shape of the palm plays in grasping, this model is considered more suitable for grasping simulation than others in the literature.
The data for the location and orientation of the rotation axes comes from An et al. (1979), Buchholz et al. (1992) and Hollister et al. (1995). Axes data and link lengths are fully scaled with respect to the hand length and hand breadth (Sancho-Bru, 2000). Limits for the joints have been obtained from Tubiana (1981) and Tubiana et al. (1996).
In order to study the forward and inverse kinematics of the hand, the Denavit- Hartenberg method from the robotics field (Denavit and Hartenberg, 1955) was adapted to define the position of any segment point.
3.2. Musculo-tendon action
Muscles and tendons control the movement of the skeletal chains. Muscles have been considered using a simple Hill three-component model (Hill, 1938) that takes into account the muscle activation level (α) and the force-length and force-velocity relationships, as well as the different index of architecture of muscles. The model considers a contractile element (CE), which is the basic component that generates force, a parallel elastic element (PEE), which is responsible for the passive force generated by the muscle when it is stretched, and a series elastic element (SEE), the muscle tendon unit, which has been considered to be inextensible (Fig. 5).
The force a muscle can exert depends on the actual muscle length and contraction velocity. It is widely accepted (An et al., 1991) that the maximum force a muscle can exert in optimal conditions is proportional to its physiological cross-sectional area (PCSA):
where
The strain of tendons is insignificant for the magnitude of forces developed by the muscles (Goldstein et al., 1987). Under this consideration, the SEE has been considered to inextensible, so that the force the muscle exerts (
where
The force exerted by the muscle can be decomposed into an active force and a passive force corresponding to the forces delivered by the CE and PEE, respectively. The force delivered by the CE is related to the muscle architecture and is a function of the muscle length
where
A characteristic bell-shaped curve exists between force and length of the muscle. To model this dependence, the expression proposed by Kaufman et al. (1991) has been used:
where
The force a muscle can exert decreases when the contraction velocity of the muscle fibres increases. To model this dependence the expression proposed by Hatze (1981) has been used
where
The force generated by the PEE is a function only of its length. An exponential relationship has been considered in this case (Lee & Rim, 1990; Kaufman et al., 1991), with
The scalability of the muscular action is achieved by scaling the PCSA of the muscles with respect to the product of hand length and hand breadth parameters (Sancho-Bru et al., 2008) from its value for
The muscles considered on each skeletal chain are listed in Table 1. PCSA data for index finger muscles have been taken from Valero-Cuevas et al. (1998); data for the remaining muscles have been obtained from Brand & Hollister (1992). Muscle stress limit (
Index | Medial | Ring | Little | Thumb |
1st FP | 2nd FP | 3rd FP | 4th FP | APB |
1st FS | 2nd FS | 3rd FS | 4th FS | FPB |
1st EDC+EI | 2nd EDC | 3rd EDC | EDQ | OPP |
1st LU | 2nd LU | 3rd LU | 4th LU | ADD |
1st DI | 2nd DI | 4th DI | 3rd VI | 1st DI |
1st VI | 3rd DI | 2nd VI | FDQ | APL |
ADQ | EPB | |||
FPL | ||||
EPL |
Most of the muscles do not act directly on the bones, but transmit the force to the tendons, which finally insert into the bones. To model the tendon action crossing the joints, straight lines connecting 2 points have been considered, one fixed with respect to the proximal bone and the other one with respect to the distal bone (Fig. 6a). This approximation has been found to be close enough to the behaviour of all tendons with the exception of extensors (An et al., 1979), for which Landsmeer’s model I has been considered (Fig. 6b). The data for the points defining the tendon actions have been obtained from An et al. (1979).
The extensor hood mechanisms of the fingers are modelled as a tendon net. The net allows for the connection and division of the tendon paths. The insertions and connection points considered for the tendon nets on each skeletal chain are shown in Fig. 7. Appropriate force balances have been considered in the connecting points of this deformable tendon net. Second DI, fourth DI and ADQ tendons do present a double insertion into the proximal phalanxes and into the extensor aponeuroses. A force distribution proportional to the amount of fibres of each branch (Eyler & Markee, 1954) has been considered.
The muscle force-length and force-velocity relationships presented above require the calculation of the lengthening of the muscles from
The data for the location of the points defining the tendon paths comes from An et al. (1979) and Buchholz et al. (1992), and are also scaled with respect to the hand length and hand breadth (Sancho-Bru, 2000).
3.3. Ligaments
In previous work, we showed the importance of modelling the effect of ligaments for studying free finger movements. In the case of grasping, their consideration is not so relevant. Their effect can be neglected for studying power grasps, but they can play an important role in the case of some precision grasps, particularly those involving fast movements.
In the case of DIP and PIP joints of fingers and thumb, the insertion of the collateral ligaments on the proximal segment of the joint corresponds to the flexion-extension axis (Dubousset, 1981). Therefore, they do not develop any flexion-extension moment over the joint and they do not need to be modelled. In the case of MCP joints, the proximal insertion of the lateral ligament on the metacarpal head remains dorsal to the center of the articular curvature (Fig. 8), so that collateral ligaments are lax in extension, but they become taut in flexion, decreasing significantly the range of lateral movement (Craig, 1992; Dubousset, 1981; Kapandji, 1998). Tension on the radial and ulnar ligaments increases with adduction and abduction of the MCP joint, respectively. Furthermore, the line of action of the ligaments remains dorsal to the flexion- extension axis of the joint (Craig, 1992), developing an extension moment over the joint, in addition to the abduction-adduction moment.
Both ulnar and radial ligaments over MCP joints have been considered. A unique fibre for each ligament has been considered, joining two points representing the insertions into the bones. One point is fixed with respect to the metacarpal, and the other one with respect to the proximal phalanx. No interaction between bone and ligament has been considered; therefore the ligament path is a straight line between the insertion points. Its non-linear behaviour has been taken into account considering a quadratic relationship between the force developed by the ligament (
where
The data for the ligament insertion points have been obtained from the geometric model presented in Youm et al. (1978), and the stiffness constant has been estimated to be 750 N/cm2 from Minami et al. (1985).
3.4. Skin and contact with objects
One of the applications of the biomechanical model is its use in assessing the use of handheld products from an ergonomics point of view. To accomplish that goal, the model has to incorporate a realistic model of the skin from the visual point of view. The advances in computer animation have made possible the development of a number of convincing surface skin models.
We propose to use a surface skin model similar to that of Endo et al. (2007) or Goussous (2007). The surface skin model is a 3-dimensional polygonal mesh for the hand surface generated from CT images. The geometry of the skin model is defined at only one opened posture. A surface skin deformation algorithm defines the deformed geometry of the surface skin model when the posture of the kinematic model is changed (Fig. 9). The algorithm assigns each bone a capsule-shaped
As stated before, the model has to simulate and show the grasping of an object in a realistic way. To satisfy this requirement, it is not enough to have a visually realistic model of the surface skin. The model must also be able to predict feasible grasping postures.
In order to generate grasp postures automatically, we propose to use a grasping algorithm based on that of Choi (2008). This algorithm uses a function to automatically generate a natural grasping motion path of the hand model from a fully opened state to a clenched one. The goal is to find contacts between the surface hand skin and the object surface while rotating the joint angles of the fingers. Care has to be taken to properly choose the rotation rate of the finger joints, as it affects the final posture prediction. Based on the results from Choi (2008), we propose to use a variable rotation algorithm, by describing rotations of all joints at observation-based rates. To select the appropriate rotation rate we propose the use of neural networks, similar to those used in Kyota et al. (2005) and Rezzoug & Gorce (2008). This will require intensive experimental work beforehand to record the postures for grasping objects (of different shapes, sizes, weights, etc.) when performing different tasks (power and precision). The experimental data have to be analysed in order to characterise the human grasp and find the parameters affecting the grasping posture. These parameters will be used as input to the neural network to estimate a tentative clenched posture. The rotation rate is defined by the difference between the angles of the fully opened state and the tentative clenched one.
In order to generate the grasp, a contact model is required. We need to check whether the surface skin model makes contact with the surface of the object model. In reality, the surface of a hand is deformed when making contact with the object. Generally, this deformation has a non-linearly elastic property, and it could be simulated using finite element analyses. But this would need a long execution time. This is unacceptable for our model where a large number of different grasp postures have to be generated and tested within a practical time.
Therefore, we propose to consider a simple geometric collision-detection algorithm based on the one used by Endo et al. (2007). The algorithm allows the penetration of the surface skin model and the object model. This penetration is limited by a tolerance that relates to the hand stiffness of each contact region.
The distances between the points on the skin surface and the object are calculated while the joint angles of each joint rotate according to the specific joint rotation algorithm. When the maximum penetration distance between the skin surface points and the object reaches the given tolerance, the contact is achieved and the joint rotation ends. When distal segments of all four fingers make contact with the object, the simulation terminates.
As we have mentioned previously, the model has to provide the contact information required for evaluating the grasp. If a classical robotics quality measure of the grasp is to be performed, the only data needed are the contact points and associated normal vectors at these points, which are easily obtained from the proposed contact model.
When trying to estimate the muscular pattern associated with a grasp, the model needs more contact information. The contact forces between the object and the hand have to be considered in this case. Unlike what happens with robots, real human fingers conform to the grasped object shape. As the contact finger surface is deformable the contact does not occur at just one point but over some finite area that increases as the normal forces increase. Due to this effect, in addition to the normal force and tangential force due to friction, human finger contact may support frictional torsional moments with respect to the normal at the contact point. This clearly shows that the consideration of rigid contact commonly used in robotics is not appropriate for use in studying the human grasp, and a soft contact has to be modelled. Most objects manipulated by human hands are much stiffer than human hands, and it is reasonable to consider the objects to be grasped as rigid bodies, and the hand as a deformable body.
Different soft contact models have been investigated and proposed in order to better account for this deformation effect in the context of soft finger contacts (Ciocarlie et al., 2005, 2007; Gonthier, 2007). In Ciocarlie et al. (2007) friction constraints are derived based on general expressions for non-planar contacts of elastic bodies, taking into account the local geometry and structure of the objects in contact. The following approximation can be used to express the constraint relating the magnitudes of frictional force (
where
where
The actual grasping forces for a given posture will be obtained by considering that they have to satisfy the dynamic equilibrium of the grasped object. There is not a unique set of forces that ensures the equilibrium but we have to take into account the biomechanical limitations (maximal muscle forces) and the control performed by the central nervous system. In an effort to minimise the computational cost, we propose to uncouple the computation of the contact forces from the neuromuscular control model. This can be done by considering that the central nervous system is trying to attempt performing the grasp with minimal contact forces, as implemented for robots in the work of Liu et al. (2004a).
3.5. Neuromuscular control
The movement of the skeletal chains, together with the contact forces and the corresponding application points are input to the model. The problem to be solved is the derivation of the muscle activation levels required to produce the given motion under the external loads. It is, therefore, an inverse dynamics problem.
The dynamics equations of the open chain of rigid bodies have been derived using the Lagrange method (García de Jalón & Bayo, 1994). For a system with
where
Eqs. 14 together with the force balances of the tendon nets lead to an indeterminate problem. For example, in the case of the index finger, there are 12 equations (four corresponding to the DOF considered and eight to force balances in the tendon net) and 18 unknowns (six muscle forces and 12 branch forces of the tendon net). There is not a unique combination of muscular efforts that satisfy the dynamic equilibrium constraints. To solve the problem, a criterion chosen by the central nervous system to determine the muscle action control must be introduced. Our proposal is to maximise the endurance. According to Crowninshield and Brand (1981), this is achieved by minimising the non-linear objective function
with
3.6. Grasp evaluation
A global grasp evaluation can be performed through the use of the proposed model, merging the knowledge from ergonomics, robotics and biomechanics. The classical ergonomics evaluation of grasp posture and reachability is possible, for different percentiles of the population represented by the corresponding anthropometric parameters. Furthermore, CHTD evaluation can be performed by using the predicted postures and muscle forces.
It is advisable to use force closure from robotics as a part of the proposed model; once a grasping posture is estimated by the grasping algorithm, force closure should be assured before consuming time in determining the contact forces. Any of the robotics quality measures could be used for evaluating the grasp. Depending on the task to be performed, it would be better to use a grasp quality measure to evaluate the disturbance resistance or a grasp quality measure to evaluate the manipulability.
But the most relevant contribution to grasp evaluation has to come from biomechanics analysis. Grasp measures related to the muscle and articular forces have to be investigated. Just to provide insight into this sense, and to ensure coherence with our model formulation, we propose the use of Eq. 15 as a quality measure related to fatigue that we can call
4. Conclusion
A realistic and self-contained biomechanical model of the hand has been proposed by merging the current knowledge of biomechanics, ergonomics and robotics. The model simulates the complete hand and can easily be scaled to study different percentiles of populations. It has a realistic representation that allows the ergonomic evaluation of products. The model is dynamic and can be used to study the muscular patterns associated with a specific grasp. It allows predicting feasible grasping postures and provides the contact information required for evaluating the grasp. Finally, the model incorporates original quality grasping measures such as the fatigue index and the muscle safety margin index, in addition to the usual robotics and ergonomics metrics and evaluations. All the abovementioned features are performed in a virtual environment, without external experimental data.
5. Nomenclature
3D | Three-dimensional | FP | Flexor profundus | |
ADD | Adductor pollicis | FPB | Flexor pollicis brevis | |
ADQ | Abductor digiti quinti | FPL | Flexor pollicis longus | |
APB | Abductor pollicis brevis | FS | Flexor superficialis | |
APL | Abductor pollicis longus | GWS | Grasp wrench space | |
CE | Contractile element | HB | Hand breadth | |
CHTD | Cumulative hand trauma disorders | HL | Hand length | |
CMC | Carpometacarpal | IP | Interphalangeal | |
DI | Dorsal interosseous | LU | Lumbrical | |
DIP | Distal interphalangeal | MCP | Metacarpophalangeal | |
DOF | Degrees of freedom | OPP | Opponens pollicis | |
EDC | Extensor digitorum communis | OWS | Object wrench space | |
EDQ | Extensor digiti quinti | PCSA | Physiological cross-sectional area | |
EFM | Elastic foundation model | PEE | Parallel elastic element | |
EI | Extensor indicis | PIP | Proximal interphalangeal | |
EPB | Extensor pollicis brevis | SEE | Series elastic element | |
EPL | Extensor pollicis longus | TWS | Task wrench space | |
FDQ | Flexor digiti quinti | VI | Volar interosseous |
Acknowledgments
We are grateful for the financial support of the Fundació Caixa-Castelló and the Universitat Jaume I throughout the project P1-1B2009-40; of the Spanish Research and Innovation Ministry, and the EU (FEDER funds) throughout the project DPI2010-18177; and of European Community’s Seventh Framework Programme through the project GRASP, IST-FP7-IP-215821. This research is related to these three projects.
References
- 1.
An K. N. Chao E. Y. Cooney W. P. Linscheid R. L. 1979 Normative model of human hand for biomechanical analysis. J, 12, 10,775 788 ),0021-9290 - 2.
An K. N. Chao E. Y. S. Kaufman K. R. 1991 Analysis of muscle and joint loads. In: Mow, V.C and Hayes, W.C. (Eds.), . Raven Press. Ltd., New York,1 50 . - 3.
Development of a Kinematic Hand Model for Study and Design of Hose Installation. , HCIIArmstrong T. J. Best C. Bae S. Choi J. Grieshaber D. C. Park D. Woolley C. Zhou W. 2009 LNCS 5620,85 94 , 2009. - 4.
Bernabeu J. Tornero J. 2002 Hough Transform for Distance Computation and Collision Avoidance, , 18, 3, (June 2002),393 398 ),0104-2296 X - 5.
Biagiotti L. Lotti F. Melchiorri C. Vassura G. 2002 Design Aspects for Advanced Robot Hands, IEEE/RSJ . Towards Intelligent Robotic Manipulation.,1 16 ) - 6.
Bicchi A. 1994 On the Problem of Decomposing Grasp and Manipulation Forces in Multiple Whole-limb Manipulation, 13, 2, (July 1994),127 147 ),0921-8890 - 7.
Bicchi A. 1995 On the Closure Properties of Robotic Grasping. , 14, 4, (August 1995),319 334 ),0278-3649 - 8.
Bicchi A. Kumar V. 2000 Robotic grasping and contact: a review, , IEEE,348 353 . - 9.
Biryukova E. V. Yourovskaya V. Z. 1994 A model of human hand dynamics. , Eds. F. Schuind,107 122 ), Plenum Press,0-30644-580-8 York. - 10.
Borst C. Fischer M. Hirzinger G. 2003 Grasping the dice by dicing the grasp,0-78037-860-1 Vegas, NV, USA, Octuber 2003Borst, C., Fischer, M. & Hirzinger, G. (2004). Grasp planning: how to choose a suitable task wrench space, Proc. IEEE ICRA, ISBN 0-7803-8232-3, New Orleans, LA, USA, April-May 2004 - 11.
Brand P. W. Hollister A. M. 1992 , Elsevier Science Health Science div, third edition, 13 Louis - 12.
Anthropometric data for describing the kinematics of the human hand.Buchholz B. Armstrong T. J. Goldstein . S. A. 353 3, (March 1992),261 273 ),0014-0139 - 13.
Buchner H. J. Hines M. J. Hemami H. 1988 A dynamic model for finger interphalangeal coordination. , 21, 6,459 468 ),0021-9290 - 14.
, SAMMIE: a man and workplace modelling system. Computer Aided Ergonomics, 1990, 31-56 (Taylor & Francis: London). ,Case ,K. Porter ,J.M. Bonney ,M.C. - 15.
Casolo F. Lorenzi V. 1994 Finger mathematical modelling and rehabilitation. En Advances in the Biomechanics of the Hand and Wrist, Eds. F. Schuind,197 223 , New York. Plenum Press. - 16.
Chao E. Y. Opgrande J. D. Axmear F. E. 1976 Three dimensional force analysis of finger joints in selected isometric hand functions. ,9 387 395 . - 17.
Chao E. Y. An K. N. 1978 Internal forces in human hand. , ASCE, 104 (EM1): 255-272. - 18.
Chiu S. L. 1988 Task compatibility of manipulator pustures. , 7, 5)13 21 ) - 19.
Choi J. 2008 Doctoral dissertation, University of Michigan. - 20.
Ciocarlie M. Miller A. Allen P. 2005 Grasp Analysis Using Deformable Fingers, 2005 IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS 2005) - 21.
Ciocarlie M. Lackner C. Allen P. 2007 Soft Finger Model with Adaptive Contact Geometry for Grasping and Manipulation Tasks,978-0-76952-738-3 Tsukuba, Japan, March 2007 - 22.
Colombo and Cugini, 2005 Virtual humans and prototypes to evaluate ergonomics and safety. Journal of Engineering Design, 16, 2, (April 2005),195 207 ),0954-4828 - 23.
Craig S. M. 1992 Anatomy of the joints of the fingers. 8, 4, (November 1992),693 700 ),0749-0712 - 24.
Crowninshield R. D. Brand R. A. 1981 A physiologically based criterion of muscle force prediction in locomotion. .14 793 801 . - 25.
Cutkosky M. 1989 On grasp choice, grasp models, and the design of hands for manufacturing tasks, IEEE Transactions on Robotics and Automation5 3 269 279 . - 26.
Davidoff and Freivalds, 1993 Davidoff N.A., Freivalds A. A graphic model of the human hand using CATIA. , 1993, 12 (4) 255-264 - 27.
Denavit J. Hartenberg R. S. 1955 ‘A kinematic notation for lower-pair mechanisms based on matrices’, ,77 215 221 . - 28.
Diankov R. 2010 Automated Construction of Robotic Manipulation Programs, PhD thesis, Carnegie Mellon University, Robotics Institute. - 29.
Ding D. Lee Y. H. Wang S. 2001 Computation of 3-d form-closure grasps, IEEE Transactions on Robotics and Automation17 4 515 522 . - 30.
Dubousset J. F. 1981 The digital joints. In: Tubiana, R. (Ed.), The Hand. Saunders Company, Philadelphia,191 201 . - 31.
Endo Y. Kanai S. Kishinami T. Miyata N. Kouchi M. Mochimaru M. 2007 Virtual grasping assessment using 3D digital hand model. 10th Annual Applied Ergonomics Conference: Celebrating the Past- Shaping the Future. - 32.
Endo Y. Kanai S. Miyata N. Kouchi M. Mochimaru M. Konno J. Ogasawara M. Shimokawa M. 2009 Optimization-Based Grasp Posture Generation Method of Digital Hand for Virtual Ergonomics Assessment. SAE Int. J. Passeng. Cars- Electron. Electr. Syst.1 1 590-598. - 33.
Erdmann M. A. 1994 On the representation of firction in configuration space. 13(3),240 271 . - 34.
Esteki A. Mansour J. M. 1997 A dynamic model of the hand with application in functional neuromuscular stimulation. ,25 440 451 . - 35.
Eyler D. L. Markee J. E. 1954 “The anatomy and function of the intrinsic musculature of the fingers”,36-A ,1 18 . - 36.
Ferrari C. Canny J. 1992 Planning optimal grasps,2290 2295 . - 37.
Development of a finger biomechanical model and its considerations. Journal of Biomechanics. 2010 Mar 3;43(4):701-13. ,Fok K.S. Chou S.M. - 38.
García de Jalón. J. Bayo E. 1994 Kinematic and dynamic simulation of multibody systems. Springer-Verlag, New York. - 39.
Giurintano D. J. Hollister A. M. 1991 Force analysis of the thumb for a five-link system. ASME Biomechanics Symposium,120 213 217 . - 40.
Giurintano D. J. Hollister A. M. Buford W. L. Thompson D. E. Myers L. M. 1995 A virtual 5-link model of the thumb. 17, 4, (June 1995),297 303 ),1350-4533 - 41.
Goldstein S. A. Armstrong T. J. Chaffin D. B. Matthews L. S. 1987 Analysis of cumulative strain in tendons and tendon sheaths. , 20 (1),1 6 . - 42.
Gonthier Y. 2007 Contact Dynamics Modelling for Robotic Task Simulation. Ph. d. thesis. University of Waterloo. - 43.
Grasp planning for digital humans. PhD dissertation. Iowa University.Goussous F. A. 2007EO - 44.
Harada K. Kaneko M. Tsuji T. 2000 Rolling Based Manipulation for Multiple Objects.3887 3894 . - 45.
Haschke R. Steil J. J. Steuwer I. Ritter H. 2005 Task-oriented quality measures for dextrous grasping. In: ,689 694 . - 46.
Hatze H. 1981 Myocibernetic control models of skeletal Muscle. University of South Africa, Pretoria. - 47.
Hertz H. 1882 On the Contact of Rigid Elastic Solids and on Hardness, Ch 6: Assorted Papers by H. Hertz. MacMillan, New York, 1882. - 48.
Hill A. V. 1938 “The of shortening and dynamic constants of muscle”, Proc R Soc London B,126 136 195 . - 49.
Hollister A. M. Giurintano D. J. Buford W. L. Myers L. M. Novich A. 1995 The axes of rotation of the thumb interphalangeal and metacarpophalangeal joints. , (320),188 193 . - 50.
Howe R. Kao I. Cutkosky M. 1988 Sliding of robot fingers under combined tornsion and shear loading. Proceedings ,103 105 . - 51.
Howe R. Cutkosky M. 1996 Practical force-motion models for sliding manipulation 15(6),555 572 . - 52.
Jacobson M. D. Raab R. Faxelo B. M. Abrams R. A. Botte M. J. Lieber R. L. 1996 Architectutural design of the human intrinsic hand muscles. , 17A (5),804 811 . - 53.
Johnson K. L. 1985 Contact Mechanics. Cambridge University Press. - 54.
Kamper D. G. Fischer H. C. Cruz E. G. 2006 Impact of finger posture on mapping from muscle activation to joint torque. Clinical Biomechanics.21 4 361 9 . - 55.
Kao I. Cutkosky M. 1992 Dexterous manipulation with compliance and sliding. 11(1),20 40 . - 56.
Kao I. Yang F. 2004 Stiffness and Contact Mechanics for Soft Fingers in Grasping and Manipulation. , 20(1),132 135 . - 57.
Kao I. Linch K. Burdick J. W. 2008 Contact Modeling and Manipulation. ,647 668 . - 58.
Kapandji A. I. 1998 . Editions Maloine, Paris. - 59.
Kaufman K. R. An K. N. Litchy W. J. Chao E. Y. S. 1991 Physiological prediction of muscle forces I. Theoretical formulation. J. Neuroscience 40 (3), 781-792. - 60.
Kawaguchi K. Endo Y. Kanai S. 2009 Database-Driven Grasp Synthesis and Ergonomic Assessment for Handheld Product Design. Lecture Notes in Computer Science,5620 2009, 642-652. - 61.
Keyserling W. M. 2000 Workplace risk factors and occupational musculoskeletal disorders, part 2: A review of biomechanical and Psychophysical research on risk factors associated with upper extremity disorders. AIHA Journal; Mar/Apr 2000; 61 (2) pg.231 243 - 62.
Kong Y. Jang H. Freivalds A. 2006 Wrist and Tendon Dynamics as Contributory Risk Factors in Work-Related Musculoskeletal Disorders. , 16, 1,83 105 ),1090-8471 - 63.
Kumar 2001 2001. Theories of musculoskeletal injury causation. Ergonomics, 2001,44 1 17 ± 47 - 64.
Biomechanical analysis of subjective pinching effort based on tendon-skeletal model. Conf Proc IEEE Eng Med Biol Soc.Kurita Y. Onoue T. Ikeda A. Ogasawara T. 2009 5231 4 2009 - 65.
Kyota F. Watabe T. Saito S. Nakajima M. 2005 Detection and Evaluation of Grasping Positions for Autonomous Agents. Proceedings of the 2005 International Conference on Cyberworlds (CW’05). - 66.
Lee J. W. Rim K. 1990 Maximum finger force prediction using a planar simulation of the middle finger. Proc. Instn. Mech. Engnrs. Part H: ,204 169 178 . - 67.
Lee S. W. Chen H. JD Towles Kamper. D. G. 2008a Effect of finger posture on the tendon force distribution within the finger extensor mechanism. . 130(5):051014. - 68.
Lee S. W. Chen H. JD Towles Kamper. D. G. 2008b Estimation of the effective static moment arms of the tendons in the index finger extensor mechanism. .41 7 1567 73 . - 69.
Leijnse J. N. A. L. Bonte J. E. Landsmeer J. M. F. Kalker J. J. Van Der Meulen J. C. Snijders C. J. 1992 ,25 11 1 253 . - 70.
Leijnse J. N. A. L. Kalker J. J. 1995 A two-dimensional kinematic model of the lumbrical in the human finger.28 3 237 249 . - 71.
Lemay M. A. Crago P. E. 1996 A dynamic model for simulating movements of the elbow, forearm and wrist. , 29 (19,1319 1330 . - 72.
Li Z. Sastry S. 1988 Task-oriented optimal grasping by multifingered robotic hands. , 4 (1),32 44 . - 73.
Validation of a three-dimensional hand scanning and dimension extraction method with dimension data. Ergonomics,Li Z. Chang C. C. Dempsey P. G. Ouyang L. Duan J. 51 51 11 November 2008, 1672-1692 - 74.
Liegeois A. 1977 Automatic supervisory control for the configuration and behavior of multibody mechanisms. , 7 (12),842 868 . - 75.
Lin Q. Burdick J. M. Rimon E. 2000 A stiffness-based quality measure for compliant grasps and fixtures. , 16(6),675 688 . - 76.
Liu G. Xu J. Li Z. 2004a On geometric algorithms for real-time grasping force optimization. Technology,12 6 843 859 . - 77.
Liu G. Xu J. Wang X. Li Z. 2004b On Quality Functions for Grasp Synthesis, Fixture Planning, and Coordinated Manipulation, IEEE Transactions on Automation Science and Engineering1 2 146 162 . - 78.
Mansour J. M. Rouvas C. Sarangapani J. 1994 Quantitative functional anatomy of finger muscles: Appliction to controlled grasp. , Eds. F. Schuind,177 188 , New York. Plenum Press. - 79.
Mason M. T. 2001 , The MIT Press, Cambridge, MA, USA. - 80.
Miller A. T. Allen P. K. 1999 Examples of 3D grasp quality computations, ,2 IEEE,1240 1246 . - 81.
Miller A. T. Knoop S. Christensen H. Allen P. K. 2003 Automatic grasp planning using shape primitives, Robotics and Automation, 2003. Proceedings. ICRA’03. IEEE International Conference on,2 IEEE,1824 1829 . - 82.
Miller A. Allen P. K. 2004 "Graspit!: A Versatile Simulator for Robotic Grasping". ,11 4 110 122 . - 83.
Minami A. An K. N. Cooney W. P. Linscheid R. L. 1985 Ligament stability of the MCP joint: A biomechanical study. 10A (2), 255-260. - 84.
Mirthich B. Canny J. 1994 Easily computable optimum grasps in 2D and 3D. In: ,739 747 . - 85.
Mishra B. Schwartz J. T. Sharir M. 1987 On the existence and synthesis of multifinger positive grips, 2(1-4): 541-558. - 86.
Mital A. Kilbom A. 1992 Design, selection and use of hand tools to alleviate trauma of the upper extremities: Part II- The scientific basis (knowledge base) for the guide, ,10 7 21 - 87.
Mommersteeg T. J. A. Blankevoort L. Huiskes R. Kooloos J. G. M. Kauer J. M. G. 1996 Characterization of the mechanical behavior of human knee ligaments: a numerical-experimental approach. J. Biomechanics 29 (2), 151-160. - 88.
Morales A. Sanz P. Del Poblil A. Fagg A. 2006 Vision-based three-finger grasp synthesis constrained by hand geometry. 54, 6, (June 2006),496 512 ),0921-8890 - 89.
Hand and arm injuries associated with repetitive manual work in industry: a review of disorders, risk factors and preventive measures. ,Muggleton J. M. Allen R. Chappell P. H. 1999 42 5 714- 739 - 90.
Napier J. 1956 The prehensile movements of the human hand, Surger38 4 902 913 . - 91.
Nguyen V. D. 1988 , Institute of Electrical and Electronics Engineers. - 92.
Parada J. E. Nava N. E. Ceccarelli M. 2008 A Methodology for the Design of Robotic Hands with Multiple Fingers,5 2 177 184 . - 93.
Park Y. C. Starr G. P. 1992 Grasp synthesis of polygonal objects using a three-fingered robotic hand. 11 (3),163 184 . - 94.
Virtual human hand. PhD dissertation. Universitat Politècnica de Catalunya. 2007.Peña-Pitarch ,E. - 95.
Pollard S. S. 2004 Closure and quality equivalence for efficient synthesis of grasps from examples. , 23 (6),595 614 . - 96.
Ponce J. Sullivan S. Sudsang A. Boissonat J. D. Merlet J. P. 1997 On computing for-finger equilibrium and force-closure grasps of polyhedral objects. , 16 (1),11 35 . - 97.
Muscle activation patterns during force generation of the index finger. Conf Proc IEEE Eng Med Biol Soc.Qiu D. Fischer H. C. Kamper D. G. 2009 3987 90 2009 - 98.
Rezzoug N. Gorce P. 2008 Prediction of fingers posture using artificial neural networks. . 41,2743 2749 . - 99.
Rhee T. Neumann U. Lewis J. P. 2006 Human Hand Modeling from Surface Anatomy. I3D ‘06 Proceedings of the 2006 symposium on Interactive 3D graphics and games, ACM New York - 100.
Roa Garzón. M. 2009 , Ph. d. thesis, Universidad Politécnica de Cataluña. - 101.
, Kasemsontitum B.; Rempel D. M.. A three-dimensional anthropometric solid model of the hand based on landmark measurements. Ergonomics, Vol. 51, No. 4, April 2008, 511-526 ,Rogers M. S. Barr A. B. - 102.
Biomechanical model for the determination of the forces acting on the finger pulley system. Journal of Biomechanics.Roloff I. Schöffl V. R. Vigouroux L. Quaine F. 5 39 915 23 2006 - 103.
Salisbury J. 1982 , Ph.d. thesis, Standford University. - 104.
Sancho-Bru J. L. 2000 “Model Biomecànic de la mà orientat al disseny d’eines manuals”, Ph.D. thesis, Universitat Jaume I, Castelló. - 105.
Sancho-Bru J. L. Perez-Gonzalez A. Vergara-Monedero M. Giurintano D. J. 2001 A 3-D dynamic model of human finger for studying free movements. , 34, 11, (November 2001),1491 1500 ),0021-9290 - 106.
Sancho-Bru J. L. Perez-Gonzalez A. Vergara M. Giurintan D. J. 2003a A 3D biomechanical model of the hand for power grip.125 78 83 . - 107.
Sancho-Bru J. L. Giurintano D. J. Pérez-González A. Vergara M. 2003b “Optimum tool handle diameter for a cylinder grip”, ., 16(4),337 342 . - 108.
Sancho-Bru J. L. Vergara M. Rodríguez-Cervantes P. J. Giurintano D. Pérez-González A. 2008 Scalability of the Muscular Action in a Parametric 3D Model of the Index Finger. 36, 1, (January 2008,102 107 ),0090-6964 - 109.
industrial wrist motions and incidence of hand/wrist cumulative trauma disorders. ,Schoenmarklin R. W. Marras W. S. Leurgans S. E. 199437 37 1449 1459 - 110.
Siciliano B. Khatib O. 2008 Springer Handbook of Robotics,15 Springer, Berlin, Heidelberg. - 111.
Smith E. M. Juvinall R. C. Bender L. F. Pearson J. R. 1964 Role of the finger flexors in rheumatoid deformities of the metacarpophalangeal joints. .,7 467 480 . - 112.
, 2001; P. Spielholz, B. Silverstein, M. Morgan, H. Checkoway And J. Kaufman. Comparison of self-report, video observation and direct measurement methods for upper extremity musculoskeletal disorder physical risk factors. Ergonomics, 2001, VOL. 44, NO. 6, 588- 613Spielholz et al . - 113.
Spoor C. W. Landsmeer J. M. F. 1976 Analysis of the zigzag movement of the human finger under influence of the extensor digitorum tendon and the deep flexor tendon. ,9 561 566 . - 114.
Spoor C. W. 1983 Balancing a force on the fingertip of a two-dimensional finger model without intrinsic muscles. ,16 497 504 . - 115.
Stansfield S. 1991 Robotic grasping of unknown objects: A knowledge-based approach,10 4 314 326 . - 116.
Storace A. Wolf B. 1979 Functional role of the finger tendons. Journal of Biomechanics,12 575 578 . - 117.
Storace A. Wolf B. 1982 Kinematic analysis of the role of the finger tendons. , 15, 5,391 393 ),0021-9290 - 118.
Thomas D. H. Long C. Landsmeer J. M. F. 1968 Biomechanical consideration of lumbricalis behaviour in the human finger. ,1 107 115 . - 119.
Tubiana R. 1981 ‘The hand’,1 W.B. Sanders Company, 1981. - 120.
Tubiana R. Thomine J. Mackin E. 1996 ‘Examination of the hand and wrist’, Second Edition, Martin Dunitz, 1996. - 121.
Valero-Cuevas F. J. Zajac F. E. Burgar C. G. 1998 Large index-fingertip forces are produced by subject-independent patterns of muscle excitation. , 31: 693:703. - 122.
Valero-Cuevas F. J. 2000 Predictive modulation of muscle coordinatin pattern magnitude scales fingertip force magnitude over the voluntary range. ,83 3 1469 1479 . - 123.
Valero-Cuevas F. J. JD Towles Hentz. V. R. 2000 Quantification of fingertip force reduction in the forefinger following simulated paralysis of extensor and intrinsic muscles. ,33 12 1601 1609 . - 124.
Valero-Cuevas F. J. 2005 An integrative approach to the biomechanical function and neuromuscular control of the fingers. , 38(4):673 684 . - 125.
A natural human hand model. Visual Comput (2008) 24: 31-44 ,van Nierop ,O.A. ,van der Helm ,A. ,Overbeeke ,K.J. Djajadiningrat ,T.J.P. - 126.
Vigouroux L. Quaine F. Labarre-Vila A. Moutet F. 2006 Estimation of finger muscle tendon tensions and pulley forces during specific sport-climbing grip techniques. , 39, 14,2583 2592 ),0021-9290 - 127.
Is the principle of minimization of secondary moments validated during various fingertip force production conditions? .Vigouroux L. Ferry M. Colloud F. Paclet F. Cahouet V. Quaine F. 2008 Jun;273 396 407 . - 128.
Weightman B. Amis A. A. 1982 Finger joint force predictions related to design of joint replacements.4 197 205 . - 129.
Wren D. Fisher R. 1995 Dextrous hand grasping strategies using preshapes and digit trajectories, IEEE International Conference on Systems, Man and Cybernetics,1 910 915 vol.1. - 130.
A practical biomechanical model of the index finger simulating the kinematics of the muscle/tendon excursions. Biomed Mater Eng. 2010;20(2):89-97. ,Wu ,J.Z. ,An ,K.N. ,Cutlip ,R.G. Dong ,R.G. - 131.
Xydas N. Kao I. 1999 Modeling of contact mechanics and friction limit surface for soft fingers with experimental results, , 18(9),947 950 . - 132.
Xydas N. Bhagavat M. Kao I. 2000 Study of soft-finger contact mechanics using finite elements analysis and experiments, Proceedings 2000 ICRA. Millennium Conference. IEEE International Conference on Robotics and Automation. Symposia Proceedings (Cat.00CH37065 (April):2179 2184 - 133.
A new digital human environment and assessment of vehicle interior design. Computer-Aided Design 39 (2007) 548-558 ,Yang ,J . ,Kim ,J.H. ,Abdel-Malek ,K. ,Marler ,T. Beck ,S. Kopp ,G.R. - 134.
Yoshikawa T. 1985 Manipulability of robotics mechanisms. , 4, 2,735 747 ) - 135.
Youm Y. Gillespie T. T. Flatt A. E. Sprague B. L. 1978 Kinematic investigation of normal MCP joint. , 11, 3,109 118 ),0021-9290 - 136.
Zajac F. E. 1989 Muscle and tendon: properties, models, scaling, and application to biomechanics and motor control. 17 (4),359 411 . - 137.
Zhu X. Ding H. Li H. 2001 A quantitative measure for multifingered grasps. In: ,213 219 .