Open access peer-reviewed chapter

Energy, Economic and Environmental (3E) Assessments on Hybrid Renewable Energy Technology Applied in Poultry Farming

Written By

Yuanlong Cui, Saffa Riffat, Elmer Theo, Tugba Gurler, Xuan Xue and Zohreh Soleimani

Submitted: 24 July 2021 Reviewed: 15 December 2021 Published: 28 January 2022

DOI: 10.5772/intechopen.102025

From the Edited Volume

Alternative Energies and Efficiency Evaluation

Edited by Muhammad Wakil Shahzad, Muhammad Sultan, Laurent Dala, Ben Bin Xu and Yinzhu Jiang

Chapter metrics overview

252 Chapter Downloads

View Full Metrics

Abstract

This chapter aims to design, construct and test a new and renewable heating system for fulfilling the energy demand and ameliorating the interior environment of poultry farming in the UK. This system consists of a photovoltaic/thermal module attached to the polyethylene heat exchanger integrated with a geothermal copper pipe array and heat pump. The thermal and electrical energy performance of the hybrid renewable heating system is investigated based on a numerical model and experimental test. Moreover, the economic analysis (and environmental assessment are conducted. It is concluded that the electrical energy production from the photovoltaic array could reach 11867 kWh per annum whereas the heat pump thermal output is about 30210 kWh per annum. Meanwhile, the overall gas and electrical cost of the hybrid renewable heating system are £320 and £129, which are much less than that of the gas burners system and could save £763 and £750, respectively, resulting in less than 6-year of payback period. The energy consumption of the hybrid renewable heating system could decrease about 28873 kWh, resulting in a reduction in total CO2 emission of approximately 8.3 tons, in comparison with the gas burners system.

Keywords

  • poultry farming
  • photovoltaic/thermal array
  • geothermal copper pipe array
  • energy efficiency
  • economic and environmental assessments

1. Introduction

The poultry industry is a significant economic part, supplying energy, meat, eggs and livelihoods to an increasing human population. Nevertheless, it is highly exposed to global-scale warming and climate change caused by human activities [1]. The direct impacts on poultry farming involve the growth, breeding, health and welfare whereas the indirect influences are owing to the global warming on the productivity of forage crops, pastures and feeds [2]. Poultry farming makes up a large proportion of the world’s entire requirement for family livestock, meanwhile, the global population is going up continuously, which results in a growth in the need for poultry providing over the upcoming decades. To be more specific, compared with 2010, the consumption of poultry meat is anticipated to enhance from 330 to 455 million tons per annum in 2050 [3].

Traditional farming solutions are not the capability of fulfilling this demand, in particular for the broiler breeding. This is because the indoor temperature needs to be controlled with accuracy for achieving optimum growth [4, 5]. And also, the health status of the chicken extremely depends on the ambient temperature inside the poultry shed. In the heating season, it is necessary to sustain indoor air temperature in the range of 21–32°C for broiler birds, while in the cooling season, it should avoid the overheating and heat stress on chicken. What is more, there is major pollutant gas including carbon dioxide (CO2) and ammonia (NH3) emitted from poultry facilities that must be maintained underneath the critical concentration levels of ∼2500 ppm and ∼ 25 ppm, respectively [6].

Although, indoor ambient temperature and harmful gases emission should be controlled effectively, the energy consumption and overall expenses still need to be decreased. Energy is utilized for environmental control including lighting, ventilation cooling and heating, preparation and distribution of feed as well as manure management [7, 8]. Specifically, broiler breeding farming for indoor temperature control makes up 96.3% and 75.5% of the entire thermal and electrical energy demands, respectively. Meanwhile, in laying hen sheds, the power output for indoor condition control and ventilation demand is 58.9% and 43.7%, respectively [9, 10]. Additionally, the electricity expense involving heating, lighting, ventilation and cooling is the biggest part for poultry farmers [11].

Water is a vital input for poultry meat and eggs production and plays an important role in guaranteeing chicken health. The traditional water sources, such as rivers, lakes, rainfall, aquifers and snowmelts are not sufficient to fulfill the minimum water demands. Currently, 61% fresh water is obtained from seawater desalination processes, 21% from brackish water as well as 8% from river water. In general, 90% of fresh water is attained from these three sources and the remaining is extracted from brine, wastewater and other sources. Desalination is regularly utilized to produce freshwater eliminating salts, pollutants and minerals from brackish water [12]. However, desalination technology requires considerably higher energy, cost and greenhouse gas (GHG) emissions compared to traditional water treatment approaches. Currently, two mature technological solutions are employed include thermal and membrane approaches. It is found that the thermal-based approach has much higher energy-intensive compared to membrane-based ones [13, 14]. Specifically, Ahmed et al. [15] found that the desalination capacity across the globe based on the membrane desalination method makes up about 73% whereas the thermal-based solutions account for merely 27% until 2016. Moreover, the membrane approaches require high operating pressure ranging from 55 to 70 bar, by comparison, the normal pressure for the brackish water desalination varies from 15 to 30 bar [16]. Integrating the desalination technologies with renewable energy sources have the potential to produce fresh water for future development. This mainly includes three merits, namely, energy sustainability, future fresh water sustainability and environmental sustainability. Renewable energy technologies like solar photovoltaic (PV), solar photovoltaic/thermal (PV/T) and geothermal heat pumps are state-of-the-art and could become feasible and economically promising for different areas. Nevertheless, when the technologies continue to enhance, the fresh water becomes scarce and fossil fuel energy price increases, thereby renewable energy desalination suits more viable economically. Additionally, the CO2 emission is the major factor by the operation of desalination processes. It is reported [17, 18] that the CO2 emission is over 1500% and it is predictable to increase to 2200% by 2040. Herein, the efficiency enhancement of water and electricity, is vital to regulate CO2 emission to protect the environment.

Hence, to ensure energy sustainable development, decrease cost as well as GHG emission in poultry farming, sustainable energy development in poultry production and reduce cost and GHG emissions, there is a strong incentive to explore energy conservation and deployment of renewable energy technologies for improving energy conversion efficiency for heating and cooling and replacing the utilization of fuel. In comparison with conventional oil and gas energy resources, renewable energy technology shows massive potential owing to its excellent quantity and environmental friendliness.

To be more specific, solar energy technologies including photovoltaic (PV), solar thermal collector and solar photovoltaic/thermal (PV/T) are the ideal solutions for warming poultry shed. This is because they are both inexpensive and efficient to operate and could solve fossil fuel-oriented environmental matters, compared to traditional energy sources such as gas and oil. Gad et al. [19] built a solar energy heating system for poultry shed to assess the energy efficiency and system cost. It is observed that the thermal and electrical efficiencies could achieve 71.6% and 12.5%, respectively. The electricity cost of renewable technology is about 1.12 US $/kg which is less compared to 1.46 US $/kg of the conventional power operating system. Mirzaee Ghaleh et al. [20] built a solar thermal collector system for heating a poultry shed in Iran, and demonstrated that the system could fulfill at least 20% of the energy demand in the heating season. Bazen et al. [21] carried out an economic evaluation of a solar PV system for Tennessee’s poultry farm in USA, and concluded that the effects of initial cost, installed expense and tax credit on the net present value could reach 35%, 10.6% and 15%, respectively. Fawaza et al. [22] performed a techno-economic assessment of a solar heating system for broiler breeding in Lebanon. The results illustrated that the hybrid system can achieve 74% of energy-saving and overlay 84% of heating load demand in the heating season. Moreover, annual operating cost saving is approximately $3389, resulting in a 4.6-year’ payback period. Chen and Sheng [23] proposed a solar thermal vacuum tube collector system for warming poultry shed, and found that the system can save around 148.6 kg of CO2 emissions.

Geothermal energy is a potential heat source to provide space heating for a chicken shed owing to the comparatively constant temperature of the soil. And also it has minimal maintenance during the long operation period. As a result, the influences of the GHP poultry shed on indoor temperature control and energy efficiency assessment are investigated in some case studies [24, 25]. Specifically, Kharseh and Nordell [24] developed an integrated solar-geothermal system for evaluating the energy demand for a poultry shed in Syria. It is concluded that this hybrid unit can generate 92 MWh of heating and 13 MWh of cooling, respectively. Choi et al. [25] applied a GHP unit for heating a broiler in Korea. It is demonstrated that the maximum and minimum indoor temperatures could be maintained in the range of 26.4°C-33.5°C and 22.4°C-30.9°C, respectively.

Green poultry shed is a wise choice for resolving basic and applied problems in connection with livestock production in an economic and ecological way. There is still currently a research gap in the area of investigating the energy, economic and environmental (3E) evaluation to study conversion efficiency, economic and GHG emission elements for design and performance estimation of the renewable energy unit in poultry shed. The major novelty of this work is to utilize the techno-economic evaluation approach to predict the annual electrical and thermal energy output and calculate system electrical and thermal energy cost savings, net present value, payback period and GHG emission.

Advertisement

2. System description

Figure 1 illustrates the fundamental design schematic of the hybrid renewable heating system. To be more specific, the hybrid system could produce highly efficient heating by solar photovoltaic/thermal (PV/T) array with a novel category of cheap polyethylene heat exchanger (PHE) loop assisted a heat pump and couple to a low expense geothermal copper pipe array. The PV/T module can simultaneously produce electrical energy for driving the running of heat pump compressor and thermal energy for inputting to the heat pump evaporator along with the geothermal pipe array. In the meantime, geothermal energy can offset the heat source production from the PV/T module for heat pump condenser, such as in the absence of solar radiation or nighttime. The fan coil as a recirculation device is utilized to provide space heating to the poultry shed.

Figure 1.

Schematic diagram of hybrid renewable heating system.

2.1 JWL poultry farm

This hybrid heating renewable system is installed in an actual poultry farm called John Wright Ltd. (JWL), located in Newark-on-Trent of Nottinghamshire in the East Midlands of England, UK. It has four poultry houses with 40,000 chickens in at a time. Figure 2(a) presents an actual photo of JWL. The dimension of shed 1 is 62 × 8 × 2 m (L × W × D) which is selected for the hybrid heating system because it is the smallest one on-site and thus needs the least heating demand in winter as given in Figure 2(b)-(d). The photo of young birds, the control unit and 66 kW gas burner are shown in Figure 2(e)-(g), respectively. Additionally, in shed 1, the indoor temperature should be maintained in the range from 32–20°C. The relative humidity (RH) varies from 50–70%. Two 66 kW gas burners are utilized to warm the poultry shed in winter.

Figure 2.

JWL photos: (a) satellite view; (b) south view; (c) back view; (d) front view; (e) young birds; (f) heating control unit; (g) 66 kW gas burner.

2.2 Meteorological data

Meteorological data are crucial for assessing the thermal and electrical energy output and shed heating load. Figure 3 describes the average ambient temperature, wind velocity as well as solar radiation [26]. Specifically, the highest average ambient temperature is 17.1°C in August whereas the lowest reaches 4.7°C in December. The monthly wind speed varies from 3.6 m/s to 5.2 m/s on average. Meanwhile, the highest and lowest solar radiation are 207.2 W/m2 in June and 24.2 W/m2 in December.

Figure 3.

Weather conditions: (a) average air temperature and wind velocity; (b) solar radiation in Newark over a year.

2.3 Experimental description

Figure 4 depicts the layout of the hybrid heating system installation. Because the survey presented that there are not any poultry sheds in JWL which are fit for the installation of the PV/T array. Hence, only the workshop, which is located next to shed 1 as presented in Figure 4(a) is fulfilled the requirement of the structural reinforcement. The energy output from the PV/T module is piped down the side of the workshop, under the entrance road and through shed 1 to the plant room as exhibited in Figure 4(b). Moreover, 52 (260Wp) Canadian solar PV panels [27] and four 1 × 12 m PHE mats are mounted on the roof of the workshop with 15° oriented to the south for enhancing solar energy harvesting. The solar PV inverter is placed on the external wall of the workshop as displayed in Figure 4(c)-(d). A 15 kW F1145 NIBE heat pump [28] with R407C refrigerant is designated as it is the biggest capacity the consortium and can afford almost the required thermal energy input from the PV/T and ground copper pipe arrays as given in Figure 4(e). The heat pump system could be employed in reverse to supply cooling in summer if required. Additionally, the fan coil is mounted vertically on the south internal to provide spacing heating for shed 1 as shown in Figure 4(f). Furthermore, there are fifty ground copper pipes with 15 mm diameter and their dimension size is 2.5 × 5 m (length × deep). The overall surface region of the geothermal pipe array is approximately 10 × 10 m. The vertical copper pipes are connected and run back to the plant room.

Figure 4.

Hybrid renewable energy heating system installation: (a) workshop and shed 1; (b) trenched under access road to shed 1; (c) PV/T installed on the workshop roof; (d) inverter along with the external wall; (e) NIBE F1145 heat pump; (f) fan coil.

Advertisement

3. Numerical model

3.1 Energy model

3.1.1 PV/T array

Thermal energy conversion is classified into two processes including solar radiation conversion into thermal energy and transferring collected thermal energy towards PHE. Hence, this dynamic model is expressed by:

Qtt=mPV/TCPV/TTPV/Tt=QabsQPV/TlossQeleE1

where Qt is the overall thermal energy (kW); mPV/T is the mass of PV/T (kg); CPV/T is the heat capacity of PV/T (J/ (kg·K)); TPV/T is the temperature of PV/T (°C); t is the time (s); Qabs is the solar energy absorbed (kW); QPV/T-loss is the overall thermal loss (kW); Qele is the power output (kW).

Qabs=τcαabsAeffIE2

τc is the transmittance of PV/T; αabs is the absorptivity of PV/T; Aeff is the effective area of PV/T (m2); I is the solar radiation (W/m2);

QPV/Tloss=Qconv,c+Qc,sky+Qconv,pl,heo+Qpl,heoE3
Qconv,c=hcvTcTaE4

where hcv is the forced convection coefficient (W/m2·K), which is written as:

hcv=5.7+3.8VwindE5
Tc=30+0.0175×Ι300+1.14×Ta25E6

where Vwind is the wind velocity (m/s); Tc is the PV surface temperature (°C); Ta is the air temperature (°C);

Qc,sky=εcσTc4Ts4E7
Ts=0.037536Ta1.5+0.32TaE8

where εc is the emissivity of PV/T cover layer; σ is the Stefan-Boltzmann’s constant, 5.67 × 10−8 W/m2·K4; Ts is the sky temperature (°C).

Qconv,pl,heo=hairTplTheoE9

where hair is the convective heat transfer coefficient (W/m2·K); Tpl, Theo are the temperature of the EVA layer and PHE wall temperature, respectively (°C).

hair=NuλairδairE10

where λair is the air thermal conductivity (W/m K); δair is air gap thickness between the surface cover and PV module (m).

Nu is the Nusselt number as expressed:

Nu=0.060.017βs90Gr1/3E11

where βs is the title–angle of PV panels; Gr is the Grashoff number given as:

Gr=gTplTheoδair3νair2TairE12
Qpl,heo=εplσTpl4Theo4E13

where εpl is the emissivity of EVA layer;

Qele=ηeAeffIE14

where ηe is the electrical efficiency of PV array (%); Aeff is the effective area of PV array (m2).

The overall heat production is written as:

Qt=AeffhtTaTwE15

where ht is the overall heat transfer coefficient between the water and PV module (W/m2·K); Tw is the water temperature within the PHE (°C).

ηt=QtAeffIE16

where ηt is the thermal efficiency (%).

3.1.2 Ground copper pipe array

To supply an adequate heat source for the evaporator of the heat pump unit, a low expense geothermal copper pipe array is developed. In lights of the heat transfer fields, it is categorized into solid and fluid regions [29].

3.1.2.1 Solid field

The solid field contains soil and pipe wall as presented:

ρsoilcsoilTst=xλsoilTsx+yλsoilTsy+zλsoilTszE17
ρpipecpipeTpt=xλpipeTpx+yλpipeTpy+zλpipeTpzE18

where ρ is the density (kg/m3); c is the thermal capacity (J/kg·°C); λ is the thermal conductivity (W/m·K).

3.1.2.2 Fluid field

The energy balance equation of the inlet pipe is given as:

ρfluidcfluidTinlett+ρcvfTinletz=λfluid2Tinletz2+bigTgroutTinletE19

The energy balance equation of the outlet pipe is expressed as:

ρfluidcfluidToutlett+ρcvfToutletz=λfluid2Toutletz2+bogTgroutToutletE20

3.1.3 Heat pump

The heat source of the heat pump is provided by PV/T and geothermal copper pipe to offer a comfortable climate for the shed in the heating season. Hence, a heat pump model is expressed as [30]:

mr=Vcωρr,suc1+Cv1Pr,condPr,evap1nE21
Δξcomp=ξr,disξr,suc=nn1Pr,evapρr,sucPr,condPr,evapn1n1E22
Qel=mrΔhcompηcompE23

where mr is the refrigerant mass flow rate (kg/s); Vc is the compressor swept volume (m3); ω is the compressor rotational speed (rev/s);

The coefficient of performance (COP) is given as:

COPh=QheatingQelE24

3.2 Economic model

Economic policy has a vital effect on the life cycle cost (LCC) analysis in lights of the hybrid renewable heating system. Hence, the LCC is given as [31, 32]:

LCC=EIC+i=1nESEC+EME+EPC+EITSE25

where LCC is the system lifetime expense (£); EIC is the original expense (£); ESEC is the system energy cost (£); EME is the maintenance cost (£); EPC is the system periodic cost (£); EITS is the system income tax savings (£).

The payback period (PBP) is employed to determine the time required to recoup the fund expended in an investment [33, 34].

PBP=X+YZE26

where X is the number of years of final recovery (£); Y is the balance amount to be recovered (£); Z is the cash inflow (£).

Advertisement

4. Results and discussion

4.1 Model validation

Before performing the prediction of the annual thermal and electrical energy output, it is necessary to validate the accuracy of the numerical model. Hence, the comparisons between numerical and experimental results, in terms of the PV electrical energy production, PHE and thermal energy output from the heat pump, are analyzed based on the error analysis model from 01/Nov/2016 to 31/Jan/2017.

Error=TnumericalTexperimentalTnumericalE27

4.1.1 Electrical energy production from PV array

Figure 5 displays the comparison of daily electrical energy output from PV array based on the simulation and test results. It is concluded that the error is up to 14.93% occurred at the termination of the operating phase, the mean error reaches 9.26%. Moreover, the experimental data demonstrated that the total electrical energy production could achieve 1125.89 kWh from 01/Nov/2016 to 31/Jan/2017 (228 days), by contrast, the numerical result exhibits close proximity of value, achieving 1247.51 kWh within a 10% error. This means that the numerical result is in very good agreement with experiment data, which validates the reliability of the numerical model.

Figure 5.

Electrical energy output from PV array.

4.1.2 Thermal energy output from PHE

It can be observed from Figure 6 that the temperature variation between the experimental data and the numerical result has a similar trend. The highest thermal fluid temperature within the PHE reaches 15.75°C on 10/NOV/2016, by comparison, the lowest one is 0.75°C on 25/JAN/2017. And also, the minimum temperature difference was around 3.29% on 31/DEC/2016, the mean one being 9.11%, while the maximum temperature difference is approximately 14.72% on 14/NOV/2016.

Figure 6.

Thermal energy output from PHE.

4.1.3 Thermal output from ground copper pipe

Figure 7 displayed a similar temperature change tendency between the simulation and test results. Specifically, the temperature of the test could realize up to 14.23°C on 15/JAN/2017 whereas the lowest temperature could reach 0.89°C on 08/NOV/2016. Additionally, the maximum, minimum and average relative errors are 11.33% on 16/DEC/2016, 2.40% on 15/JAN/2017 and 6.36%, as clarified in Table 1.

Figure 7.

Heat production from ground copper pipe.

DatePV electrical output (%)PHE thermal output (%)Geothermal thermal output (%)Heat pump output (%)
03/NOV/201614.8412.398.077.01
14/NOV/20164.1514.987.076.33
28/NOV/20169.0511.866.735.94
15/DEC/20168.229.7514.795.49
23/DEC/20163.488.786.129.01
31/DEC/201614.883.294.988.28
08/JAN/201714.938.504.478.86
21/JAN/20178.458.912.409.30
26/JAN/20175.383.492.579.13

Table 1.

Relative error analysis of PV electrical, thermal, geothermal thermal and heat pump outputs.

4.1.4 Thermal energy output from the heat pump

Figure 8 compared the thermal energy output from the heat pump system, and found that the daily maximum and minimum differences are about 9.30% appeared on 16/JAN/2017 and 5.49% occurred on 05/DEC/2016, respectively. Consequently, the numerical model could be employed to assess the annual thermal and electrical energy output of the hybrid renewable heating system over a year.

Figure 8.

Thermal energy output from the heat pump system.

Table 1 illustrated the relative error analysis of PV electrical, thermal, geothermal thermal and heat pump outputs between simulation results and experimental data. It is found that all error values are less than 15% which fulfill the requirement.

4.2 Year-round system performance assessment

Figure 9 depicts the monthly power energy production and efficiency from the PV array. It can be concluded that the minimum and the maximum monthly electrical energy generation are around 335.81 kWh with the lowest efficiency (about 14.85%) in December and 1830.35 kWh with the highest efficiency (about 15.9%) in June, respectively. And also, the overall electrical energy obtained from the PV array could reach 11,867 kWh during a year. This means that it not only can meet the power demand of the poultry shed, but also could supply around 43.5% power requirement of the heat pump compressor operating.

Figure 9.

Monthly PV electrical energy production and efficiency.

Additionally, diminishing the PV surface temperature contributes to increasing the voltage and electrical efficiency. The PHE under the PV array could help to decrease the PV surface temperature resulting in a PV electrical efficiency enhancement. Figure 10 exhibits the monthly thermal energy output and COP variation of the heat pump unit. Results show that the highest and the lowest monthly thermal energy output could achieve 3848.77 kWh in July and 1610.77 kWh in February, respectively. And also, the overall thermal energy output is about 30210.98 kWh per annum. This means that some capacity of the gas burners would be needed alongside the heat pump to warm the shed sufficiently, especially from December to February.

Figure 10.

Monthly thermal energy output and COP of heat pump system.

Furthermore, the highest and lowest PV/T thermal efficiency could reach 28.3% in June and 7.3% in December. When the PV/T operates in conjunction with the geothermal copper pipe array, the COP of the heat pump could achieve up to 5.01 in June, while a minimum COP of 2.17 can be achieved in December.

4.3 Economic assessment

It can be observed from Figure 11 that the comparison of gas and electricity cost between the current system and PV/T and heat pump system each period. Notably, the overall cost of the PV/T with heat pump system is lower than the gas burners system. To be more specific, the gas cost of the PV/T with heat pump system is approximately £319.74, which is significantly lower than that of the gas burner system (approximately £1083), saving about £763. Similarly, the electrical cost of the PV/T with heat pump system is approximately £128.52, which is lower compared to the gas burner system (approximately £893), saving about £750. Additionally, the payback period is about 5.5 years.

Figure 11.

Comparison of gas and electrical cost between gas burners and hybrid renewable heating systems.

4.4 Environmental evaluation

To perform the environmental evaluation, the CO2 emissions related to gas and electricity prices are needed, as applied to the UK. Therefore, the values assigned to the parameters in this study are provided [34, 35] including 0.5246 kg CO2 (e)/ kWe h for electricity and 0.1836 kg CO2 (e)/kWth h for gas. Additionally, in the UK, the electricity price at Feed-In Tariff (FIT) and the renewable heat incentive (RHI) are £0.1097/kWh and £0.052/kWh, respectively [36, 37]. Results confirmed from Figure 12 that the gas burners system produces energy consumption of about 39,851 kWh resulting in about 10.27 tons CO2 emission, while the hybrid renewable heating system has an only energy consumption of 10,978 kWh which is equivalent to 2.026 tons CO2 emission. This indicates that the novel hybrid system could save about 28,873 kWh energy consumption, making for a reduction of total CO2 emission of approximately 8.3 tons. Table 2 describes the calculation processes of energy consumption, CO2 emission and operating cost of the gas burners and PV/T with heat pump systems.

Figure 12.

Comparison of energy consumption and CO2 emission between gas burners and hybrid renewable heating systems.

System/itemsGas burners systemPV/T with heat pump systemSaving
Total energy consumption, kWh (228 days)31,199 + 8652 = 39,85110946.57 + 31.21 = 10,97828,873 kWh
CO2 emission, tons per (228 days)31,199 × 0.1836 + 8652 × 0.5246
=10266.98/1000 = 10.27 tons
10946.57 × 0.1836 + 31.21 × 0.5246
=2026.16 kg/1000 = 2.03tons
8.3 tons
Operating cost (£) (228 days)£1083 + £893 = £1976£319.74 + £128.52 = £448.26£1528

Table 2.

Calculation process of energy consumption, CO2 emission and operating cost between gas burners and PV/T with heat pump systems.

4.5 Summary

To sum up, the hybrid renewable energy heating system could save 28,873 kWh of thermal and electrical energy consumption, £1528 of operating cost with 5.5 years’ payback period and 8.3 tons of CO2 emission. Additionally, the electrical output of the PV/T array could achieve approximately 11,867 kWh per annum whereas the thermal energy output is about 30,210 kWh per annum.

According to previous studies [19, 22, 25, 38], it is observed that the hybrid of solar and geothermal energy systems used in a poultry house is rare. Specifically, Fawaz et al. [22] demonstrated that the solar-assisted localized heating system could save approximately 74% of the energy demand and exhibit a 4.6 years of payback period. To improve the chicken meat and eggs production, Gad et al. [19] concluded that the thermal efficiency of the solar heating system is about 71.6% whereas the PV electrical efficiency is 12.5%. Choi et al. [25] designed, constructed and tested a geothermal heat pump system for ameliorating the interior environment of the poultry shed. It is demonstrated that the average interior air temperature could be kept in the range from 24.8 to 32.2°C whereas the relative humidity varies from 45.2 to 72.6%. Moreover, the GHP poultry house could save about 92% of the overall energy expense in comparison with the normal poultry shed. And also, the concentration of CO2 in the GHP poultry house could be decreased by 3299 ppm, by comparison, in the conventional shed, it is decreased by 4945 ppm. Uzodinma et al. [38] assessed the performance of a solar thermal collector with a phase change materials system for poultry incubating chamber, and observed that the temperature of the chamber could be kept in the range from 36 to 39°C, meanwhile, an average egg hatchability could reach 62.37%.

Herein, this proposed hybrid PV/T with heat pump system could allow taking the benefit of high solar irradiation rates and soil heat, thus improving system performance, ameliorating the interior environment of poultry shed and boost meat and eggs production.

Advertisement

5. Conclusions

In this chapter, a novel PV/T with PHE array coupled to a low expense geothermal copper pipe array and heat pump system is installed in the JWL poultry farm. A numerical model is established and has a good agreement with experimental data within a 15% error. In the meantime, the yearly system energy output is predicted based on the Newark-on-Trent of Nottinghamshire, UK weather conditions. Moreover, the comparisons of the gas cost, electrical cost and CO2 emission are investigated between the gas burners and hybrid renewable heating systems. Some significant outcomes are obtained as below:

  • The electrical production from the PV array could realize 11,867 kWh per annum. It not only meets the power requirement of the poultry shed, but also supply around 43.5% power needed for the heat pump compressor operation.

  • The heat pump thermal energy output is about 30,210 kWh per annum, which indicates that some capacity of the gas burners would be required alongside the heat pump to warm the shed adequately in winter.

  • When the PV/T operates in conjunction with the geothermal pipe, the COP of the heat pump could reach up to 5.01 in June, while a minimum COP of 2.17 could be achieved in December.

  • The overall gas and electrical cost of the hybrid renewable heating system are £320 and £129, which are much less than that of the gas burners system saving £763 and £750, respectively, resulting in less than 6 years of payback period.

  • In comparison with the gas burner, the energy consumption of the hybrid renewable heating system can decrease about 28,873 kWh, making for a decline of total CO2 emission of approximately 8.3 tons.

Advertisement

Acknowledgments

The authors would like to acknowledge the support from Innovate UK Agri-Tech Catalyst for the Welfare Enhanced Living Conditions for Healthier Chickens (WelChic) project (131897).

Advertisement

Conflict of interest

The authors declare that they have no known competing financial interests or personal relationships that could have appeared to influence the work reported in this paper.

Advertisement

Acronyms and abbreviations

CO2carbon dioxide
COPcoefficient of performance
FITfeed-in tariff
GHGgreenhouse gas
GHPgeothermal heat pump
LCClife cycle cost
NH3ammonia
PBPpayback period
PHEpolyethylene heat exchanger
PVphotovoltaic
PV/Tphotovoltaic/thermal
RHrelative humidity
RHIrenewable heat incentive
WelChicwelfare enhanced living conditions for healthier chickens
3Dthree-dimensional
3Eenergy, economic and environmental
Advertisement

Nomenclature

Aarea (m2)
cthermal capacity (J/kg·K)
Hdepth (m)
hheat transfer coefficient [W/(m·K)]
λthermal conductivity [W/(m·K)]
rradius (m)
Ttemperature (°C)

References

  1. 1. Wreford A, Topp CFE. Impacts of climate change on livestock and possible adaptations: A case study of the United Kingdom. Agricultural Systems. 2020;178:102737
  2. 2. Rasul G. Twin challenges of COVID-19 pandemic and climate change for agriculture and food security in South Asia. Environmental Challenges. 2021;2:100027
  3. 3. Izar-Tenorio J, Jaramillo P, Griffin WM, Small M. Impacts of projected climate change scenarios on heating and cooling demand for industrial broiler chicken farming in the eastern U.S. Journal of Cleaner Production. 2020;255:120306
  4. 4. Anastasiadis F, Tsolakis N. Environmental hotspots analysis: A systematic framework for food supply chains and implementation case in the UK poultry industry. Journal of Cleaner Production. 2021;305:126981
  5. 5. Costantino A, Fabrizio E, Ghiggini A, Bariani M. Climate control in broiler houses: A thermal model for the calculation of the energy use and indoor environmental conditions. Energy and Buildings. 2018;169:110-126
  6. 6. Du L, Hu C, Yang C, Yang L, Du H, Li Q, et al. Investigation of a preliminary ventilation energy-recovery system for poultry houses. Computers and Electronics in Agriculture. 2020;175:105521
  7. 7. Zhao Y, Shepherd TA, Li H, Xin H. Environmental assessment of three egg production systems–part I: Monitoring system and indoor air quality. Poultry Science. 2015;94:518-533
  8. 8. Ren G, Lin T, Ying Y, Chowdhary G, Ting KC. Agricultural robotics research applicable to poultry production: A review. Computers and Electronics in Agriculture. 2020;169:105216
  9. 9. Costantino A, Fabrizio E, Biglia A, Cornable P, Battaglini L. Energy use for climate control of animal houses: The state of the art in Europe. Energy Procedia. 2016;101:184-191
  10. 10. Weindl I et al. Livestock in a changing climate: Production system transitions as an adaptation strategy for agriculture. Environmental Research Letters. 2015;10:094021
  11. 11. Bazen EF, Brown MA. Feasibility of solar technology (photovoltaic) adoption: A case study on Tennessee's poultry industry. Renewable Energy. 2009;34(3):748-754
  12. 12. Jones E, Qadir M, van Vliet MTH, Smakhtin V, Kang S, mu. The state of desalination and brine production: A global outlook. Science of the Total Environment. 2019;657:1343-1356
  13. 13. Tomaszewska B, Akkurt GG, Kaczmarczyk M, Bujakowski W, Keles N, Jarma YA, et al. Utilization of renewable energy sources in desalination of geothermal water for agriculture. Desalination. 2021;513:115151
  14. 14. Al-Karaghouli A, Kazmerski LL. Energy consumption and water production cost of conventional and renewable-energy-powered desalination processes. Renewable and Sustainable Energy Reviews. 2013;24:343-356
  15. 15. Ahmed FE, Hashaikeh R, Hilal N. Solar powered desalination-technology, energy and future outlook. Desalination. 2019;453:54-76
  16. 16. Dashtpour R, Al-Zubaidy SN. Energy efficient reverse osmosis desalination process. Journal of Membrane Science. 2012;3(4):339
  17. 17. Shahzad MW, Burhan M, Ang L, Ng KC. Energy-water-environment nexus underpinning future desalination sustainability. Desalination. 2017;413:52-64
  18. 18. Shahzad MW, Ng KC, Burhan M, Chen Q, Jamil MA, Imtiaz N, et al. Demystifying integrated power and desalination processes evaluation based on standard primary energy approach. Thermal Science and Engineering Progress. 2022;27:101153
  19. 19. Gad S, El-Shazly MA, Wasfy KI, Awny A. Utilization of solar energy and climate control systems for enhancing poultry houses productivity. Renewable Energy. 2020;154:278-289
  20. 20. Mirzaee-Ghaleh E, Omid M, Keyhani A, Javadikia P. Forecasting the thermal load for implementing solar energy in a model poultry house. Journal of Agricultural Engineering and Biotechnology. 2013;1:30-36
  21. 21. Bazen EF, Brown MA. Feasibility of solar technology (photovoltaic) adoption: A case study on Tennessee’s poultry industry. Renewable Energy. 2009;34:748-754
  22. 22. Fawaza H, Abiad MG, Ghaddar N, Ghali K. Solar-assisted localized ventilation system for poultry brooding. Energy and Buildings. 2014;71:142-154
  23. 23. Chen W, Sheng C. Mitigation of carbon dioxide emissions in a warming system for chicks by using solar energy. Life Science Journal. 2013;10:1845-1850
  24. 24. Kharseh M, Nordell B. Sustainable heating and cooling systems for agriculture. International Journal of Energy Research. 2014;35:415-422
  25. 25. Choi HC, Salim HM, Akter N, Na JC, Kang HK, Kim MJ. Effect of heating system using a geothermal heat pump on the production performance and housing environment of broiler chickens. Poultry Science. 2012;91:275-281
  26. 26. Weather statistics for Newark-On-Trent, England. Available at: Newark-On-Trent, Nottinghamshire, United Kingdom Historical Weather Almanac (worldweatheronline.com)
  27. 27. CS6P-250P (250W) Solar Panel. Available at :CS6P-P_en.cdr (zonnepanelen.net)
  28. 28. Ground Source Heat Pump NIBE™ F1145. Available at: http://www.ecolivinguk.com/media/29491/nibe_product_guide_ f1145.pdf
  29. 29. Cui Y, Zhu J. 3D transient heat transfer numerical analysis of multiple energy piles. Energy and Buildings. 2017;134:129-142
  30. 30. Jin H, Spitler JD. A parameter estimation based model of water-to-water heat pumps for use in energy calculation programs. ASHRAE Transactions. 2002;108:4493-4510
  31. 31. Gu Y, Zhang X, Myhren JA, Han M, Chen X, Yuan Y. Techno-economic analysis of a solar photovoltaic/thermal (PV/T) concentrator for building application in Sweden using Monte Carlo method. Energy Conversion and Management. 2018;165:8-24
  32. 32. Cui Y, Zhu J, Zoras S, Qiao Y, Zhang X. Energy performance and life cycle cost assessments of a photovoltaic/thermal assisted heat pump system. Energy. 2020;206:118108
  33. 33. Chandra S, Yadav A. Site selection based on thermo mechanical decay and payback period of solar PV system: Need of present scenario. Materials Today: Proceedings. 2021;43 Part 1:287-292
  34. 34. Herrando M, Markides CN, Hellgardt K. A UK-based assessment of hybrid PV and solar-thermal systems for domestic heating and power: System performance. Applied Energy. 2014;122:288-309
  35. 35. Amrizal N, Chemisana D, Rosell JI. Hybrid photovoltaic–thermal solar collectors dynamic modeling. Applied Energy. 2013;101:797-807
  36. 36. Ofgem. Feed-in Tariff: Guidance for renewable installations. 2016. Available at: 2005_fits_guidance_for_installations_v15_clean.pdf (ofgem.gov.uk) [Accessed: June 20, 2016
  37. 37. Ofgem. Tariffs and payments: Domestic RHI. 2016. Available at: Tariffs and payments: Domestic RHI | Ofgem [Accessed: April 15, 2016]
  38. 38. Uzodinma EO, Ojike O, Etoamaihe UJ, Okonkwo WI. Performance study of a solar poultry egg incubator with phase change heat storage subsystem. Case Studies in Thermal Engineering. 2020;18:100593

Written By

Yuanlong Cui, Saffa Riffat, Elmer Theo, Tugba Gurler, Xuan Xue and Zohreh Soleimani

Submitted: 24 July 2021 Reviewed: 15 December 2021 Published: 28 January 2022