1. Introduction
Many tactile sensors have been developed to enhance robotic manufacturing tasks, such as assembly, disassembly, inspection and materials handling as described in several survey papers (Harmon, 1982; Nicholls & Lee 1989; Ohka, 2009a). In the last decade, progress has been made in tactile sensors by focusing on limited uses. Many examples of practical tactile sensors have gradually appeared. Using a Micro Electro Mechanical System,
In particular, the three-axis tactile sensor that is categorized as an
Our three-axis tactile sensor is based on the principle of an optical waveguide-type tactile sensor (Mott et al., 1984; Tanie et al., 1986; Nicholls et al., 1990; Kaneko et al., 1992; Maekawa et al., 1992), which is composed of an acrylic hemispherical dome, a light source, an array of rubber sensing elements, and a CCD camera (Ohka, 1995, 2004a, 2005a, 2005b, 2008). The sensing element of the silicone rubber comprises one columnar feeler and eight conical feelers. The contact areas of the conical feelers, which maintain contact with the acrylic dome, detect the three-axis force applied to the tip of the sensing element. Normal and shearing forces are then calculated from integration and centroid displacement of the grayscale value derived from the conical feeler’s contacts.
The tactile sensor is evaluated with a series of experiments using an x-z stage, a rotational stage, and a force gauge. Although we discovered that the relationship between the integrated grayscale value and normal force depends on the sensor’s latitude on the hemispherical surface, it is easy to modify the sensitivity based on the latitude to make the centroid displacement of the grayscale value proportional to the shearing force.
To demonstrate the effectiveness of the three-axis tactile sensor, we designed a hand system composed of articulated robotic fingers sensorized with the three-axis tactile sensor (Ohka, 2009b, 2009c). Not only tri-axial force distribution directly obtained from the tactile sensor but also the time derivative of the shearing force distribution are used for the hand control algorithm: the time derivative of tangential force is defined as slippage; if slippage arises, grasping force is enhanced to prevent fatal slippage between the finger and an object. In the verification test, the robotic hand twists on a bottle cap completely.
In the following chapters, after the optical three-axis tactile sensor is explained, the robotic hand sensorized with the tactile sensors is described. The above cap-twisting task is discussed to show the effectiveness of tri-axial tactile data for robotic control.
2. Optical three-axis tactile sensor
2.1. Sensing principle
2.1.1. Structure of optical tactile sensors
Figure 1 shows a schematic view of the present tactile processing system to explain the sensing principle. The present tactile sensor is composed of a CCD camera, an acrylic dome, a light source, and a computer. The light emitted from the light source is directed into the optical waveguide dome. Contact phenomena are observed as image data, acquired by the CCD camera, and transmitted to the computer to calculate the three-axis force distribution.
In this chapter, we adopt a sensing element comprised of a columnar feeler and eight conical feelers, as shown in Fig. 2, because the element showed wide measuring range and good linearity in a previous paper (Ohka, 2004b). Since a single sensing element of the present tactile sensor should carry a heavier load compared to a flat-type tactile sensor, the height of the columnar feeler of the flat-type tactile sensor is reduced from 5 to 3 mm. The sensing elements are made of silicone rubber (KE119, Shinetsu) and are designed to maintain contact with the conical feelers and the acrylic board and to make the columnar feelers touch an object. Each columnar feeler features a flange to fit into a counter bore portion in the fixing dome to protect the columnar feeler from horizontal displacement caused by shearing force.
2.1.2. Expressions for sensing element located on vertex
Dome brightness is inhomogeneous because the edge of the dome is illuminated and light converges on its parietal region. Since the optical axis coincides with the center line of the vertex, the apparent image of the contact area changes based on the sensing element’s latitude. Although we must consider the above problems to formulate a series of equations for the three components of force, the most basic sensing element located on the vertex will be considered first.
Coordinate O-
where
2.1.3. Expressions for sensing elements other than those located on vertex
For sensing elements other than those located on the vertex, each local coordinate O
Centroid displacements included in Eqs. (1) and (2), and
2.1.4. Design of optical three-axis tactile sensor
Since the tactile sensor essentially needs to be a lens system, it is difficult to make it thinner; thus, it should be designed as a type of integrated fingertip and hemispherical three-axis tactile sensor, as shown in Fig. 4 (Ohka et al., 2008). Forty-one sensing elements are concentrically arranged on the acrylic dome, which is illuminated along its edge by optical fibers connected to a light source (ELI-100S, Mitsubishi Rayon Co.) Image data consisting of bright spots caused by the feelers’ collapse (MSGS-1350-III, Moritex Co.) are retrieved by an optical fiber scope connected to the CCD camera (C5985, Hamamatsu Photonics Co.)
2.2. Procedure of evaluation tests
2.2.1. Experimental apparatus
We developed a loading machine shown in Fig. 5 that includes an x-stage, a z-stage, rotary stages, and a force gauge (FGC-0.2B, NIDEC-SIMPO Co.) to detect the sensing characteristics of normal and shearing forces. The force gauge has a probe to measure force
and can detect force ranging from 0 to 2 N with a resolution of 0.001 N. The positioning precisions of the
2.2.2. Procedure of sensing normal force test
Because the present tactile sensor can detect not only normal force but also shearing force, we must confirm the sensing capability of both forces. In normal-force testing, by applying a normal force to the tip of a sensing element using the z-stage after rotating the attitude of the tactile sensor, it is easy to test the specified sensing element using the rotary stage. Since the rotary stage’s center of rotation coincides with the center of the present tactile sensor’s hemispherical dome, testing any sensing element aligned along the hemisphere’s meridian is easy.
2.2.3. Procedure of sensing shearing force test
When generating the shearing-force component, both the rotary and x-stages are adjusted to specify the force direction and sensing element. First, the rotary stage is operated to give force direction
at the tip of the specified sensing element. Figure 8 shows that the sensing element located on the parietal region can be assigned based on the procedure described above. After that, a force is loaded onto the tip of the sensing element using the
of loading, since the force direction does not coincide with the axis of the sensing element, slippage between the probe and the tip of the sensing element occurs. To eliminate this problem, a spherical concave portion is formed on the probe surface to mate the concave portion with the hemispherical tip of the tactile element. Normal force
2.3. Sensing ability of optical three-axis tactile sensor
2.3.1. Sensing ability of normal force
To evaluate the sensing characteristics of sensing elements distributed on the hemispherical dome, we need to measure the variation within the integrated grayscale values generated by the sensor elements. Figure 9 shows examples of variation in the integrated grayscale value caused by increases in the normal force for sensors #00, #01, #05, #09, #17, #25, and #33. In these experiments, normal force is applied to a tip of each tactile element. As the figure indicates, the gradient of the relationship between the integrated grayscale value and applied force increases with an increase in
However, sensing elements located at the same latitude
As shown in Fig. 9, the relationship between the integrated grayscale value and applied normal force is not completely linear. Therefore, we adopt the bi-linear lines shown in Fig. 10 as function
To show that under the combined loading condition normal force component was independently obtained with Eq. (3), we applied inclined force to the tip of the tactile element to examine the relationship between the normal component of applied force and integrated grayscale value. Figure 11 displays the relationship for #00. Even if the inclination is varied from -30
2.3.2. Sensing ability of shearing force
When force is applied to the tip of the sensing element located in the parietal region under several
When the tactile element accepts directional forces of 45
3. Object handling based on tri-axial tactile data
3.1. Hand robot equipped with optical three-axis tactile sensors
We designed a two-fingered robotic hand as shown in Fig. 14 for general-purpose use in robotics (Ohka et al., 2009b, 2009c). The robotic hand includes links, fingertips equipped with the three-axis tactile sensor, and micro actuators (YR-KA01-A000, Yasukawa). Each micro actuator, which consists of an AC servo-motor, a harmonic drive, and an incremental encoder, was particularly developed for application to a multi-fingered hand. Since the tactile sensors must be fitted to a multi-fingered hand, we are developing a fingertip that includes the hemispherical three-axis tactile sensor shown in Fig. 4.
3.2. Kinematics of hand robot
As shown in Fig. 14, each robotic finger has three movable joints. The frame of the workspace is set on the bottom of the z-stage. The kinematics of the present hand is derived according to Denavit-Hartenberg notation shown in Fig. 14. The frame of the workspace is defined as O-
to satisfy specified velocity vector
where
In the above equations, the rotations of the first frame around the
Position control of the fingertip is performed based on resolved motion rate control. In this control method, joint angles are assumed at the first step, and displacement vector
3.3. Control algorithm
Our objective is to show that the robotic hand adapts its finger trajectory to the environment according to tri-axial tactile data. Hence, we make a simple control algorithm for the hand. In the algorithm, there is an assumption that finger trajectory provided beforehand to the hand is as simple as possible. The trajectory is modified to prevent normal force from exceeding a threshold and to stabilize slippage caused on the contact area according to tri-axial tactile data.
The hand is controlled according to velocity control. First, hand status becomes “search mode” to make fingers approach an object with finger speed
However, if normal force of a sensing element exceeds a threshold
In our system, the sensor control program and hand control program are executed in different computers because CPU time is efficiently consumed using a multi-task program method. These programs are synchronized with the following five flags.
SEARCH: Fingers search for an object with initial finger velocity
MOVE: This flag is raised whenever the robotic hand manipulates an object.
TOUCH: This flag is raised whenever one of the fingers touches an object.
SLIP: This flag is raised whenever the time derivative of shearing force exceeds a threshold
OVER: This flag is raised when normal force of a sensing element exceeds a threshold
These flags are decided according to tri-axial tactile data and finger motions. Since two modules, the flag analyzer and finger speed estimator, mainly play the role of object handling, these modules are shown in Figs. 15 and 16, respectively.
In the flag analyzer, TOUCH flag, SLIP flag and OVER flag are decided. The flag analyzer regards finger status as touching an object when normal force of a sensing element is exceeded or the absolute time derivative of the shearing force is exceeded (SLIP flag is raised). Whenever it regards finger status as touching an object, the TOUCH flag is raised. The OVER flag is raised when normal force of a sensing element exceeds
In the finger speed estimator, the velocity of the fingertip is determined based on the five flag values and conserved whenever contact status is not changed. Since the cap-twisting problem requires touch-and-release motion, the MOVE and SEARCH flags are controlled according to the TOUCH flag and time spent. Whenever the SLIP flag is raised, a sensing element of the largest normal force is determined and the re-compressive velocity of the finger is determined as an inward normal line of the sensing element. The re-compressive velocity is added to the current velocity, and the resultant velocity is applied to the control module.
3.4. Evaluation experiment of object handling
3.4.1. Experimental apparatus and procedure
To examine the above algorithm, the robotic hand performed the bottle cap-closing task because this task requires a curved trajectory along the cap contour. Evaluation of cap closing is performed using an apparatus including a torque sensor. Figure 17 shows the apparatus composed of the two-fingered hand, the torque sensor (TCF-0.2N, Nippon Tokushu Sokki, Co., Ltd.) and a PET bottle holder. A PET bottle is clamped with two twists of the PET holder, and its cap is turned by the robotic hand. The torque sensor measures torque with four strain gauges. Variation in gauge resistance is measured as voltage through a bridge circuit, and it is sent to a computer with an A/D converter to obtain the relationship between finger configuration and generated torque.
The experimental apparatus is shown in Fig. 17. A PET bottle is held by the holder. At first, two fingers approach the cap, and moving direction is changed to the tangential direction of the cap surface after grasping force exceeds 1 N. After the finger moves, keeping the direction within 10 mm, the fingers are withdrawn from the cap surface and returned to each home position from which they started moving. Consequently, the trajectory of the fingers is designed as shown in Fig. 17. During the task of closing the cap, variation in torque is monitored through the torque sensor to evaluate the task. Even if the trajectory is simple, we will show that it adapts to the cap contour in the following section.
3.4.2. Relationship between grasping force and torque
The relationship between grasping force and torque while twisting the bottle cap is shown in Fig. 18 as an overview of the experiment. Since touch-and-release motion is continued four times, four groupings are found in Fig. 18. As shown in Fig. 18, compared to the first twisting motion, both grasping force and torque decrease considerably in the second twisting, and in the third and fourth twistings they increase compared to the former two twistings. Since the third and fourth twistings show almost the same variations in grasping force and torque, twisting seems to become constant. Therefore, after the third twisting, the cap seems to be closed. In the first twisting, we can observe the transition from light twisting to forceful twisting because torque increases in spite of constant grasping force. It is shown that the cap is turned without resistant torque at first. The reason for reducing grasping force and torque in the second twisting is the variation in contact position and status between the first and second twistings. Twisting on the cap was successfully completed as mentioned above.
3.4.3. Relationship between time derivative of shearing force and torque
When the cap is twisted on completely, slippage between the robotic finger and the cap occurs. To examine this phenomenon, the relationship between the time derivative of the shearing force and torque is shown in Fig. 19. As can be seen, the time derivative of the shearing force shows periodic bumpy variation. This bumpy variation synchronizes with variation in torque. This means large tangential force induces the time derivative of the shearing force, which is caused by the trembling of the slipping sensor element.
To examine the cap-twisting, a comparison between the results of the first screwing and fourth twisting is performed with Figs. 20 and 21. In the first twisting, since the cap is loose, the marked time derivative of the shearing force does not occur in Fig. 20. On the other hand, in the fourth twisting, the marked time derivative of the shearing force does occur because of the securing of the cap (Fig. 21). Therefore, the robotic hand can twist on the bottle cap completely. Additionally, the time derivative of the shearing force can be adopted as a measure for twisting the cap.
3.4.4. Trajectory of fingertip modified according to tri-axial tactile data
Trajectories of sensor element tips are shown in Figs. 22 and 23. If the result of Fig. 22 is compared with the result of Fig. 23, trajectories of Fig. 23 are closer to the cap contour. Modification of the trajectory is saturated after closing the cap. Although input finger trajectories were a rectangle roughly decided to touch and turn the cap as described in the previous section, a segment of the rectangle was changed from a straight line to a curved line to fit the cap contour.
4. Conclusion
We developed a new three-axis tactile sensor to be mounted on multi-fingered hands, based on the principle of an optical waveguide-type tactile sensor comprised of an acrylic hemispherical dome, a light source, an array of rubber sensing elements, and a CCD camera. The sensing element of the present tactile sensor includes one columnar feeler and eight conical feelers. A three-axis force applied to the tip of the sensing element is detected by the contact areas of the conical feelers, which maintain contact with the acrylic dome. Normal and shearing forces are calculated from integration and centroid displacement of the grayscale value derived from the conical feeler’s contacts.
To evaluate the present tactile sensor, we conducted a series of experiments using a
Next, a robotic hand was composed of two robotic fingers to indicate that tri-axial tactile data generated the trajectory of the robotic fingers. Since the three-axis tactile sensor can detect higher order information compared to the other tactile sensors, the robotic hand’s behavior is determined on the basis of tri-axial tactile data. Not only tri-axial force distribution directly obtained from the tactile sensor but also the time derivative of shearing force distribution is used for the hand-control program. If grasping force measured from normal force distribution is lower than a threshold, grasping force is increased. The time derivative is defined as slippage; if slippage arises, grasping force is enhanced to prevent fatal slippage between the finger and object. In the verification test, the robotic hand twists on a bottle cap completely. Although input finger trajectories were a rectangle roughly decided to touch and turn the cap, a segment of the rectangle was changed from a straight line to a curved line to fit the cap contour. Therefore, higher order tactile information can reduce the complexity of the control program.
We are continuing to develop the optical three-axis tactile sensor to enhance its capabilities such as sensing area, precision and sensible range of load. Furthermore, we will apply the hand to more practical tasks such as assemble-and-disassemble and peg-in-hole tasks in future work.
References
- 1.
Borovac B. Nagy L. Sabli M. 1996 Contact Tasks Realization by sensing Contact Forces, Theory and Practice of Robots and Manipulators, Proc. of 11th CISM-IFToNN Symposium, Springer Wien New York,381 388 , 1996. - 2.
Chigusa H. Makino Y. Shinoda H. 2007 Large Area Sensor Skin Based on Two-Dimensional Signal Transmission Technology, Proc. World Haptics 2007, Mar., Tsukuba, Japan,151 156 ,. - 3.
Hackwood S. Beni G. Hornak L. A. Wolfe R. Nelson T. J. 1983 Torque-Sensitive Tactile Array for Robotics, Int. J. Robotics Res.,2-2 ,46 50 , 1983. - 4.
Hakozaki M. Shinoda H. 2002 Digital Tactile Sensing Elements Communicating Through Conductive Skin Layers, Proc. of 2002 IEEE Int. Conf. On Robotics and Automation,3813 3817 , 2002. - 5.
Harmon L. 1982 1982, Automated Tactile Sensing, Int. J. Robotics Res.,1 2 3 32 , 1982. - 6.
Hasegawa Y. Shikida M. Shimizu T. Miyaji T. Sakai H. Sato K. Itoigawa K. 2004 A Micromachined Active Tactile Sensor for Hardness Detection, Sensors and Actuators (A Physical),114 2-3 ,141 146 , 2004. - 7.
Kamiyama K. Vlack K. Mizota T. Kajimoto H. Kawakami N. Tachi S. 2005 Vision-Based Sensor for Real-Time Measuring of Surface Traction Fields, IEEE Computer Graphics and Applications, January/February,68 75 , - 8.
Kaneko M. Maekawa H. Tanie K. 1992 Active Tactile Sensing by Robotic Fingers Based on Minimum-External-Sensor-Realization, Proc. of IEEE Int. Conf. on Robotics and Automation,1289 1294 ,. - 9.
Maekawa H. Tanie K. Komoriya K. Kaneko M. Horiguchi C. Sugawara T. 1992 Development of a Finger-shaped Tactile Sensor and Its Evaluation by Active Touch, Proc. of the 1992 IEEE Int. Conf. on Robotics and Automation,1327 1334 , - 10.
Mott H. Lee M. H. Nicholls H. R. 1984 An Experimental Very-High-Resolution Tactile Sensor Array, Proc. 4th Int. Conf. On Robot Vision and Sensory Control,241 250 ,. - 11.
Nicholls H. R. Lee M. H. 1989 A Survey of Robot Tactile Sensing Technology, Int. J. Robotics Res.,8-3 ,3 30 ,. - 12.
Nicholls H. R. 1990 Tactile Sensing Using an Optical Transduction Method, Traditional and Non-traditional Robot Sensors (Edited by T. C. Henderson), Springer-Verlag,83 99 , - 13.
Novak J. L. 1989 Initial Design and Analysis of a Capacitive Sensor for Shear and Normal Force Measurement, Proc. of 1989 IEEE Int. Conf. On Robotic and Automation,137 145 , - 14.
Ohka M. Mitsuya Y. Takeuchi S. Ishihara H. Kamekawa O. 1995 A Three-axis Optical Tactile Sensor (FEM Contact Analyses and Sensing Experiments Using a Large-sized Tactile Sensor), Proc. of the 1995 IEEE Int. Conf. on Robotics and Automation,817 824 ,. - 15.
Ohka M. Mitsuya Y. Matsunaga Y. Takeuchi S. 2004 Sensing Characteristics of an Optical Three-axis Tactile Sensor Under Combined Loading, Robotica,22 213 221 ,. - 16.
Ohka M. Mitsuya Y. Higashioka I. Kabeshita H. 2005 An Experimental Optical Three-axis Tactile Sensor for Micro-robots, Robotica,23 457 465 ,. - 17.
Ohka M. Kobayashi H. Takata J. Mitsuya 2008 An Experimental Optical Three-axis Tactile Sensor Featured with Hemispherical Surface, Journal of Advanced Mechanical Design, Systems, and Manufacturing,2-5 ,860 873 ,. - 18.
Ohka M. 2009 Robotic Tactile Sensors, Wiley Encyclopedia of Computer Science and Engineering,,2454 2461 . - 19.
Ohka M. Takata J. Kobayashi H. Suzuki H. Morisawa N. Yussof H. B. 2009 60.Object Exploration and Manipulation Using a Robotic Finger Equipped with an Optical Three-axis Tactile Sensor, Robotica,27 763 770 ,. - 20.
Ohka, M., Morisawa, N., and Yuss of, H., B.,Trajectory Generation of Robotic Fingers Based on Tri-axial Tactile Data for Cap Screwing Task ,,883 888 883888 2009. - 21.
Shimojo M. Namiki A. Ishikawa M. Makino R. Mabuchi K. 2004 A Tactile Sensor Sheet Using Pressure Conductive Rubber with Electrical-wires Stitched Method, IEEE Trans. Sensors,5-4 ,589 596 ,. - 22.
Tanaka M. Leveque J. Tagami H. Kikuchi K. 2003 Chonan, The ‘‘Haptic finger’’- a New Device for Monitoring Skin Condition, Skin Research and Techonology,9 131 136 ,. - 23.
Tanie K. Komoriya K. Kaneko M. Tachi S. Fujiwara A. 1986 A High-Resolution Tactile Sensor Array, Robot Sensors2 Tactile and Non-Vision, Kempston, UK: IFS (Pubs),189 198 ,. - 24.
Yamada Y. Cutkosky R. 1994 Tactile Sensor with 3-Axis Force and Vibration Sensing Function and Its Application to Detect Rotational Slip, Proc. of 1994 IEEE Int. Conf. On Robotics and Automation,3550 3557 ,