Open access peer-reviewed chapter

The Use of Electrical Measurements of Wind Turbine Generators for Drive Train Condition Monitoring

By Estefania Artigao, Andrés Honrubia-Escribano, Sergio Martín-Martínez and Emilio Gómez-Lázaro

Submitted: February 12th 2019Reviewed: October 14th 2019Published: April 15th 2020

DOI: 10.5772/intechopen.90127

Downloaded: 48

Abstract

More modern and larger wind turbine (WT) generators are under continuous development. These exhibit more faults than smaller ones, which becomes critical offshore. Under this framework, operation and maintenance (O&M) is the key to improve reliability and availability of WTs, where condition-based maintenance (CBM) is currently seen as the preferred approach by the early detection and diagnosis of critical faults for WTs. The induction generator is one of the biggest contributors to failure rates and downtime of WTs, together with the gearbox and the drive train. In the present chapter, current signature analysis (CSA) will be introduced as a means for fault detection of WTs. CSA is a cost-effective and nonintrusive technique that can monitor both mechanical and electrical faults within the induction generator, as well as bearing- and gearbox-related faults. Different test cases of in-service wind turbine generators will be used to illustrate its usefulness.

Keywords

  • condition monitoring
  • current signature analysis
  • DFIG
  • wind turbine
  • operation and maintenance
  • predictive maintenance
  • drive train

1. Introduction

Wind energy is currently the most mature, cost competitive and cost-efficient source of renewable energy. This has been proven through the levelized cost of electricity (LCOE), which is a very common measure to define the cost of any sort of electricity generation. The historical evolution of onshore and offshore wind LCOE is shown in Figure 1. As can be seen, the LCOE has continuously decreased during the past few years both for onshore and offshore wind power generation. Offshore wind has experienced a bigger drop than onshore, although it still shows a significantly higher LCOE.

Figure 1.

Evolution of the LCOE for global onshore and offshore wind energy generation from 2010 to 2018.

With over 590 GW of wind power installed globally, the market intelligence of the Global Wind Energy Council (GWEC) expects over a 55 GW per year global increment of new installations (combining both offshore and onshore wind) until 2023 [1]. In the present scenario, China leads the onshore sector, followed by the USA, Germany, India and Spain. The offshore sector is led by the UK, followed by Germany and China. The distribution of the top 10 countries with onshore wind power installed and the top 3 for offshore installations can be seen in Figure 2.

Figure 2.

Distribution of cumulative installed onshore and offshore wind energy capacity.

1.1 Reliability and availability

New sophisticated multi-MW wind turbines are constantly being developed [2, 3, 4], both for onshore and offshore applications [5]. Such rapid growth entails significant challenges that need attention from researchers and the industry [6]. In fact, more failures have been observed in large wind turbines than the small ones [7, 8, 9]. Current availability figures for onshore and offshore wind farms are found to be 97 and 85%, respectively [10, 11]. Accessibility issues and higher uncertainty are the reasons for the lower availability of offshore than the onshore.

Understanding which components are the most critical of a WT is the key to develop specific condition monitoring (CM) systems that will enhance O&M of wind farms, thus reliability and availability of WTs. To this end, this section presents the results published in the main failure rate and downtime surveys conducted in Europe, the USA and China. The major characteristics of these studies are summarised in Table 1, and the failure rate and downtime results presented in Figure 3.

SurveyYearLocationWT numberWT capacityOn-/offshore
AcronymPublished[MW]
AWE [12]2016Europe2270(av)1–3Onshore
CWEA [13]2016China
CARR [14]2015Europe3502–4Offshore
B&W [15]2014UK2.3Onshore
CREW [16]2013USA800–9001.3–1.4
EZ [17]2012Netherlands363Offshore
RELI [18]2011Europe350>0.8Onshore
VTT [19]2010Finland720.2–2.3Onshore
LWK [8]2008Germany158–6430.2–2Onshore
WSDK [20]2007Denmark851–23450.1–2.5Onshore
WSD [20]2007Germany1295–42850.1–2.5Onshore
SW [7]2007Sweden624(av)0.5–1.5Onshore
WMEP [9]2006Germany>1500Onshore

Table 1.

Characteristics of the main wind turbine reliability and availability surveys conducted in Europe, the USA and China.

Figure 3.

Failure rates and downtime of several wind turbine reliability and availability studies spread in Europe, the USA and China.

As can be seen in Figure 3, both the electric and the control systems show the largest percentages for failure rates across the different studies (up to 32 and 42%, respectively) while hub and blades and gearbox for downtime (up to 38 and 56%, respectively). Medium percentages of failure rates and downtime are obtained for the generator, pitch and hydraulic systems. The braking system and drive train present low failure rates but medium-to-high downtime. The sensors and structure categories present low values for both failure rates and downtime. Without considering the others category, the main contributors to failure rates across the different studies are hub & blades, electric, control and pitch systems. Similarly for the downtime, these are the gearbox, generator, mechanical brake and electric system assemblies.

If the main contributors both to failure rates and downtime are considered, then the control system, gearbox, electric system, generator and hub and blades could be considered the most critical components of wind turbines. Thus, special attention should be given to these components with regard to condition monitoring and O&M.

1.2 Operations and maintenance

One of the main leading costs of the wind farm’s total expenditure belongs to O&M activities [12], representing between 25 and 35% for onshore and offshore wind farms, respectively, of their lifetime costs [21, 22, 23]. It is thus clear that reducing O&M costs would be beneficial for wind farm owners and operators.

Maintenance strategies can be typically classified as [21, 24] time-based (TBM), failure-based (FBM) and condition-based. TBM is formed by preventive tasks, also referred to as scheduled maintenance, and it is carried out regardless of the health state of the WT. FBM involves corrective actions, only performed after a critical failure has taken place, thus usually causing long downtime periods. CBM, on the other hand, is a predictive type of maintenance. CBM takes place only when there is a need but before a critical failure occurs, with the consequent saving in resources and downtime, thus achieving the optimum strategy [25, 26]. The different maintenance strategies are illustrated in Figure 4. Traditionally, a combination of TBM and FBM has been the preferred option among wind farm operators [17]. Lately, however, the trends are shifting towards CBM, which is performed through appropriate condition monitoring, recognised by [27, 28] as the key for optimised reliability and availability of wind turbines while achieving cost reduction in O&M [29, 30].

Figure 4.

Maintenance strategies.

1.3 Condition monitoring

CM consists of analysing different types of signals (such as temperature, vibrations, electrical measurements, etc.) with the aim of assessing the health of the component under study [24] towards calculating its remaining useful life (RUL) [31]. In this context, the implementation of CM systems must enable early-stage fault detection, so that CBM can be implemented, thus significantly reducing or even eliminating unscheduled (or unplanned) maintenance costs [32, 33]. Many CM and fault diagnosis reviews have been published in the last 15 years that include the latest CM methods [34, 35]. These can be classified per WT subsystem [36, 37] and differentiated between structural [38], mechanical [39], power electronics and control systems [40] or electrical parts [41, 42, 43].

Current commercial CM systems mainly target the WT drive train (particularly the gearbox) and are based on vibrations and oil analysis. The first ones to appear, and therefore the most common, were based on oil analysis. These systems, in addition to providing information on the status of the oil, are also capable to inform about the gears. They detect ferrous and non-ferrous particles, where the presence of ferrous particles is indicative of gear wear, while the presence of non-ferrous particles indicates oil degradation. Soon, a lot of research emerged based on vibration analysis, targeting the gearbox and bearings in the drive train. This type of analysis was adapted from other industries with rotating machinery. The latest commercial CM systems to appear were based on SCADA data. There are a large number of scientific publications utilising different parameters acquired by the SCADA system able to provide information of several components of the WT [44, 45]. Less common CM systems are based on acoustic emissions, strain gauges, thermographic analysis, etc.

On the other hand, with a non-negligible number of world-wide wind farms reaching the end of their expected 20-year lifetime [46], the field of lifetime extension (LTE) of wind turbines is gaining attention, where CM will also play a key role [47]. Different approaches are found for LTE of WTs such as practical inspections, field data analyses or analytical simulations. The authors in [48], for example, have identified data-driven approaches as the most cost-effective with large number of WTs.

1.4 Motivation

Data collection and analysis is not straightforward. There are many different techniques for signal processing and feature extraction, and, to date, no agreement has been established on which CM system is the most appropriate for specific components or assemblies. Furthermore, most of the techniques and methods developed for CM of WTs have only been applied on laboratory benches. In fact, with regard to the generator, despite being one of the most critical components in a WT, no commercial CM system has yet been developed that can provide exhaustive information about its health status.

The goal of the present chapter is to present a CM method based on electrical measurements that can detect different generator faults and has been implemented on in-service operating WTs. CM methods based on electrical measurements can be performed using current, voltage, instantaneous power and flux analyses [49]. Of these, stator current spectral analysis (Current Signature Analysis, CSA) is recognised as the preferred option [50, 51, 52], thus chosen for this book chapter.

2. The method: current signature analysis

CSA is a nonintrusive method capable of identifying electrical and mechanical faults in a cost-effective manner [53, 54, 55]. It is based on the principle that different faults have different effects on the current spectra. It can be implemented on doubly-fed induction generators (DFIGs), which are the most common technology on variable speed WTs.

As reported in [56], bearing-related faults are the most common in WT generators, representing 59% of the total share, followed by stator faults with 28% and then rotor faults with 9% (the remaining 4% assigned to ‘others’). These faults produce excessive heating, flux unbalance, voltages and/or phase current unbalance, decreased average torque, etc., thus negatively affecting the generator’s efficiency [57]. Fault frequency components related to such faults are well known and have been demonstrated in different industries in different kinds of induction machines, including a few specific cases in WTs very recently [58, 59, 60]. The formulae to obtain the above-mentioned fault frequency components are presented in the following sub-sections.

2.1 Broken rotor bars, fBRB

Broken rotor bars produce an asymmetry in the rotor electric and magnetic fields. As a result, frequency components appear in the stator current that generate speed fluctuation interacting with the supply frequency [61]. Fault frequency components in the presence of broken rotor bars can be calculated as [61, 62, 63]

fBRB=fs±2sfsE1

with fsthe supply frequency and sthe slip.

It must be noted that certain degree of asymmetry will always be present in any induction machine (e.g. introduced in manufacturing); thus, the only presence of the components described in Eq. (1) may not indicate such fault. In order to differentiate between fault and no fault, the authors in [63, 64, 65] have identified the minimum difference between the amplitudes of such frequency components and the supply frequency that must be found.

Frequency components given by Eq. (1) appear near the supply frequency and overlap with different types of faults. For these reasons, different frequency components have been developed by different authors that facilitate the identification of broken rotor bars, given by [66, 67, 68]

fBRB=fsκ1sp±sE2

with κthe harmonic index (κ=1,2,3,) and pthe number of pole pairs. Based on typical winding configurations, the authors in [52, 69] stated the relation κ/p=1,5,7,.

2.2 Stator winding, fSW

Stator winding faults normally develop from inter-turn short circuits [68, 70], where a negative magnetomotive force appears in the windings. As a result, the air-gap flux changes, thus inducing harmonic frequencies in the stator current. Fault frequency components related to stator winding fault are given by [68, 70, 71]

fSW=fsκ1sp±nE3

with n=1,3,5,.

2.3 Bearing faults, fBE

The mechanical displacement that takes place in the case of radial movement between rotor and stator originated with defective bearings results in frequency components in the stator current given by [50, 72]

fBE=fs±κfo,iE4

with fo,ireferring to bearing outer and inner race fault, respectively, calculated as [52, 73, 74]

fo=0.4Nbfs1spE5
fi=0.6Nbfs1spE6

with Nbthe number of bearing balls. These equations are simplifications valid for 8–12 ball bearings.

2.4 Gearbox faults, fGBX

Gearbox damage can be of different nature, originating from a gearbox bearing, shaft, gear or pinion or a combination of them [53]. Therefore, different frequency components associated with a faulty gearbox can appear in the current spectrum. The authors in [75] identified frequency components related to damaged teeth, scoring and debris as

fGBX=fs1±κGrpE7

with Grthe gearbox ratio.

The most typical gearbox faults, however, are those related to shaft and gear faults [53, 76, 77, 78, 79, 80], calculated as Eqs. (8) and (9), respectively:

fFShafti=fs±κfShaftiE8
fFMeshj=fs±κfMeshjE9

with fShaftithe gearbox shaft rotating frequencies (with i=1,2,3) and fMeshithe gear mesh frequency (with j=1,2,3,,i1).

2.5 Eccentricity, fECC

There are two main groups of fault frequency components associated to eccentricity faults [81]: high- and low-frequency components (HF and LF, respectively). HF components are calculated as [69]

fECC,HF=fs±ν+κR±nd1spE10

with Rthe number of rotor slots, ndthe eccentricity order (nd=0for static eccentricity and nd=1,2,3,for dynamic eccentricity) and νthe order of stator time harmonics (ν=1,3,5,7,).

Load torque oscillations and load variations do not affect these HF components as much as they affect LF components [81], and they can also separate the spectral components of air-gap eccentricity from broken rotor bars. However, it is necessary to know specific information of the induction machine under study [69].

LF components, on the other hand, appear near the supply frequency, and its magnitude increases in the case of mixed eccentricity. They can be calculated as [69]

fECC,LF=fs±κfs1spE11

2.6 Rotor asymmetry, fRFS

Rotor mechanical asymmetries such as broken rotor bars, faulty end rings, etc. give rise to new frequency components in the stator current spectra [82, 83, 84] that can be calculated as

fRFS=fs1±2κsE12

2.7 Rotor unbalance, fRU

The authors in [85, 86] present a comprehensive analysis of the origins of rotor winding or brush gear unbalance faults, developing their associated analytical expressions. In their study, they identify separately health- and fault-related frequency components, calculated as Eqs. (13) and (14), respectively:

fHRU=fs6κ1s±lE13
fFRU=fsκp1s±lE14

with κthe harmonic constant for air-gap field space (κ=1,2,3,) and lthe supply time harmonic one (l=±1).

2.8 Summary of fault-related frequencies and discussion

A summary of all fault-related frequency components is provided in Table 2.

FaultFormulaEq. labelConstants
Broken rotor barfBRB=fs±2sfs(1)κp=1,5,7
fBRB=fsκ1sp±s(2)
Stator windingfSW=fsκ1sp±n(3)κ=1,2,3
n=1,3,5
Bearing damagefBE=fs±κfo,i(4)κ=1,2,3
fo=0.4Nbfs1sp(5)
fi=0.6Nbfs1sp(6)
Gearbox damagefGBX=fs±κfsGrp(7)κ=1,2,3
fFShafti=fs±κfShafti(8)
fFMeshj=fs±κfMeshj(9)
Air-gap eccentricityfECC,HF=fs±ν+κR±nd1sp(10)nd=0,1,2,3
ν=1,3,5,7
fECC,LF=fs1±κ1sp(11)κ=1,2,3
Rotor asymmetryfRFS=fs1±2κs(12)κ=1,2,3
Rotor unbalancefHRU=fs6κ1s±l(13)κ=1,2,3
fFRU=fsκp1s±l(14)l=1,2,3

Table 2.

CSA formulae.

The fault frequency components associated to the most common faults and their possible root causes have been presented. As can be seen, certain defects might produce other defects with the same effect on the current spectra. That is the case for the change in the air-gap flux caused by a fault in the stator winding (given by Eq. (3)), resulting in air-gap eccentricity (given by Eq. (11)), i.e. substituting Eq. (3) with n=1gives Eq. (11).

In the same way, stator winding impedances produce asymmetries that cause a resultant backward rotating field, thus affecting the rotor currents [73]; this is to say that faults originating in the stator will influence the rotor and vice versa. In fact, deriving from Eq. (3), the same components are obtained than those given by Eq. (14) with l=1.

Further to fault-related frequency components, a number of frequency components that are non-fault related will appear in the stator current spectra of a healthy machine. That would be the case for the stator carrier frequency (i.e. the frequency of the grid, fs) and its odd and even harmonics (2fs,3fs,4fs,5fs), which are normally present in the spectrum but are not indicative of fault. Another component that will be present in the case of a DFIG, and is not a fault indicator, is that corresponding to the difference between the stator carrier frequency (fs) and the rotor carrier frequency (frotor) [58, 59]. This component will appear to the right of fswhen the DFIG operates at a super-synchronous speed (with negative slip). Contrarily, it will appear to the left of fsat sub-synchronous speed (positive slip). Finally, as previously mentioned, frequency components given by Eq. (13) are not indicators of fault either.

All this highlights the fact that stator current spectra interpretation is not straightforward. Furthermore, fault frequency components are dependent on the rotational speed; thus the potential fault frequency components must be calculated for each operating condition. In order to exemplify in a schematic way typical CSA patterns, some are depicted in Figure 5, including that of a healthy DFIG spectra.

Figure 5.

Spectrum patterns of DFIG under healthy conditions and different fault conditions. (a) Healthy, (b) Rotor Electrical Unbalance, (c) Rotor Mechanical Unbalance, and (d) Rotor Winding Fault.

3. Case studies

This section presents the diagnosis of three different in-service WTs equipped with DFIGs using CSA. The WTs were located in different sites, thus belonging to different wind farms. Their rated power, number of pole pairs and generator technology vary from one another, as well as the monitoring period and sampling parameters. Table 3 summarises the rated power (in kW), the monitoring period (in months) and the sampling parameters (sampling rate, in Hertz, and sampling time, in seconds) for each WT DFIG presented in this study.

DFIG1DFIG2DFIG3
Nominal power [kW]85015001500
Monitoring period [months]8171
Sampling frequency [kHz]1.51.512
Sampling time [s]5.45.410.9

Table 3.

Main characteristics of the three databases used for the analysis.

The data used for the various analyses were extracted from three databases. These comprise currents from sensors located in the induction generator, the stator side and the rotor-side converter, as depicted in Figure 6. The electrical measurements used according to Figure 6 are summarised in Table 4.

Figure 6.

Drive train diagram with location of sensors in the DFIG.

Sensor locationLabel
Stator current phase aIest
Stator current phase b
Stator current phase c
Rotor-side converter current phase aIinv
Rotor-side converter current phase b
Rotor-side converter current phase c

Table 4.

Type of signals used for the analysis.

3.1 Analysis of DFIG1

DFIG1 has two pole pairs, with 1500 rpm rated speed. A test case with the WT operating nearly at full load (825 kW at 1635 rpm) with −0.0915 pu slip was chosen to illustrate the analysis. The negative slip sign is the convention for super-synchronous speed. Under these operating conditions, all possible fault frequencies (as per Table 2) were calculated, and peak search and identification were performed in the current spectra, as shown in Figure 7.

Figure 7.

Three-phase current spectra of DFIG1 showing rotor electrical unbalance.

The supply frequency (50 Hz) and its harmonics (both odd and even) are clearly seen in the spectrum. Another peak naturally present in the spectrum is that corresponding to the difference of the main frequency of the stator and the main frequency of the rotor (fsrat 54.56 Hz). Then, up to four pairs of fFRUcan be seen, as well as the first pair of fHRU. Thus, based on the peaks observed in the spectrum, the presence of rotor electrical unbalance can be concluded.

3.2 Analysis of DFIG2

DFIG2 has three pole pairs, with 1000 rpm rated speed. It presented anomalous vibration levels in the drive-end generator bearing. With only this information, the wind farm operator decided to replace the generator bearing. Right after the replacement, the vibration levels decreased. However, a few days later, these levels rose to values similar to those prior to the replacement. Visual inspection of the apparently defective bearing showed no fault in the replaced component, thus, the generator bearing was misdiagnosed.

A measurement with the WT operating at super-synchronous speed (1100 rpm, at 1100 kW power) with −0.01 pu slip was selected for this test case. Once again, the set of potential fault frequencies is calculated, and peak search and identification are carried out on the current spectra, as shown in Figure 8.

Figure 8.

Three-phase current spectra of DFIG2 showing rotor mechanical unbalance.

The supply frequency (fs) corresponds to the highest peak amplitude (at 50 Hz), as expected. It is odd harmonics are also found (150, 250 Hz, etc.), as well as the difference of the stator and rotor carrier frequencies (fsr). With regard to fault-related frequency components, no peaks related to bearing fault were found (nor to gearbox either). Only the first pair of fFRUcan be identified (thus not fault indicator). Finally, two odd pairs of fRFSare seen, belonging to rotor mechanical asymmetries. The diagnosis achieved was, therefore, rotor unbalance of mechanical nature, i.e. unbalance of the high-speed shaft.

3.3 Analysis of DFIG3

DFIG3 has two pole pairs and 1500 rpm rated speed. It was reported with excessive temperature on the rotor windings. Besides, the generator bearings were replaced two or three times a year. With a 3- to 5-year expected lifetime for these particular types of generator bearings, the idea that they were suffering damage from a generator fault arose. Thus, CSA was undertaken to find out the health status of the generator.

Similarly to the previous studies, the whole set of potential fault frequency components, as per the formulae previously described, was calculated, and peak search and identification were carried out. To illustrate the analysis, one stationary measurement with the WT operating at 1245 kW and 1791 rpm with per unit slip −0.1941 was selected. Its spectral analysis is shown in Figure 9.

Figure 9.

Three-phase current spectra of DFIG3 showing rotor winding fault.

Like in the previous analyses, odd and even supply frequency harmonics appear, showing, in this case, certain differences per phase for the second and third harmonics (2fsand 3fs, respectively). Same occurs with the frequency component associated to the difference between the stator carrier frequency (fs) and the rotor carrier frequency (frotor), indicated as fsrin Figure 9. Since the measurement was selected with the WT operating at super-synchronous speed, it falls to the right of fs, as expected. In this case, however, its reflection (denoted as fsr) can also be seen to the left of fs. A minimal amplitude for fsrcan sometimes be seen; however, the amplitude observed in Figure 9 for fsron phases a and b is higher than expected. One pair noted as fxxwas also found, which does not belong to any of the formulae previously presented.

Regarding fault-related frequency components, three pairs were identified for fFRU. Since more than one pair has been found, it does indicate a mixed eccentricity fault. Finally, two odd pairs of fRFS(f1RFSand f3RFS) appear in the current spectra, indicating a fault originating in the rotor. Unlike fFRU, no fRFSpairs are expected to appear in a healthy machine. Hence, it is possible to conclude that DFIG3 has a rotor fault which has led to mixed eccentricity.

4. Conclusions

With the rapid growth of wind energy and development of WTs, researchers and the industry are facing continuous challenges. There is also the fact that the accessibility of offshore wind farms can be limited or restricted for several months. All this, together with the fact that an important share of the existing wind turbine fleet has already achieved its 20-year estimated lifetime, shows that availability and reliability of wind turbines must be developed in parallel. Furthermore, wind energy is expected to play a key role in the short- and long-term electricity market. Thus, the various technical and economical issues surrounding WTs and wind farms must be studied and addressed towards financially viable wind energy.

O&M of wind farms represents an important share of the total expenditure costs; therefore, it is vital to optimise the strategies implemented while increasing reliability and availability of wind turbines. The induction generator is one of the critical components of a WT, together with the drive train and hub and blade assemblies. Under this scenario, the use of electrical measurements to monitor the induction generator has been presented in this chapter.

CSA has been chosen as the CM method for diagnosing three DFIGs of in-service WTs. The technique has been presented, and spectral analyses have been conducted. Fault frequency components related to different faults have been identified in the spectra of the three machines. DFIG1 was diagnosed with rotor electrical unbalance, DFIG2 with rotor mechanical unbalance and DFIG3 with rotor winding fault. CSA has thus been proven as a valid method to diagnose in-service WTs equipped with DFIG that can be implemented in commercial CM systems of WTs.

Acknowledgments

This research originated from the AWESOME Project, funded by the European Union Horizon 2020 research and innovation program under the Marie Sklodowska-Curie Grant Agreement No. 642108.

CBMcondition-based maintenance
CMcondition monitoring
CSAcurrent signature analysis
DFIGdoubly-fed induction generator
FBMfailure-based maintenance
GWECglobal wind energy council
LCOElevelized cost of electricity
LTElifetime extension
O&Moperation and maintenance
RTUremaining useful life
SCADAsupervisory control and data acquisition
TBMtime-based maintenance
WTwind turbine

How to cite and reference

Link to this chapter Copy to clipboard

Cite this chapter Copy to clipboard

Estefania Artigao, Andrés Honrubia-Escribano, Sergio Martín-Martínez and Emilio Gómez-Lázaro (April 15th 2020). The Use of Electrical Measurements of Wind Turbine Generators for Drive Train Condition Monitoring, Design Optimization of Wind Energy Conversion Systems with Applications, Karam Y. Maalawi, IntechOpen, DOI: 10.5772/intechopen.90127. Available from:

chapter statistics

48total chapter downloads

More statistics for editors and authors

Login to your personal dashboard for more detailed statistics on your publications.

Access personal reporting

Related Content

This Book

Design Optimization of Wind Energy Conversion Systems with Applications

Edited by Karam Maalawi

Next chapter

Reliability Assessment of Wind Turbines

By Mai F.M. Ayoub

Related Book

First chapter

Introductory Chapter: An Introduction to the Optimization of Composite Structures

By Karam Maalawi

We are IntechOpen, the world's leading publisher of Open Access books. Built by scientists, for scientists. Our readership spans scientists, professors, researchers, librarians, and students, as well as business professionals. We share our knowledge and peer-reveiwed research papers with libraries, scientific and engineering societies, and also work with corporate R&D departments and government entities.