1. Introduction
Valve replacement has been the standard treatment for aortic stenosis until the development of transcatheter aortic valve implantation (TAVI). Although TAVI provides a treatment with fairly acceptable outcomes for patients with high surgical risk, aortic valve replacement remains essential even in the TAVI era, because surgical treatment is indicated when TAVI cannot be performed due to a small aortic annulus or inappropriate access route. In addition, surgical treatment may be necessary when complications develop during TAVI procedures. Therefore, a more meticulous procedure is required for surgeons. With an increasing number of elderly patients who need surgical treatment and are at high risk due to aging, comorbidities, or medications such as steroids or antiplatelet drugs, trivial pitfalls during surgery can lead to catastrophic results. Furthermore, many patients with hemodialysis and marked systemic calcification require aortic valve surgery in Japan [1].
Complications encountered during surgery for aortic stenosis can be associated with catastrophic events such as myocardial infarction, cerebral embolism or aortic dissection. This is because a calcified aortic valve rarely exists alone, but is often associated with marked and diffuse calcification in the aorta, coronary arteries, mitral valve or even cerebral vessels [2]. The goal of surgical treatment is to implant a prosthetic valve of adequate size in each individual patient without perivalvular leak, while avoiding undesirable complications such as stroke, cardiac events or bleeding. This chapter is devoted to the tips and pitfalls in aortic valve replacement of calcified aortic valves with a discussion of preoperative and intraoperative strategies to achieve the best possible outcomes.
2. Calcified aortic valve
2.1. Etiologies of calcification
There are three main etiologies of aortic stenosis. The location and extent of calcification in the aortic valve varies depending on its etiology (Fig. 1). In rheumatic valvular disease, there is initial thickening and fusion of the cusps with later involvement of the annulus. The fusion of cusps results in the formation of a valve orifice that looks like a fish mouth. There is also severe mitral valve calcification in patients with combined valvular disease. In arteriosclerotic aortic stenosis, calcification is most prominent in the annulus, sinus of Valsalva and ascending aorta. Calcification of the cusps and calcium deposits on them markedly limit cusp opening. In bicuspid aortic stenosis, disease on the annulus is rather mild but fusion of the commissures reduces the valve orifice area and forms a slit-like orifice. Calcification is often present in bicuspid aortic stenosis, but is rather mild compared with that in arteriosclerotic aortic stenosis.
2.2. Removal of calcium
A calcified aortic valve can be a cause of arterial embolism resulting in stroke or myocardial infarction [3-5]. A mobile mass is occasionally found attached to the calcified portion of the aortic valve. A calcified aortic valve as well as the presence of a mobile mass can be assessed by transthoracic echocardiography. Computed tomography (CT) is suitable for precisely assessing the presence and extent of calcification in the annulus and the entire aorta [6,7]. As the calcified cusps are resected, calcium in the annulus needs to be adequately removed to allow subsequent sutures for valve implantation. Calcium deposits are hard but easily crumble into pieces. They can be crushed by clamps and removed or can be fragmented by a Cavitron Ultrasound Surgical Aspirator (CUSA). Either way, loosened calcium needs to be carefully eliminated to prevent it from entering the left ventricle and causing stroke, or entering the left coronary artery and causing myocardial infarction. Digital palpation for irregularity and rigidity is helpful for evaluating the adequacy of calcium removal. To minimize the chance of perivalvular leakage following valve implantation, the inner aspect of the annulus should be smooth with the sewing cuff of the prosthetic valve sealing the small gaps between the sutures.
However, excessive removal of calcium may result in perforation of the aortic root or damage of the mitral valve [8]. Fig. 2 summarizes intraoperative transesophageal echocardiography (TEE) assessment and several measurements on the calcified aortic valve [9].
The extent of calcification should be carefully checked in the annulus and the aorta (described later). It is important to measure the dimensions of the annulus and sinotubular junction. When the latter is equal to or smaller than the former, difficult insertion of the prosthesis may be encountered. Although the valve can be narrowly inserted by distorting the bioprosthetic valve or the aorta, calcification in the aorta or sinotubular junction makes the latter difficult.
Acoustic shadow indicates the presence and extent of calcification. Fig. 3 shows three different degrees of calcification in the annulus of the noncoronary cusp. When it is transmural or continues to the anterior mitral leaflet as shown in Fig. 3C, excessive removal of calcium should be avoided and limited to a reasonable depth.
2.3. Optimizing valve size
A calcified aortic valve limits the size of the prosthetic valve that can be implanted. When the aortic annulus is too small, patient-prosthesis mismatch can arise that may lead to sustained pressure overload of the left ventricle and subsequent chronic heart failure. A bioprosthetic valve is desirable for elderly patients with poor anticoagulation compliance to minimize the risk of cerebral infarction, or in patients that need antiplatelet therapy (patients with stroke or coronary stents); however, there are occasions where only a small-sized mechanical valve can be inserted due to a small aortic annulus [19]. Several solutions are illustrated in Fig. 4.
2.3.1. Annular dilatation
To enlarge the annulus, the aortotomy incision line is extended proximally toward the commissure between the left and non-coronary cusps or toward the noncoronary sinus of Valsalva (Fig. 4A) [11]. However, a markedly calcified annulus and/or sinus of Valsalva makes this procedure difficult or even increases the risk of uncontrollable bleeding at the suture line. Preoperative CT assessment or intraoperative TEE is helpful for making a decision.
2.3.2. Supra-annular implantation
This allows implantation of a prosthetic valve that is one size larger and is commonly used in many institutes (Fig. 4B). A non-everting suture is placed along the annulus. However, this generates a risk of occlusion of the coronary ostium when it is located at an unusually low level. It can be evaluated by CT, but may be missed by coronary angiography. Intraoperative TEE is helpful for making a decision (Fig. 2A).
2.3.3. Interrupted suture
Although mattress sutures slightly reduce the circumference of the aortic annulus, interrupted sutures allow insertion of a prosthetic valve with the same size as the annulus (Fig. 4C). This slightly increases the number of sutures required. Since appropriate seating of the sewing ring on the annulus cannot be confirmed by the pledget adjacent to the sewing cuff, it needs to be inspected through the valve by manually opening the leaflet. When the annulus is severely calcified, it is important to prevent a gap between the annulus and sewing ring. Furthermore, cutting of annular tissue should be avoided while the suture is tied. Two other solutions are stentless aortic valve implant [12,13] and apicoaortic conduit [14-16]. The reader should consult the literature for further details on these two methods.
3. Calcified aorta
Calcification in the aorta occasionally necessitates modification of the surgical strategy because of the safety of arterial cannulation, aortic cross-clamping, insertion of a root cannula, aortotomy and suture closure of the aorta. Calcification can be precisely assessed by preoperative CT. The principal strategy can be selected based on the CT findings. Intraoperative TEE and/or epiaortic echo may be used to identify the precise location and extent of calcification and atheromatous plaque in the surgical field. Echo-guided marking of calcification on the aorta can be helpful for subsequent surgical procedures. Three-dimensional (3D) TEE is capable of visualizing the entire ascending aorta (Fig. 5). The xPlane mode allows serial sections of the aorta to be scanned from the aortic valve to the aortic arch. The diseased portion of the aorta can be located by digital compression of the aorta during visualization by TEE.
Fig. 6 demonstrates several TEE images of calcified aortas. Fig. 6A shows a calcified aortic wall just distal to the sinotubular junction, accompanied by acoustic shadow. The aortotomy line needs to be shifted distally. Calcification can take place at the level of the aortic cross-clamp, where the right pulmonary artery crosses behind the ascending aorta (Fig. 6B). Fig. 6C shows calcification at the level of arterial cannulation. The use of epiaortic echo is desirable to accurately locate the site of calcification. Fig. 6D is a TEE image of rather mild calcification. In this case, the aorta could be clamped without cerebral complications. Fig. 6E shows atheromatous plaque on the anterior wall of the ascending aorta at the level of cross-clamping and insertion of the root cannula. Since enhanced CT is not often employed for preoperative assessment before aortic valve replacement, care should be taken to avoid missing such findings. Palpation of the aorta cannot detect the presence of atheroma. TEE or epiaortic echo is needed to avoid an embolic event.
3.1. Arterial cannulation and insertion of a root cannula
Calcification often involves the distal portion of the ascending aorta and makes arterial cannulation difficult (Fig. 6C). Since an adequate space for aortotomy needs to be spared for procedures on the aortic valve, the cannulation site should not be too proximal. Arterial cannulation of a calcified aorta might cause aortic dissection at the time of cannulation and/or difficult hemostasis following decannulation. When aortic cannulation is not desirable, the axillary or femoral artery can be used as an alternative perfusion route. However, in patients with a calcified aorta, there can also be stenosis or atheromatous lesions in the innominate or iliac artery; thus, it is mandatory to check for these lesions before surgery. The insertion site of the root cannula should be carefully determined. Epiaortic echo is helpful for examining the presence and location of calcification and atheroma. A safe placement of the root cannula requires a certain length of nearly normal wall, which allows secure closure of the puncture site. When an adequate area is not available, an elastic needle may be used instead.
3.2. Aortic cross-clamp
In cases with severe and diffuse calcification of the aorta (porcelain aorta), concomitant replacement of the ascending aorta should be considered [17-19]. However, in the majority of calcified aortic valve cases, calcification is present but not severe; it is often scattered without apparent atheromatous plaque on the intima. It is important to determine the safety of aorta cross-clamp in all cases, since cross-clamp of a calcified aorta potentially causes fracture of the calcified layer that can lead to aortic dissection or embolism of fragmented calcium.
Fig. 7 shows the strategy of the author. When calcification is diffuse and thick or atheromatous plaque is present, aortic cross-clamp is avoided. If the calcified layer is partial and not thick, the aorta may be clamped with some fracture of the calcified portion, but without incompetent clamp or the development of dissection. The clamp may be applied as parallel to the calcified wall as possible to minimize fracture of the calcified section and the shear force on the intima. Initially, the ratchet is locked slowly and less deeply. The blood flow in the proximal aorta is checked with TEE before antegrade cardioplegia is given. When there is some leak through the clamp site, the ratchet is advanced. If full clamp is not effective, another straight clamp is added adjacent to the first clamp or conversion to aortic repair is considered, depending on the risk of aortic repair in each individual case. It should be kept in mind that a clamp on the calcified aorta flattens the proximal aorta and narrows the surgical field following aortotomy. In the case shown in Fig. 6D, the aorta was carefully clamped and valve replacement was performed without neurologic sequelae. For porcelain aorta, endovascular clamping may be another option [20].
3.3. Aortotomy
An incision line is determined based on the distribution of calcification. It may be modified from the standard J-shaped incision line to a rather transectional or more oblique and distal incision. In the case shown in Fig. 6A, aortotomy at a more distal level or meticulous removal of calcification is needed. If there is an insufficient margin for suture closure of the aortotomy (at least 1 cm in width), the surgeon should be prepared for difficult suturing. When the calcified portion of the aorta is to be incised and sutured, calcium needs to be carefully removed following aortotomy, but before implanting a prosthetic valve. The use of CUSA is helpful for reducing the amount of calcium, enabling an adequate attachment of the aortic walls during suture closure. A new device for this purpose may be helpful [21].
4. Coronary arteries
Myocardial protection is one of the most important issues in aortic valve replacement. Left ventricular hypertrophy and/or coronary artery disease is often associated with aortic stenosis. In addition, surgical procedures may potentially cause new myocardial ischemia. Therefore, careful observation of coronary perfusion is essential. Fig. 8 shows visualization of the coronary arteries with TEE. The coronary arteries can be visualized bilaterally in the majority of cases and coronary artery assessment is done routinely in our institute. The ostia of the right and left coronary arteries are depicted in the short-axis view at the level of sinus of Valsalva (Fig. 8 A,B). The right coronary artery travels in the groove between the right atrium and right ventricle, whereas the left coronary artery crosses behind the pulmonary artery. The left main truncus divides into the left anterior descending and left circumflex arteries. The right coronary ostium can also be depicted in the midesophageal aortic valve long-axis view, giving an idea of its distance from the annulus (Fig. 8C).
To further visualize the distal portion of the left coronary artery, the scanning plane is rotated counterclockwise from the midesophageal aortic valve long-axis view (Fig. 8D). The left coronary sinus takes the place of the noncoronary sinus, and the short-axis view of left main truncus appears. The left anterior descending artery courses toward the 6 to 7 o'clock direction. The distal portion of the left circumflex artery is visualized in the atrioventricular groove. With the 3D en face view, the height of coronary take-off can be observed (Fig. 8E). The author meticulously uses TEE for intraoperative assessment of coronary perfusion, because it is the most important factor that affects the outcomes of aortic valve replacement, especially for calcified aortic valves. Several pitfalls related to myocardial ischemia are shown in Fig. 9.
4.1. Short left main truncus
The left main truncus is occasionally found to be short (Fig. 9A). As the cannula is forcefully thrust into the ostium, the cannula tip may enter either the left anterior descending or left circumflex artery. Any unperfused region of the left ventricle may be poorly protected during the procedure.
4.2. Calcified ostium
The coronary ostium as well as the surrounding wall of the coronary sinus of Valsalva may be rigid or irregular, occasionally making it difficult to selectively infuse cardioplegic solution into the coronary artery, because the cannula tip does not fit properly and there is significant leakage. When calcification accompanied by acoustic shadow is present adjacent to the coronary ostium (Fig. 9B), this pitfall may occur. A highly echogenic projection accompanied by acoustic shadow, usually on the side of the sinotubular junction, is a typical TEE finding. Calcification in the aortic root also makes it difficult to locate the right coronary ostium, especially when the sinus wall of Valsalva is rigid and cannot be folded back. Unsuccessful infusion of cardioplegic solution potentially leads to right heart failure, since the right coronary region cannot be adequately perfused via the retrograde approach. Although a large-bore cannula tip does not adequately fit the calcified ostium, a small-caliper cannula causes little leakage but the velocity of jet stream ejected out of the cannula can exceed 2 m/sec, potentially causing intimal damage or dissection. Fig. 9C shows the TEE findings of dissection that occurred in the left coronary artery following cardiopulmonary bypass in a case of difficult coronary perfusion. Although the left coronary artery was intact before bypass, no blood flow was detected during weaning from bypass in the area that was thought to contain the left main truncus. Since the anterior and posterior walls of the left ventricle were akinetic, immediate coronary bypass grafting to the left anterior descending artery was performed. Subsequent epicardial echo revealed a flap in the left main truncus and retrograde blood flow in the left anterior descending artery from the coronary bypass graft that perfused the left circumflex artery.
4.3. Anomalous origin of the right coronary artery
Anomalous origin of the right coronary artery is rather rare (Fig. 9D), but is difficult to diagnose based on preoperative coronary angiography. In a case of aortic stenosis with an intact right coronary artery in preoperative coronary angiography, the right coronary ostium could not be found in the right coronary sinus of Valsalva. Selective perfusion of the left coronary artery caused backflow from the right coronary ostium, which was identified at the commissure between the right and left coronary cusps. Calcified protrusion was continuous from the commissure to the ostium. The right coronary artery was successfully perfused, and the calcium at the orifice was left unresected. However, when calcium is exposed without being covered by the sewing ring, there is the potential for thrombus formation adjacent to the right coronary ostium. Following aortic valve replacement, TEE demonstrated that the stent post was located in front of the right coronary ostium, because the stent posts were oriented so that the left coronary ostium was not covered by the stent post. The right coronary artery coursed along the right coronary sinus and could have been inadvertently injured by the surgical procedures.
4.4. Myocardial perfusion during cardioplegia
Retrograde cardioplegia is a solution for difficult antegrade coronary perfusion. However, the region perfused by the right coronary artery is poorly protected because the cardioplegic solution predominantly enters the coronary veins along the left coronary artery (great cardiac vein) but not the middle or small cardiac veins. Although the latter may be perfused via collaterals between the veins, this is not certain. Also, in cases where it is difficult to fit the coronary perfusion cannula and there is considerable leakage, perfusion of the myocardium is a concern. A myocardial thermometer was conventionally used, but may not be useful in warm heart surgery. Real-time assessment of myocardial perfusion is desired, especially in cases with deteriorated cardiac function. Here, a novel method for noninvasively assessing myocardial perfusion is demonstrated (Fig. 10). The transgastric basal or midventricular short-axis view is visualized. In pulsed-wave Doppler mode, the sample volume is placed on the myocardium. When this portion of myocardium is perfused, a flow signal is detected. Under selective perfusion of the left coronary artery, blood flow is detected in the anterior wall but not in the inferior wall. As coronary perfusion is discontinued, the flow signal instantaneously disappears. The perfused region is identified by mapping the myocardium. This can be helpful for examining the extent of retrograde delivery of cardioplegic solution.
5. Assessment following implantation
After the aortotomy is closed, several pitfalls need to be checked (Fig. 11,12). If an unexpected event is detected, a prompt decision for additional intervention should be made.
5.1. Perivalvular or transvalvular leakage
During weaning from bypass, the surgeon should check for perivalvular leakage. A calcified aortic valve can result in inadequate contact between the annulus and the suture ring of the prosthetic valve. It is readily examined by TEE in the midesophageal long-axis view (Fig. 11A). A minor leak that originates inside of the ring and deviates inwards is transvalvular leak and is not significant (Fig. 11B). When significant leakage is detected in the left ventricular outflow tract that originates outside of the suture ring, perivalvular leakage is probable (Fig. 11C). The assessment of leakage is difficult in cases with concomitant mitral valve replacement. The ring of the prosthetic valve implanted in the mitral position casts an acoustic shadow on the left ventricular outflow tract (Fig. 11D). In such an instance, leakage is assessed in the deep transgastric long-axis view via the left ventricular apex (Fig. 11E).
Valve dysfunction should be checked during weaning from bypass. Dysfunction of a mechanical valve includes an immobilized disc at the open or closed positions. Since the disc itself is hardly depicted by TEE, dysfunction is examined in the color Doppler mode. In the short-axis view of the ascending aorta at the level just above the valve, opening of both discs can be confirmed by the flow signal, which fills the entire area of the aorta (Fig. 11F). Incompetence of the valve is caused by an immobilized disc of a mechanical valve at the open position probably due to debris or calcium between the disc and ring or by jammed leaflets of a bioprosthetic valve. It can be recognized by massive aortic regurgitation, demonstrated by a regurgitant jet in the left ventricular outflow tract originating from inside of the ring in midesophageal or deep transgastric view (Fig. 11G,H). In this case, exploration revealed that there was unintended eversion of a leaflet on the noncoronary side without jamming or leaflet damage. The leaflet was returned to the normal position and the aortotomy was closed [22].
5.2. Coronary ostium and ventricular contraction
Obstruction of coronary ostium is checked during weaning from bypass to minimize myocardial damage under warm ischemia. This event is important especially for the valve implanted in the supra-annular position. In the early timing following aortic declamping, patency and blood flow in both coronary arteries is checked. Both ostia can be visualized in the short-axis view just above the valve (Fig. 12A). In the midesophageal aortic valve long-axis view, the right coronary ostium is seen above the sewing ring (Fig. 12B). The presence of flow and distance from the ring of the prosthetic valve is checked.
Blood flow in the left coronary artery is examined proximal to its bifurcation into the LAD and LCX as shown in Fig. 8. Fig. 12D shows TEE views in a case of a low origin of the LMT. Before cardiopulmonary bypass, the midesophageal long-axis view showed a short distance between the aortic annulus and left main truncus. Following valve replacement at the intra-annular position, knots were found to be in front of the left coronary ostium and accelerated flow was seen. In the midesophageal long-axis view, the left coronary ostium was just above the ring. Surprisingly, the left main truncus was just behind the annulus. A deep suture could have injured the left main truncus. Fig. 12E and F demonstrate a case with a normal origin of the main left coronary artery. Before cardiopulmonary bypass, the coronary orifice was approximately 1 cm above the aortic annulus (Fig. 12E1,2). The 3D en face view clearly demonstrated an adequate distance (Fig. 12 E3). After replacement, TEE showed that there was no obstacle in front of the left main truncus in the short-axis view (Fig. 12F1). In the long-axis view, there was adequate distance between the ring and left main truncus (Fig. 12F2). 3D TEE also clearly showed safe implant of the prosthetic valve (Fig. 12F3). As ventricular contraction recovers, regional wall motion abnormalities can be assessed in the midesophageal, 2-chamber and 4-chamber views, or the transgastric basal or mid-short-axis views.
If coronary obstruction is suspected as in Fig. 9, early coronary revascularization is to be considered for minimizing myocardial damage. Ischemia can develop not only by obstruction of coronary ostium but by poor myocardial protection or embolism of dislodged calcium or even intracardiac air. Sustained circulatory support may be advantageous or retrograde cardioplegia may potentially help to displace any calcium or air embolus toward the coronary ostium.
5.3. New mitral regurgitation
Mitral regurgitation may appear following aortic valve replacement. One reason is perforation of the mitral annulus caused by excessive decalcification of the aortic annulus. Another mechanism is systolic anterior motion of the mitral leaflet, which is caused by reduced left ventricular dimensions and/or a sigmoid septum due to left ventricular hypertrophy. When several measures are not effective, emergent mitral valve replacement should be considered.
5.4. Aortic dissection
Following aortic declamping, the aorta distal to the clamp site should be checked for new dissection. It may potentially develop due to detachment of the calcified aortic wall, and inner or outer layer. Dissection can also originate from the arterial cannulation site, root cannula site or aortotomy site.
In conclusion, it is essential to watch for pitfalls in aortic valve replacement for calcified aortic valve, because it is commonly associated with various pathologies that can affect the surgical outcomes. Meticulous monitoring and intraoperative diagnostic imaging are helpful for achieving the best possible results in cases with increased risk factors.
Abbreviations for figures
A-AO ascending aorta
AML anterior mitral leaflet
AV aortic valve
LA left atrium
LAD left anterior descending artery
LCA left coronary artery
LCC left coronary cusp
LCS left coronary sinus
LMT left main truncus
LVOT left ventricular outflow tract
MV mitral valve
NCC noncoronary cusp
PA pulmonary artery
RA right atrium
RCA right coronary artery
RCC right coronary cusp
RCS right coronary sinus
R-PA right pulmonary artery
RV right ventricle
STJ sinotubular junction
SVC superior vena cava
References
- 1.
Early and late outcomes of aortic valve replacement in dialysis patients. Ann Thorac SurgTanaka K Tajima K Takami Y et al 2010 89 65 70 - 2.
Prevalence of atherosclerosis of the coronary and extracranial cerebral arteries in patients undergoing aortic valve replacement for calcified stenosis. J Heart Valve DisKaden J. J Eckert J. P Poerner T et al 2006 15 165 8 - 3.
Coronary embolism and calcified aortic valve: is there a correlation? J Thromb ThrombolysisStaico R Armaganijan L Lopes R. D 2012 , 34, 425-7. - 4.
Branch retinal artery embolization due to calcific aortic valve stenosis. Eur J OphthalmolMannino G Romano M Calanchini M Mannino C Cascone N. C 2010 20 625 8 - 5.
Stroke secondary to calcific bicuspid aortic valve: case report and literature review. J CardiolMahajan N Khetarpal V Afonso L 2009 54 158 61 - 6.
Evaluation of aortic root and valve calcifications by multi-detector computed tomography. J Heart Valve DisRivard A. L Bartel T Bianco R. W et al 2009 18 662 70 - 7.
Modification of surgical planning based on cardiac multidetector computed tomography in reoperative heart surgery. Ann Thorac SurgAviram G Sharony R Kramer A et al 2005 79 589 95 - 8.
Detachment of the mitral valve anterior leaflet as a complication of aortic valve replacement. Tex Heart Inst JIslamoglu F Apaydin A. Z Degirmenciler K et al 2006 33 54 6 - 9.
Intraoperative imaging in aortic valve surgery as a safety net (Chapter 1). IN: Motomura N, ed. Aortic Valve Surgery. InTech Co., Croatia,Orihashi K 2011 3 18 - 10.
Aortic valve replacement with 17-mm St. Jude Medical Regent prosthetic valves for a small calcified aortic annulus in elderly patients. Gen Thorac Cardiovasc SurgTaniguchi S Noguchi M Onohara D et al 2010 58 506 10 - 11.
Aortic root enlargement does not increase the surgical risk and short-term patient outcome? Eur J Cardiothorac SurgCoutinho G. F Correia P. M Paupério G et al 2011 40 441 7 - 12.
Stentless aortic valve implantation in heavily calcified aorta. J Cardiovasc Med (Hagerstown)Karimov J. H Cerillo A. G Solinas M et al 2009 10 813 4 - 13.
Di Matteo G Masala N, Swanevelder J, et al. Clinical outcome of a simplified technique for aortic valve replacement with stentless bioprostheses. J Heart Valve Dis2009 18 111 8 - 14.
Apicoaortic valved conduit with an apical connector for aortic stenosis with a calcified aorta. Gen Thorac Cardiovasc SurgShin H Mori M Suzuki R et al 2009 57 467 70 - 15.
Apico-aortic valved conduit as an alternative for aortic valve re-replacement in severe prosthesis-patient mismatch. Interact Cardiovasc Thorac Surg El-Chahine J. H Rassi I Jebara V 2009 9 680 2 - 16.
Is there a role for the left ventricle apical-aortic conduit for acquired aortic stenosis? J Heart Valve DisCrestanello J. A Zehr K. J Daly R. C et al 2004 13 57 62 - 17.
Surgical experience of ascending aorta and aortic valve replacement in patient with calcified aorta. Korean J Thorac Cardiovasc SurgChung S Park P. W Choi M. S et al 2012 45 24 9 - 18.
Deep hypothermic arrest for aortic valve replacement in case of porcelain aorta. Asian Cardiovasc Thorac AnnIliopoulos D. C Deveja A. R Satratzemis V et al 2009 17 415 6 - 19.
Aortic valve replacement in a heavily calcified "porcelain" aorta. Jpn J Thorac Cardiovasc SurgOkamoto H Fujimoto K Tamenishi A et al 2001 49 453 6 - 20.
Endovascular clamping of porcelain aorta in aortic valve surgery using Foley Catheter. Heart Lung CircOoi A Iyenger S Langley S. M et al 2006 15 194 6 - 21.
Aortotomy and endarterectomy of the ascending aorta for aortic valve replacement in a patient with porcelain aorta. Surg TodayKudo M Misumi T Koizumi K 2005 35 1000 3 - 22.
Everted leaflet of a bovine pericardial aortic valve. Interact Cardiovasc Thorac SurgOrihashi K Kurosaki T Sueda T 2010 10 1059 60