1. Introduction

In many kinds of experimental measurements, such as astrophysics, atomic physics, biophysics, geophysics, high energy physics, nuclear physics, plasma physics, solid state physics, bending or torsion elastic, heat propagation or statistical mechanics, the signal measured in the laboratory can be expressed mathematically as a convolution of two functions. The first represents the resolution function called the instrumental signal, which is specific for each setup, and the second is the true sample that contains all physical information. These phenomena can be modelled by an integral equation, which means the unknown function is under the integral operator. The most important type of integral equation applied in physical and technical signal treatments is the Fredholm integral equation of the first kind. The opposite process when used for true sample function determination is known in the literature as experimental data deconvolution. Solution determination of the deconvolution equation does not readily unveil its true mathematical implications concerning the stability of the solutions or other aspects. Thus, from this point of view, the problem is described as improper or ill-posed. The most rigorous methods for solving the deconvolution equation are: regularization, spline function approximation and Fourier transform technique. The essential feature of regularization method is the replacement of a given improper problem with another, auxiliary, correctly posed problem. The second method consists in approximating both the experimental and instrumental signals by piecewise cubic spline. Most often when using this technique, the true sample function belongs to the same piecewise cubic spline class. The topic of this chapter is the application of Fourier transform in experimental data deconvolution for use in nanomaterial structures.

Advertisement

2. Mathematical background of signal deconvolution

As mentioned in the introduction, ill-posed problems from a mathematical point of view have many applications in physics and technologies [1]. In addition to the abovementioned examples, the examples below should be noted.

Solving the Cauchy problem for the Laplace equation, ΔU=0 has a direct application in biophysics as in [2]. The problem consists in determining the biopotential distribution within the body denoted by U, when the body surface potential values are known. The phenomenon is modelled by the Laplace equation, and the Cauchy conditions are U|S=f(S) and Un|S=0, where S represents the surface of the body.

The determination of radioactive substances in the body, as in [2], and protein crystallography structures also deal with ill-posed problems: see [3].

The same formalism is used in quantum mechanics to determine the particle scattering cross-section on different targets, as well as in plasma physics in the case of the electron distribution after speed is received from the dispersion curve analysis [2].

An intuitive way of grasping an ill-posed problem can be modelled by the movement of the vibrating string when many forces are acting perpendicularly on the string, as represented in Figure 1.

Figure 1.

Physical model of the vibrating string

In terms of the mathematical equation, the phenomenon described above has a correspondent in physics spectroscopy used in the study of nanomaterials. In the first instance, it is considered that in the point of abscissa xk, force fk acts perpendicularly to the direction of the string. The string movement in the vertical plane at an arbitrary point s is given by the proportionality relationship,

h(s)=g(s,xk)f(xk)E1

where g(s,xk) characterizes the impact of force f(xk) on the movement h(s). Using the same considerations, for N forces f1,f2,, fN  that act independently in N points of abscissa x1, x2,..., xN in the direction perpendicular to the string, the string movements will be obtained as h1, h2,..., hN. Therefore the movement associated with an arbitrary point of the string of abscissa s is described by the relation below

h(s)=g(s,x1)f(x1)+g(s,x2)f(x2)++g(s,xk)f(xk)=i=1Ng(s,xk)f(xk)E2

When a force is distributed continuously along the entire string, the movement of the point s of the string will be given by

h(s)=0lg(s,x)f(x)dxE3

where l represents the length of the string.

The function f is the density of force, which means the force per unit length, and f(x)dx represents the force that acts on the arc element dx. The function g is called the influence function because it shows the degree of influence of the distribution force f on displacement h.

The equation (3) is named the Fredholm integral equation of the first kind, and it is a particular case of the integral equation,

l(s)f(s)+abg(s,x)f(x)dx=h(s),cxdE4

where l, g and h are continuous known functions. If function l is null, then equation (4) represents an integral equation of the first kind. If function l has no zero on [c,d] then the equation (4) is of the second kind, while if l has some zeros on [c,d] then the equation (4) is of the third kind.

Although the aim of this chapter is signal deconvolution using the Fourier transform, it is important to mentionthe other two methods used to solve equation (4) when l0, that is, the regularization method and the spline approach.

Hadamard stated that a problem is well posed if it has a unique solution, and the solution depends continuously on the data [4]. Any problem that is not a well-posed problem is an ill-posed one. The Fredholm equation of the first kind is ill posed because small changes in the data generate huge modification of the unknown function.

2.1. Regularization method

This method consists in the replacement of the ill-posed problem (4) with l0 by a well-posed problem, and there are many scientific papers that develop different types of regularization method depending on kernel type and other specific needs. Below we describe the Tikhonov regularization method applied to the equation (4) with l0. Let X and Y be Hilbert spaces and be the norm on Hilbert space. If the kernel g is smooth, the operator G:XY

(Gf)(s)=abg(s,x)f(x)dxE5

is linear. Then equation (4) with l0 becomes

Gf=hE6

The regularization method consists in the determination of the approximate solution of the equation (4) of the first kind as a minimization of the following functional

Φa(f)=G-h2+αLf2,fXE7

The value α>0 represents the regularization parameter and L is a linear operator defined below

Lf=a0(ff^)+a1f'+a2f''E8

where ai has the value 0 or 1; and f' and f'' are the first and the second derivative of f. Function f^ represents a trial solution for equation (4) with l0. The regularization order for the operator L is the same as the derivability order of f. The regularization parameter should be chosen carefully, because a good minimum for the functional (7) does not always lead to an adequate solution for equation (4) with l0 as in [4]. The discrimination procedure of the equation (4) with l0 and functional (7) depends on the specifics of each type of problem such as domain, type of kernel, etc., but this is not the subject of this chapter: see [4-6].

Some disadvantages of the regularization method, which is an iterative method, are the fact that it is very sensitive to the noise present in the experimental function and is time consuming.

If the kernel g of the equation (4) with l0 has a delayed argument then the equation is called a convolution equation, and is widely applied in physical spectroscopy. The general form of a convolution equation is given by

h(s)=g(sx)f(x)dxE9

After the change of variable x=t-s it is found that (9) is equivalent by the equation

h(s)=g(t)f(ts)dtE10

2.2. Spline technique

Spline functions for signal deconvolution technique help eliminate the drawbacks mentioned above [7]. The advantage of the method proposed in [7] lies in the fact that Beniaminy’s method is a one-step method. In this case, the true sample function f is represented as a piecewise cubic spline function, and after the substitution of it into equation (10), the experimental function h becomes a piecewise cubic spline function with the same knots but different coefficients. The connection between the coefficients of functions h and f are given by the moments of instrumental function g. Thus, if function f has the form

f(t)=k=1n1sk(t)E11

where

sk(t)={0ift<ξkakt3+bkt2+ckt+dkifξktξk+10ifξk+1<tE12

with ξk,k=1,n1¯ are the knots and ak, bk, ck and dk are the coefficients of the spline function f. They are chosen such that the function together with its first two derivatives is continuous. Replacing (12) in (11), the experimental function has the form

h(s)=k=1n1(Akt3+Bkt2+Ckt+Dk)E13

where

Ak=akM0Bk=bkM03akM1Ck=3akM22bkM1+ckM0Dk=akM3+bkM2ckM1+dkM0E14

and Mk=tkg(t)dt represents the moment of order k. Beniaminy considered that experimental function h given by (14) is a cubic spline function. In [8] it is shown that that function h is not a spline function due to the lack of the continuity in the first two derivatives of h. However, the algorithm from [7] gives good results, but the quality of the true sample function depends on how wide the instrumental function is. In order to obtain the true sample function f given by (12) and (13), we calculate spline coefficients of the experimental function and using these values and (14) obtain the coefficients ak, bk, ck and dk.

2.3. Solving the convolution equation using Fourier transform

Take the functions h, f, and g whose Fourier transform is given by the functions H, F and G. By applying the Fourier transform operator on both members of equation (10) we obtain

+h(s)exp(2πiνs)ds=+[+g(τ)f(sτ)dτexp(2πiνs)]dsE15

By changing the order of integration, the Fourier transform of the signal h is expressed by the relation,

H(ν)=+g(τ)[+f(sτ)exp(2πiνs)ds]dτE16

Using the substitution σ=sν, the quantity between square brackets from the previous relation becomes

+f(σ)exp[2πiν(σ+τ)]dσ=exp(2πiντ)+f(σ)exp(2πiνσ)dσ=exp(2πiντ)F(υ)E17

In this context the relation (16) becomes

H(ν)=+g(τ)exp(2πiντ)F(ν)dτ=F(ν)G(ν)E18

The relation (18) is known as the convolution theorem. If direct and inverse Fourier transform operators and convolution product are respectively denoted by TF, TF-1 and *, then the relation (18) is written symbolically as

TF(h)=TF(f)TF(g)=FG=TF(fg)

and

TF1(FG)=h=fg

In this way, the process of the inverse Fourier transform applied to function F determines f signal. In X-ray diffraction theory this is known as the Stokes method.

Experimental signals h, coded by (1), (3), (5) and (6) for a set of supported gold catalyst (Au/SiO2), and instrumental contribution g measured on a gold foil, are presented in Figure 2.

Figure 2.

The experimental relative intensities h of the supported gold catalysts and instrumental function g

Advertisement

3. Why is the technique of deconvolution used in nanomaterials science?

In the scientific literature we can see many authors display serious confusion about the concept of deconvolution. Often, when they decompose the experimental signal h according to certain specific criteria, some say that it has achieved the deconvolution of the initial signal. This fact may be accepted only if the instrumental function g from equation (11) is described by the Dirac distribution. Only in this case is the true sample function f identical to the experimental signal h. Unfortunately, no instrumental function of any measuring device can be described by the Dirac distribution.

It is well known that the macroscopic physical properties of various materials depend directly on their density of states (DS). The DS is directly linked to crystallographic properties. For physical systems that belong to the long order class, moving the crystallographic lattice in the whole real space will reproduce the whole structure. The nanostructured materials, which belong to the short-range class, are obtained by moving the lattice in the three crystallographic directions at the limited distances, generating crystallites whose size is no greater than a few hundred angstroms. In this case, the DS is drastically modified in comparison with the previous class of materials. From a physical point of view the DS is closely related to the nanomaterials’ dimensionality, so crystallite size gives direct information about new topological properties. It can emphasize that amorphous, disordered or weak crystalline materials can have new bonding and anti-bonding options. The systems consisting of nanoparticles whose dimensions do not exceed 50 Å have the majority of atoms practically situated on the surface for the most part. Additionally, the behaviour of crystallites whose size is between 50 Å and 300 Å is described on the basis of quantum mechanics to explain the advanced properties of the tunnelling effect. All these reasons lead to the search for an adequate method to determine reliable information such as effective particle size, microstrains of lattice, and particle distribution function. This information is obtained by Fourier deconvolution of the instrumental and experimental X-ray line profiles (XRLP) approximated by Gauss, Cauchy and Voigt distributions and generalized by Fermi function (GFF) as in [9]. The powder reflection broadening of the nanomaterials is normally caused by small size, crystallites and distortions within crystallites due to dislocation configurations. It is the most valuable and cheapest technique for the structural determination of crystalline nanomaterials.

Generally speaking, in X-ray diffraction on powder, the most accurate and reliable analysis of the signals is given by the convolution equation (10) where h, g and f are experimental data, instrumental contribution of setup experimental spectrum, and true sample function as a solution of equation (10), respectively.

Figure 3.

Numerical solution of the deconvolution equation (19) determined by an algebraic discretization

Let us consider the experimental signals of (111) X-ray line profile of supported nickel catalyst, and the instrumental function given by nickel foil obtained by a synchrotron radiation setup at 201 points with a constant step of 0.040 in 2θ variables, as shown in Figure 3.

The convolution equation (9) can be approximated in different ways, but the simplest approximation is given by following the algebraic system

h(xi)=j=201201g(xisj)f(sj)Δsji=1,201E19

where Δsj is a constant step in 2θ variables. It turns out that the roots f(sj) of system (19) do not lead to a smooth signal, but yield a curve which makes for enhanced oscillations. Its behaviour is given by f signal in Figure 3. This result is given by a computer code written in Maple 11 language, a sequence of which is presented in Appendix 1. From a physical point of view, this type of solution is impracticable because the crystallite size in nanostructured systems is contained in the tails of XRLP. Therefore, the lobes of the XRLP must be sufficiently smooth. As shown in the inset of Figure 3, this condition is not met.. It would be possible to improve the quality of signal f trying to extend the definition interval for signal g. Thus we will approximate the unbounded integral on a bounded interval, but one that is sufficiently large.

This depends on the performances of the computer system and on the algorithm developed for solving inhomogeneous systems of linear equations with sizes of at least several thousand.

Advertisement

4. Distributions frequently used in physics and chemical signal deconvolution applied in nanomaterials science

It is known that, from a mathematical point of view, the XRLP are described by the symmetric or asymmetric distributions. As in [10,11] a large variety of functions for analysis of XRLP, such as Voigt (V), pseudo-Voigt (pV) and Pearson VII (P7), are proposed.

4.1. Gauss distribution

Many results such as the propagation of uncertainties and the least square method can be derived analytically in explicit form when the relevant variables are normally distributed. Gauss distribution is defined by mathematical relation

IG=I0GπγGexp[(xaγG)2]E20

where I0G, a and γG are the profile area, gravitational centre measured in 2θ variable, and broadening of the XRLP, respectively. The nth moment, n=0,1 is given by relations

μ0G=+IG(x)dx=I0G,μ1G=a

The integral width δG and full width at half maximum FWHMG are given by relations

δG=πγGandFWHMG=2ln2γG

If both signals h and g are described by Gaussian distributions and take into account the relationship (18), the full width and FWHM of the true sample function are expressed by the relations

γG,f=γG,h2γG,g2FWHMG,f=2ln2γG,fE21

4.2. Cauchy distribution

The Cauchy distribution, also called the Lorentzian distribution, is a continuous distribution that describes population distribution of electron levels with multiple applications in physical spectroscopy. Its analytical expression is given by relation

IC=I0CπγCγC2+(xa)2E22

where I0C, a and γC are profile surface, gravitational centre and broadening of the XRLP, respectively. The nth moment n=0,1 is given by relations

μ0C=+IC(x)dx=I0Cand   μ1C=a

The integral widths δG and full width at half maximum FWHMC are given by relations

δC=πγCandFWHMC=2γC

The deconvolution of two signals h and g determined by Cauchy distributions is also a Cauchy distribution whose full width δC,f and FWHMC,f are given by relations

δC,f=δC,hδC,gandFWHMC,f=2δC,fE23

4.3. Generalized Fermi function

Although extensive research over the past few decades has made progress in XRLP global approximations, their complete analytical properties have not been reported in the literature. Unfortunately, most of them have complicated forms, and they are not easy to handle mathematically. Recently, as in [9,11], a simple function with a minimal number of parameters named the generalized Fermi function (GFF), suitable for minimization and with remarkable analytical properties, was presented from a purely phenomenological point of view. It is given by the relationship,

h(s)=Aea(sc)+eb(sc)E24

where A, a, b, c are unknown parameters. The values A, c describe the amplitude and the position of the peak, and a, b control its shape. If b=0, the h function reproduces the Fermi-Dirac electronic energy distribution. The GFF has remarkable mathematical properties, with direct use in determining the moments, the integral width, and the Fourier transform of the XRLP, as well as the true sample function. Here we give its properties without proofs.

  1. By setting

s'=scρ=(a+b)/2q=(ab)/2

we obtain

h(s')=A2(coshqs'+sinhqs'coshρs')E25
  1. the limit of h function for infinite arguments is finite, so limh(s')=0 when s'± ;

  2. the zero, first and second order moments (µ0, µ1, µ2) of the h function are given by the relations

μ0=πA2ρcosπq2ρ,μ1=π2ρtanπq2ρ,μ2=(π2ρ)2(1cos2πq2ρ+tan2πq2ρ)
  1. the integral width δh(a, b) of the h function has the following form

δh(a,b)=π(aabb)1/(a+b)cos(π2aba+b)E26
  1. the Fourier transform of the h function is given by the relationship

H(L)=A2+coshqs'+sinhqs'coshρs'e2πs'Lds'=πA2ρ|cos(πq2ρ+iπ2Lρ)|2cos(πq2ρiπ2Lρ)E27
  1. if we consider the functions f and g defined by equation (25), by their deconvolution we can compute the |F(L)| function, which is used in Warren and Averbach’s analysis in [12]. Therefore, the magnitude of F(L) function has the following form:

|F(L)|=AhρgAgρhcos2α+sinh2βLcos2γ+sinh2δL,E28

where the arguments of trigonometric and hyperbolic functions are expressed by

α=πqg2ρg,β=π2ρg,γ=πqh2ρh,δ=π2ρh

The subscripts g and h refer to the instrumental and experimental XRLP. Taking into account the convolution theorem, the true sample function f is given by the relationship

f(s)=AhρgAgρh+cos(πqg2ρg+iπ2Lρg)cos(πqh2ρh+iπ2Lρh)exp(2πiLs)ds

The last integral cannot be accurately resolved. In order to do so we have to consider some arguments. The Fourier transform of f is the F function, given by the relations

F(L)=|F(L)|exp(iθ(L)),θ(L)=arctan(F(L))(F(L))

where θ means the angle function, and (F) and (F) are the real and imaginary parts of the complex function F, respectively. The arguments α, β, γ and δ from equation (28) depend only on the asymmetry parameters a and b of the g and f functions. If the XRLP asymmetry is not very large (i.e., a and b parameters are close enough as values) the cos2α1, cos2γ1 approximations are reliable. Therefore, we obtain (F)<<(F), θ(L) ≈ 0 and the magnitude of the Fourier transform for the true XRLP sample can be expressed as

|F(L)|=AhρgAgρhcoshπ2Lρgcoshπ2LρhE29

(vii) if we consider the previous approximation, the true XRLP sample is given by an inverse Fourier transform of the F function, and consequently we have

f(s')=2AhρgπAgcosπρh2ρgcoshρhs'cosh2ρhs'+cosπρhρgE30

(viii) the integral width of the true XRLP sample can be expressed by the δf function

δf(ρh,ρg)=π2ρhcosπρh2ρg(cosπρhρg+1)E31

4.4. Voigt distribution applied in X-ray line profile analysis

Before briefly describing the mathematical properties of the Voigt distribution, let us examine the physical concept underlying the approximation of the XRLP by Voigt distribution and the convolution process.

During decades of research, Warren and Averbach [12] introduced the X-ray diffraction concept for the mosaic structure model, in which the atoms are arranged in blocks, each block itself being an ideal crystal, but with adjacent blocks that do not accurately fit together. They considered that the XRLP h represents the convolution between the true sample f and the instrumental function g, produced by a well-annealed sample. The effective crystallite size Deff and lattice disorder parameter hkl> were analysed as a set of independent events in a likelihood concept. Based on Fourier convolution produced between f and g signals and the mosaic structural model, the analytical form of the Fourier transform for the true sample function was obtained. The normalized F was described as the product of two factors, F(s)(L)  and F(ε)(L) , where variable L represents the distance perpendicular to the (hkl) reflection planes. The factor F(s)(L)  describes the contribution of crystallite size and stocking fault probability, while the factor F(ε)(L)  gives information about the microstrain of the lattice. The general form of the Fourier transform of the true sample for cubic lattices was given by relationships

F(s)(L)=e|L|Deff(hkl),F(ε)(L)=e2π2εL2hklh02L2a2,E32

where h02=h2+k2+l2. The general form of the true sample function f is given by inverse Fourier transform of F(L)

f(s)=eβL2γ|L|e2πisLdL==πβexp[γ2(2πs)24β]{(erfc(γ2πis2β))cosπγsβ(erfc(γ+2πis2β))sinπγsβ}E33

where s=2(sinθλsinθ0λ), erf(x)=2π0xet2dt, erfc(x)=1erf(x) is the complementary error function [13] and β=2π2εL2hklh02a2,γ=1Deff(hkl). The last relation from the mathematical point of view represents a Voigt distribution. If we take into account the properties of the Gauss and Cauchy distributions, the Voigt distribution can be generalized by relation

V(x,γG,γC)=+IG(x',γG,x0G)IC(xx',γC,x0C)dx'E34

Based on relation (18), its Fourier transform is given by FT[V]=FT[IG]FGFT[IC]FC where

FG(L)=e2πix0GLeπ2γG2L2andFC(L)=e2πix0CL2πγC|L|

The analytical expression of the Voigt distribution is

V(x,γG,γC)=FT1[e2πi(x0C+x0G)Leπ2γG2L22πγC|L|]E35

Explicit forms of experimental signal and true sample function normalized at I0V are given by relations [13]

V(x,γG,γC)=I0VπγGexp[γC2(xx0Cx0G)2γG2]{[erfc(γCi(xx0Cx0G)γG)]cos2γC(xx0Cx0G)γG2[erfc(γC+i(xx0Cx0G)γG)]sin2γC(xx0Cx0G)γG2}E36

and

Vf(x,γG,f,γC,f)=1πγC,fexp[γC,f2(xx0Cx0G)2γG,f2]{[erfc(γC,fi(xx0Cx0G)γG,f)]cos2γC,f(xx0Cx0G)γG,f2[erfc(γC,f+i(xx0Cx0G)γG,f)]sin2γC(xx0Cx0G)γG,f2}E37

Maximum value of true sample function is

Vmax=1πγGexp(γC2γG2)erfc(γCγG)

Voigt function is a probability density function and it displays the distribution of target values,

V(x,γG,γC)dx=1ππγCγG[e(x'γG)2γC2+(xx)2dx]dx=1,δV=πγGexp(γCγG)2erfc(γCγG)E38

and the convolution of two Voigt functions is also a Voigt function.

The integral width of a true sample function has the two components given by the Gauss and Cauchy contributions

δG,f2=1π(δG,h2δG,g2),δC,f=1π(δC,hδC,g)E39

Balzar and Popa are among the leading scientists in the field of Fourier analysis of X-ray diffraction profiles, and they suggested that each Gauss and Cauchy component contains information about the average crystallite size (δS) and distortion of the lattice (δD) as in [14]. From the algebraic point of view, they proposed the following relationship

δG,f2=δSG,f2+δDG,f2,δC,f=δSC,f+δDC,fE40

Based on the new concept introduced by them, the two components of the Fourier transform are given by the relations

FS(L)=eπL2δSG,f22|L|δSC,f,FD(L)=eπL2δDG,f22|L|δDC,fE41

The particle size distribution function, P(L) is determined from the second derivative of strain-corrected Fourier transform of the true sample function. The volume-weighted column-length PV and surface-weighted column-length PS distributions are given by the following [14]:

PV(L)=Ld2FS(L)dL2=2L[2(πLδSG2+δSC)2πδSG2]FS(L)E42
PS(L)=PV(L)=d2FS(L)dL2=2[2(πLδSG2+δSC)2πδSG2]FS(L)E43
Advertisement

5. Experimental section, data analysis and results

A series of four supported gold catalysts were studied by X-ray diffraction (XRD) in order to determine the average particle size of the gold, the microstrain of the lattice as well as the size and microstrain distribution functions by XRLP deconvolution using Fourier transform technique. The gold catalyst samples with up to 5 wt% gold content were prepared by impregnation of the SiO2 support with aqueous solution of HAuCl4×3H2O and homogeneous deposition-precipitation using urea as the precipitating agent method, respectively. The X-ray diffraction data of the supported gold catalysts displayed in Figure 3 were collected using a Rigaku horizontal powder diffractometer with rotated anode in Bragg-Brentano geometry with Ni-filtered Cu Kα radiation, λ = 1.54178 Å, at room temperature. The typical experimental conditions were: 60 sec for each step, initial angle 2θ = 320, and a step of 0.020, and each profile was measured at 2700 points. The XRD method is based on the deconvolution of the experimental XRLP (111) and (222) using Fourier transform procedure by fitting the XRLP with the Gauss, Cauchy, GFF and Voigt distributions. The Fourier analysis of XRLP validity depends strongly on the magnitude and nature of the errors propagated in the data analysis. The scientific literature treated three systematic errors: uncorrected constant background, truncation, and effect of sampling for the observed profile at a finite number of points that appear in discrete Fourier analysis. In order to minimize propagation of these systematic errors, a global approximation of the XRLP is adopted instead of the discrete calculus. The reason for this choice was the simplicity and mathematical elegance of the analytical Fourier transform magnitude and the integral width of the true XRLP given by equations (20)-(24), (31), (34) and (38), as in [15]. The robustness of these approximations for the XRLP arises from the possibility of using the analytical forms of the Fourier transform instead of a numerical fast Fourier transform (FFT). It is well known that the validity of the numerical FFT depends drastically on the filtering technique what was adopted in [16]. In this way, the validity of the nanostructural parameters is closely related to the accuracy of the Fourier transform magnitude of the true XRLP.

Experimental relative intensities (111) with respect to 2θ values for (1) system are shown in Figure 4. The next steps consist in background correction of XRLP by polynomial procedures, finding the best parameters for the distributions adopted using the method of least squares or nonlinear fit, and then deconvoluting them using instrumental function. The main steps in the data analysis of the investigated systems are shown in Figure 4.

Figure 4.

Various stages of processing for X-ray line profile (111) of the sample (1)

Experimental relative intensities (222) with respect to 2θ values for (6) system are shown in Figure 5.

The Fourier transforms normalized for the true sample function of the investigated samples (1) and (6) were calculated by three distinct methods, based on relations (28), (32) and (41), and are displayed in Figure 6.

The microstrain and particle size distribution functions determined by Fourier deconvolution of a single XRLP were calculated using equation (32), and are plotted in Figure 7.

The credibility of the parameters describing the investigated nanostructure systems depends primarily on the process of approximation of XRLP. This criterion is expressed by the root mean squares of residuals (rmsr) of data analysis and is given by relation

rmsr=100i=1Npoints(yicalcyiexp)2σi2NpointsNparam

Figure 5.

Various stages of processing for X-ray line profile (222) of the sample (6)

Figure 6.

Fourier transform of true sample function of XRLP (111) and (222) for systems (1) and (6): blue - general relation, red - GFF, green - Voigt distribution

The rmsr values for all distributions used in XRLP approximation process are given in Table 1. The rmsr values are closely related to the spectral noise of experimental data. Here it is shown that a model based on GFF and Voigt distribution may be more realistic and accurate.

The integral widths and FWHM of the true sample functions calculated for all distributions were determined using the relations (21), (23), (31) and (38). Their values are presented in Table 2.

Figure 7.

Size and microstrain distribution functions of (111) XRLP for system (1)

Sample hkl Distribution
GFF Gauss Cauchy Voigt
(1) 111 26.2658 47.6477 40.6091 26.9398
222 14.8795 15.2648 16.0429 15.1880
(3) 111 21.5743 31.4428 28.0142 22.1633
222 12.5725 12.4615 12.6212 12.4534
(5) 111 18.1273 26.6941 21.8148 17.4276
222 13.2033 13.3122 13.2599 13.2771
(6) 111 28.1267 31.8679 36.0040 35.5948
222 18.8487 20.5945 33.2718 19.9656

Table 1.

Values for rmsr for investigated samples

Because the experimental XRLP was measured for both (111) and (222), the surface-weighted column-length PS and volume-weighted column-length PV distribution functions were determined using relations (42,43) implemented in BREADTH software [17]. Additionally, it has found that the Gumbel distribution is the most adequate function for the global approximation of both probabilities’ curves, and the results are shown in Figure 8.

The global structural parameters obtained for the investigated samples are summarized in Table 3 and Table 4.

Sample hkl 0
[Deg]
Distributions
GFF Gauss Cauchy Voigt
δ
[Deg]
a*
[Deg]
δ
[Deg]
a*
[Deg]
δ
[Deg]
a*
[Deg]
δ
[Deg]
a*
[Deg]
(1) 111 38.291 0.644 0.540 0.638 0.599 0.738 0.469 0.713 0.537
222 81.780 0.862 0.715 0.854 0.803 1.025 0.653 0.927 0.765
(3) 111 38.220 0.802 0.672 0.798 0.750 0.919 0.585 0.891 0.668
222 81.763 1.028 0.860 1.011 0.950 1.181 0.752 1.095 0.912
(5) 111 38.211 0.631 0.529 0.621 0.583 0.723 0.460 0.701 0.519
222 81.801 1.052 0.873 1.067 1.003 1.225 0.780 1.185 0.890
(6) 111 38.292 0.363 0.304 0.363 0.341 0.426 0.271 0.374 0.335
222 81.872 0.506 0.423 0.498 0.468 0.613 0.390 0.528 0.461

Table 2.

Values for integral width and full width at half maximum for investigated samples

a* represents FWHM


Figure 8.

Surface-weighted column-length distribution function, PS, and volume-weighted column-length distribution function, PV, for (5) and (6) systems

Sample GFF approximation Single Voigt approximation
D111Sch D111 D222Sch D222 D111Sch D111 D222Sch D222
(1) 180 168 180 139 145 154 118 145
(3) 143 135 139 130 116 118 98 139
(5) 183 171 145 112 153 151 108 95
(6) 398 309 313 263 249 384 199 303

Table 3.

Values for crystallite size determined by Scherrer method, and effective crystallite size using single XRLP approximations

Sample hkl DS±ΔDS
[Å]
DV±ΔDV
[Å]
ε2(DV/2)1/2±Δε2(DV/2)1/2
(1) [111/222] 90±12 133±15. 0.211E-02 ± 0.152E-03
(3) [111/222] 69±13 104± 17 0.262E-02 ± 0.288E-03
(5) [111/222] 106±30 153±41 0.280E-02 ± 0.216E-03
(6) [111/222] 214±72 233±79 0.105E-02 ± 0.522E-03

Table 4.

Values for the average crystallite size and microstrain using double Voigt approaches

Hydrogen chemisorption, transmission electron microscopy (TEM), magnetization, electronic paramagnetic resonance (EPR) and other methods could also be used to determine the average diameter of particles by taking into account a prior spherical form for the grains. By XRD method we can obtain the crystallite sizes that have different values for different crystallographic planes. There is a large difference between the particle size and the crystallite size due to the different physical meaning of the two concepts. It is possible that the particles of the supported gold catalysts are made up of many gold crystallites.

The size of the crystallites determined by equations (32) and (41), corresponding to (111) and (222) planes, have different values. The crystallite sizes D111Sch and D222Sch are determined by the Scherrer method [18] without taking into account the microstrain of the lattice. The values D111 and D222 were determined by Fourier deconvolution method for single XRLP, while the averages of DV and DS were calculated by a double Voigt approach. The difference between the crystallites’ size can be explained by the fact that the analytical models are different due to the different approaches. This means that the geometry of the crystallites is not spherical [18]. The microstrain parameter of the lattice can also be correlated with the effective crystallite size in the following way: the value of the effective crystallite size increases when the microstrain value decreases.

The main procedures of the SIZE.mws software dedicated to Fourier analysis of the XRLP by GFF and Voigt distributions written in Maple 11 language are presented in Appendix 2.

Advertisement

6. Conclusions

In the present chapter, it is shown that XRD analysis provides more information for understanding the physical properties of nanomaterial structure. Powder X-ray diffraction is the cheapest and most reliable method compared with hydrogen chemisorptions, TEM techniques, magnetic measurements, EPR, etc. The main conclusions that can be drawn from these studies are:

  1. For XRLP analysis, a global approximation should be applied rather than a numerical Fourier analysis. The former analysis is better than a numerical calculation because it can minimize the systematic errors that could appear in the traditional Fourier analysis.

  2. Our numerical results show that by using the GFF and the Voigt distribution we successfully obtained reliable global nanostructural parameters;

  3. Cauchy and Gauss distributions used for XRLP approximation give roughly structural information;

  4. Powder X-ray diffraction gives the most detailed nanostructural results, such as: average crystallite size, microstrain, and distribution functions of crystallite size and microstrain;

  5. Surface-weighted domain size depends only on Cauchy integral breadth, while volume-weighted domain size depends on Cauchy and Gauss integral breadths;

  6. To obtain valid structural results, it is important to have: a good S/N ratio of the experimental spectra, a good deconvolution technique for the experimental and instrumental spectra, and an adequate computer package and programs for data analysis.

Advertisement

Appendix 1

Input data h.txt and g.txt files

`k`:=1; line_h:= readline(`h.txt`): line_g:= readline(`g.txt`): while line <> 0 do temp_h:= sscanf(line_h,`%8f%8f`):temp_g:=sscanf(line_g,`%8f %8f`): printf(`%10.5f %10.5f`,temp_h[1],temp_h[2]): lprint(): printf(`%10.5f %10.5f`,temp_g[1],temp_g[2]): lprint(): twotheta_h[`k`]:=temp_h[1]; intensity_h[`k`]:=temp_h[2]; twotheta_g[`k`]:=temp_g[1]; intensity_g[`k`]:=temp_g[2]; line_h:= readline(`h.txt`): line_g:= readline(`g.txt`): `k`:=`k`+1; end do; `k`:=`k`-1; p_h:=plot([twotheta_h[`ih`],intensity_h[`ih`],`ih`=1..k],color=red,style=LINE,thickness=2,axes=boxed,gridlines, labels=["2theta",""]): p_g:=plot([twotheta_g[`ig`],intensity_g[`ig`],`ig`=1..k],color=blue,style=LINE,thickness=2,axes=boxed,gridlines, labels=["2theta",""]): display({p_h,p_g}); deltatwotheta:=twotheta_h[2]-twotheta_h[1]:

h vector determination

twok:=2*k; for `i` from 1 to k do h[`i`]:=intensity_h[`i`]: end do: h[`k`+1]:=0: `j`:=1: for `i` from `k`+2 to twok+1 do h[`i`]:=intensity_h[`j`]: `j`:=`j`+1: end do: print(h);

g array determination

`j`:=1: for `i` from -twok to -k do g[`i`]:=intensity_g[`j`]: `j`:=`j`+1; end do: `j`:=1: for `i` from -k to -1 do g[`i`]:=intensity_g[`j`]: `j`:=`j`+1: end do: g[0]:=0.: for `i` from 1 to k do g[`i`]:=intensity_g[`i`]: end do: `j`:=1: for `i` from k+1 to twok do g[`i`]:=intensity_g[`j`]: `j`:=`j`+1: end do: print(g):

a matrix determination

for `i` from 1 to twok+1 do for `j` from 1 to twok+1 do a[`i`,`j`]:=0.: end do: end do: `i1`:=0: for `i` from -k to k do `j1`:=0: `i1`:=`i1`+1: for `j` from -k to k do `j1`:=`j1`+1: a[`i1`,`j1`]:=g[`i`-`j`]*deltatwotheta; end do: end do: print(a);

solving integral deconvolution equation by direct discretization

f:=linsolve(a,h): for `i` from 1 to twok+1 do twotheta_f[`i`]:=twotheta_h[1]+(`i`-1)*deltatwotheta: intensity_f[`i`]:=eval(f[`i`]); end do: p_h:=plot([twotheta_h[`ihh`],intensity_h[`ihh`],`ihh`=1..k],color=red,style=LINE,thickness=2,axes=boxed,gridlines,labels=["2theta",""]): p_g:=plot([twotheta_g[`igg`],intensity_g[`igg`],`igg`=1..k], color=blue,style=LINE,thickness=2,axes=boxed,gridlines, labels=["2theta",""]): p_f:=plot([twotheta_f[`iff`],intensity_f[`iff`],`iff`=1..twok+1], color=green,style=LINE,thickness=2,axes=boxed,gridlines, labels=["2theta",""]): display({p_h,p_g,p_f}); fd:= fopen("f",WRITE,TEXT): for `i` from 1 to k do fprintf(fd,"%g %g\n",twotheta_f[`i`],intensity_f[`i`]): end do: fclose(fd):
Advertisement

Appendix 2

Fourier transform of true sample function procedure

f_GFF_freq:=proc(freq) local arg_in,arg_sa; arg_in:=(Pi*q_in)/(2*rho_in) + I *(Pi*Pi*freq)/rho_in; arg_sa:=(Pi*q_sa)/(2*rho_sa) + I * (Pi*Pi*freq)/rho_sa; (ampl_sa/ampl_in)*(rho_in/rho_sa)*cos(arg_in)/cos(arg_sa); end:

Module of Fourier transform of true sample function procedure

FT_GFF_modul:=proc(freq) local aux,bux,auxr_0,auxi_0; aux:=evalc(Re(f_GFF_freq(freq))): bux:=evalc(Im(f_GFF_freq(freq))): aux:=aux*aux+bux*bux: auxr_0:=evalc(Re(f_GFF_freq(0))): auxi_0:=evalc(Im(f_GFF_freq(0))): bux:=auxr_0*auxr_0+auxi_0*auxi_0: sqrt(aux/bux): end:

True sample function procedure

f_GFF_s:=proc(s) local arg1,arg2; arg1:=(Pi/2)*(rho_sa/rho_in); arg2:=(rho_sa*s); (2/Pi)*(ampl_sa/ampl_in)* rho_in*cos(arg1)*cosh(arg2)/(cosh(2*arg2)+cos(2*arg1)); end:

Integral width of true sample function procedure

int_width_GFF:=proc(rho_in,rho_sa) local arg; arg:=Pi*rho_sa/rho_in; Pi/(2*rho_sa*cos(arg/2))*(cos(arg)+1); end:

Moment of zero order for experimental X-ray line profile procedure

mu_0_GFF:=proc(ampl,rho,q) local arg; arg:=(Pi*q)/(2*rho); (ampl/2)*(Pi/rho)*(1/cos(arg)); end:

Moment of first order for experimental X-ray line profile procedure

mu_1_GFF:=proc(rho,q) local arg; arg:=(Pi*q)/(2*rho); (Pi/(2*rho))*tan(arg); end:

Moment of second order for experimental X-ray line profile procedure

mu_2_GFF:=proc(rho,q) local arg; arg:=(Pi*q)/(2*rho); ((Pi/(2*rho))^2)*(1./(cos(arg)^2)+tan(arg)^2); end:

Experimental X-ray line profile procedure approximated by GFF distribution

exp_profile_GFF:=proc(s) local arg_q,arg_rho; arg_q:=q*s; arg_rho:=rho*s; (ampl/2)*(cosh(arg_q)+sinh(arg_q))/cosh(arg_rho); end:

Instrumental X-ray line profile procedure determined by GFF distribution

inst_profile_GFF:=proc(s) local arg_q,arg_rho; arg_q:=q_in*s; arg_rho:=rho_in*s; (ampl_in/2)*(cosh(arg_q)+sinh(arg_q))/cosh(arg_rho); end:

Fourier transform procedure for general relation of true sample function developed by Warren-Averbach theory

gen_function:=proc(freq) exp(-beta_gen(fmin,fmax)*freq*freq- gama_gen(fmin,fmax)*abs(freq)); end:

Procedure for experimental XRLP given by Voigt approximation

h_Voigt_function:=proc(s) local arg1,arg2,arg3,arg4; arg1:=(gama_h_c**2-s**2)/(gama_h_g**2); arg2:=(gama_h_c-I*s)/gama_h_g; arg3:=(gama_h_c+I*s)/gama_h_g; arg4:=2.*gama_h_c*s/(gama_h_g**2); amp_h/(sqrt(Pi)*gama_h_g)*exp(arg1)* (Re(erfc(arg2))*cos(arg4)-Im(erfc(arg3))*sin(arg4)); end:

Procedure for instrumental XRLP given by Voigt approximation

g_Voigt_function:=proc(s) local arg1,arg2,arg3,arg4; arg1:=(gama_g_c**2-s**2)/(gama_g_g**2); arg2:=(gama_g_c-I*s)/gama_g_g; arg3:=(gama_g_c+I*s)/gama_g_g; arg4:=2.*gama_g_c*s/(gama_g_g**2); amp_g/(sqrt(Pi)*gama_g_g)*exp(arg1)* (Re(erfc(arg2))*cos(arg4)-Im(erfc(arg3))*sin(arg4)); end:

Procedure for the true sample function calculated by Voigt approximation

f_Voigt_function:=proc(s) local arg1,arg2,arg3,arg4; arg1:=(gama_f_c**2-s**2)/(gama_f_g**2); arg2:=(gama_f_c-I*s)/gama_f_g; arg3:=(gama_f_c+I*s)/gama_f_g; arg4:=2.*gama_f_c*s/(gama_f_g**2); amp_h/amp_g/(sqrt(Pi)*gama_f_g)*exp(arg1)*(Re(erfc(arg2))*cos(arg4)- Im(erfc(arg3))*sin(arg4)); end:
Advertisement

Acknowledgments

Financial support received from the European Union through the European Regional Development Fund, Project ID 1822/SMIS CSNR 48797 CETATEA, is gratefully acknowledged. In particular, one of the topics covered by the book Fourier Transform of the Signals will be a useful starting point in accomplishing one of its major objectives, energy recovery from ambient pollution. Additionally, the authors are grateful to the staff of Beijing Synchrotron Radiation Facilities for beam time and for their technical assistance in XRD measurements.

References

  1. 1. Kabanikin S. Inverse and Ill-Posed Problems: Theory and Applications. Berlin/Boston: Walter de Gruyter GmbH; 2011.
  2. 2. Nedelcov I. P. Improper Problems in Computational Physics. Computer Physics Communications 1972; 4(2)157-163.
  3. 3. Read R. J. Intensity Statistics in the Presence of Translational Noncrystallographic Symmetry. Acta Crystallographica Section D 2013; 69(2) 176-183.
  4. 4. Kleefeld A., Cottbus B. T. U. Numerical Results for Linear Fredholm Integral Equations of the First Kind over Surfaces in 3D. International Journal of Computer Mathematics 2010; 1(1) 1-16.
  5. 5. Naumova V., Pereverzyev S. V. Multi-penalty Regularization with a Component-wise Penalization. Inverse Problems 2013; 29(7) 1-16.
  6. 6. Kabanikin S., editor. Regularization Theory for Ill-posed Problems: Selected Topics. Inverse and Ill Posed Problems Series 58. Berlin/Boston: Walter de Gruyter GmbH; 2013.
  7. 7. Beniaminy I., Deutsch M. A Spline Based Method for Experimental Data Deconvolution. Computer Physics Communications 1980; 21(2): 271-277.
  8. 8. Fredrikze H., Verkerk P. Comment on “A spline based method for experimental data deconvolution”. Computer Physics Communications 1981; 24(1), 5-7.
  9. 9. Aldea N., Tiusan C., Zapotinschi R. A New Approach Used to Evaluation the Crystallite Size of Supported Metal Catalysts by Single X-Ray Profile Fourier Transform Implemented on Maple V. In: Borcherds P., Bubak M., Maksymowicz A., editors. 8th Joint EPS-APS International Conference on Physics Computing, PC ’96 17-21 September 1996, Krakow: Academic Computer Centre CYFRONET-KRAKOW; 1996.
  10. 10. Balzar D., Ledbetter H. J. Voigt-Function Modeling in Fourier-Analysis of Size and X-ray Diffraction Peaks-Peaks. Journal of Applied Crystallography 1993; 26(1) 97-103.
  11. 11. Aldea N., Gluhoi A., Marginean P., Cosma C., Yaning X. Extended X-Ray Absorption Fine Structure and X-Ray Diffraction Studies on Supported Nickel Catalysts. Spectrochimica Acta Part 2000; 55(7) 997-1008.
  12. 12. Aldea N., Barz B., Pintea S., Matei F. Theoretical Approach Regarding Nanometrology of the Metal Nanoclusters Used in Heterogeneous Catalysis by Powder X-Ray Diffraction Method. Journal of Optoelectronics and Advanced Materials 2007; 9(10) 3293-3296.
  13. 13. Gradstein I. S., Rijik L. M. Tables of Integrals, Sums, Series, and Products. Moscow: Fizmatgiz; 1962.
  14. 14. Balzar D., Popa N. C. Crystallite Size and Residual Strain/Stress Modeling in Rietveld Refine. In: Meittemeijer E. J., Scardi P., editors. Diffraction Analysis of the Microstructure of Materials. Berlin Heidelberg New York: Springer-Verlag; 2003, pp. 125-144.
  15. 15. Lazar M., Valer A., Pintea S., Barz B., Ducu C., Malinovschi V., Xie Yaning Aldea N. Preparation and Structural Characterization by XRD and XAS of the Supported Gold Catalysts. Journal of Optoelectronics and Advanced Materials 2008; 10(9) 2244-2251.
  16. 16. Walker J. S. Fast Fourier Transform. 2nd ed. New York, London, Tokyo: Boca Raton CRC; 1997.
  17. 17. Balzar D. BREADTH- a Program for Analyzing Diffraction Line Broadening. Journal of Applied Crystallography 1995; 28(2) 244-245.
  18. 18. Rednic V., Aldea N., Marginean P., Rada M., Bot A., Zhonghua W., Zhang J., Matei F. Heat Treatment Influence on the Structural Properties of Supported Ni Nanoclusters. Metals and Materials International 2014; 20(4) 641-646.

Written By

Adrian Bot, Nicolae Aldea and Florica Matei

Submitted: 30 September 2014 Published: 03 June 2015