iOCT in PVR Surgical Management

By Salvatore Di Lauro, Salvador Pastor Idoate and Jose Carlos Pastor

Submitted: January 19th 2018Reviewed: May 17th 2018Published: November 5th 2018

DOI: 10.5772/intechopen.78774

Downloaded: 137

Abstract

Recent advances in optical coherence tomography (OCT) technology have allowed the introduction of OCT into the operating room. Intraoperative OCT (iOCT) has been utilized to visualize the retinal architecture prior, during, and following several retinal surgical technics. The identification of epiretinal, subretinal, and intraretinal changes is one of the crucial points in PVR management. The iOCT can identify intraretinal changes and/or subretinal PVR membranes which cannot be easily peeled as epiretinal membranes. Intraretinal forms are especially difficult to identify preoperatively but their presence may be crucial in surgical management because the attempt to remove the presumed membrane may result in severe retinal tissue damage and iatrogenic tears. Therefore, surgical technique and even tamponade choice may be seriously affected by OCT imaging results.

Keywords

  • OCT
  • intraoperative OCT
  • PVR
  • retinal detachment
  • vitreo-retinal surgery

1. Introduction

Optical coherence tomography (OCT) has dramatically changed the diagnosis, classification, and treatment of many vitreo-retinal diseases [1, 2, 3]. One of the most recent developments of this technology is the intraoperative OCT (iOCT). The iOCT allows a real-time tomographic visualization of the retina without the need to stop the surgery and without any external machines (microscope-integrated OCT). In this way, the surgeon can see OCT images during the surgery on an external display or directly through the microscope.

iOCT adds microscopic information and visualizes sub-surface structures in a non invasive way. This information can impact surgical decision-making as well as surgical maneuvers in selected cases. In this sense, the intraoperative visualization of the retina opens new surgical and diagnostic possibilities. Vitreo-retinal interphase diseases may especially benefit from iOCT spreading but also retinal detachment (RD) surgery could be positively affected.

Proliferative vitreoretinopathy (PVR) is one of the most severe complications after RD, appearing in 5–10% of them [4]. Despite recent advances in vitreo-retinal surgery, PVR management is still an unsolved issue [4]. The introduction of the iOCT in surgical practice could be useful in improving the management of this important complication.

2. Intraoperative optical coherence tomography (iOCT)

The iOCT is a relatively new technology, and the first relevant study about iOCT applications in ophthalmology was the so named Prospective Intraoperative and Perioperative Ophthalmic Imaging with Optical Coherence Tomography (PIONEER) study [5]. The 2-year results published in 2014 demonstrated the potential advantages and applications of this technology [5]. Nevertheless, in this study, an external OCT system mounted on the operative microscope (Bioptigen SDOIS portable spectral-domain OCT [SD OCT] system; Bioptigen, Research Triangle Park, North Carolina, USA) was used. The most serious inconvenience of this system was the need to pause the surgery to obtain the required images.

Since this study, relevant advances in this technology have been reached to obtain a real microscope-integrated technology. Actually, there are several iOCTs available, including RESCAN 700 (Carl Zeiss Meditec, Inc., Oberkochen, Germany), the EnFocus (Bioptigen/Leica Microsystems, Wetzlar, Germany), and an integrated prototype internally developed at the Cole Eye Institute, Cleveland Clinic Foundation (Cleveland, Ohio) [6]. All these systems allow a real-time OCT imaging during the surgery and provide instantaneous feedback to the surgeon.

The PIONEER and the Determination of Feasibility of Intraoperative Spectral-Domain Microscope Combined/Integrated OCT Visualization during En Face Retinal and Ophthalmic Surgery (DISCOVER) studies have largely demonstrated the iOCT usefulness in the anterior and posterior segment surgery [5, 6]. Surgical procedures and pathologies positively affected by iOCT introduction in surgical practice include Descemet stripping automated endothelial keratoplasty (DSAEK), Descemet membrane endothelial keratoplasty (DMEK), pars plana vitrectomy for epiretinal membrane, proliferative diabetic retinopathy (PDR), rhegmatogenous retinal detachment, macular hole, optic pit maculopathy, chorioretinal biopsy, and Argus (Second Sight Medical Products, Inc., Sylmar, CA) prosthesis implant [5, 6, 7, 8, 9, 10, 11, 12, 13]. The DISCOVER study’s 3-year results have been recently published [6]. A total of 837 eyes (244 anterior segment/593 posterior segment cases) were included and iOCT successful image acquisition was achieved in 820 eyes (98.0%; 95% confidence interval (CI), 96.8–98.8%). In 43.4% of the anterior segment cases (95% CI, 37.1–49.9%) and 29.2% (95% CI, 25.5–33.0%), the surgeons considered that the iOCT information impacted their surgical decision-making and altered the previous related procedure. Thus, iOCT could be considered a useful technology for ophthalmic surgery. Nevertheless, there are some limitations. The RESCAN 700, the commonest iOCT, is a SD-OCT system with scanning speed of 27,000 A-scans per second, with a wavelength of 840 nm, refresh rate from 5 to 50 Hz, axial resolution of 5.5 μm in tissue, scan depth of 2 mm, and scan length of 6 mm (adjustable from 3 to 16 mm). This means that image quality is still far away from the OCT currently used in clinical practice with axial resolutions of 1 μm and scanning speed of 400,000 A-scans per second. Furthermore, the autofocus and tracking mechanism must be improved to be faster and more accurate. Other limitations include artifacts, instrument shadow during surgery, and function overload with the surgical microscope pedal [6]. Instrument shadow is an important problem limiting the possibility of viewing retinal tissues immediately below the surgical instrument and is related to OCT image caption properties and the materials currently used in vitreo-retinal surgery (Figure 1). Nevertheless, new non-metallic instruments made from “OCT-friendly” materials, such as silicone, polycarbonate, and PVC, may allow one to diminish this problem, especially important in vitreo-retinal interface procedures [14, 15]. A valid alternative could be the use of OCT-integrated surgical instruments [14].

Figure 1.

Instrument shadow during intraoperative OCT (iOCT) imaging. Note the shadow (arrow) below the vitreotome probe. Image obtained with the Zeiss Rescan® 700 iOCT (Carl Zeiss Meditec, Oberkochen, Germany).

3. Proliferative vitreoretinopathy (PVR)

PVR is a complex process involving several risk factors, most of them still unknown. During the last 25 years, and despites the enormous advantages in vitreo-retinal surgery techniques, such as small-gauge instrumentation and new imaging technology, PVR incidence is unchanged and functional and anatomical results are still very poor. PVR is a complex and multifactorial disease, and pharmacological strategies (including anti-inflammatory drugs, antiproliferative agents, antineoplastic, antigrowth factors, and antioxidants) have been considered ineffective and they have been basically abandoned in current practice. Its pathogenesis is divided into several steps: migration of cells, mostly retinal pigment epithelial (RPE) and glial cells; proliferation of these cells; membrane development; contraction of the fibrocellular membrane; extracellular collagen production; and creation of fixed folds in the retina [4]. Several cytokines, growth factors, and single-nucleotide polymorphisms in genes related with inflammation and apoptosis have shown to have a crucial role in PVR development [4, 16, 17, 18, 19, 20, 21, 22, 23, 24]. The histopathology of the disease is characterized by various grades of fibrocellular membrane proliferation with prominent Muller cell activation. These phenomena result in complete retinal architecture alteration with a loss of normal retinal cell organization and function. These membranes may be epi-, intra- or sub-retinal. One of the crucial points is a correct and widely accepted classification which must include intraretinal status [4, 25]. In fact, PVR is characterized by epiretinal, subretinal but also intraretinal proliferation [4, 26, 27]. Intraretinal membranes are especially important because there is no way to remove them during surgery [4], and this increases the risk of surgical failure due to the retinal shortening. Intraretinal PVR must be considered the most severe form in which changes affecting retinal architecture lead to significant dysfunction. Epiretinal or subretinal membranes can be quite easily removed during surgery but intraretinal forms are an unsolved problem. In this sense, iOCT may be awfully valuable in surgical practice allowing the intraoperative assessment of retinal status. The iOCT may be useful to identify intraretinal changes and/or subretinal PVR membranes which cannot be removed with standard techniques (Figure 2). This means that it allows a better PVR classification and this can change our surgical attitude intraoperatively for better decision-making about a surgical technique. In fact, trying to remove the presumed membrane can have as consequences severe retinal injury and iatrogenic tears. Thus, surgical technique and even tamponade choice may be seriously affected by iOCT imaging.

Figure 2.

Intraoperative OCT (iOCT) in PVR. iOCT allows intraretinal changes identification (arrows). These membranes cannot be surgically removed. Image obtained with the Zeiss Rescan® 700 iOCT (Carl Zeiss Meditec, Oberkochen, Germany).

© 2018 The Author(s). Licensee IntechOpen. This chapter is distributed under the terms of the Creative Commons Attribution 3.0 License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.

How to cite and reference

Link to this chapter Copy to clipboard

Cite this chapter Copy to clipboard

Salvatore Di Lauro, Salvador Pastor Idoate and Jose Carlos Pastor (November 5th 2018). iOCT in PVR Surgical Management, OCT - Applications in Ophthalmology, Michele Lanza, IntechOpen, DOI: 10.5772/intechopen.78774. Available from:

chapter statistics

137total chapter downloads

More statistics for editors and authors

Login to your personal dashboard for more detailed statistics on your publications.

Access personal reporting

Related Content

This Book

Next chapter

Clinical Use of OCT in the Management of Epiretinal Membranes

By Nur Acar

Related Book

First chapter

Evidence of Oxidative Stress Damage in Glaucoma

By Sandra M Ferreira, Claudia G Reides, Fabián S Lerner and Susana F Llesuy

We are IntechOpen, the world's leading publisher of Open Access books. Built by scientists, for scientists. Our readership spans scientists, professors, researchers, librarians, and students, as well as business professionals. We share our knowledge and peer-reveiwed research papers with libraries, scientific and engineering societies, and also work with corporate R&D departments and government entities.

More about us