Open access peer-reviewed chapter

Multifunctional Bismuth-Based Materials for Heavy Metal Detection and Antibiosis

Written By

Yiyan Song and Jin Chen

Submitted: 17 October 2017 Reviewed: 22 February 2018 Published: 20 June 2018

DOI: 10.5772/intechopen.75809

From the Edited Volume

Bismuth - Advanced Applications and Defects Characterization

Edited by Ying Zhou, Fan Dong and Shengming Jin

Chapter metrics overview

1,485 Chapter Downloads

View Full Metrics

Abstract

The increasing complexity of environmental contamination has boosted the search of multifunctional nanomaterials that are produced in a green and economical manner. The bismuth-based materials have been long regarded as safe materials used in cosmetics as well as biomedical aspects. Particularly, as one of the most important bismuth oxyhalides, bismuth oxychloride (BiOCl), due to its intrinsic properties including high surface area, superior photocatalytic/electrochemical performance, and good biocompatibility, possesses enormous potential for environmental applications. In this chapter, we mainly introduced bismuth-based materials as typified by BiOCl as ecofriendly multifunctional materials for the purposes of heavy metal detection as well as antibiosis.

Keywords

  • bismuth
  • heavy metal detection
  • electrochemical stripping analysis
  • antibiosis

1. Introduction

As one of the heavy metal elements in the periodic table, bismuth has attracted considerable interests for industrial and biotechnological applications. Cosmetic and pharmaceutical uses of bismuth compounds can be dated back over two centuries ago. Bismuth materials including metal bismuth as well as its compounds have been long regarded as green materials due to their eco-friendliness. Owing to their biocompatibility, extensive research of bismuth has been conducted in diverse fields. For example, the layered structure of bismuth oxychloride (BiOCl) enabling it to give pearl-like coloring was used in cosmetics. Electrodes decorated with bismuth-based materials such as Bi(NO3)3 and Bi2O3 have been used for the electrochemical stripping analysis of heavy metals as an alternative method to replace toxic mercury-based ones [1, 2, 3]. In particular, owing to its large surface area, extraordinary electronic transport properties and high electrocatalytic activities, BiOCl has been extensively studied especially for industrial purpose such as photocatalytic/electrochemical materials [4, 5]. Notably, it was reported that bismuth subsalicylate (BSS), the active ingredient of an antacid drug with the trademark of Pepto-Bismol that was approved for sale over a century in North America, is hydrolyzed into BiOCl in the stomach [6, 7, 8, 9], suggesting its organism safety for clinical practice. Meanwhile, because of their therapeutic efficacy to deal with gastrointestinal disorders and microbial infections, bismuth-based conjugates such as colloidal bismuth subcitrate have been explored in the pharmaceutical industry.

Advertisement

2. The morphology of bismuth-based materials

Despite the extraordinary photo/electro-chemical properties, the layer structure of bismuth-related material typified by BiOCl may limit its practical applications. Therefore, in an effort to obtain BiOCl-based material of defined morphology, mesoporous silica materials including Korea Advanced Institute of Science and Technology-6 (KIT-6) have been tested as structural support to produce BiOCl-KIT-6 composites. As shown in Figure 1A, scanning electron microscopic image (SEM) of BiOCl has revealed its layer assembly, which was composed of microspheres with a diameter of about 3 μm. By comparison, BiOCl-KIT-6 composites exhibited a relatively large form distributing in a size range of tens of micrometers (Figure 1B) with a raspberry-like display of bunched balls. It was found that both BiOCl and BiOCl-KIT-6 composites were composed of nanoplates of several nanometers in thickness, aligning radically and tightly to form hierarchical microspheres. X-ray diffraction (XRD) analysis was performed to study the crystallographic structure of the BiOCl-KIT-6 composites. As shown in Figure 2, the well-crystallized phase of BiOCl-KIT-6 composite agreed well with that of the tetragonal BiOCl (JCPDS Card No.06-0249). The peaks located at 24.0°, 34.8°, and 36.5° correspond to (002), (012), and (003) crystalline planes of the BiOCl structure, respectively, representing the characteristics of lamellar structures. The crystallite size (average size of the coherent scattering region) for the BiOCl component was found to be 17.8 nm, calculated according to the Scherrer formula [10].

Figure 1.

SEM images of (A) BiOCl (Adapted from Ref. [10]) and (B) BiOCl-KIT-6.

Figure 2.

XRD pattern of BiOCl-KIT-6 composite (adapted from Ref. [10]).

Advertisement

3. Bismuth-based sensor for the determination of heavy metals

The method to achieve bismuth-based electrode mainly included in situ plating and ex situ plating. The in situ plating involves the addition of Bi3+ into the sample solution. The bismuth film was formed on the surface of the electrode through the deposition during analyzing process. This method is limited as the assay pH of the sample solution has to be kept acidic. The ex situ plating includes plating the bismuth film on the electrode prior to the analysis of the sample solution. As such, preforming bismuth film on the electrode surface is not influenced by the assay conditions, ex situ method is relatively versatile for the real analysis though additional cautions and preparations are needed compared with in situ one. It is worth mentioning that bismuth-based electrode prepared by ex situ method can be reused. After the measurement, the bismuth-based electrode can be reactivated by holding the electrode at an adequate potential, which is more negative than the oxidation potential of bismuth while more positive than the oxidation stripping potential of analyzed metal ions. Therefore, after the reactivation, the bismuth-based electrode can be regenerated without any possible interference of deposited metals.

The application of bismuth-based electrode for heavy metal detection dated back to 2000 when Wang and coauthors tried to plate thin bismuth films on the carbon electrode as an alternative to mercury-based electrode [1]. The main advantage of bismuth-based material modified electrode is its nontoxicity to the environment as well as the biosafety for the operational personnel. Meanwhile, the bismuth-based sensors provide detection sensitivity and accuracy comparable to that of mercury-based ones [11], which are attractive for practical applications. Recently, bismuth-based sensors, exhibiting improved separation ability of intermetallic compounds, compared with mercury-based ones, have been used to evaluate heavy metals such as Cd2+ and Pb2+. These toxic heavy metals originating from severe environmental conditions including mining area, smelting works, and sewage plant [12] are harmful for the public health.

Nowadays, electrochemical methods owing to their portability, ultrasensitivity, readiness, and low cost have become useful and efficient for the trace determination of heavy metals [13, 14, 15, 16, 17]. Among them, anodic stripping voltammetry (ASV), which involves an effective preconcentration step to form metals on the electrode surface by reducing metal ions in the assay solution, followed by a sensitive stripping analysis where metals were reoxidized contributing to a remarkable signal-to-noise ratio, has been intensively employed in this aspect during the past decade (Figure 3). The amplified stripping signal resulting from bismuth-based electrodes reflects the ability of bismuth to form “fused” multicomponent alloys with targeted heavy metals [18]. Bismuth-based sensors thus hold potentials for the assays of heavy metal with applications ranging from continuous remote sensing to disposable chips. Since the bismuth-based electrode was applied for the determination of heavy metals in 2000 [1], many reports related to various bismuth-based material modified electrodes have been devoted to this area. In 2008, Xu and coworkers used a Nafion-coated bismuth electrode to achieve the simultaneous determination of three heavy metals including Pb2+, Cd2+, and Zn2+ in vegetables using differential pulse anodic stripping voltammetry [19]. In 2014, Sosa and coworkers analyzed Cd2+ and Pb2+ in groundwater based on sputtered bismuth screen-printed electrode [20]. In 2015, Cerovac and coworkers used the bismuth-oxychloride particle-multiwalled carbon nanotube composite-modified glassy carbon electrode to detect trace-level lead and cadmium in sediment pore water [21]. And it is also readily possible to evaluate the heavy metal amounts of human blood sample. For example, Song and coworkers determined Cd2+ in blood samples based on BiOCl-KIT-6 modified glassy carbon electrode [11]. During the past decade, many studies have introduced a number of trace heavy metal detection methods based on bismuth-based electrode. Some typical bismuth-based sensors as well as the resulting analytical performance are summarized in Table 1.

Figure 3.

A schematic diagram of measurement of heavy metal ions using anodic stripping voltammetry.

SensorMethodDeposit. potent. (v)Deposit.
time (s)
Linear range (μg/L)LOD(μg/L)Ref.
PbCdPbCd
Bi-CNT SPESWASV−1.43002–1002–1001.30.7[27]
NCBFEDPASV−1.41804–364–360.170.17[19]
Bi/GCESWASV−1.26005–605–600.80.4[28]
BispSPEDPASV−1.33600.5–200.3–120.160.10[20]
BiOCl/MWCNT-GCESWASV−1.21205–505–500.571.2[21]
BiOCl-KIT-6/GCESWASV−1.31200.2–3000.2–3000.050.06[12]

Table 1.

Bismuth-based electrodes for determination of Pb (II) and Cd (II) using anodic stripping voltammetry.

Bi-CNT SPE, bismuth-modified carbon nanotube modified screen-printed electrode; NCBFE, Nafion-coated bismuth film electrode; Bi/GCE: bismuth nanoparticles modified GCE; BispSPE, sputtered bismuth screen-printed electrode; MWCNT, multiwalled carbon nanotube; SWASV, square wave anodic stripping voltammetry; DPASV, differential pulse anodic stripping voltammetry.


Nevertheless, in comparison with mercury-based electrode, bismuth-based one often works well in a relatively narrow potential window, particularly being in a more negative anodic range due to the fact that bismuth is more easily oxidized than mercury. Meanwhile, the cathodic limit of bismuth-based electrode posed by hydrogen reduction is close to that of mercury-based one. Therefore, the accessible potential window of bismuth-based electrode is narrower than that made of mercury. Additionally, it was found that the potential window of bismuth-based electrode was strongly affected by the pH values of the sample solution. The relationship of operational potential windows of bismuth-based electrode and assay pH is shown in Table 2 [22]. Moreover, it was observed that the constructed BiOCl-KIT-6/GCE possessed a wide potential window ranging from −1.22 to −0.25 V versus SCE by recording the CV spectra of electrode in 0.1 M acetate buffer (pH 4.5) (Figure 4). The wide potential window of BiOCl-KIT-6/GCE may permit the simultaneous determination of Zn2+ (stripped at −1.15 V), Pb2+ (stripped at −0.58 V) and Cd2+ (stripped at −0.83 V). It should be noted that the stripping analysis of heavy metals is limited if oxidation potentials of analyzed metals are close to or more positive than that of bismuth such as Cu, Sn, and Sb.

MediumpHAnodic limit (V)Cathodic limit (V)Potential window (V)
0.1 M HClO41.00−0.05−1.051.10
0.2 M HAc-NaAc4.24−0.25−1.251.00
0.1 M NaOH12.17−0.55−1.551.00

Table 2.

Operational potential of bismuth-based materials plated on carbon-paste electrodes at different pH (Data taken from Ref. [22]).

Figure 4.

Cyclic voltammetry (CV) analysis of BiOCl-KIT-6/GCE in acetate buffer solution (0.1 M, pH 4.5) (adapted from Ref. [10]).

In the aspect of heavy metal measurement, many earlier studies have focused on the design of bismuth-based sensors as well as the detection principle. However, their applications to environmental, food, and clinical samples have just started. For example, by the use of anodic stripping voltammetry, cadmium and lead at trace levels in environmental samples [23, 24], food products [25, 26] and biological fluids [11] have been determined. Using square-wave anodic stripping voltammetry (SWASV), the constructed BiOCl-KIT-6/GCE applied to the determination of cadmium-spiked human blood samples resulted in a calibration curve of Cd2+ with 2 linear ranges from 0.5 to 10 and from 10 to 300 μg/L (Figure 5), respectively, and a detection limit of 65 ng/L. As shown in Figure 6, a good agreement between the detection methods of SWASV and inductively coupled plasma mass spectrometry (ICP-MS) was observed [11]. Moreover, the BiOCl-KIT-6/GCE could be repeatedly used for at least 30 continuous times in one day and at least 10 continuous days with a marginal reduction of stripping peak current of 6.8 and 3.6%, respectively.

Figure 5.

(A) Square-wave anodic stripping voltammetric (SWASV) responses of peak current on the concentration of Cd2+ using BiOCl-KIT-6/GCE in acetate buffer solution (pH 4.5) at the deposition potential of −1.3 V and deposition time of 120 s. (B) Calibration curves of Cd2+ over a concentration range of 0.5–300 μg/L (adapted from Ref. [10]).

Figure 6.

The determination results of blood cadmium concentration by anodic stripping voltammetry (ASV) using BiOCl-KIT-6/GCE in comparison with ICP-MS assay (adapted from Ref. [11]).

Despite considerable progress achieved during the past decade, most of the earlier studies have mainly explored various bismuth-based materials towards the sensor fabrication. Therefore, practical concerns still remain to be addressed to fulfill the demands of environmental protection and so on. Further works to utilize the constructed sensor under harsh operational conditions and to simply the assay procedures are still needed in the future.

Advertisement

4. Bismuth-based materials for biomedical use

Bismuth is a heavy metal element located close to lead and tin elements in the periodic table of elements, and thus shares similar physicochemical properties with these elements. But different from lead and tin, bismuth is usually regarded as nontoxic and biologically safe. Therefore, bismuth as well as its derivate has been extensively explored in biomedical applications. For example, bismuth salts are valuable for synthesis of various bismuth-based complexes as the active ingredients for pharmaceutical uses. The first report on bismuth-containing medicine in 1786 revealed its efficacy in the treatment of dyspepsia. And since then, there is a growing number of bismuth complexes which were explored to deal with gastrointestinal disorders and microbial infections including syphilis, diarrhea, gastritis, and colitis, which point out desirable therapeutic effects yet low toxicity after the intake of drug molecules.

In the laboratory, the antimicrobial activities of bismuth-based materials can be evaluated by recording the growth curve of model bacteria such as Gram-positive Staphylococcus aureus and Gram-negative Escherichia coli in the presence of materials. As shown in Figure 7, the growth curves of S. aureus cells in the presence and absence of 20 μg/mL BiOCl-KIT-6 were observed. There was an apparent decrease in the growth curve when adding BiOCl-KIT-6 composite, suggesting that BiOCl-KIT-6 composite can be used as an antimicrobial agent against S. aureus. The underlying antimicrobial mechanism of bismuth-based materials can be further studied using radical-sensitive fluorescent dyes. The generation of free radicals has been considered as one of the causes of metal particle-induced cytotoxicity in bacteria [29]. Therefore, the cytotoxicity of BiOCl-KIT-6 composite may be linked to the formation of reactive oxygen species (ROS). Cellular accumulation of ROS can be detected using the fluorogenic dye DCFDA based on the oxidation of the non-fluorescent 2’,7’-dichlorodihydrofluorescein (DCFH) that reacts with H2O2, O2−, and ONOO into the green fluorescent dichlorofluorescein (DCF), which provides a general indication of ROS levels. As shown in Figure 8, S. aureus incubated with BiOCl-KIT-6 showed more green fluorescence compared with the untreated group (negative control), indicating the formation of ROS detrimental to the cell growth (Figure 7).

Figure 7.

Growth curves of S. aureus cultured in LB media containing 20 μg/mL BiOCl-KIT-6 composite suspension. Each data point is the average of three independent assays with standard error of the mean (adapted from Ref. [12]).

Figure 8.

In the presence and absence of BiOCl-KIT-6 suspension (200 μg/mL), S. aureus were stained with 10 μM ROS-dependent fluorescent probe (DCFDA) in the dark field (left) and bright field (right) under a fluorescence microscope (adapted from Ref. [12]).

H. pylori has been considered to play a role in the development of chronic gastritis, peptic ulcers, and even gastric cancer, and thus bismuth-based drugs are usually prescribed once H. pylori infection is diagnosed. Based on the clinical survey, H. pylori is susceptible to several antibiotics such as clarithromycin, amoxicillin, metronidazole, tetracycline, and rifabutin and exhibits resistance to many other antibiotics like bacitracin, vancomycin, trimethoprim, polymyxins, and nalidixic acid. Therefore, it remains challenging to cure H. pylori infection. In an effort to minimize the antibiotic resistance, bismuth complex has been utilized to treat gastrointestinal disorders and ulcers with pronounced inhibition activity against H. pylori [9]. Some commercial medicines with bismuth-containing ingredients are summarized in Table 3. Basically, the bismuth-containing pharmaceuticals have two functions—antiulcer and antibacterial. The antiulcer activity of bismuth complex is explained by the precipitation of bismuth around the ulcer point to form a glycoprotein-bismuth complex as a protective coating promoting the healing of the lesion. The underlying molecular mechanisms of bismuth compounds to deal with H. pylori are not fully elucidated. Some preliminary reports have indicated that the biological targets of bismuth compounds are closely related to several H. pylori-related proteins [8].

Bismuth complexName of pharmaceuticals
Bismuth potassium citrateLivzon Dele, Bielomatik
Bismuth subcitrateDe-nol, Tripotassium dicitratobismuthate
Bismuth citrateRanitidine
Colloidal bismuth pectinColloidal bismuth pectin capsules
Bismuth aluminateDebitai, Compound bismuth aluminate tablets

Table 3.

Bismuth-containing drugs for the treatment of gastrointestinal diseases.

Over the years, to produce a number of bismuth complexes for biomedical uses, the synthesis methods have also historically evolved, which mainly include hydrothermal, solvothermal, and microwave synthesis. Hydrothermal synthesis is a method to synthesize single crystals from high temperature aqueous solutions at high vapor pressures. Chen et al. synthesized bismuth-amino acid coordination polymers (BACPs) with different sizes by heating the aqueous reacting solution of Bi(NO3)3·5H2O and asparagine at different temperatures [30]. The prepared BACPs synthesized in a facile green hydrothermal method exhibited unique biological activities and potential applications in biomedicine. He et al. prepared low-toxicity bismuth asparagine coordination polymer spheres (BACP-2) with sphere-like microstructures of an average 800 nm in diameter through a hydrothermal reaction at 80°C overnight [31]. Solvothermal synthesis is usually carried out in organic media to produce chemicals of refined crystallinity and morphology through a combination of sol-gel and hydrothermal routes. Andrews and coworkers have developed two new bis-carboxylate Bi(III) complexes including PhBi(o-MeOC6H4CO2)2(bipy)·0.5 EtOH and PhBi(C9H11N2O3CO2)2·6H2O, for anti-Leishmanial through a refluxing reaction in ethanol for 10-12 h [32]. Li et al. reported a nine-coordinate Bi(III) complex, (Bi(H2L)(NO3)2)NO3 (Figure 9) that was prepared in methanol [33]. Microwave synthesis is an efficient and environment-friendly method to accomplish various inorganic syntheses to achieve products in high yields within shorter reaction times. The coordination behaviors of bismuth (III) compounds with benzothiazoline were investigated by Mahajan et al. and the reaction takes few minutes under 700 W inside a microwave oven [34].

Figure 9.

(A) Structure of (Bi(H2L)(NO3)2)NO3 with atomic numbering scheme. (B) Polyhedra showing distorted geometry around the bismuth atom. H2L, 2,6-diacetylpyridine bis(4N-methylthiosemicarbazone) (adapted from Ref. [33]).

Several bismuth derivates have revealed antibacterial and antifungal activities. For example, (Bi(H2L)(NO3)2)NO3 shows higher antibacterial properties with the minimum inhibitory concentration (MIC) of 10.66 μM against Gram-positive bacteria B. cereus and Gram-negative bacteria S. typhimurium than the control of antibiotics chloramphenicol (MIC of 96.71 μM against B. cereus and S. typhimurium) and kanamycin sulfate (MIC of 107.3 μM against B. cereus, 53.64 μM against S. typhimurium), respectively [33]. Aqueous colloidal bismuth oxide nanoparticles (Bi2O3 NP) with fungicidal activity against Candida albicans and antibiofilm capabilities were synthesized by Rene and coworkers [35]. Colloidal Bi2O3 NP displayed better antifungal activity against C. albicans growth (colony size is reduced by 85%) and more complete inhibition of biofilm formation than those obtained by chlorhexidine, nystatin, and terbinafine, demonstrating the candidate role of Bi2O3 NP as a fungicidal component of oral antiseptic. Several bis-carboxylate phenylbismuth (III) and tris-carboxylate bismuth (III) complexes reported by Andrews and coworkers showed significant antimicrobial activity against the promastigotes of Leishmania major [32].

It should be noted that although bismuth complexes have been widely applied for medical practice against H. pylori infection in peptic ulcer, some side effects have been reported including disturbances of taste, dizziness, abdominal pain, and mild diarrhea in some patients, and a few cases of parageusia and glossitis. But so far no statistically identified difference in the incidences of side effects was found among the standard triple therapy, bismuth pectin quadruple and sequential therapies, demonstrating the biosafety of bismuth complexes [36, 37]. According to the statistical analysis, 99% of ingested bismuth is in essence not absorbed by human body but is excreted in the feces. The bismuth encephalopathy may therefore result from the long-term ingestion of overdosed bismuth complexes, attributed to the chronically neurologic dysfunction of bismuth. Although bismuth toxicity is usually difficult to occur, it is necessary to control the dosage of bismuth compounds.

Advertisement

5. Conclusion and outlook

Because of the nontoxicity of bismuth (III) salts, there is growing interest to explore various bismuth (III) salts for diverse applications including stripping analysis of heavy metals as well as antimicrobial agents. The bismuth-based sensors for the heavy metals are extensively studied in an effort to replace the mercury-based methods. The precise control of morphology and surface properties of bismuth-based materials on the modified electrode will greatly determine the sensitivity and accuracy of the constructed sensors. On the other hand, bismuth-based compounds as the inorganic pharmaceutical molecules may offer advantages over organic ones for biomedical use. As the dosage is the major cause of neurotoxicity of bismuth compounds, it is of importance to monitor the in vivo efficacy of bismuth-based pharmaceuticals. Along this direction, some cargo molecules of ordered structure such as metal-organic frameworks (MOFs) for the controlled release of bismuth hold potentials to improve the curative effect.

Advertisement

Acknowledgments

The work was supported by National Natural Science Foundation of China (U1703118), a project funded by the Priority Academic Program Development of Jiangsu Higher Education Institutions (PAPD), Jiangsu Shuangchuang Program, Open Funds of the State Key Laboratory for Chemo/Biosensing and Chemometrics (2016015) and the National Laboratory of Biomacromolecules (2017kf05) and Jiangsu Specially-Appointed Professor project, China.

References

  1. 1. Wang J, Lu JM, Hocevar SB, Farias PAM, Ogorevc B. Bismuth-coated carbon electrodes for anodic stripping voltammetry. Analytical Chemistry. 2000;72:3218-3222. DOI: 10.1021/ac000108x
  2. 2. Hocevar SB, Ogorevc B, Wang J, Pihlar BA. Study on operational parameters for advanced use of bismuth film electrode in anodic stripping voltammetry. Electroanalysis. 2002;14:1707-1712. DOI: 10.1002/elan.200290014
  3. 3. Kadara RO, Tothill IE. Development of disposable bulk-modified screen-printed electrode based on bismuth oxide for stripping chronopotentiometric analysis of lead (II) and cadmium (II) in soil and water samples. Analytica Chimica Acta. 2008;623:76-81. DOI: 10.1016/j.aca.2008.06.010
  4. 4. Peng HL, Chan CK, Meister S, Zhang XF, Cui Y. Shape evolution of layer-structured bismuth oxychloride nanostructures via low-temperature chemical vapor transport. Chemistry of Materials. 2009;21:247-252. DOI: 10.1021/cm802041g
  5. 5. Myung Y, Wu F, Banerjee S, Park J, Banerjee P. Electrical conductivity of p-type BiOCl nanosheets. Chemical Communications. 2015;51:2629-2632. DOI: 10.1039/c4cc09295c
  6. 6. Yang D et al. NIR-driven water splitting by layered bismuth oxyhalide sheets for effective photodynamic therapy. Journal of Materials Chemistry B. 2017;5:4152-4161. DOI: 10.1039/c7tb00688h
  7. 7. Rivera EJ et al. Bismuth@US-tubes as a potential contrast agent for X-ray imaging applications. Journal of Materials Chemistry B: Materials for Biology and Medicine. 2013;1:4792-4800. DOI: 10.1039/c3tb20742k
  8. 8. Bierer DW. Bismuth subsalicylate: History, chemistry, and safety. Reviews of Infectious Diseases. 1990;12(Suppl 1):S3-S8
  9. 9. Gorbach SL. Bismuth therapy in gastrointestinal diseases. Gastroenterology. 1990;99:863-875
  10. 10. Borchert H et al. Determination of nanocrystal sizes: A comparison of TEM, SAXS, and XRD studies of highly monodisperse COPt3 particles. Langmuir. 2005;21:1931-1936. DOI: 10.1021/la0477183
  11. 11. Song Y et al. Raspberry-like bismuth oxychloride on mesoporous siliceous support for sensitive electrochemical stripping analysis of cadmium. Molecules. 2017;22:797. DOI: 10.3390/molecules22050797 Basel, Switzerland
  12. 12. Song Y, Jiang H, Bi H, Zhong G, Chen J, Wu Y, Wei W. Multifunctional bismuth oxychloride/mesoporous silica composites for photocatalysis, anti-bacterial test and simultaneous stripping analysis of heavy metals. ACS Omega. 2018;3:973-981. DOI: 10.1021/acsomega.7b01590
  13. 13. Petovar B, Xhanari K, Finsgar MA. Detailed electrochemical impedance spectroscopy study of a bismuth-film glassy carbon electrode for trace metal analysis. Analytica Chimica Acta. 2018;1004:10-21. DOI: 10.1016/j.aca.2017.12.020
  14. 14. Li J, Guo S, Zhai Y, Wang E. High-sensitivity determination of lead and cadmium based on the Nafion-graphene composite film. Analytica Chimica Acta. 2009;649:196-201. DOI: 10.1016/j.aca.2009.07.030
  15. 15. Hutton EA, Ogorevc B, Hocevar SB, Smyth MR. Bismuth film microelectrode for direct voltammetric measurement of trace cobalt and nickel in some simulated and real body fluid samples. Analytica Chimica Acta. 2006;557:57-63. DOI: 10.1016/j.aca.2005.10.003
  16. 16. Xu H et al. Highly ordered platinum-nanotube arrays for oxidative determination of trace arsenic (III). Electrochemistry Communications. 2008;10:1893-1896. DOI: 10.1016/j.elecom.2008.09.037
  17. 17. Bagheri H et al. Simultaneous electrochemical sensing of thallium, lead and mercury using a novel ionic liquid/graphene modified electrode. Analytica Chimica Acta. 2015;870:56-66. DOI: 10.1016/j.aca.2015.03.004
  18. 18. Wang J. Stripping analysis at bismuth electrodes: A review. Electroanalysis. 2005;17:1341-1346. DOI: 10.1002/elan.200403270
  19. 19. Xu H, Zeng LP, Huang DK, Man YZ, Jin LT. A Nafion-coated bismuth film electrode for the determination of heavy metals in vegetable using differential pulse anodic stripping voltammetry: An alternative to mercury-based electrodes. Food Chemistry. 2008;109:834-839. DOI: 10.1016/j.foodchem.2007.12.065
  20. 20. Sosa V, Serrano N, Arino C, Diaz-Cruz JM, Esteban M. Sputtered bismuth screen-printed electrode: A promising alternative to other bismuth modifications in the voltammetric determination of Cd(II) and Pb(II) ions in groundwater. Talanta. 2014;119:348-352. DOI: 10.1016/j.talanta.2013.11.032
  21. 21. Cerovac S et al. Trace level voltammetric determination of lead and cadmium in sediment pore water by a bismuth-oxychloride particle-multiwalled carbon nanotube composite modified glassy carbon electrode. Talanta. 2015;134:640-649. DOI: 10.3016/j.talanta.2014.12.002
  22. 22. Economou A. Bismuth-film electrodes: Recent developments and potentialities for electroanalysis. Trac-Trends in Analytical Chemistry. 2005;24:334-340. DOI: 10.1016/j.trac.2004.11.006
  23. 23. Kadara RO, Tothill IE. Stripping chronopotentiometric measurements of lead(II) and cadmium(II) in soils extracts and wastewaters using a bismuth film screen-printed electrode assembly. Analytical and Bioanalytical Chemistry. 2004;378:770-775. DOI: 10.1007/s00216-003-2351-x
  24. 24. Yang D, Wang L, Chen Z, Megharaj M, Naidu R. Determination of trace lead and cadmium in water samples by anodic stripping voltammetry with a nafionionic liquid-coated bismuth film electrode. Electroanalysis. 2014;26:639-647. DOI: 10.1002/elan.201300622
  25. 25. Baldo MA, Daniele S. Anodic stripping voltammetry at bismuth-coated and uncoated carbon microdisk electrodes: Application to trace metals analysis in food samples. Analytical Letters. 2004;37:995-1011. DOI: 10.1081/al-120030293
  26. 26. Keawkim K, Chuanuwatanakul S, Chailapakul O, Motomizu S. Determination of lead and cadmium in rice samples by sequential injection/anodic stripping voltammetry using a bismuth film/crown ether/Nafion modified screen-printed carbon electrode. Food Control. 2013;31:14-21. DOI: 10.1016/j.foodcont.2012.09.025
  27. 27. Hwang GH, Han WK, Park JS, Kang SG. Determination of trace metals by anodic stripping voltammetry using a bismuth-modified carbon nanotube electrode. Talanta. 2008;76:301-308. DOI: 10.1016/j.talanta.2008.02.039
  28. 28. Yang D, Wang L, Chen Z, Megharaj M, Naidu R. Anodic stripping voltammetric determination of traces of Pb(II) and Cd(II) using a glassy carbon electrode modified with bismuth nanoparticles. Microchimica Acta. 2014;181:1199-1206. DOI: 10.1007/s00604-014-1235-4
  29. 29. Song Y, Jiang H, Wang B, Kong Y, Chen J. Silver-incorporated mussel-inspired polydopamine coatings on mesoporous silica as an efficient nanocatalyst and antimicrobial agent. ACS Applied Materials & Interfaces. 2018;10:1792-1801. DOI: 10.1021/acsami.7b18136
  30. 30. Chen R et al. Facile synthesis of functional bismuth-amino acid coordination polymer nano-structures. Chemical Communications. 2011;47:8136-8138. DOI: 10.1039/c1cc11837d
  31. 31. He NN et al. Exploring the toxicity of a bismuth-asparagine coordination polymer on the early development of Zebrafish Embryos. Chemical Research in Toxicology. 2013;26:89-95. DOI: 10.1021/tx3004032
  32. 32. Andrews PC et al. Anti-Leishmanial activity of homo- and heteroleptic bismuth(III) carboxylates. Journal of Inorganic Biochemistry. 2011;105:454-461. DOI: 10.1016/j.jinorgbio.2010.08.007
  33. 33. Li MX, Yang M, Niu JY, Zhang LZ, Xie SQ. A nine-coordinated bismuth(III) complex derived from pentadentate 2,6-diacetylpyridine bis((4)N-methylthiosemicarbazone): Crystal structure and both in vitro and in vivo biological evaluation. Inorganic Chemistry. 2012;51:12521-12526. DOI: 10.1021/ic301959z
  34. 34. Mahajan K, Swami M, Singh RV. Microwave synthesis, spectral studies, antimicrobial approach, and coordination behavior of antimony(III) and bismuth(III) compounds with benzothiazoline. Russian Journal of Coordination Chemistry. 2009;35:179-185. DOI: 10.1134/s1070328409030038
  35. 35. Hernandez-Delgadillo R et al. Bismuth oxide aqueous colloidal nanoparticles inhibit Candida albicans growth and biofilm formation. International Journal of Nanomedicine. 2013;8:1645-1652. DOI: 10.2147/IJN.S38708
  36. 36. Mesquita MA et al. One-week dual therapy with ranitidine bismuth citrate and clarithromycin for the treatment of Helicobacter pylori infection in Brazilian patients with peptic ulcer. World Journal of Gastroenterology. 2005;11:3566-3569. DOI: 10.3748/wjg.v11.i23.3566
  37. 37. Gao XZ, Qiao XL, Song WC, Wang XF, Liu F. Standard triple, bismuth pectin quadruple and sequential therapies for Helicobacter pylori eradication. World Journal of Gastroenterology. 2010;16:4357-4362. DOI: 10.3748/wjg.v16.i34.4357

Written By

Yiyan Song and Jin Chen

Submitted: 17 October 2017 Reviewed: 22 February 2018 Published: 20 June 2018