1. Introduction
1.1. Articular cartilage
Articular cartilage is a specialized connective tissue that covers the ends of the bones in the diarthrodial joints. The thickness of human articular cartilage is typically between 1-6 mm. The main functions of articular cartilage are to dissipate and distribute contact stresses during joint loading, and to provide almost frictionless articulation in diarthrodial joints. In order to accomplish these demanding tasks, articular cartilage has unique mechanical properties. The tissue is a biphasic material with an anisotropic and nonlinear mechanical behaviour.
Articular cartilage is composed of two distinct phases. Fluid phase of the cartilage tissue consists of interstitial water and mobile ions. The water phase constitutes 68-85 % of the cartilage total weight and is an important determinant of the biomechanical properties of the tissue. Solid phase (or solid matrix) of the cartilage tissue consists mainly of collagen fibrils and negatively charged proteoglycans. The cell density is relatively small – in human adult tissue only ~2% of the total cartilage volume is occupied by the chondrocytes. Collagen molecules constitute 60-80% of the cartilage dry weight or approximately 10-20% of the wet weight. The collagen molecules assemble to form small fibrils and larger fibers that vary in organization and dimensions as a function of cartilage depth. The diameter of collagen fibers is approximately 20 nm in the superficial zone and 70-120 nm in the deep zone, and it varies between different collagen types. The collagen fibrils of the cartilage tissue consist mainly of type II collagen, although small amounts of other collagen types can be also found in cartilage, e.g. collagen type VI is common form in the vicinity of cells (pericellular matrix). In addition to the collagen fibrils, proteoglycan macromolecules constitute 20-40% of the cartilage dry weight or approximately 5-10% of the wet weight. The proteoglycan aggrecan is composed of a protein core and numerous glycosaminoglycan (GAG) chains attached to the core. Many aggrecan molecules are further bound to a single hyaluronan chain to form a proteoglycan aggregate.
The basic structure of the articular cartilage can be divided into four zones based on the arrangement of collagen fibril network (Benninghoff, 1925): 1) Superficial zone: here the chondrocytes are flattened and aligned parallel to the cartilage surface. The collagen fibrils are relatively thin and run parallel to each other. The proteoglycan content is at its lowest and the water content is at its highest. 2) Middle zone: here the collagen fibrils have a larger diameter and they are oriented randomly. The cell density and water content is lower and proteoglycan content is higher than in the superficial zone. 3) Deep zone: here the diameter of the collagen fibrils is at its largest, and the collagen fibrils are oriented perpendicular to the articular surface. The cell density and water content are at their lowest, the proteoglycan content at its highest but the collagen content is variable. 4) Calcified cartilage: this thin layer is located between the deep zone and the subchondral bone and it joins the cartilage tissue to the subchondral bone. Here the chondrocytes usually express a hypertrophic phenotype.
It is nowadays widely accepted that collagen fibrils are primarily responsible for the cartilage tensile stiffness and the dynamic compressive stiffness. In contrast, proteoglycans are primarily responsible for the equilibrium properties during compression, and fluid contributes to the dynamic and time-dependent properties of the tissue. For more comprehensive description of structure-function relationships of cartilage, the reader may consult e.g. the book by Mow et al. (2005).
1.2. Meniscus
Meniscus is a wedge-shaped fibrocartilaginous structure between femoral and tibial articular cartilage surfaces inside the knee joint capsule. The function of the meniscus is to bear and dissipate loads, provide stability to the knee joint, and protect articular cartilage from excessive loads by functioning as a shock absorber. Similarly as in articular cartilage, meniscus has complex mechanical properties in order to accomplish these tasks.
Meniscus has also biphasic composition. Such as in cartilage, fluid phase of the meniscus consists of interstitial water and mobile ions. The water phase constitutes 60-70% of the meniscus total weight and is similarly important determinant of the biomechanical properties of the tissue. Solid phase of the meniscus consists of highly organized collagen fibril network, negatively charged proteoglycans and meniscal cells (fibrochondrocytes). Collagen molecules constitute 15-25 % of the meniscus wet weight. In contrast with articular cartilage, the collagen fibrils of meniscus consist mainly of type I collagen, i.e. also found in skin and bone tissues, although smaller amounts of types II, III, V, and VI can be also found in meniscus (McDevitt&Webber, 1990). Furthermore, meniscus contains significantly less proteoglycan than articular cartilage, only 1-2% of the wet weight.
The basic structure of meniscus can be divided into different layers based on the arrangement of the collagen fibril network. Since the meniscus is located between femoral and tibial articular surfaces, it has two surface layers both in top and bottom. Below surface layers are intermediate layers and in the center of the meniscus is the central layer. At the femoral surface layer the collagen fibrils are relatively thick and run parallel to each other and the femoral surface. In contrast, at the tibial surface layer the collagen fibrils are oriented randomly. At inner layers, the arrangement of collagen fibrils is more variable. The central layer can be further divided into four zones in the axial plane: anterior and posterior parts of the central layer exhibit relatively parallelly organized collagen fibrils, middle part of the central layer exhibits irregular organization medially, wheras organization changes more regular and circular-shaped at the lateral side. For a more comprehensive and graphical description of structure and organization of collagen fibril network in the different layers of meniscus, the reader is recommended to consult the study of human meniscus structure by Cui&Min (2007).
Similarly as in cartilage, the collagen fibrils are mainly responsible for the tensile properties of meniscus and proteoglycans contribute strongly to the equilibrium response. Fluid has a significant role in carrying impact and dynamic loads. For more information of the general anatomical and functional properties of the meniscus, the reader may consult e.g. the review by Messner&Gao (1998).
1.3. Ligaments and tendons
Ligaments and tendons are soft tissues connecting bones to bones or bones to muscles, respectively. Their primary functions are to stabilize joints and transmit the loads, hold the joints together, guide the trajectory of bones, and control the joint motion area. Ligaments and tendons are also biphasic tissues having fluid and solid phases similarly as in articular cartilage and meniscus. Therefore, they also possess highly viscoelastic mechanical properties.
The fluid phase constitutes 60-70% of the total weight of ligaments and tendons. Solid phase consists of highly organized longitudinal collagen fibril network (over 15 % of the wet weight), elastin network, and proteoglycans. Similarly than in meniscus, the collagen fibrils of ligaments and tendons consist mainly of type I collagen. Since ligaments and tendons have so tightly packed and organized long collagen fibril network they have extremely high tensile strength and nonlinear stress-strain behavior.
For more information of the anatomical and functional properties of the ligaments and tendons, the reader may consult e.g. the book chapter by Woo et al. (2005).
Collagen (wet weight) | Proteoglycan (wet weight) | Fluid (wet weight) | Young’s modulus | |
Articular cartilage | 10-20% (type II) | 5-10% | 68-85% | ~0.5 MPa (compression) |
Meniscus | 15-25% (type I) | 1-2% | 60-70% | ~0.1 MPa (compression) |
Ligament | 20-30% (type I) | less than in cartilage | 60-70% | "/>100 MPa (tension) |
Tendon | more than in ligament (type I) | less than in ligament | 60-70% | "/>1000 MPa (tension) |
Table 1.
Main compositional parameters and elastic properties of articular cartilage, meniscus, ligaments and tendons.
2. Experimental mechanical characterization of skeletal soft tissues
2.1. Introduction
When skeletal soft tissues are mechanically tested, one can apply either force or deformation to it and then follow the other parameter. For example, constant or changing force may be applied to a tissue and consequent change in the deformation is followed. Similarly, the change in force can be followed when constant or changing deformation is applied. Important parameter to describe the behavior of tissues under loading is strain
where
Second important parameter in biomechanical testing is stress
where
When both stress
When the compressive or tensile stress is applied to, say, excised soft tissue sample, consequent strain occurs in the direction of the loading. However, when the strain occurs in one direction in a three-dimensional soft tissue sample, there is always corresponding strain in the perpendicular direction. For example, when a soft tissue sample is stretched in one direction it typically simultaneously compresses in perpendicular direction changing its shape. The change of shape is the third important parameter in biomechanical testing. It is quantified with the parameter called the Poisson‘s ratio
where
It is also possible to apply load or deformation to a soft tissue sample parallel to the surface. This requires fixed contact between the tester and the surface of the sample. Then, so called shear strain
where
where
2.2. Mechanical testing geometries
Mechanical testing geometries for soft tissues can be divided into compression, tension, bending and torsion. We will now consider only compression and tension since they are the most relevant geometries for skeletal soft tissues.
Compression testing is widely used especially for determination of mechanical properties of articular cartilage and meniscus. This is a relevant choice since also in vivo, e.g. during normal walking cycle, articular cartilage and meniscus experiences external compressive forces. When the tissue is mechanically tested in compression, three different measurement configurations can be used: unconfined compression, confined compression and indentation. In unconfined compression, a soft tissue sample is compressed between two smooth metallic plates to a predefined stress or strain. This geometry allows interstitial fluid flow out of the tissue only in the lateral direction (Fig. 1). In confined compression, a soft tissue sample is placed in a sealed chamber and, subsequently, compressed with a porous filter (Fig. 1). In this geometry the interstitial fluid can only flow axially through the tissue surface into the filter. In indentation geometry, a soft tissue is compressed with a cylindrical, typically plane-ended or spherical-ended indenter (Fig. 1). In this geometry, fluid flow outside the indenter-tissue contact point is possible in both the lateral and axial directions. It should be emphasized that the indentation is the only compressive geometry which is not limited into the laboratory use. Since indentation testing does not require a preparation of separate tissue samples it can be also performed in vivo. For example, stiffness of femoral articular cartilage has been measured during arthroscopy in vivo (Vasara et al., 2005).
Tensile testing is widely used especially for determination of mechanical properties of ligaments and tendons, while it is less used for the characterization of cartilage and meniscus properties. Again, this is a relevant choice for these tissues since they exhibit mainly tensile stresses in vivo. In tensile testing, a soft tissue sample is fixed with two ends, e.g. by using metallic clamps, and the sample is then streched to a predefined stress or strain.

Figure 1.
Unconfined, confined and indentation loading geometries for testing of mechanical properties of articular cartilage.
2.3. Destructive and nondestructive testing protocols
In all experimental mechanical testing geometries it is possible to conduct both destructive and non-destructive testing. In non-destructive protocol tissue is tested with small strains or loads and all the changes induced to the tissue are reversible. In contrast, destructive protocol involves larger strains or loads inducing non-reversible changes to a tissue.
Most common non-destructive testing protocols are called creep and stress-relaxation. These tests can be conducted both in compression and tension geometries. In creep test, constant compressive or tensile stress is applied to a tissue and corresponding strain is followed as a function of time (Fig. 2). In stress-relaxation test, predefined compressive or tensile strain is applied and corresponding stress is followed as a function of time (Fig. 2). All biphasic and viscoelastic soft tissues exhibit first the relaxation phase in both testing protocols, and finally when the tissue reaches its equilibrium state, no fluid flow or pressure gradients exist. Consequently, after the relaxation phase, strain (in creep test) or stress (in stress-relaxation test) stabilizes at the constant level, and then the entire load is carried by the solid matrix of a tissue.
Destructive testing is typically conducted for skeletal soft tissues only in tension geometry. Then it is common to follow the tissue mechanical behaviour from the stress-strain curve. At the beginning phase of tension test of skeletal soft tissue, one can observe so called toe region (Fig. 3). In this region, the relation between stress and strain is nonlinear and the slope is increasing with increased loading. The reason for the increasing slope is the straightening of the wavy-like collagen fibrils. After the collagen fibrils are completely straightened begins the elastic region (Fig. 3). In this region, the stress and strain are linearly related and the slope of the curve is called the Young’s modulus of tissue. In the elastic range, all changes of a tissue are still reversible, i.e. if the stress is removed tissue returns to the original strain. All non-destructive tests, such as creep and stress-relaxation tests mentioned above, should be conducted in this elastic region. It should be also noted that in human skeletal soft tissues the loading rate affects the slope of the elastic range, i.e. higher loading rate results to steeper slope and higher Young’s modulus value.
When the stress is further increased from the elastic region, the slope of the curve changes and the plastic region begins. This is called the yield point (Fig. 3). After the yield point tissue begins to experience destructive changes, e.g. microfractures in the collagen fibril network. In the plastic region irreversible changes have occurred in a tissue and it does not return to the original strain although the stress would be completely removed. The yield point is one typical parameter reported for soft tissues under destructive testing.
After the plastic region, the sudden failure of the tissue occurs and stress disappears (Fig. 3). The location of the breakdown is called the failure point, which is one typical parameter reported for soft tissues under destructive tensile testing.

Figure 2.
Stress-relaxation (left) and creep (right) testing protocols.

Figure 3.
Typical stress-strain curve for destructive tensile testing of skeletal soft tissues. Collagen fibril straightening and failure, related to different regions of the stress-strain curve, are also schematically shown.
3. Biomechanical modeling of skeletal soft tissues
3.1. Introduction
In this section, we will present the development of computational models applied for the characterization of biomechanical properties of cartilage, meniscus, ligaments and tendons. We will start from traditional linearly elastic models that can be applied for the characterization of static or dynamic properties of tissues by a simple Hookean relation. As the linear elastic model is only applicable for small strains, we will also introduce hyperelastic models that can be applied for nonlinear problems in larger strains.
Second, we will show traditional solid viscoelastic models, i.e. Maxwell, Voigt and Kelvin models. We will show the basic equations of these models. Then, we will take fluid into account in the model and present a biphasic, poroelastic model. We will present biphasic models with isotropic and anisotropic solid matrixes, improving the prediction of experimentally found mechanical behavior of fluid-saturated soft tissues.
Finally, we will present the fibril reinforced biphasic model of cartilage. In this model, the solid matrix is divided into fibrillar and non-fibrillar parts. We will also present different forms of nonlinearities formulated especially for the collagen fibers and the swelling properties due to the fixed charge density of proteoglycans. At the end of the section, we will summarize the application of the presented constitutive models for cartilage, menisci, ligaments and tendons.
3.2. Linear elastic model
The most traditional and simplest mechanical model for skeletal soft tissues is Hooke’s linear elastic model for solid materials. This model assumes the linear relation between stress and strain, corresponding to a spring fixed from one end and compressed or strecthed from the other. Hooke’s model can be presented as follows:
where
Hooke’s law can be further generalized for an anisotropic elastic material, when it can be expressed as a matrix form:
where
Even though one could determine all required stiffness components for an anisotropic elastic material, the mechanical behaviour of skeletal soft tissues still cannot be described by this linear model. In general, the linear elastic model can be applied for skeletal soft tissues when strains are small and the stress-strain relationship can be assumed linear. However, many soft tissues experience large strains in vivo. Furthermore, time-dependent behaviour (due to viscoelasticity) and different mechanical responses in compression and tension, both typical to skeletal soft tissues, cannot be described with this simple model. Therefore, more sophisticated models are needed for the mechanical characterization of skeletal soft tissues.
3.3. Hyperelastic model
Many biological tissues experience large deformations and then the stress-strain relationship becomes nonlinear. These materials are called hyperelastic materials. There are several hyperelastic material models developed, e.g. Neo-Hookean, Arruda-Boyce, Mooney-Rivlin, Ogden models. We will present here one of these models (Neo-Hookean model) that has been typically applied for many biological soft tissues.
The Neo-Hookean material model uses a general strain energy potential for finite strains:
where C1 and D1 are material parameters,
where
Where
3.4. Viscoelastic models
There are three typical viscoelastic solid materials that have been applied for biological soft tissues; Maxwell, Voigt and Kelvin (Standard linear solid) (Fig. 4). In contrast to the elastic or hyperelastic materials, these models have a time-dependent component that enables the modelling of creep, stress-relaxation and hysteresis.
The solid voscoelastic models are composed of elastic and viscous components. The elastic component is that shown in eq. 3.1, while the viscous component (dashpot) is velocity dependent as:
where
In the Voigt model, the forces of the spring and dashpot elements are different, but their deformation is the same. Thus, the total force is the sum of forces acting on the spring and dashpot:
In the Kelvin model, the combination of two springs and one dashpot complicates the equation of motion. The same principles as with the Maxwell and Voigt models can be applied, i.e. the elements that are side by side, undergo the same deformation but different force, while those that are arranged consecutively, experience the same force but different deformation. Subsequently, it can be proven that the equation of motion becomes:
where
There are several textbooks that derive creep and stress-relaxation equations of the aforementioned viscoelastic models. See for instance Fung (2004).

Figure 4.
Solid viscoelastic models: a) Maxwell, b) Voigt, c) Kelvin. F=force, µ=spring constant,=damping coefficient, x=distance.
3.5. Biphasic, poroelastic model
The biphasic model is the most traditional model of articular cartilage and other fluid-saturated tissue which takes the interstitial fluid movement into account (Mow et al., 1980). In the biphasic theory, the solid matrix and fluid are assumed to be intrinsically incompressible and nondissipative. The only dissipative factor is the fluid flow in the tissue. The constitutive equations, i.e, the stress-strain relations for the solid, fluid and entire tissue are given by:
where
For the biphasic material with linearly elastic Hookean solid matrix (see eqs. 3.1 and 3.2), the effective solid stress can be written as follows:
where
With both solid and fluid phases considered intrinsically incompressible and homogenous, the balance of mass (continuity equation) is given by:
where
where permeability k is related to the diffusive drag coefficient K by:
The permeability k can be defined to be dependent on the porosity and void ratio, i.e. ratio of fluid to solid content, according to the following equation:
where
where z is the tissue depth (0: cartilage surface, 1:cartilage-bone interface).
3.5.1. Isotropic model
The elastic parameters of the biphasic poroelastic tissue can be obtained from the equation 3.14. The simplest form of linear elasticity is the isotropic case. The stress-strain relationship becomes:
Subsequently, the isotropic biphasic or poroelastic model consists of three material parameters: elastic parameters (Young’s modulus (E), Poisson’s ratio (v)) and permeability (k, eq. 3.19)).
The biphasic isotropic material is equivalent to the elastic isotropic material at equilibrium and under dynamic loading. In these representations, it is assumed that at equilibrium all fluid flow has ceased and that the instantaneous response (t → 0) of the biphasic tissue corresponds to that of an incompressible elastic material (ν = 0.5). These elastic isotropic models are useful if one wishes to obtain simple material parameters for the tissue. However, a more detailed description of the complex mechanical properties of skeletal soft tissues can only be obtained by using more sophisticated models.
3.5.2. Transversely isotropic model
In the transversely isotropic material, the mechanical parameters depend on the three mutually orthogonal directions. However, the properties are considered isotropic in the x-y plane. Then, the stiffness matrix relates the stress and strain tensors as follows:
where
The total number of transversely isotropic biphasic poroelastic parameters can now be written in terms of the Young’s modulus and Poisson’s ratio in the transverse plane, i.e. parallel to the articular surface (
Under an instantaneous loading (t → 0), when fluid is entrapped in the tissue, the transversely isotropic biphasic or poroelastic material behaves like an incompressible elastic material (Garcia et al., 2000; Korhonen et al., 2002b), similarly as in the case of the isotropic model. The elastic parameters are then:
Similarly at equilibrium, when the fluid flow has ceased and only the solid matrix resists the compression, the material can be assumed to be elastic with the five independent material parameters in eq. 3.23.
3.5.3. Fibril reinforced model
In the fibril reinforced biphasic model, the fibril network (collagen network), in addition to the isotropic biphasic matrix, contributes to the mechanical response of tissues under loading (Korhonen et al. 2003). Thus, the total stress becomes:
where
where
The collagen fibril stresses (
where
The fibrillar part has also been modeled with primary and secondary fibrils (Wilson et al., 2004). The primary fibrils represent the collagens detected with polarized light microscopy (Arokoski et al., 1996; Korhonen et al., 2002b), which cause a depth-dependent tensile modulus for the tissue. The fibrils are oriented vertically in the deep zone, curve in the middle zone, and reach a parallel orientation with the articular surface in the superficial zone (Benninghoff, 1925). Two parameters are needed to describe the fibril orientation: thickness of the superficial zone (dvec) and bending radius of the collagen fibrils in the middle zone (rvec). The secondary fibrils mimic the less organized collagen network which are observed in scanning electron microscopy (Kaab et al., 2003). The stresses for primary and secondary fibrils can be formulated as:
where
3.5.4. Other models of skeletal soft tissues
There are also other models of biological soft tissues than those presented above. The conewise linear elastic model is able to characterize compression-tension nonlinearity of the tissues (Soltz&Ateshian, 2000). The poroviscoelastic model includes both fluid flow dependent and fluid flow independent viscoelasticities (DiSilvestro&Suh, 2001). The triphasic model includes ion flow (Lai et al., 1991) and it is equivalent to the biphasic swelling model at equilibrium (Wilson et al., 2005a). In the biphasic fibril reinforced swelling model, after inclusion of osmotic swelling and chemical expansion, the total stress becomes:
where
Other anisotropic and nonlinear representation have also been presented for biological soft tissues. Specifically the collagen fibrils and their nonlinear stress-strain tensile behavior has been presented as follows:
where Pf is the first Piola-Kirchhoff fibril stress, εf is the total fibril strain, εe is the strain of the spring 1 (Fig. 3c), and E1, E2, k1 and k2 are constants (Wilson et al., 2006; Julkunen et al., 2008). Tensile stress-stretch relationship for collagen fibrils has also been presented in the following form
where
In these equations, F2 is the strain energy function for the collagen fibers, usually in conjunction with the hyperelastic model, such as Neo-Hookean (eq. 3.3), is fiber stretch, * is the stretch where collagen fibers are straightened, and
3.6. Models applied for skeletal soft tissues
Articular cartilage has been modelled using almost all the above mentioned models (Mow et al., 1980; Lai et al., 1991; Li et al., 1999; Garcia et al., 2000; Guilak&Mow, 2000; Soltz&Ateshian, 2000; DiSilvestro&Suh, 2001; Korhonen et al., 2003; Laasanen et al., 2003; Wilson et al., 2004; Julkunen et al., 2007). The choice of the material model has been mainly based on the study purpose and loading protocol. Recently, however, the fibril reinforced material description has been applied by many researchers and it is probably the most realistic approach for cartilage (Li et al., 1999; Li et al., 2000; Korhonen et al., 2003; Wilson et al., 2004; Wilson et al., 2005b; Julkunen et al., 2007; Korhonen et al., 2008; Julkunen et al., 2009). It should also be noted that in articular cartilage negative fixed charges create tissue swelling pressure and is very important for the mechanical behaviour of the tissue. Thus, tissue swelling model or triphasic approaches are important phenomena. Meniscus, ligaments and tendons have only a small amount of fixed charges and swelling mechanisms have thus been neglected in the models.
Meniscus has been typically modelled as isotropic or transversely isotropic material (Spilker et al., 1992; Meakin et al., 2003; Sweigart et al., 2004; Guess et al., 2010). Poroelastic properties have also been included in meniscus models. Typical models for ligaments and tendons have been transversely isotropic nonlinear with hyperelastic behaviour (Pena et al., 2006; Zhang et al., 2008). Also viscoelastic solid models (Thornton et al., 1997) and poroelastic models have been applied for ligaments (Atkinson et al., 1997). However, the fluid-flow dependent viscoeasticity may not be that important in ligaments and tendons because they experience mainly tensile forces under physiological loading and it has been suggested that fluid has only a minor role in contributing to soft tissue response in tension (Li et al., 2005). Furthermore, viscoelastic models with anisotropic nonlinear stress-strain behaviour have been developed to capture the strain rate dependent nonlinearity of ligaments and tendons (Pioletti et al., 1998; Limbert&Middleton, 2006).
3.7 Optimization of material parameters
The optimization of material parameters of the model can be done by typically minimizing the mean squared error (MSE), root mean squared error (RMSE) or mean absolute error (MAE) between the simulated and experimental force curves (Fig. 5). This can be done for instance using a multidimensional unconstrained nonlinear minimization routine (fminsearch) available in Matlab (Mathworks Inc., Natick, MA, USA). The optimization should be first tested with different initial values of the material parameters, and the optimized parameter values should be always the same, independent on the initial guess. Then one of the equations for MSE, RMSE and MAE,
where

Figure 5.
A typical stress-relaxation measurement of articular cartilage and corresponding optimized model fit using a fibril reinforced poroviscoelastic model.