New nanostructural shape memory alloy (55.91 wt% of Ni and 44.03 wt% of Ti) for the production of minimally invasive implantation medical devices (stents) was tested for corrosion resistance under static conditions by dipping it into solutions with various acidities (pH from 1.68 to 9.18) for 2 years, for static mechanical properties and for biocompatibility. The material for investigations was 280‐μm wires before and after thermal treatment at 450°C for 15 min in air and surface mechanical treatment. The characteristic image and size of grains were determined using the transmission electron microscope (TEM), and the phase composition; surface morphology; and the layer‐by‐layer composition were investigated using an X‐ray diffractometer; a scanning electron microscope (SEM); and an Auger spectrometer. The nickel release from the investigated nanostructural nitinol is less in comparison with data for microstructural nitinol in a solution of any acidity. Dissolution in the alkali medium is absent. A significant retardation of the nickel ion release (and insignificant concentration as a whole) and the absence of titanium ion release in the weakly acidic and neutral solutions with polished samples are observed. A simultaneous 7–11% increase in strength and plasticity in comparison with microstructural nitinol was attained. Toxicity of samples has not been revealed.
Part of the book: Shape Memory Alloys
Biocompatible composites obtained using the magnetron sputtering for the production of minimally invasive implantation medical devices (stents) were investigated. Nano- and microdimensional surface layers of Ta, Ti, Ag, and Cu on flat and wire NiTi, Cu, Ti, and SiO2 substrates were created. The phase composition, surface morphology, and the layer-by-layer composition were investigated on an X-ray diffractometer, SEM, and Auger spectrometer. It was shown that the thickness and the structure of surface layers were affected by the sputtering distance, time, power, and the bias voltage at the substrate. The presence of the transition layer that contains both substrate and target elements and provides high adhesion of the surface layer to the substrate has been demonstrated. The material was tested for corrosion resistance under static conditions by dipping into solutions with various acidities (pH from 1.68 to 9.18) for 2 years, static mechanical properties, and biocompatibility in vitro and in vivo. A slight corrosive dissolution was observed only in a medium with a pH of 1.56. Dissolution in the other media is absent. An increase in strength and plasticity in comparison with substrate was attained depending on the nature of the sputtered substance and substrate. Toxicity of samples has not been revealed.
Part of the book: Advances in Composite Materials Development