Open access peer-reviewed chapter

Foreign Intravascular Object Embolization and Migration: Bullets, Catheters, Wires, Stents, Filters, and More

Written By

Thomas R. Wojda, Stephen D. Dingley, Samantha Wolfe, W. T. Hillman Terzian, Peter G. Thomas, Daniel Vazquez, Joan Sweeney and Stanislaw P. Stawicki

Submitted: 14 February 2017 Reviewed: 21 February 2017 Published: 21 June 2017

DOI: 10.5772/68039

From the Edited Volume

Embolic Diseases - Unusual Therapies and Challenges

Edited by Michael S. Firstenberg

Chapter metrics overview

1,726 Chapter Downloads

View Full Metrics

Abstract

Foreign intravascular object embolization (FIOE) is an important, yet underreported occurrence that has been described in a variety of settings, from penetrating trauma to intravascular procedures. In this chapter, the authors will review the most common types of FIOEs, including bullet or “projectile” embolism (BPE), followed by intravascular catheter or wire embolization (ICWE), and conclude with intravascular noncatheter object (e.g., coil, gelatin, stent, and venous filter) migration (INCOM). In addition to detailed topic-based summaries, tables highlighting selected references and case scenarios are also presented to provide the reader with a resource for future research in this clinical area.

Keywords

  • intravascular emboli
  • iatrogenic injury
  • penetrating trauma
  • bullet injury
  • coil migration
  • intravascular device embolization
  • catheter or wire embolization

1. Introduction

Both traumatic and iatrogenic foreign intravascular object emboli (FIOE) have been described in the literature [13]. Traumatic bullet or “projectile” emboli (BPE) are mostly secondary to bullets or bullet fragments [1, 4, 5], with various types of shrapnel contributing to a smaller number of total cases [6]. In general, smaller caliber projectiles such as shot gun pellets are among the most common BPEs [8]. Iatrogenic FIOE are usually due to venous catheter dislodgement and retained guidewire migration [8, 9]. Such intravascular or wire embolization (ICWE) events continue to occur despite increased emphasis on patient safety and adverse event prevention [10]. As increasingly complex endovascular procedures are becoming commonplace, reports of various types of intravascular objects (e.g., stents, coils, gelatin, and filters) migrating or embolizing to anatomically remote sites have been published [1116]. Collectively, we have included the latter heterogeneous group of events under the umbrella term “intravascular noncatheter object migration” (INCOM).

The treatment of FIOE has evolved significantly over the last two decades, largely due to advances in endovascular therapeutics. Percutaneous intravascular techniques have become the gold standard in most situations, with surgery serving largely as a last-resort rescue option. Clinical management of FIOE is highly individualized and patient specific. Healthcare providers should be aware of major therapeutic options and any potential pitfalls. This chapter reviews FIOEs by type, specific complications, and clinical management. We will also discuss the most commonly encountered types of intravascular FIOEs, including BPEs, ICWEs and INCOMs associated with endovascular procedures.

Advertisement

2. Bullet or projectile embolism

Bullet or “projectile” embolism (BPE, Figure 1 and Table 1) is a rare phenomenon in trauma, with approximately 300 published cases in the literature [17]. The first instance of a traumatic BPE was published by Thomas Davis in 1834, when he reported a case of a wooden fragment that embolized from the venous circulation to the right ventricle in a young boy [5]. A bullet embolism occurs when a small caliber, usually low velocity bullet, penetrates a single vessel wall and remains within the circulation [4]. Thus, the bullet must be of a smaller diameter than that of vessel, as well as of sufficiently low kinetic energy to traverse only one vessel wall and come to rest within the vascular lumen. In this context, shotgun pellets and 22-caliber bullets are the most commonly encountered projectiles [18]. Nearly all of the cases in literature involve bullets 0.38 caliber and smaller, with only one recorded case of a 0.40 caliber bullet embolism [18]. In rare cases, various fragments of shrapnel have been found to embolize as well [6, 19, 20].

Figure 1.

Computed tomography showing a 5 mm bullet that embolized to the left lower lobe pulmonary artery, causing a pulmonary infarction (a = lung window images; b = bone window images). Source: Duke et al. [1]. Images used under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike License (CC BY-NC-SA), which permits noncommercial use, distribution, and reproduction in any medium, provided the original work is properly cited.

AuthorPatient dataCourse of projectileType of embolizationIntervention
Carter [4]22-y/o M shot in the RLQRight external iliac vein to the left common iliac veinVenousEndovascular
Duke [1]25-y/o M shot in the left faceTravelled from right jugular vein to the left lower pulmonary arteryVenousNonoperative
Huang [32]19-y/o M, shot in the backAbdominal aorta at the level of the celiac artery and travelled to the L popliteal arteryArterialEndovascular
Koirala [6]36-y/o M who sustained hammer injuryPatient presented 9 days after a hammer injury left a piece of metal lodged in his R thigh. Following operative exploration of the wound in the Trendelenburg position, the object embolized to his mediastinum, lodging at the SVC-aygos junctionVenousSternotomy, with azygous venotomy and projectile retrieval
Lu [22]20-y/o M shot in the right buttockRight internal iliac vein to right middle lobe pulmonary arteryVenousOpen, after failure of endovascular
Manganas [20]39-y/o M presented with massive hemoptysis 30 years after shrapnel blast injury to R chestPatient sustained a remote shrapnel blast injury as a 9-y/o and presented with massive hemoptysis requiring emergency surgeryTraumatic arteriovenous malformationCombined intervention; Emergency double lumen endobronchial intubation, arteriography with embolization, and R lower lobectomy
Miller [5]22-y/o M shot in the left chestThrough the left hemidiaphragm into the external iliac vein, and was found in suprahepatic vena cavaVenousEndovascular
Miller [5]52-y/o M shot in midabdomenIVC above bifurcation of iliac veins, was found in the right ventricleVenousEndovascular
Nolan [33]46-y/o M shot in RUQ abdomenInfrarenal IVC and travelled to the retrohepatic IVC, retracted into proximal R hepatic vein. It then migrated back to IVC and embolized retrograde to the left common iliac veinVenousEndovascular
Padula [28]32-y/o F who sustained abdominal GSWFollowing gunshot wounding in 1952, the patient presented in 1966 with bullet embolism to the heart. Initially (1952) the bullet was lodged in the pelvis, and subsequently became fixated to the annulus of the tricuspid valve. In 1966, she developed acute cough and feversVenousCardiotomy under cardiopulmonary bypass was performed to retrieve the bullet
Pan [24]19-y/o M shot in the LLQ of the abdomenAbdominal aorta and gained access to the IVC through an aorto-caval fistula. It was found in the right ventricleParadoxicalOpen approach
Ranvier [23]20-y/o M shot in right buttockRight internal iliac vein to the right middle lobe pulmonary arteryVenousNonoperative, after failure of endovascular
Schroeder [27]19-y/o M shot in right chestRight brachiocephalic vein, travelled to the left internal iliac veinVenousEndovascular
Stallings [18]23-y/o M shot in the right shoulderBullet travelled from axillary vein to the right ventricleVenousOpen, after failed endovascular
Yamanari [26]39-y/o M shot in the left buttockLeft external iliac vein, travelling to the left pulmonary arteryVenousNonoperative, after failed endovascular
Yordanov [34]14-y/o F shot in the right neckExternal right jugular vein to superior vena cava to inferior vena cava and into the intrahepatic venous systemVenousOpen approach

Table 1.

Summary of selected literature reports involving bullet or projectile embolization.

Entries listed in alphabetical order, based on first author’s name.

Several diagnostic findings should prompt suspicion of a BPE. An inconsistent number of entry and exit wounds may be indicative of a retained bullet or projectile. The possibility of an intravascular location of this retained object should be considered when there is no clinical or radiographic evidence of the projectile at any place along the expected course, or if the bullet is found at a distant or inappropriate location based on this trajectory. Additionally, a “migrating projectile” found in different locations on serial or repeat imaging should prompt suspicion of BPE [5].

Most BPEs are arterial (80%) with only 20% being venous [5]. Arterial emboli travel in the direction of blood flow and eventually become lodged in distal vessels, with the potential for resultant end-organ or extremity ischemia and thrombosis [21]. Approximately 80% of arterial emboli are symptomatic due to acute vessel occlusion. Consequently, arterial BPEs are more likely to have early and acute clinical presentation that requires urgent procedural intervention [22]. Surgical BPE removal is considered to be the gold standard, with both open and endovascular techniques described [23].

Venous emboli also generally travel in the direction of blood flow. However, exceptions to this rule do exist. In an estimated 15% of instances, a bullet in the venous system will embolize in retrograde fashion and travel in peripheral direction under the effects of gravity [24]. Even less common, a projectile may become a “paradoxical” embolus if it enters the venous system and subsequently gains access to the arterial circulation through a traumatic arteriovenous fistula or intra-cardiac communication, such as a patent foramen ovale or ventricular septal defect [22]. The incidence of paradoxical emboli was found to be 2.4% in a review by Springer et al. [17].

As previously stated, the vast majority of venous emboli migrate in the direction of blood flow and most commonly come to rest in the pulmonary arterial system or the right heart [17, 25, 26]. A 90-year review of 120 cases of venous missile emboli compiled by Schroder et al. [27] showed that 83% eventually travelled to the right heart or pulmonary artery, and only 4% remained in the peripheral venous system. Significantly delayed venous projectile embolization has also been reported [20, 28].

Clinical consequences of venous BPE migration include pulmonary artery embolism, cardiac valve dysfunction, endocarditis, abscess formation, sepsis, thrombosis, dysrhythmias, intraventricular communications, cardiac conduction defects, tissue erosion, hemorrhage, cardiac ischemia from erosion into coronary vessels, and thrombophlebitis [5]. However, venous emboli are only symptomatic in approximately one-third of the cases, and complications from the initial injury may not occur until months, years, and even decades later [5, 20]. Therefore, treatment of venous emboli has remained controversial.

Symptomatic cases undoubtedly warrant removal, with endovascular techniques being the first line management. The danger of BPE can be exemplified by a case of an abdominal shotgun wound where pellet embolization resulted in bilateral lower extremity amputations [7]. The advent and subsequent progress in the area of endovascular interventions resulted in increased procedural safety and greater BPE retrieval success rates, as exemplified in a report from the 1980s describing removal of embolized bullet from the right ventricle [25]. Aside from previously mentioned complications of venous emboli; symptoms such as fever, pericarditis, pleural effusions, arrhythmia, and thrombi seem to favor BPE removal [5]. It has been proposed that objects >5 mm in diameter, irregularly shaped, freely mobile, or only partially embedded within the myocardium should also be considered for extraction [5].

The management of asymptomatic venous emboli is not clearly defined. In asymptomatic cases, the risk of surgical intervention involving the pulmonary artery or right ventricle must be weighed against the risk of delayed embolic or infective complications. Some authors recommend that retrieval of asymptomatic emboli should be considered only if an endovascular technique can be used, as the risks associated with invasive surgery, up to and including median sternotomy or cardiopulmonary bypass may be too high to be considered on an elective basis [5]. Moreover, existing evidence suggests that there is no significant outcome difference between patients managed operatively versus nonoperatively [29, 30]. In terms of nonoperative management approaches, it has been proposed that patients should undergo serial imaging during outpatient follow-up, with consideration of therapeutic anticoagulation and selective use of antibiotic prophylaxis [23, 31]. The treatment of BPE continues to evolve as endovascular techniques increase in popularity and become safer. BPEs are rare but well-documented occurrences in traumatology, and further studies are required to determine the most optimal clinical management strategies.

Advertisement

3. Intravascular catheter or wire embolization (ICWE)

Vascular access catheters are utilized for numerous indications including long-term antibiotic delivery, parenteral nutrition, hemodynamic monitoring, hemodialysis, infusion of chemotherapeutic agents, and administration of other medications [35, 36]. Complications of vascular access include bleeding, thrombosis, infection, pneumothorax, mechanical occlusion, and rarely, catheter dislodgement/fracture with subsequent distal embolization / migration [11, 3537]. In a study of 1500 patients with implanted venous access devices, 87% patients had no reported complications, with infection occurring in 4.8%, thrombosis in 3.2%, and catheter fracture in 0.2% cases [38]. Other studies have reported catheter fracture rates of up to 4.1% [3941]. The utilization of intravenous catheters continues to be high. Inherent to this trend is the growing number of mechanical catheter malfunctions. Therefore, it has become increasingly apparent that effective strategies for dealing with complications of mechanical malfunction, including intravascular catheter or wire embolization (ICWE) must be developed.

Early reports of ICWE date back to mid-1950s [42]. Turner and Sommers described the embolism of a polyethylene catheter that passed from the median cubital vein to the right atrium [42]. At autopsy, a large mural thrombus was discovered at the tip of the catheter with associated myocardial necrosis. In the early 1970s, Bernhardt et al. [43] reported on 28 patients with intracardiac ICWE. In that study, mortality rate was approximately 60% [43]. In 1978, Fisher published a collected series of 42 ICWE cases reporting adequate follow-up data, with associated mortality and rate of serious complications attributable to ICWE being 38 and 71%, respectively [44]. Among causes of death were cardiac tamponade secondary to myocardial perforation, thrombotic events, pulmonary embolism, sepsis, and arrhythmias. The authors emphasized the importance of early extraction of the ICWEs [44].

Several hypotheses have been proposed regarding the cause of catheter fracture. In one review of 215 cases, the so-called “pinch-off” syndrome was found to be responsible for nearly 41% of fractures (e.g., structural failures) [45]. It was thought that mechanical stress due to repetitive catheter compression and movement relative to surrounding anatomical structures (e.g., clavicle, first rib, sharp bend at the thoracic inlet, etc.) was an important factor [46]. When this “pinch-off” sign was present, physical fragmentation of the catheter was reported as many as 170–280 days after the initial placement procedure [37]. Other potential causes of fracture included catheter damage during extraction (17.7%), separation of port and catheter (10.7%), proximal or distal catheter fracturing (11.6%), and unknown reason in 19.1% of the patients [45]. It is likely that within the latter subgroup, unintentional catheter injury during placement or manipulation resulted in fragmentation, without the primary event being clearly identified. In another review of 92 cases, the most common fracture site was found to be at the physical junction of the port and catheter (84%) [40]. Other potential causes of fracture and dislocation include improper connection between the port and catheter during implantation [47] and the use of small syringes leading to elevated pressures in the system [48].

When catheters become disconnected or fractured, they may migrate to the vena cava, right atrium, right ventricle, and ultimately the pulmonary artery. Because the majority of known ICWEs are associated with acute or chronic clinical symptoms, there are many potentially undiscovered and asymptomatic ICWE occurrences. In fact, it has been reported that asymptomatic ICWEs may be seen in as many as 24–36% of cases of embolization [40, 45]. Many patients present with nonspecific complaints of increased catheter “flow resistance” during infusion, localized pain or swelling. In a review of 42 previously published cases of ICWE, only two cases (4.8%) presented with chest pain. Thirty-six percent of cases were discovered incidentally and 29% cases had localized swelling or pain [49]. Less commonly, patients experienced cardiac dysrhythmias such as ventricular tachycardia [49, 50].

Management of ICWEs has traditionally relied on surgical or interventional extraction to prevent future risk of morbidity and mortality. Relatively recent data suggest that ICWE-related mortality has declined to <2% and prompted some to call into question the aggressiveness of ICWE retrieval strategies [45]. Indeed, there have been several reports of retained catheters in asymptomatic patients for prolonged periods of time (e.g., 10–20 years after the original device placement) [3, 51]. In one case, a chronically retained ICWE lodged in bilateral pulmonary arteries was managed without procedural extraction [52]. In another report, a retained catheter dilator was present in the right ventricle outflow tract for >20 years without clinical symptoms and was removed electively during a later coronary artery bypass and aortic valve replacement operation [3].

Prior to the emergence of advanced endovascular techniques, surgery was the only means of removing centrally located ICWEs. In the mid-1960s, it was reported that nonsurgical retrieval of ICWE from the right atrium was possible [53]. Percutaneous ICWE removal has now become the preferred technique due to its high rate of success and low rate of complications [54]. Numerous authors have reported successful ICWE retrieval using a variety of endovascular approaches [5458]. In the majority of such cases, vascular access has been obtained through central veins (e.g., internal jugular, femoral, or subclavian). However, the use of peripheral intravenous access sites for retrieval has now also been reported [59]. In conclusion, if central embolization of a catheter or catheter fragment occurs and retrieval is indicated, removal should be attempted by percutaneous methods. In the event that these methods are unsuccessful, the decision to move forward with surgical removal should not be automatic. Indeed, if the catheter is unlikely to further migrate or its discovery has been purely incidental, observation with or without serial imaging may be a reasonable approach [3]. Summary of literature reports on the topic of ICWE is presented in Table 2.

StudyStudy typeEmbolic sourceComment
Bindraban [54]Case reportPort-a-cathDescription of “lasso technique” for retrieval of broken, dislocated port-a-cath fragment
Biswas [50]Case reportCentral linePercutaneous retrieval w/ triple loop snare
Cheng [40]Case seriesTIVAD92 cases. Retrieval w/ loop snare
Choksy [59]Case reportTIVADPeripheral percutaneous retrieval
Chow [9]Case seriesPICC11 pediatric cases. Nonsurgical, percutaneous retrieval
Chuang [39]Case seriesTIVAD23 dislodged catheters. Retrieval w/ pigtail and loop snare
Kalińczuk [58]Case seriesTIVAD, CVC, and Swan-Ganz catheter entanglement14 cases. Retrieval w/ pigtail and loop snare
Kim [56]Case reportTIVADPercutaneous retrieval w/ pigtail catheter and gooseneck snare
Kock [38]Case seriesTIVAD1500 patients. 0.2% catheter fracture rate
Nakabayashi [55]Case reportTIVADPercutaneous retrieval w/ pigtail catheter and gooseneck snare
Pande [57]Case reportPICCNonsurgical removal w/ flexible biopsy forceps

Table 2.

Summary of selected literature reports involving intravascular catheter or fragment embolization.

Entries listed in alphabetical order, based on first author’s name.

TIVAD, totally implantable venous access device; CVC, central venous catheter.

Advertisement

4. Intravascular guidewire migration or embolization

The use of guidewires in medical procedures to obtain safe vascular access began in the 1950s when the Swedish radiologist Sven-Ivar Seldinger introduced the practice of using flexible guidewires to place catheters into vessels [60]. Since then, the Seldinger technique has become the cornerstone of procedures such as angiography, percutaneous thoracostomy tube placement, certain PEG tube models, and lead insertion for artificial pacemakers or automatic implantable cardioverter-defibrillators [6166].

One specific procedural approach that almost all medical and surgical trainees will encounter and use is the Seldinger technique for the insertion of central venous catheters (CVC) [67]. CVC placement is usually performed for hemodynamic monitoring, vascular access, or specific treatments that require central vein access. Commonly used points of access include the neck (internal jugular vein), chest (subclavian or axillary vein), groin (femoral vein), or arm (as a peripherally inserted central catheter or “PICC line”) [35, 36].

Although there are many different types of CVCs available, the insertion process for all of them is similar. Due to limited scope of the current article, the reader is referred to other sources describing typical procedural steps of CVC placement [68, 69]. For the purposes of our discussion, there are two key safety messages: (a) if the catheter is adequately positioned, all lumens of the CVC should allow for the easy aspiration of blood from the vein and the flushing of saline (or heparin) into the vein; and (b) radiographs should be obtained as a final precaution to ensure that the CVC is not anatomically malpositioned, there is no evidence of pneumothorax or postprocedural bleeding, and to document that the guidewire has been removed [68, 69].

In addition to pneumothorax, central venous catheterization is associated with other, well-described risks, including infection, thrombosis, unintentional arterial puncture, malpositioning, nerve damage, bleeding, venous air embolism, and arrhythmias [35, 36]. It is estimated that between 15 and 33% of CVC attempts result in some sort of complication (including failure to place the CVC) [70, 71]. Specific recommendations exist regarding CVC placement and maintenance care to reduce complication rates, with special focus on eliminating catheter-associated infections [72].

One of the most unusual and poorly described complications of CVC placement is guidewire embolization (GWE, Figure 2). GWE is an iatrogenic complication estimated to occur roughly at a rate of 1–2 per several thousand CVC insertions [10, 73]. The event occurs when a guidewire migrates through the venous system causing complications such as arrhythmias, vascular injury, thrombosis, or infection. It is the direct result of a guidewire becoming lost during CVC placement by either not removing the guidewire after the procedure or failing to control the guidewire during the procedure [73].

Figure 2.

Radiographic images showing a retained guidewire spanning from the abdominal vena cava [A] to the right internal jugular vein [B]. Source: Taslimi R et al. [150]. Images used under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/3.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.

While data are lacking regarding the risk of GWE from losing a guidewire per se, guidewire loss is the only mechanism for GWE to occur and therefore key technical and procedural safety steps must be followed at all times when placing CVCs [10]. Risk factors for guidewire loss include CVCs placed by inexperienced providers, CVCs placed in emergent situations, operator inattention, inadequate supervision of trainees, and overburdened staff [10, 7476]. Selected recommendations for decreasing the likelihood of guidewire loss are listed in Table 3 [77]. All anatomic vascular access points are at risk for guidewire loss and GWE (Table 4). It is important to emphasize that GWEs may be discovered at various points in time, sometimes even years after the CVC placement procedure occurred. Listing of selected GWE cases is provided in Table 4.

Inspect the wire for defects before insertion
If resistance is met during guidewire placement, remove and inspect the guidewire for damage and replace it if needed
Make sure that the guidewire is visible on the proximal and distal ends of the catheter before advancing the catheter
Advance the catheter over the guidewire and do advance the guidewire with the catheter
Hold onto the guidewire at all times until it is removed; if necessary, clamp the end of it while advancing the catheter
Inspect the wire for complete removal at the end of the procedure and document in medical record accordingly

Table 3.

Recommendations for decreasing the chances of guidewire loss during CVC placement [77].

StudyDemographicsAccess pointComplicationsResolutionComments
Ghatak [74]60-y/o femaleNeck—Right internal jugular v.Guidewire found crossing superior and inferior vena cava junctionGrasped catheter and wire together with forceps and removed both togetherGuidewire lost when operator distracted by arrhythmia on monitor
Schummer [77]63-y/o femaleNeck—Right internal jugular v.Guidewire found within internal jugular v. extending into superior and inferior vena cavaGuidewire removed via right internal jugular v. open surgical explorationUnsupervised trainee encountered resistance while advancing the guidewire and after placing the catheter, did no know to remove the guidewire. Catheter withdrawn later while guidewire still remained in vein
Schummer [77]62-y/o maleNeck—Right internal jugular v.Guidewire found extending from right atrium to right internal jugular v.Guidewire removed using Dormia basketDistracted anesthesiologist failed to supervise trainee who never removed guidewire during catheter placement
Schummer [77]43-y/o maleNeck—Left internal jugular v.Guidewire hidden within catheter of left internal jugular v.Guidewire removed with catheter held in place by two clampsFound incidentally on X-ray within catheter
Cheddie and Singh [9]30-y/o maleChest - Right subclavian v.Migration to right external iliac v.Retrieved under fluoroscopy from cannulated right common femoral v. using snareInexperienced operator did not hold onto guidewire after inserting it excessively
Ghatak [76]40-y/o femaleChest – Right subclavian v.Guidewire found within a pre-existing catheter during hospital admissionGrasped catheter and wire together with forceps and removed both togetherGuidewire was never removed after procedure and had been advanced into vein with the catheter
Narendra and Baghavan [80]64-y/o femaleChest – Right subclavian v.Guidewire migrated down to right external iliac veinRemoved by open surgical retrievalGuidewire advanced with catheter by accident
Cheddie and Singh [9]31-y/o femaleGroin - Right femoral v.Migration to inferior vena cava and superior vena cava, and ultimately into right jugular v.Retrieved under fluoroscopy through right common femoral v. with snareEmergent trauma catheter placed where catheter accidentally advanced with guidewire
Schummer [79]68-y/o maleGroin – Left femoral v.Guidewire hidden within catheter of left femoral v.Guidewire removed after catheter removed when it was found to still be sticking outside of skinPost-procedure X-ray showed wire but it was not reported by radiologist, discovered incidentally when another catheter was placed one day later in a different body vessel
Reynen [54]53-y/o maleArm – Right cubital v.Guidewire found 14 years later with one end at the junction of the left and right pulmonary arteries and the other end in the right ventricleGuidewire flotation on fluoroscopy was absent. Wire was thought to adhered to vascular wall so extraction not attemptedDiagnosis delayed since patient had concomitant moderate chronic obstructive lung disease

Table 4.

Case series of guidewire embolisms arranged by vascular access point.

Whenever there is concern that guidewire loss may have occurred, immediate identification and remedial action is required. As obvious as this occurrence may seem when examining events retrospectively, the fact that GWEs continue to happen suggests that our current approaches are not fail-proof [79, 80]. In this context, commonly reported “red flags” suggesting guidewire loss may include: (a) the guidewire is missing at the end of case and not accounted for; (b) there is resistance to blood aspiration and saline flushing through the distal lumen; and (c) the guidewire is visible on postprocedure radiograph. In the event that guidewire loss occurs and it is not immediately retrievable at bedside, or it is discovered that GWE has occurred, it is recommended that the first basic steps in management is to anticoagulate the patient with intravenous heparin [78] and to initiate intravenous antibiotic therapy [8]. This is usually followed by procedural retrieval of the guidewire. It is critically important to honestly disclose any adverse events to the patient and his/her family.

The need for prompt procedural extraction is supported by the reports that embolic events related to guidewires are associated with complications in 49% of cases and can be fatal in up to 20% of cases [81]. In one unusual case, the guidewire disintegrated and emerged from the patient’s neck [82]. Although not strictly a study of lost guidewires, in a series of 220 ICWEs, morbidity exceeded 70% and mortality approached 40% when a catheter fragment causing embolism was not removed [44]. Not infrequently, GWEs are found incidentally on imaging [83]. With more chronic cases of guidewire retention, the foreign object may become incorporated into the vessel wall. In such circumstance, the risk of extraction may exceed the risk of continued retention, especially if there are no clinical symptoms or other manifestations. If there is any question in that regard, fluoroscopy can be performed to help guide clinical decision making. If the retained guidewire fails to exhibit “flotation” within the vessel lumen on fluoroscopy, it has likely become incorporated into the vessel wall [84].

Once the decision to remove a retained guidewire is made, the extraction is preferably performed using percutaneous endovascular techniques. However, if the GWE is in the heart or central vasculature, or if percutaneous extraction fails for any reason, thoracotomy or video-assisted thorascopic surgery may be needed [81]. Devices which have been used successfully in GWE removal (percutaneous and open) include snares, Dormia baskets, bronchoscopy forceps, and surgical hooks [52]. It is critical to remember that as the utilization of endovascular procedures increased over time so did the number of associated complications. Table 4 provides a detailed overview pertaining to the general area of GWE, including anatomic considerations, retrieval, and morbidity.

Advertisement

5. Foreign object embolization and/or migration during therapeutic procedures

This section of the chapter will discuss the uncommon yet potentially serious occurrence of FIOE associated with therapeutic interventional procedures. Various types of potential FIOEs, event types, clinical manifestations, and management options will be discussed. As previously outlined, we group this heterogeneous group of events under the umbrella term “intravascular noncatheter object migration” (INCOM). Events are categorized by general anatomic location. It is important to note that many of the reports reviewed involve device migration, and that the overlap between “migration” and “embolization” entails certain mechanistic similarities. Table 5 provides a summary of major clinical events associated with endovascular therapeutic procedures.

Neurovascular procedures. Endovascular occlusion of intracranial aneurysms is commonly performed; however, coil displacement and migration remains a problem and carries the risk of thromboembolic complications [84]. The reported rates of coil migration (Figure 3) range from 2 to 6% [85]. Coils seal the aneurysm from blood flow by inducing thrombosis within the lumen of the aneurysm. Thromboembolic complications represent the greatest risk during the endovascular treatment of an aneurysm, with displaced coil material posing significant additional risks. Protrusion, stretching, fracture or migration of a coil may occlude proximal large-caliber vessels or migrate into smaller distal vessels [86]. Moreover, the coil may migrate with blood flow into smaller-branch vessels or lodge at the bifurcation of a vessel, resulting in limitation of flow and potentially tissue hypoperfusion. Occlusion of either the main artery or distal vessel may result in a variable size territory infarct—a disabling or even fatal event [85]. The risk for coil displacement and migration is influenced by a combination of anatomic and technical factors. Both undersized and/or unstable long coils can result in distal coil migration, especially in wide-neck aneurysms [87]. Tortuous vessels and high flow velocities are thought to increase the potential for coil migration [88, 90]. The use of balloon or stent assistance reduces the risk of coil displacement and migration.

Figure 3.

Angiographic images obtained during the coiling of a posterior communicating artery aneurysm. One of the coils migrated into the distal middle cerebral artery (A), requiring the use of a Goose Neck Snare ® (black arrow, A-C) for its retrieval. The right lower image shows the coil being removed after its capture using the snare device (D). Source: Oh et al. [151]. Images used under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0/) which permits unrestricted noncommercial use, distribution, and reproduction in any medium, provided the original work is properly cited.

AuthorDevice and locationComment
Intracranial
Standard (1994) [85]Guglielmi detachable coil; anterior inferior cerebellar arteryDual guidewire technique was used to retrieve the device
Watanabe (1995) [87]Detachable coil; superior cerebellar arterySnare type endovascular retrieval device was used during retrieval
Zoarski (1997) [98]Fibered platinum microcoils; Posterior cerebral arteryAdjustable-size, nonangled microcatheter retrieval device was used
Prestigiacomo (1999) [99]Guglielmi detachable coil; Posterior inferior cerebellar arteryGoose neck snare “twist” technique was used during retrieval
Raftopoulos (2002) [118]Guglielmi detachable coil; anterior communicating arteryMinimal transarterial coil hooking procedure used during retrieval
Schutz (2005) [110]Coil fracture; Siphon internal carotid artery; posterior communicating arteryLoose end of the fractured coil was fixed with a stent at the proximal parent vessel wall
Fiorella (2005) [111]Stretched platinum coils; superior inferior cerebellar artery, middle cerebral arteryMonorail snare technique was used during the removal of platinum coils; goose neck microsnare
Henkes (2006) [119]Endovascular coil; basilar bifurcationDescription of coil retrieval using the alligator retrieval device
Vora (2008) [91]Detachable coil; vertebro-basilar systemRetrieval of displaced detachable coil and intracranial stent described using an L5 Merci device during intracranial aneurysm embolization
O’Hare (2009) [120]Migrated coil; posterior communicating arteryDescription of the use of X6 Merci Retrieval device for removing a migrated coil
Lee (2011) [121]Displaced/stretched coils; Superior inferior cerebellar arteryAuthors describe the use of wire as a snare for “rescue” endovascular recovery of displaced/stretched coils
Leslie-Mazwi (2013) [122]Displaced coil management; various intracerebral locationsAuthors describe the use of stent retriever for removal of displaced microcoils
Nas (2015) [123]Dislocated coil; internal carotid arteryDescription of the use of Solitaire® stent for retrieval of dislocated coil
Cardiovascular
Chomyn (1991) [124]Stainless Gianturco coil; right lower lobe pulmonary arteryThe authors describe the retrieval of migrated Gianturco coil from the pulmonary artery using flexible intravascular forceps
Sanchez (1992) [125]Wallstent; right atriumAuthors describe retrieval of a Wallstent misplaced during TIPS procedure using a loop snare
Berder (1993) [11]Coronary stent; Descending aortaAuthors describe retrieval of a migrated coronary stent from the descending aorta utilizing biopsy forceps and PTCA balloon
Kamalesh (1994) [126]Inferior vena cava stent; Left pulmonary arteryAuthors describe retrieval of embolized inferior vena cava stent from the left pulmonary artery; balloon catheter was used with the aid of trans-esophageal echocardiography
Bartorelli (1995) [127]Palmaz stent; right atriumAuthors describe transcatheter management of embolized Palmaz stent following superior vena cava stenting
Grosso (1995) [128]Palmaz stent; left pulmonary arteryDescription of the retrieval of dislodged Palmaz stent that occurred during TIPS procedure; the authors utilized an angioplastic balloon catheter with surgical venotomy extraction
Hoyer (1996) [129]Palmaz stent; Right ventricleThe authors describe transcatheter retrieval of a Palmaz stent embolized from the pulmonary artery to the right ventricle in a child; Retrieval and repositioning procedure is presented
Prahlow (1997) [130]Wallstent embolization; Right atrium and aortaAuthors describe a fatal complication of TIPS procedure. Embolization of Wallstent led to cardiac perforation with tamponade and death
Feghaly (1998) [2]Venous stent migration: (a) Left common iliac vein to right ventricle; and (b) Left braciocephalic vein to pulmonary arteryAuthors describe endovascular retrieval of two migrated venous stents; balloon catheter-based techniques were utilized; operative extraction from the iliac vein was performed
Marcy (2001) [131]Strecker stent; right pulmonary arteryAuthors describe long-term management of Strecker stent migration from left innominate vein to the right pulmonary artery using anticoagulation and “wait-and-see” approach
Ashar (2002) [132]Wallstent; Pulmonary arteryAuthors describe percutaneous retrieval of a wallstent from the pulmonary artery following migration from the original placement site in the iliac vein; Jugular and femoral approaches are utilized
Abdominal
Takahashi (2001) [133]Steel-wire coils; migration from splenic artery to gastric bodyReport of steel-wire coil migration into the stomach following arterial embolization of a bleeding splenic artery aneurysm
Ozkan (2002) [134]Guglielmi detachable coil; erosion from hepatic artery to CBDPatient developed pancreatitis after erosion of Guglielmi coils into the CBD, 2 years after the original hepatic artery pseudoaneurysm embolization procedure
Turaga (2006) [135]Embolization coil; Hepatic artery to CBDPatient developed ascending cholangitis due to coil migration into the CBD; Surgical intervention was required
Dinter et al. (2007) [136]Embolization coil; stomachFatal hematemesis due to coil migration into the stomach and the associated creation of aorto-gastric fistula
Reed (2007) [137]Embolization coil; aorto-venous fistula involving branch of the renal arteryEmbolization coil eroded into the collecting system and passed through patient’s urinary tract 1 year after the index procedure
Shah (2007) [138]Steel-wire coils; migration from splenic artery into the gastrointestinal tractAfter migrating from embolized splenic artery pseudoaneurysm, steel-wire coils passed via rectum
Jurałowicz (2010) [139]Embolization coil; Hepatic artery to common bile ductPatient developed life-threatening obstructive jaundice after migration of embolization coils from hepatic artery aneurysm to the biliary tree; Endoscopic removal of coils was performed
Miscellaneous
Cishek (1995) [140]Coronary artery stent; Dislodgement from coronary balloon catheter to the iliac arteryAuthors describe the use of a peripheral angioplasty balloon to withdraw the stent into the arterial sheath and then from the patient
Kiyosue (2004) [141]Intravascular coils; Coil migration from the ICA to pharynx and the external auditory canalRadiation necrosis was thought to be contributory to the observed coil migration
Chow (2002) [142]Embolization coil; migration from internal carotid artery into the middle ear and auditory canalManagement consisted of cutting the coil wire (approximately 25 cm) flush to the tympanic membrane; Patient was doing well at 18 month follow-up
Dagain (2008) [143]Endovascular coil; Erosion of a coil from ICA aneurysm into the right oculomotor nerveThe patient presented 5 years after the index procedure with progressive diplopia and ptosis; Surgical correction was performed
Choi (2016) [144]Nitinol clip; Distal migration of the clip with tibial-popliteal artery occlusionPatient developed critical ischemia of the right lower extremity following StarClose SE device deployment; Surgical embolectomy was performed to correct the problem

Table 5.

Selected reports of intravascular device/particle migration or embolization; within each anatomic location, reports are arranged alphabetically.

CBD, common bile duct; ICA, internal carotid artery.

The risk of coil prolapse, in addition to migration, is also a significant concern in endovascular treatment of cerebral aneurysms. When improperly positioned, coils may protrude out of the aneurysm neck, narrowing or occluding the parent artery. Stenting can provide further structural support when placing the coils within a specific location, but also runs the risk associated with additional instrumentation. If the coils do not completely fill the aneurysm, residual blood can enter the neck and cause the aneurysm to refill. Meticulous delivery of coils to avoid catheter tip prolapse and deployment of new coils within a stable coil basket may further minimize the risk for coil displacement [39]. Derdeyn et al. [90], found that aneurysm size and coil protrusion were the most important variables associated with postprocedure ischemic events. Systemic heparinization during coil placements may help reduce the risk of thromboembolism; however, definitive treatment is removal of the protruded or migrated coil [89]. Significant coil displacement may necessitate prompt intervention to avoid significant neurological morbidity and mortality [86]. Successful endovascular strategies for retrieval of migrated coils include utilization of wire techniques, snares, retriever devices, and stent retrievers. Microsnares are usually best used during coil retrieval in vessels over 3 mm in diameter, with some risk of vessel dissection or perforation [88, 89]. Among established approaches to coil recovery is the so-called coil stretching with gentle retraction; however, this is only helpful when a coil is not entangled with another device [91]. The L5 Merci Retriever was designed as a device for thrombectomy in the intracranial circulation. However, this particular retriever also carries an indication for foreign body recovery based on trials with earlier models [91, 92]. Intrinsic to the design of the L5 Merci Retriever device is a nontapering helical coil with distally attached arcading suture filaments to ensnare loose particles [91]. These modifications may offer another possible approach for recovery of misplaced coils or stents. Occasionally, endovascular approaches fail and salvage approaches such as microsurgical removal and stent fixation of fractured coil fragments may be employed [86, 93, 94].

Cardiovascular procedures. Indwelling objects, including catheters, wires, and stents may embolize to the heart or the pulmonary artery when utilized in the venous system. Inadequate adhesion to the vessel wall, with subsequent stent dislodgment may be one factor for migration [55]. Within the venous circulation, migrating objects may come to rest at different anatomic levels depending on the location of placement and object size [55, 95]. For venous stents, meticulous procedural planning and selection of the correct device size are both critical. To avoid migration, stent diameter should be optimized to the size and location of the target vein [96, 97]. Stents that migrate from the lower extremities primarily lodge in the right side of the heart and the inferior vena cava, with the superior vena cava and the hepatic veins involved less commonly [98]. In terms of cardiac locations, migrating stents lodge between the inflow area of the right atrium and the inferior atrial or ventricular wall followed by the pulmonary arterial system [99].

Arterial stents may also undergo distal migration [100]. Prevention of such occurrences involves careful procedural planning, including detailed anatomic review of target vessel size and tortuosity [101]. Due to substantial risk of distal complications in such cases, immediate recognition and correction is indicated [102]. Various intravascular and open techniques have been described and successfully utilized to retrieve migrated arterial stents [100, 102, 103]. Operative removal of migrated intravascular stents is associated with high morbidity [104]. For that reason, percutaneous transluminal retrieval must be considered a primary option for the removal of a migrated stent. Exact technique and technical approach depends on stent length and diameter, area of migration, retrieval instruments available, operator experience, and anatomy of the vasculature.

Abdominal procedures. Endovascular interventions have been utilized in a variety of abdominal disease states, from chronic mesenteric ischemia to management of aneurysmal disease [105106]. Stent placement for mesenteric ischemia, much like in peripheral vascular disease, can be complicated by distal device migration [107]. Technical considerations are generally similar to those in peripheral vascular disease. Various abdominal aneurysms and pseudoaneurysms have been treated with endovascular embolization, stent insertion, and particle injection [105, 108]. Distal migration of aortic stents, as well as the presence of endoleaks, mandates the use of corrective endovascular techniques [108, 109]. Metallic coils, gelfoam, hydrogel particles, or acrylic glue may be used for embolization [110]. Vascular pseudoaneurysms or aneurysms with a narrow neck benefit greatly from coil embolization and wide-neck, large diameter structures are best treated with a stent [111].

More selective visceral artery embolizations may be also associated with INCOM and significant postprocedural complications. Udd et al. [112] reported a morbidity rate of 17% in a series of embolizations for bleeding pseudoaneurysms due to chronic pancreatitis. In that study, endovascular complications included one localized coil migration requiring procedural retrieval and one distal coil embolization to the iliac artery necessitating operative intervention [112].

Unintended therapeutic particle embolization. Injectable particles used to embolize tumors or to achieve hemostasis in cases of traumatic hemorrhage can unintentionally embolize outside of the intended target area and cause remote end-organ injury [113, 114]. In one case, a stainless steel coil originally placed in the left renal artery migrated into the distal left common femoral artery [113]. In another study, bile duct necrosis occurred at high rates following transcatheter hepatic arterial embolization using Gelfoam powder potentially due to an unintended particle dispersion pattern [115]. Particle INCOM has also been described following intracranial tumor embolization procedures, although the mechanism behind this phenomenon is not fully understood [114]. Finally, Mehta et al. [116], discuss the potential risk of hydrophilic polymer emboli introduced into the vasculature during interventional procedures (e.g., cardiac catheterization, diagnostic, and therapeutic angiography). Associated clinical sequelae may include pulmonary infarct, stroke, and distal hypoperfusion reported days to weeks following suspected INCOM events [116]. In addition to listing cases of intravascular embolization and/or migration of various iatrogenic objects, Table 5 also includes a number of instances where intravascular devices have migrated and eroded out of the vascular tree.

Complications of particulate foreign body embolization with cerebral angiography have also been described since the 1960s [117]. Shannon et al. [117], reviewed 5 years of autopsies related to postangiogram complications, looking at histological specimens from surgically resected cerebral arteriovenous malformations (AVMs). The results revealed three patients with cerebrovascular events likely related to particulate cotton fiber, gelfoam or polyvinyl alcohol embolization during diagnostic and therapeutic angiography. Possible theories include that the cotton fibers from guazepads, sponges, surgical drapes, etc. carry loosely woven synthetic fibers. These fibers may also be attracted to the glue utilized in AVM repair and travel with the liquid adhesive during the procedure. AVM embolization is typically a much longer procedure than conventional angiography alone, and this greater duration of “at risk” time may help facilitate catheter or guidewire contamination from these extraneous particles. Another comorbid factor includes difficult vascular access due to proximal atherosclerosis in affected patients, as noted during the procedure and by pathology sampling [117].

Advertisement

6. IVC filter migration and embolization

Although relatively rare, intravascular IVC filter migration and filter fragment embolization have been described [145]. Tam et al. [146] reported that the incidence of filter device fracture was relatively high (7.2%) and involved 5.5% of recipients of the Bard Recovery Filter. This incidence rate has been corroborated by others [15]. Certain anatomic factors may lead to the formation of concentrated stress points and thus may cause predisposition for device failure. Specific risk factors include deployment in a tortuous vena cava, deployment over renal ostia, and placement adjacent to a vertebral osteophyte [15]. In descending order, the most common sites for filter fragment embolization were pulmonary arteries (31%), iliac/femoral veins (27%), and the right ventricle and renal vein (3.8% each) [146]. Factors that increase the risk of filter migration and embolization include the so-called “mega-IVC” (e.g., IVC diameter ≥28mm), filter malpositioning, and a large embolus creating a “sail effect” that then dislodges the filter from the IVC, with subsequent embolization to the heart [147149]. A fracture-free survival model described by Tam et al., predicted a fracture rate of 40% at 5.5 years [146]. In one case, a broken IVC filter strut embolized to the heart, causing cardiac tamponade with hemodynamic collapse approximately 6 years after original placement procedure [149].

Advertisement

7. Conclusions

Foreign body embolism is a relatively heterogeneous grouping of rare but well-known complications. In aggregate, a vast majority of these events are iatrogenic in nature and involve retained catheters, wires, and various types of intravascular particles. Traumatic projectile fragments are well documented but far less common. Depending on the symptomatology, these unusual embolic events may go unnoticed for a period of time and may or may not require surgical intervention. The type and location of the emboli will dictate clinical approaches, with preference for endovascular retrieval with open surgical options reserved for the occasional case of unsuccessful minimally invasive intervention.

References

  1. 1. Duke, E., A.A. Peterson, and W.K. Erly, Migrating bullet: A case of a bullet embolism to the pulmonary artery with secondary pulmonary infarction after gunshot wound to the left globe. Journal of Emergencies, Trauma, and Shock, 2014. 7(1): pp. 38-40.
  2. 2. El Feghaly, M., et al., Endovascular retrieval of two migrated venous stents by means of balloon catheters. Journal of Vascular Surgery, 1998. 28(3): pp. 541-546.
  3. 3. Holley, C.T., et al., Retained catheter dilator in right ventricular outflow tract for 22 years. Journal of Cardiac Surgery, 2013. 28(6): pp. 679-681.
  4. 4. Carter, C.O., et al., Venous bullet embolism and subsequent endovascular retrieval—A case report and review of the literature. International Journal of Surgery Case Reports, 2012. 3(12): pp. 581-583.
  5. 5. Miller, K.R., et al., The evolving management of venous bullet emboli: a case series and literature review. Injury, 2011. 42(5): pp. 441-446.
  6. 6. Koirala, B., et al., Migration of a piece of shrapnel: femoral vein to superior vena cava—azygous junction. European Journal of Cardio-thoracic Surgery, 2012. 42(3): pp. 584-586.
  7. 7. Sandler, G., et al., Abdominal shotgun wound with pellet embolization leading to bilateral lower limb amputation: case report and review of the literature of missile emboli over the past 10 years. Journal of Trauma and Acute Care Surgery, 2009. 67(6): pp. E202-208.
  8. 8. Cheddie, S. and B. Sing, Guidewire embolism during central venous catheterization: Options in management. The Internet Journal of Surgery, 2013. 30: p. 1.
  9. 9. Chow, L.M., et al., Peripherally inserted central catheter (PICC) fracture and embolization in the pediatric population. The Journal of Pediatrics, 2003. 142(2): pp. 141-144.
  10. 10. Moffatt-Bruce, S.D., et al., Intravascular retained surgical items: a multicenter study of risk factors. Journal of Surgical Research, 2012. 178(1): pp. 519-523.
  11. 11. Berder, V., et al., Retrieval of a lost coronary stent from the descending aorta using a PTCA balloon and biopsy forceps. Catheterization and Cardiovascular Diagnosis, 1993. 28(4): pp. 351-353.
  12. 12. Abad, J., et al., Bronchial migration of pulmonary arterial coil. Cardiovascular and Interventional Radiology, 1990. 13(6): pp. 345-346.
  13. 13. Rosch, J., F.S. Keller, and C.T. Dotter, Materials and methods for transcatheter vascular occlusion: Some personal, practical views. Therapeutic Angiography, 1980, 3(4): pp. 242-243.
  14. 14. Bach, J.A., et al., Superior vena cava filter. In: Endovascular Interventions. 2014, New York, NY. pp. 1003-1011.
  15. 15. Cipolla, J., et al., Complications of vena cava filters: a comprehensive clinical review. OPUS 12 Scientist, 2008. 2(2): pp. 11-24.
  16. 16. Stawicki, S.P., et al., Vena cava filters: a synopsis of complications and related topics. The Journal of Vascular Access, 2008. 9(2): pp. 102-110.
  17. 17. Springer, J., W. Newman, and R. McGoey, Intravascular bullet embolism to the right atrium. Journal of Forensic Sciences, 2011. 56: S259–S262.
  18. 18. Stallings, L.A., et al., Right ventricular bullet embolism: Diagnostic and therapeutic decisions. Injury Extra, 2013. 44(7): pp. 64-66.
  19. 19. Andrews, C.M., et al., Venous fragment embolism to the pulmonary artery: A rare occurrence-case report and literature review of venous fragment embolization to the pulmonary artery. Military Medicine Radiology Corner. 2009. 174. pp. 1-8.
  20. 20. Manganas, C., et al., Traumatic pulmonary arteriovenous malformation presenting with massive hemoptysis 30 years after penetrating chest injury. The Annals of Thoracic Surgery, 2003. 76(3): pp. 942-944.
  21. 21. Khalifeh, M., et al., Penetrating missile embolisation. European Journal of Vascular Surgery, 1993. 7(4): pp. 467-469.
  22. 22. Lu, K., et al., Approach to management of intravascular missile emboli: Review of the literature and case report. Western Journal of Emergency Medicine, 2015. 16(4): p. 489.
  23. 23. Fernandez-Ranvier, G.G., et al., Pulmonary artery bullet embolism—Case report and review. International Journal of Surgery Case Reports, 2013. 4(5): pp. 521-523.
  24. 24. Pan, G.Z., et al., Bullet embolization from an aorto-caval fistula to the heart. Interactive Cardiovascular and Thoracic Surgery, 2013. 16(5): pp. 710-711.
  25. 25. Hartzler, G., Percutaneous transvenous removal of a bullet embolus to the right ventricle. The Journal of Thoracic and Cardiovascular Surgery, 1980. 80(1): p. 153.
  26. 26. Yamanari, M.G., et al., Bullet embolism of pulmonary artery: A case report. Radiologia Brasileira, 2014. 47(2): pp. 128-130.
  27. 27. Schroeder, M.E., et al., Retrograde migration and endovascular retrieval of a venous bullet embolus. Journal of Vascular Surgery, 2011. 53(4): pp. 1113-1115.
  28. 28. Padula, R.T., S.C. Sandler, and R. Camishion, Delayed bullet embolization to the heart following abdominal gunshot wound. Annals of Surgery, 1969. 169(4): p. 599.
  29. 29. Kortbeek, J.B., J.A. Clark, and R.C. Carraway, Conservative management of a pulmonary artery bullet embolism: case report and review of the literature. Journal of Trauma and Acute Care Surgery, 1992. 33(6): pp. 906-908.
  30. 30. SHANNON, F.L., et al., Venous bullet embolism: rationale for mandatory extraction. Journal of Trauma and Acute Care Surgery, 1987. 27(10): pp. 1118-1122.
  31. 31. Dato, G.M.A., et al., Posttraumatic and iatrogenic foreign bodies in the heart: report of fourteen cases and review of the literature. The Journal of Thoracic and Cardiovascular Surgery, 2003. 126(2): pp. 408-414.
  32. 32. Huang, J., et al., Popliteal artery embolism of bullet after abdominal gunshot wound. Radiology Case Reports, 2016. 11(4): pp. 282-286.
  33. 33. Nolan, T., et al. Bullet embolization: multidisciplinary approach by interventional radiology and surgery. In: Semin intervent Radiol 2012; 29(03): 192-196. New York, NY: Thieme Medical Publishers.
  34. 34. Yordanov, Y., D. Pateron, and A. May, An unusual aetiology of abdominal pain: the forgotten bullet. BMJ Case Reports, 2014. 2014: p. bcr2014208268.
  35. 35. Evans, D., et al., Complications associated with pulmonary artery catheters: a comprehensive clinical review. Scandinavian Journal of Surgery, 2009. 98(4): pp. 199-208.
  36. 36. Kornbau, C., et al., Central line complications. International Journal of Critical Illness and Injury Science, 2015. 5(3): p. 170.
  37. 37. Damascelli, B., et al., Placement of long-term central venous catheters in outpatients: study of 134 patients over 24,596 catheter days. American Journal of Roentgenology, 1997. 168(5): pp. 1235-1239.
  38. 38. Kock, H.-J., et al., Implantable vascular access systems: experience in 1500 patients with totally implanted central venous port systems. World Journal of Surgery, 1998. 22(1): pp. 12-16.
  39. 39. Chuang, M.-T., et al., Concurrent use of pigtail and loop snare catheters for percutaneous retrieval of dislodged central venous port catheter. The Kaohsiung Journal of Medical Sciences, 2011. 27(11): pp. 514-519.
  40. 40. Cheng, C.-C., et al., Percutaneous retrieval of dislodged totally implantable central venous access system in 92 cases: experience in a single hospital. European Journal of Radiology, 2009. 69(2): pp. 346-350.
  41. 41. Charvat, J., et al., Implantation of central venous ports with catheter insertion via the right internal jugular vein in oncology patients—single center experience. Supportive Care in Cancer, 2006. 14(11): pp. 1162-1165.
  42. 42. Turner, D.D. and S.C. Sommers, Accidental passage of a polyethylene catheter from cubital vein to right atrium: report of a fatal case. New England Journal of Medicine, 1954. 251(18): pp. 744-745.
  43. 43. Bernhardt, L.C., J.T. Mendenhall, and G.P. Wegner, Intravenous catheter embolization to the pulmonary artery. Chest Journal, 1970. 57(4): pp. 329-332.
  44. 44. Fisher, R.G. and R. Ferreyro, Evaluation of current techniques for nonsurgical removal of intravascular iatrogenic foreign bodies. American Journal of Roentgenology, 1978. 130(3): pp. 541-548.
  45. 45. Surov, A., et al., Intravascular embolization of venous catheter—causes, clinical signs, and management: a systematic review. Journal of Parenteral and Enteral Nutrition, 2009. 33(6): pp. 677-685.
  46. 46. Lafreniere, R., Indwelling subclavian catheters and a visit with the “pinched‐off sign”. Journal of Surgical Oncology, 1991. 47(4): pp. 261-264.
  47. 47. Ballarini, C., et al., Complications of subcutaneous infusion port in the general oncology population. Oncology, 1999. 56(2): pp. 97-102.
  48. 48. Lam, A.W.-C., et al., Disconnection of a venous Port-A-Cath followed by embolization after saline flush: rare case report. Japanese Journal of Clinical Oncology, 1999. 29(12): pp. 643-645.
  49. 49. Denny, M.A. and L.R. Frank, Ventricular tachycardia secondary to Port-a-Cath® fracture and embolization. The Journal of Emergency Medicine, 2003. 24(1): pp. 29-34.
  50. 50. Biswas, S. and P. McNerney, Ventricular tachycardia from a central line fracture fragment embolus: a rare complication of a commonly used procedure—a case report and review of the relevant literature. Case Reports in Critical Care, 2015. 2015:265326.
  51. 51. Thanigaraj, S., A. Panneerselvam, and J. Yanos, Retrieval of an IV catheter fragment from the pulmonary artery 11 years after embolization. Chest, 2000. 117(4): pp. 1209-1211.
  52. 52. Reynen, K., 14-year follow-up of central embolization by a guide wire. New England Journal of Medicine, 1993. 329(13): pp. 970-971.
  53. 53. THOMAS, J., et al., Nonsurgical retrieval of a broken segment of steel spring guide from the right atrium and inferior vena cava. Circulation, 1964. 30(1): pp. 106-108.
  54. 54. Bindraban, N.R., et al., Lasso technique for retrieving a broken, dislocated port-a-cath fragment. Netherlands Heart Journal, 2009. 17(2): pp. 75-6.
  55. 55. Nakabayashi, K., et al., Successful retrieval of a dismembered central venous catheter stuck to the right pulmonary artery using a stepwise approach. Case Reports in Cardiology, 2016. 2016:6294263.
  56. 56. Kim, O.K., et al., Transluminal removal of a fractured and embolized indwelling central venous catheter in the pulmonary artery. The Korean Journal of Internal Medicine, 2006. 21(3): pp. 187-190.
  57. 57. Pande, A., et al., Retrieval of embolized intracardiac peripherally inserted central catheter line: novel percutaneous technique by utilizing a flexible biopsy forceps. Heart Views, 2015. 16(4): p. 154.
  58. 58. Kalińczuk, Ł., et al., Percutaneous retrieval of centrally embolized fragments of central venous access devices or knotted Swan-Ganz catheters. Clinical report of 14 retrievals with detailed angiographic analysis and review of procedural aspects. Advances in Interventional Cardiology, 2016. 12(2): p. 44.
  59. 59. Choksy, P., S.S. Zaidi, and D. Kapoor, Removal of intracardiac fractured port-A catheter utilizing an existing forearm peripheral intravenous access site in the cath lab. Journal of Invasive Cardiology, 2014. 26(2): pp. 75-76.
  60. 60. Seldinger, S.I., Catheter replacement of the needle in percutaneous arteriography: a new technique. Acta Radiologica, 1953. 39(5): pp. 368-376.
  61. 61. Mao, M., et al., Complications of chest tubes: a focused clinical synopsis. Current Opinion in Pulmonary Medicine, 2015. 21(4): pp. 376-386.
  62. 62. Kwiatt, M., et al., Thoracostomy tubes: A comprehensive review of complications and related topics. International Journal of Critical Illness and Injury Science, 2014. 4(2): pp. 143-155.
  63. 63. Schrag, S.P., et al., Complications related to percutaneous endoscopic gastrostomy (PEG) tubes. A comprehensive clinical review. Journal of Gastrointestinal Liver Diseases, 2007. 16(4): pp. 407-418.
  64. 64. Stewart, J.R. and V.L. Gott, The use of a Seldinger wire technique for pericardiocentesis following cardiac surgery. The Annals of Thoracic Surgery, 1983. 35(4): pp. 467-468.
  65. 65. Luboz, V., et al., ImaGiNe Seldinger: first simulator for Seldinger technique and angiography training. Computer Methods and Programs in Biomedicine, 2013. 111(2): pp. 419-434.
  66. 66. Boyer, L., et al., Study of the supra-aortic trunks using the humeral Seldinger technique and digitalized angiography of the aortic arch. Apropos of 175 cases. Journal of Radiology, 1991. 72(10): pp. 497-502.
  67. 67. Macnab, A.J. and M. Macnab, Teaching pediatric procedures: the Vancouver model for instructing Seldinger's technique of central venous access via the femoral vein. Pediatrics, 1999. 103(1): pp. e8-8.
  68. 68. CliniSnips. Central line placement 2008 January 15, 2017]; Available from: https:// www.youtube.com/watch?v=Lb1Z3bndmA8.
  69. 69. Mubarak, G.S. Subclavian central venous catheterization: Theory & practice. 2013 January 15, 2017]; Available from: https://www.youtube.com/watch?v=RDtgzNWmYBw.
  70. 70. McGee, D.C. and M.K. Gould, Preventing complications of central venous catheterization. New England Journal of Medicine, 2003. 348(12): pp. 1123-1133.
  71. 71. Eisen, L.A., et al., Mechanical complications of central venous catheters. Journal of Intensive Care Medicine, 2006. 21(1): pp. 40-46.
  72. 72. O’Grady, N. P., et al., Guidelines for the prevention of intravascular catheter-related infections, 2011. Available online at: https://www.cdc.gov/hicpac/pdf/guidelines/bsi-guidelines-2011.pdf Last accessed on March 29, 2017.
  73. 73. Kusminsky, R.E., Complications of central venous catheterization. Journal of the American College of Surgeons, 2007. 204(4): pp. 681-696.
  74. 74. Ghatak, T., et al., Accidental guide-wire loss during central venous catheterization: A report of two life-threatening cases. Indian Journal of Critical Care Medicine, 2013. 17(1): p. 53.
  75. 75. Pokharel, K., et al., Missed central venous guide wires: A systematic analysis of published case reports. Critical Care Medicine, 2015. 43(8): pp. 1745-1756.
  76. 76. Nadaf, A., et al., Embolization of lost guide wire: mishap or blunder? Medico-legal Update, 2015. 15(2):127-131.
  77. 77. Schummer, W., et al., Loss of the guide wire: mishap or blunder? British Journal of Anaesthesia, 2002. 88(1): pp. 144-146.
  78. 78. Narendra, H. and K. Baghavan, Guide-wire embolism during subclavian vein catheterization by Seldinger technique. Indian Journal of Critical Care Medicine, 2006. 10(4): p. 257.
  79. 79. Arrayhani, M., et al., Unrecognized migration of an entire guide wire during hemodialysis catheter placement. Saudi Journal of Kidney Diseases and Transplantation, 2012. 23(5): pp. 1059-1059.
  80. 80. Waite, S., et al., Interpretive error in radiology. American Journal of Roentgenology. 2017;208: 739-749.
  81. 81. Roye, G., et al., Management of catheter emboli. Southern Medical Journal, 1996. 89(7): pp. 714-717.
  82. 82. Guo, H., J.D. Lee, and M. Guo, Guidewire loss: mishap or blunder? Heart, 2006. 92(5): p. 602.
  83. 83. Cassie, C.D., M.S. Ginsberg, and D.M. Panicek, Unsuspected retained 60-cm intravenous guidewire. Clinical Imaging, 2006. 30(4): pp. 287-290.
  84. 84. Lamprecht, W., Clinical aspects of iatrogenic intracardial foreign bodies. Der Chirurg; Zeitschrift fur alle Gebiete der operativen Medizen, 1965. 36: pp. 182-183.
  85. 85. Standard, S.C., et al., Retrieval of a Guglielmi detachable coil after unraveling and fracture: case report and experimental results. Neurosurgery, 1994. 35(5): pp. 994-999.
  86. 86. Ding, D. and K.C. Liu, Management strategies for intraprocedural coil migration during endovascular treatment of intracranial aneurysms. Journal of Neurointerventional Surgery, 2014. 6(6): pp. 428-431.
  87. 87. WATANABE, A., et al., Retrieval of a migrated detachable coil. Neurologia Medico-Chirurgica, 1995. 35(4): pp. 247-250.
  88. 88. Henkes, H., et al., A new device for endovascular coil retrieval from intracranial vessels: alligator retrieval device. American Journal of Neuroradiology, 2006. 27(2): pp. 327-329.
  89. 89. Kung, D.K., et al., Treatment of endovascular coil and stent migration using the merci retriever: report of three cases. Case Reports in Medicine, 2012. 2012:242101.
  90. 90. Derdeyn, C.P., et al., Postprocedure ischemic events after treatment of intracranial aneurysms with Guglielmi detachable coils. Journal Neurosurgery, 2002. 96(5): pp. 837-843.
  91. 91. Vora, N., et al., Retrieval of a displaced detachable coil and intracranial stent with an L5 Merci Retriever during endovascular embolization of an intracranial aneurysm. Journal of Neuroimaging, 2008. 18(1): pp. 81-84.
  92. 92. Felten, R.P., et al., The Food and Drug Administration medical device review process: clearance of a clot retriever for use in ischemic stroke. Stroke, 2005. 36(2): pp. 404-406.
  93. 93. Rodriguez, G.J., A. Maud, and M.H. Qureshi, Complications in endovascular embolization of intracranial aneurysms: prevention and bailout techniques. In: Complications of Neuroendovascular Procedures and Bailout Techniques (Khatri R, Rodriguez GJ, Raymond J, and Qureshi AI, Eds), Cambridge University Press, Cambridge, UK, 2016: pp. 10-43.
  94. 94. Ding, D., R.M. Starke, and K.C. Liu, Microsurgical strategies following failed endovascular treatment with the pipeline embolization device: case of a giant posterior cerebral artery aneurysm. Journal of Cerebrovascular and Endovascular Neurosurgery, 2014. 16(1): pp. 26-31.
  95. 95. Kwak, H.-S., et al., Stents in common iliac vein obstruction with acute ipsilateral deep venous thrombosis: early and late results. Journal of Vascular and Interventional Radiology, 2005.16(6): http://www.sciencedirect.com/science/article/pii/S1051044307606861.
  96. 96. Raju, S., P. Tackett, and P. Neglen, Reinterventions for nonocclusive iliofemoral venous stent malfunctions. Journal of Vascular Surgery, 2009. 49(2): pp. 511-518.
  97. 97. Antonucci, F., et al., Placement of venous stents: clinical experience with a self-expanding prosthesis. Radiology, 1992. 183(2): pp. 493-497.
  98. 98. Zoarski, G.H., et al., Endovascular extraction of malpositioned fibered platinum microcoils from the aneurysm sac during endovascular therapy. American Journal of Neuroradiology, 1997. 18(4): pp. 691-695.
  99. 99. Prestigiacomo, C.J., K. Fidlow, and J. Pile-Spellman, Retrieval of a fractured Guglielmi detachable coil with use of the Goose Neck snare “twist” technique. Journal of Vascular and Interventional Radiology, 1999. 10(9): pp. 1243-1247.
  100. 100. Eeckhout, E., J.C. Stauffer, and J.J. Goy, Retrieval of a migrated coronary stent by means of an alligator forceps catheter. Catheterization and Cardiovascular Interventions, 1993. 30(2): pp. 166-168.
  101. 101. Byrne, J., et al., A novel flexible endovascular stent for use in small and tortuous vessels. Neuroradiology, 2000. 42(1): pp. 56-61.
  102. 102. Gill, K.S. and R.C. Fowler, Atherosclerotic renal arterial stenosis: clinical outcomes of stent placement for hypertension and renal failure. Radiology, 2003. 226(3): pp. 821-826.
  103. 103. Slonim, S.M., et al., Management of misplaced or migrated endovascular stents. Journal of Vascular and Interventional Radiology, 1999. 10(7): pp. 851-859.
  104. 104. Koseoglu, K., et al., Retrieval of intravascular foreign bodies with goose neck snare. European Journal of Radiology, 2004. 49(3): pp. 281-285.
  105. 105. Laganà, D., et al., Multimodal approach to endovascular treatment of visceral artery aneurysms and pseudoaneurysms. European Journal of Radiology, 2006. 59(1): pp. 104-111.
  106. 106. Kasirajan, K., et al., Chronic mesenteric ischemia: open surgery versus percutaneous angioplasty and stenting. Journal of Vascular Surgery, 2001. 33(1): pp. 63-71.
  107. 107. Cognet, F., et al., Chronic mesenteric ischemia: Imaging and percutaneous treatment 1. Radiographics, 2002. 22(4): pp. 863-879.
  108. 108. Lee, J.T., et al., Stent-graft migration following endovascular repair of aneurysms with large proximal necks: anatomical risk factors and long-term sequelae. Journal of Endovascular Therapy, 2002. 9(5): pp. 652-664.
  109. 109. Resch, T., et al., Distal migration of stent-grafts after endovascular repair of abdominal aortic aneurysms. Journal of Vascular and Interventional Radiology, 1999. 10(3): pp. 257-264.
  110. 110. Schütz, A., et al., Proximal stent fixation of fractured coils: technical note. Neuroradiology, 2005. 47(11): pp. 874-878.
  111. 111. Fiorella, D., et al., Monorail snare technique for the recovery of stretched platinum coils: technical case report. Neurosurgery, 2005. 57(1): p. E210.
  112. 112. Udd, M., et al., Treatment of bleeding pseudoaneurysms in patients with chronic pancreatitis. World Journal of Surgery, 2007. 31(3): pp. 504-510.
  113. 113. Tisnado, J., et al., Peripheral embolization of a stainless steel coil. American Journal of Roentgenology, 1979. 133(2): pp. 324-326.
  114. 114. Bendszus, M., et al., Neurologic complications after particle embolization of intracranial meningiomas. American Journal of Neuroradiology, 2005. 26(6): pp. 1413-1419.
  115. 115. Makuuchi, M., et al., Bile duct necrosis: complication of transcatheter hepatic arterial embolization. Radiology, 1985. 156(2): pp. 331-334.
  116. 116. Mehta, R.I., et al., Hydrophilic polymer emboli: an under-recognized iatrogenic cause of ischemia and infarct. Modern Pathology, 2010. 23(7): pp. 921-930.
  117. 117. Shannon, P., et al., Inadvertent foreign body embolization in diagnostic and therapeutic cerebral angiography. American Journal of Neuroradiology, 2006. 27(2): p. 278-282.
  118. 118. Raftopoulos, C., et al., Transvascular coil hooking procedure to retrieve an unraveled Guglielmi detachable coil: technical note. Neurosurgery, 2002. 50(4): pp. 912-915.
  119. 119. Henkes, H., et al., Endovascular coil occlusion of 1811 intracranial aneurysms: early angiographic and clinical results. Neurosurgery, 2004. 54(2): pp. 268-285.
  120. 120. O'Hare, A., P. Brennan, and J. Thornton, Retrieval of a migrated coil using an X6 MERCI device. Interventional Neuroradiology, 2009. 15(1): pp. 99.
  121. 121. Lee, C.-Y., Use of wire as a snare for endovascular retrieval of displaced or stretched coils: rescue from a technical complication. Neuroradiology, 2011. 53(1): pp. 31-35.
  122. 122. Leslie-Mazwi, T., et al., Stent retriever use for retrieval of displaced microcoils: a consecutive case series. American Journal of Neuroradiology, 2013. 34(10): pp. 1996-1999.
  123. 123. Nas, O., et al., Retrieval of a dislocated coil and stent-assisted coiling by Solitaire® stent during endovascular treatment of an intracranial aneurysm. Diagnostic and Interventional Imaging, 2016. 3(97): pp. 381-384.
  124. 124. Chomyn, J.J., et al., Percutaneous removal of a Gianturco coil from the pulmonary artery with use of flexible intravascular forceps. Journal of Vascular and Interventional Radiology, 1991. 2(1): pp. 105-106.
  125. 125. Sanchez, R.B., et al., Wallstent misplaced during transjugular placement of an intrahepatic portosystemic shunt: retrieval with a loop snare. American Journal of Roentgenology, 1992. 159(1): pp. 129-130.
  126. 126. Kamalesh, M., K. Stokes, and A.J. Burger, Transesophageal echocardiography assisted retrieval of embolized inferior vena cava stent. Catheterization and Cardiovascular Diagnosis, 1994. 33(2): pp. 178-180.
  127. 127. Bartorelli, A.L., et al., Successful transcatheter management of Palmaz Stent embolization after superior vena cava stenting. Catheterization and Cardiovascular Diagnosis, 1995. 34(2): pp. 162-166.
  128. 128. Grosso, M., et al., Palmaz stent dislodgement into the left pulmonary artery complicating TIPS: percutaneous retrieval and extraction after venotomy. Cardiovascular and Interventional Radiology, 1995. 18(2): pp. 106-108.
  129. 129. Hoyer, M.H., et al., Transcatheter retrieval of an embolized Palmaz stent from the right ventricle of a child. Catheterization and Cardiovascular Diagnosis, 1996. 39(3): pp. 277-280.
  130. 130. Prahlow, J.A., T.J. O'Bryant, and J.J. Barnard, Cardiac perforation due to Wallstent embolization: a fatal complication of the transjugular intrahepatic portosystemic shunt procedure. Radiology, 1997. 205(1): pp. 170-172.
  131. 131. Marcy, P.-Y., N. Magné, and J.-N. Bruneton, Strecker stent migration to the pulmonary artery: long-term result of a “wait-and-see attitude”. European Radiology, 2001. 11(5): pp. 767-770.
  132. 132. ASHAR, R.M., E.A. HUETTL, and R. HALLIGAN, Percutaneous retrieval of a Wallstent from the pulmonary artery following stent migration from the iliac vein. Journal of Interventional Cardiology, 2002. 15(2): pp. 101-106.
  133. 133. Takahashi, T., et al., Migration of steel-wire coils into the stomach after transcatheter arterial embolization for a bleeding splenic artery pseudoaneurysm: report of a case. Surgery Today, 2001. 31(5): pp. 458-462.
  134. 134. Ozkan, O.S., et al., Guglielmi detachable coil erosion into the common bile duct after embolization of iatrogenic hepatic artery pseudoaneurysm. Journal of Vascular and Interventional Radiology, 2002. 13(9): pp. 935-938.
  135. 135. Turaga, K.K., et al., Cholangitis after coil embolization of an iatrogenic hepatic artery pseudoaneurysm: an unusual case report. Surgical Laparoscopy, Endoscopy & Percutaneous Techniques, 2006. 16(1): pp. 36-38.
  136. 136. Dinter, D.J., et al., Fatal coil migration into the stomach 10 years after endovascular celiac aneurysm repair. Journal of Vascular and Interventional Radiology, 2007. 18(1): pp. 117-120.
  137. 137. Reed, A., R. Suri, and R. Marcovich, Passage of embolization coil through urinary collecting system one year after embolization. Urology, 2007. 70(6): pp. 1222. e17-1222. e18.
  138. 138. Shah, N.A., et al., Embolization coils migrating and being passed per rectum after embolization of a splenic artery pseudoaneurysm,“the migrating coil”: a case report. Cardiovascular and Interventional Radiology, 2007. 30(6): pp. 1259-1262.
  139. 139. Jurałowicz, P., et al., Coil migration following intravascular embolization of hepatic artery aneurysm as a cause of life-threatening obstructive jaundice-case report. Polish Journal of Surgery, 2010. 82(12): pp. 684-686.
  140. 140. Cishek, M.B., L. Laslett, and G. Gershony, Balloon catheter retrieval of dislodged coronary artery stents: a novel technique. Catheterization and Cardiovascular Diagnosis, 1995. 34(4): pp. 350-352.
  141. 141. Kiyosue, H., et al., Dispersion of coils after parent-artery occlusion of radiation-induced internal carotid artery pseudoaneurysm. American Journal of Neuroradiology, 2004. 25(6): p. 1080-1082.
  142. 142. Chow, M., et al., Extrusion of a coil from the internal carotid artery through the middle ear. Hong Kong Medical Journal = Xianggang yi xue za zhi/Hong Kong Academy of Medicine, 2004. 10(3): p. 215.
  143. 143. Dagain, A., et al., Endovascular coil transfixing a cranial nerve five years after embolisation. Acta Neurochirurgica, 2008. 150(7): pp. 705-707.
  144. 144. Choi, D.H., et al., Nitinol clip distal migration and resultant popliteo-tibial artery occlusion complicating access closure by the StarClose SE vascular closure system. BMJ Case Reports, 2016. 2016: p. bcr2015012257.
  145. 145. Sarosiek, S., M. Crowther, and J.M. Sloan, Indications, complications, and management of inferior vena cava filters: the experience in 952 patients at an academic hospital with a level I trauma center. JAMA Internal Medicine, 2013. 173(7): pp. 513-517.
  146. 146. Tam, M.D., et al., Fracture and distant migration of the Bard Recovery filter: a retrospective review of 363 implantations for potentially life-threatening complications. Journal of Vascular and Interventional Radiology, 2012. 23(2):pp. 199-205. e1.
  147. 147. Owens, C.A., et al., Intracardiac migration of inferior vena cava filters: review of published data. Chest, 2009. 136(3): pp. 877-887.
  148. 148. Rao, B., et al., Inferior vena cava filter-associated abnormalities: MDCT findings. AJR American Journal of Roentgenology, 2012. 198(6): pp. W605-610.
  149. 149. Rogers, N.A., et al., Fracture and embolization of an inferior vena cava filter strut leading to cardiac tamponade. Circulation, 2009. 119(18): pp. 2535-2536.
  150. 150. Taslimi R, Safari S, Kazemeini A, Aminian A, Joneidi E, Larti F. Abdominal pain due to a lost guidewire: a case report. Cases Journal. 2009;2:6680.
  151. 151. Oh J, Kim J, Hong S, Hu C, Pyen J, Whang K, et al. Retrieval of unintended migrated detached coil: case report. The Journal of Cerebrovascular and Endovascular Neurosurgery. 2014 Sep;16(3):268-274.

Written By

Thomas R. Wojda, Stephen D. Dingley, Samantha Wolfe, W. T. Hillman Terzian, Peter G. Thomas, Daniel Vazquez, Joan Sweeney and Stanislaw P. Stawicki

Submitted: 14 February 2017 Reviewed: 21 February 2017 Published: 21 June 2017