Cable parameters
1. Introduction
Since the erection of the Stromaund Bridge of Sweden in 1956, cable-stayed bridge, as an efficient and economic bridge type to surmount a long-distance obstacle, has attracted more and more interests both from bridge engineering community and from the society and government. Nowadays, the cable stayed bridge is the most competitive type for the bridge with the span of 300-1000 meters. For a cable supported bridge, which is generally quite flexible and of low damping, its vibration under ambient excitation (such as the wind and ground motion excitation) and operational loading (such as the vehicle and train loads) is quite critical for its safety, serviceability and durability. Vibration control countermeasures, such as the installation of the energy dissipating devices, are thus required [1, 2]. Structural active control, which applies a counter-force induced by a control device to mitigate structural vibration, has been widely proposed for the vibration control of cable stayed bridges and proven to be efficient by many researchers [3-6].
Although the vibration response of a fully erected cable-stayed bridge should be controlled, a cable-stayed bridge under construction, which is of low damping and not as stable as the completed structure, is generally more vulnerable to dynamic loadings. During the construction stage, the cable pylons were generally erected firstly and the cable and main girders are then hang on the pylons symmetrically in a double-cantilever way. With the increase of the cantilever length, the bridge is more and more flexible. When the girder is on its longest double-cantilever state, the bridge is the most vulnerable to the external disturbance (such as the ambient wind fluctuation and ground motions). Moreover, if the cables, pylons and main girder of the bridge are all steel components and thus the damping of the bridge is very low, its vibration under ambient excitations will be quite large. The vibration reduction countermeasures are thus in great demand. Frederic conducted several mock-up tests representing a cable-stayed bridge during the construction stage [7]. Since the control objective was set to reduce the girder vertical vibration response or cable parametric vibration response, the active tendon was installed as the control device. While for a cable stayed bridge under uncontrollable ambient excitations, structure will vibrate not only in the vertical direction but also in the transverse direction. Moreover, since the bridges are generally designed to carry the vertical loads, the unexpected transverse loads, especially the transverse dynamic loads, will induce structural safety and durability problems. It is thus of crucial importance to install some vibration reduction devices to control bridge transverse vibration. For this type of structure vibration control problem, the active mass damper (AMD) or the active tuned mass damper (ATMD) will be a competent candidate [8, 9].
In this chapter, the general procedure and key issues on adopting an active control device, the active mass damper (AMD), for vibration control of cable stayed bridges under construction are presented. Taking a typical cable stayed bridge as the prototype structure; a lab-scale test structure was designed and fabricated firstly. A baseline FEM model was then setup and updated according to the modal frequencies measured from structural vibration test. A numerical study to simulate the bridge-AMD control system was conducted and an efficient LQG-based controller is designed. Based on that, an experimental implementation of AMD control of the transverse vibration of the bridge model was performed.
2. Model structure description and vibration test
The lab-scale bridge model studied in this chapter is designed according to a prototype cable-stayed bridge, the Third Nanjing Yangtze River Bridge located in Jiangsu Province of China. Since the prototype bridge is of all the characteristics of a modern cable-stayed bridge, the test model is assumed to be a good test bed to study the feasibility of active structural control applied to cable-stayed bridges under construction. The test model was designed and fabricated to simulate the longest double cantilever state during the construction stage of the prototype bridge. Since structural dynamic response control is the main focus of this chapter, the test model is preliminarily designed according to the dynamic scaling laws. However, concerning the restriction of test conditions, some modifications were made during the detailed design of the model bridge [10]. Fig. 1 shows the dimension of the designed model bridge. The bridge is composed of a 1.433 meters high cable pylon, a 3.08 meters long main girder, and six couples of stay cables. The cross section of the main girder is a rectangular of 16 mm wide and 10 mm high. At two ends of the main girder, the 3.6 kg and 3.8 kg weight AMD orbits were installed on the side span and main span respectively. The stay cables are made of steel wire with the diameter of 1 mm. At the upper end of each cable, an original 30 cm long spring was installed and adjusted to simulate the cable force. The cable forces were adjusted to provide supporting force to the main girder and to force it to match the designed layout of the test bridge. Table 1 shows the length, Young’s Modulus and computed cable force for the cables. All of the components were made of steel. Since the model consists of only one cable pylon and no other piers, it is symmetric with respect to the cable pylon.
Cable No. | 1# | 2# | 3# |
Young’s Modulus (Mpa) | 451.7 | 327.0 | 216.0 |
Length with spring (m) | 1.62 | 1.17 | 0.77 |
Spring Force (N) | 32.0 | 13.9 | 7.2 |
Num. | 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 |
Sensitivity (mv/g) | 134.6 | 140.8 | 127.4 | 134.6 | 149.2 | 138.3 | 138.5 | 130.8 |
Location (m) | 0.06 | 0.32 | 0.62 | 1.02 | 2.06 | 2.46 | 2.76 | 3.02 |
Vibration tests under forced excitations were conducted to identify the dynamic characteristics of the bridge model. Eight accelerometers (as described in Table 2) were distributed along the main girder both on the side span and the main span to collect structural acceleration responses at a sampling frequency of 50 Hz (as shown in Fig. 2a). A transverse impulse force was acted on the cantilever end of the side span to excite the structure. Concerning that the bridge model is symmetrical about the cable pylon and thus of repeated or close frequency modes, a modal identification algorithm of the capacity to identify the close modes, the wavelet based modal identification method developed by the research group, is used [11]. During the analysis, the mother wavelet function adopted is the complex Morlet function with the central frequency of 300 Hz and the scale increment is set to be 0.25 during the analysis. Fig. 2b shows the wavelet scalgram of a set of response measurement on the tip end of the side span. As shown in the figure, structural transverse vibration responses were dominated by two modes at the scale of 168.0 and 176.5, which correspond to the vibration modes of the natural frequencies of 1.701 Hz and 1.786 Hz, respectively. This figure also shows that the adopted modal identification method can separate these two close modes successfully. Structural modal parameters can then be estimated and the results are shown in Table 3.
3. Numerical modeling and model updating
For structural active control, a baseline numerical model is generally required for controller design. A FEM bridge model is thus setup in ANSYS according to the design diagram of the bridge model. The cable is modeled using a 3D uniaxial tension-only truss element. Equivalent modulus for the cables without spring are computed using Ernst formula and then series wound equivalent modulus for the cable with spring can be established. Other structural elements are all modeled using 3D elastic beam element. Cables are connected to the main girder using rigid beam element. Additional masses were modeled using isotropic mass element. The cable pylons and the main girder are linked by coupling the horizontal projective intersection points of the lowest transverse beam of the pylon with the main girder. The six DOFs at the feet of the pylon are fixed.
The first transverse symmetrical bending (TSB) mode | The first transverse anti-symmetrical bending (TAB) mode | ||
Frequency | Test | 1.701 Hz | 1.786 Hz |
Initial Model | 1.848 Hz | 1.856 Hz | |
Updated Model | 1.787 Hz | 1.786 Hz | |
Mode Shape | Test | [1.00 0.86 0.70 0.32 0.00 0.30 0.70 0.90 0.99] | [1.00 0.84 0.72 0.28 0.00 -0.32 -0.70 -0.86 -0.99] |
Initial Model | [1.00 0.74 0.46 0.17 0.00 0.13 0.38 0.60 0.81] | [1.00 0.74 0.47 0.17 0.00 -0.14 -0.38 -0.60 -0.81] | |
Updated Model | [1.00 0.74 0.46 0.17 0.00 0.17 0.46 0.74 1.00 | [1.00 0.74 0.46 0.17 0.00 -0.17 -0.46 -0.74 -1.00] | |
MAC* | Initial Model | 0.9620 | 0.9620 |
Updated Model | 0.9722 | 0.9718 |
Taken eigenvalue analysis of the numerical model, structural natural frequencies and mode shape vectors can be computed. Table 4 shows the computed modal parameters of the transverse bending modes. As shown in the table, since the sum of the effective mass of the first transverse anti-symmetric bending mode (TAB) and the first transverse symmetric bending mode (TSB) is 80.1% of the sum of the effective mass of all transverse modes, these 2 transversal modes dominant the transverse vibration of the bridge. Fig. 3 shows the mode shape of these two transverse bending modes.
No. | Frequency (Hz) | Mode description | Effective mass (kg) |
1 | 1.848 | The first TAB mode | 6.00 |
2 | 1.856 | The first TSB mode | 6.00 |
3 | 19.802 | The second TAB mode | 0.94 |
4 | 19.848 | The second TSB mode | 0.94 |
Comparing the natural frequencies obtained from the eigenvalue analysis on the numerical model and the vibration test on the test bridge, some differences can be observed (as shown in Table 3). A model updating process is thus conducted to get an accurate baseline numerical model. The results of the sensitivity analysis show that the vertical and transverse vibration modes are sensitive to the tip mass magnitude, while the Young’s module of the cable is critical for vertical bending modes. So these two parameters were updated: the tip masses of two spans were updated from 3.8kg and 3.6kg to 4.16kg, respectively, and the spring modulus was updated from 220N/m to 203N/m. Table 4 shows the natural frequencies and mode shapes of the updated model. As shown, the modal parameters of the first TSB and TAB modes have a good match with the modal test results.
4. Control system simulation
Based on the baseline numerical model updated according to dynamic measured structural modal parameters, a system simulation study is conducted. For a bridge-AMD system, its governing equation of motion is
where,
Since the numerical model of a complex structure is generally of a large amount of DOFs, for example in this study the FEM model obtained from the last section is of 1188 DOFs, this will induce great computation difficulty to design the controller according to this so called full order model. A reduced order model is thus required. In this study, the critical modal reduction method is adopted for this purpose because this method can greatly reduce structural DOFs and the reduced order model is of clear physical meaning [12, 13]. Concerning a structure whose vibration is dominated by the first
where,
For this reduced order bridge-AMD system, its state space equation is
where,
where
The control output and observer output matrices
5. Controller design
The design of a controller is very important for the success of structural active vibration control. In this study, the
where
To obtain a good controller for experimental implementation, a series of numerical analysis with different value of weight parameter
To simulate a more practical control condition during experimental implementation, the following constraint condition is adopted: 1) The discrete digital computation is employed for the controller computation with the sampling frequency of 500Hz; 2) The precision of the A/D converter is set to be 12-bits and the range of the input voltage is set to be
For S1 control, a series of numerical studies simulating the control system with one AMD cart installed on the tip end of the main span of the bridge, whose actuation force is expressed as Eq. (10), are conducted when the weighting parameter
For S2 control, the control system with two AMD carts, whose actuation force expressions are shown as Eq. (10) and (11), installed on the tip ends of both spans of the bridge, is simulated. Numerical studies are conducted when the weighting parameter
The control performance comparison of these two AMD placing strategies tell that for the cable-stayed bridge studied, which is of two dominant transverse vibration modes with close frequencies, the single AMD control strategy (S1) can only reduce structural vibration response of the AMD-instrumented span, and the double AMD control strategy (S2) can achieve a good control performance for reducing structural response of both spans. These observations are verified by checking the controllability criteria. If the control system is of two close eigenvalues, at least two actuators are required to ensure the system is controllable. Moreover, since structural dominant transverse modes are anti-symmetric and symmetric bending modes, the shift of the AMD position along one span of the bridge will only proportionally vary the coefficients of
6. Experimental implementation
To verify the feasibility of the AMD control for transverse vibration reduction of cable-stayed bridge under construction, an experimental study on the fabricated test model is conducted in the Bridge Testing Laboratory of Tongji University. During the experiment, the S2 control strategy was adopted according to the conclusion obtained from the above numerical simulation study. Fig. 8 shows the layout of the experimental setup. As shown in the figure, the control system includes a data acquisition system, a central control computer, and two AMD carts. The data acquisition system consists of eight accelerometers, whose sensitivity is checked using dynamic calibration method; Dspace signal amplifier and filter; a general purpose data acquisition and control board MultiQ-3, which has 8 single ended analog inputs, 8 analog outputs, 16 bits of digital input, 16 bits of digital output, 3 programmable timers and up to 8 encoder inputs decoded in quadrature (option 2E to 8E). The central control computer is of 512 Mb memory and 1.0 GHz Intel Celeron processor. The
AMD carts (as shown in Fig. 8) are electric servo type [16]. They are 0.645 kg weight. Their track length is 32 cm and the max safe input voltage is
During the experiment, the tip ends of the main girder were pulled transversely using steel wires firstly to generate an initial displacement in this direction. The wires were then cut suddenly and the bridge started to vibrate due to this initial potential energy imported. Several seconds later, the power of the AMD control system was turned on and structural vibration response was recorded. Three case studies were conducted to check the performance of the AMD control system under different excitation schemes. For the first case, case C1, the tip ends of both the main span and the side span were pulled in the same direction. After the steel wires were cut, the transverse symmetric bending mode of the bridge was excited. For case C2, the tip ends of the two spans were pulled in the opposite direction to excite the transverse anti-symmetric bending mode of the bridge. Case C3 simulated bridge free vibration under an initial displacement of the main span. Both anti-symmetric and symmetric transverse bending modes of the bridge would thus be excited.
For test case C1, Fig. 9 shows the AMD driving voltage, recorded tip acceleration responses with or without AMDs, and their Fourier spectrums. As shown in these figures, when the power of the AMD carts was still turned off, structural acceleration responses were already reduced. When the power is turned on, the free decay ratios of structural responses were further increased. That verifies the performance of the active control system on structural response reduction. The comparison of the uncontrolled and AMD controlled Fourier spectrum magnitude of structural responses also verifies this statement. Moreover, as shown, when the AMD carts were installed, the peaks of Fourier spectrum were shifted to the left-hand-side, which meant that the natural frequencies of the system were decreased. Table 5 shows the peak and RMS acceleration response of the structure with and without AMD. As shown in the table, after the AMD was mounted, the peak and RMS accelerations recorded at the tip point of the side span were reduced 44.1 % and 82.1 %, respectively. For the tip point of the main span, the recorded peak and RMS accelerations were reduced 31.1 % and 81.4 %, respectively. For test cases C2 and C3, the peak and RMS acceleration responses of the structure with and without AMD were recorded. As shown in Table 5, the transverse vibration responses for these sensor-mounted points were also efficiently reduced: For case C2, structural peak and RMS acceleration responses were respectively reduced 28.3% and 65.4% for the tip point of the side span and 22.0% and 68.4% for the tip point of the main span; For case C3, structural peak and RMS acceleration responses were reduced 65.8% and 85.6% respectively for the tip point of the side span and 40.5% and 76.7% for the tip point of the main span. Moreover, concerning that the controller is designed via numerical studies on a reduced order model, the good control performances obtained on the bridge model tells that the control algorithm adopted in this study is of good robustness.
Case | Peak acc. of sensor 1 | RMS acc. of sensor 1 | Peak acc. of sensor 8 | RMS acc. of sensor 8 | ||||
No AMD | With AMD | No AMD | With AMD | No AMD | With AMD | No AMD | With AMD | |
C1 | 4.431 | 2.479 | 1.826 | 0.326 | 4.312 | 2.970 | 1.810 | 0.336 |
C2 | 4.198 | 3.012 | 1.341 | 0.464 | 3.563 | 2.779 | 1.327 | 0.419 |
C3 | 5.186 | 1.773 | 1.800 | 0.260 | 5.833 | 3.473 | 1.820 | 0.424 |
7. Concluding remarks
In this chapter, the active mass dampers are implemented for vibration control of a lab-scale cable stayed bridge in double cantilever construction state. The results of both numerical simulation and experimental study verified that the proposed AMD control technique is applicable and efficient for the control of transverse vibration of cable-stayed bridge under construction.
For the cable-stayed bridge studied in this chapter, structural vibration test showed that the bridge was of two dominant transverse bending modes with close frequencies. The numerical study verified that for the control of such a structure with repeated frequencies; at least two AMDs should be installed for a good control performance. Moreover, the placement of those two AMDs should be carefully studied.
For the control of a linear, time-invariant system, an accurate and complete system models are generally required. However, for the bridge-AMD system studied in this chapter, it is very difficult, if not impossible, to set up such a numerical model due to the complex layout of the bridge structure. Since structural vibration responses are generally governed by some dominant vibration modes and the objective of structural vibration control is to reduce but not to completely restrain structural vibration responses, this study verified that a reduced order model constructed from the critical modes is good enough for the controller design to achieve an excellent vibration reduction performance. Considering the differences between the numerical model and the real structure, the control algorithm adopted in this study must be robust to the vibration property change of the controlled structure. The results of experimental studies show that the vibration of the test model can be well controlled using the controller designed from the numerical studies. That means the
This study is an initial work on AMD control of transverse vibration of a cable stayed bridge under construction before it can be used for real applications. Although the experimental study verified the efficiency of the adopted AMD control for structural response reduction under given excitation, some primary issues for real application of the AMD control technique, such as how to deal with time delay, how to reduce the requirement on power supply of the control system, and et al., are not addressed in this study. Further laboratory studies or field applications on some real bridges will be conducted in the coming future to discuss these issues and make the technique more efficient and practical for real applications.
Acknowledgement
This research is partially supported by the National High-tech R&D Program of China (863 Program) (Grant No. 2006AA11Z109), and Shanghai Rising Star Tracking Program (Grant No. 09QH1402300). These supports are greatly appreciated.
References
- 1.
Boonyapinyo V. Aksorn A. Lukkunaprasit P. 2007 Suppression of aerodynamic response of suspension bridges during erection and after completion by using tuned mass dampers. Wind and Structures, An Int\’l Journal,10 1 1 22 - 2.
Ubertini F. 2010 Prevention of suspension bridge flutter using multiple tuned mass dampers. Wind and Structures, An Int\’l Journal,13 3 235 256 - 3.
Warnitchai P. Fujino Y. Pacheco B. M. Agret R. 1993 An experimental study on active tendon control of cable-stayed bridges. Earthquake Engineering and Structural Dynamics,22 93 111 - 4.
Achkire Y. Preumont A. 1996 Active tendon control of cable-stayed bridges. Earthquake Engineering and Structural Dynamics,25 6 585 597 - 5.
Dyke S. J. Caicedo J. M. Turan G. Bergman L. A. Hague S. 2003 Phase I benchmark control problem for seismic response of cable-stayed bridges. Journal of Structural Engineering, ASCE,129 7 857 872 - 6.
Caicedo J. M. Dyke S. J. Moon S. J. Bergman L. A. Turan G. Hague S. 2003 Phase II benchmark control problem for seismic response of cable-stayed bridges. Journal of Structural Control,10 137 168 - 7.
Frederic B. Andre P. 2001 Active tendon control of cable-stayed bridges: a large-scale demonstration. Earthquake Engineering & Structural Dynamics,30 961 979 - 8.
Shelley S. J. Lee K. L. Aksel T. Aktan A. E. 1995 Active control and forced vibration studies on highway bridges. Journal of Structural Engineering, ASCE,121 9 1306 1312 - 9.
Korlin R. Starossek U. 2007 Wind tunnel test of an active mass damper for bridge decks. Journal of Wind Engineering and Industrial Aerodynamics,95 267 277 - 10.
Chen H. 2007 Experimental study on active control of cable-stayed bridge under construction. Master Thesis. Tongji University. - 11.
Sun Z. Hou W. Chang C. C. 2009 Structural system identification under random excitation based on asymptotic wavelet analysis. Engineering Mechanics, 26(6), 199-204 (in Chinese). - 12.
Schemmann A. G. 1997 Modeling and active control of cable-stayed bridges subject to multiple-support excitation. PhD thesis. Standford University. - 13.
Xu Y. Chen J. 2008 Modal-based model reduction and vibration control for uncertain piezoelectric flexible structures. Structural Engineering and Mechanics,29 5 489 504 - 14.
Laub A. J. Arnold W. F. 1984 Controllability and observability criteria for multivariable linear second-order models, IEEE Transactions on Automatic Control, AC-29(2). - 15.
Wu J. C. Yang J. N. Schmitendorf W. E. 1998 Reduced-order H∞ and LQR control for wind-excited tall buildings. Engineering Structures.20 3 222 236 - 16.
Quanser Consulting Inc. 2002 Active Mass Damper: Two-Floor (AMD-2), User Manual.