The aim of the study in this chapter is to investigate performances shown by courtyard buildings, used widely both as microclimate regulators and as city-wide climate stabilizers especially in the hot-dry climate regions. Furthermore, this study examines atrium buildings having an increasing usage rate in recent years and the presence of comfort problems in particular which have not been resolved for different climate regions. Wind velocity measurements are performed in 36 different points determined in X and Y directions and 17 different points in the Z dimension on the outside of the courtyard considered in this study. In addition, both atrium building typology model and courtyard building typology model are obtained by taking the average courtyard dimensions seen in many regions; by covering open space courtyard section of the geometry with a transparent glass, atrium and courtyard typologies can be obtained. Furthermore, thermal comfort states and energy performances of these two different building typologies in interior courtyard and in building internal volumes for hot-dry, hot-humid and cold climate region conditions as well as the effect of solar radiation values exposing the building surfaces and solar movements during the day on the thermal performance on the building are analysed with CFD FloEFD and Star CCM+ software.
Part of the book: Energy Efficient Buildings