1. Introduction

Flow boiling has an extremely high heat transfer coefficient, and is applied in variety of practices. However, once the heat flux exceeds a certain high level the heated surface can no longer support continuous liquid contact, associated with substantial reduction in the heat transfer efficiency. It may result in a sudden rise of surface temperature in a heat flux controlled system, or a drastic decrease in power transferred in a temperature controlled system. This phenomenon is called the boiling crisis, and the maximum heat flux just before the boiling crisis is usually referred to as critical heat flux (CHF).

Depending on the flow regimes, two types of CHF are classified: (i) in subcooled or low quality region the CHF is characterized by the transition from nucleate boiling to film boiling, and it is termed as the departure from nucleate boiling (DNB); (ii) in higher quality region the CHF is characterized by the dryout of liquid film of annular flow. The DNB and dryout have substantially different mechanisms, and are generally cataloged as the first and the second kind of critical heat flux, respectively (Tong and Tang, 1997).

The CHF is an important subject to many engineering applications. Especially, in a nuclear reactor the occurrence of critical heat flux could lead to a failure of fuel element, and thus the CHF is a major limit for the reactor safety. During past five decades the CHF has been investigated extensively over the world theoretically and experimentally (IAEA-TECDOC-1203, 2001). A great number of empirical correlations and physical models have been proposed. In recent years, a Look-Up Table method (LUT) is widely accepted due to its advantages of higher accuracy, wider range of application, correct asymptotic trend and convenience for updating (Groeneveld, et al., 1996). This table is applied in the system code RELAP5 for reactor safety analysis. The LUT contains a tabulation of normalized CHF data of a uniformly heated tube of 8 mm in diameter at discrete local parameters of pressure, mass flux and quality. Several correction factors are incorporated for utilization of the LUT in other conditions to account for the effects of diameter, bundle, spacer, flux distribution, flow orientation, etc.. Unfortunately, there exists a scarcity of CHF data in low pressure/low flow/ subcooled region, as shown in Fig.1. Because of the extreme complexity of the phenomenon and the lack of adequate knowledge of the mechanisms, all these predictive methods are heavily relied on experimental data, and can not be extrapolated out of their ranges with confidence.

In China Institute of Atomic Energy (CIAE), in the past four decades a great number of CHF experimental data of subcooled boiling of flowing water were obtained in tubes and annuli at lower pressure with different diameter or gap to support the designs of research reactors, HFR and CARR, which were first put into operation in 1980 and 2011, respectively. In recent years the experiments were extended to the region of near-critical pressure with lower flow for the R&D of Supercritical Water-Cooled Reactor (SCWR). In these experiments the CHF (DNB) phenomena are studied with emphases on lower pressure and higher pressure with lower flow. The characteristics and parametric trends of the CHF are clarified, and the physical models are derived.

Figure 1.

Range of database for 1996 CHF Look-up table (Groeneveld, et al., 1996)

Advertisement

2. Parametric trends

A comprehensive review on the subcooled flow boiling CHF was given by Berglest (1977). As concluded, the effect of heating length disappears when exceeding 200 mm and the subcooled boiling CHF depends only on local parameter (“local condition hypothesis”). The CHF increases with the local mass flux and subcooling increasing. The effect of pressure is more complicated: the CHF increases with pressure in low pressure region, is relatively constant over an intermediate range of pressure, and decreases in high pressure region. The effect of geometry on CHF is observed in many experiments, and is accounted by a factor f = (De/8)n, in which De is the hydraulic diameter in mm. Different value of the exponent n is obtained from different experiments, ranging from -0.1 to -0.5. For applying the LUT in reactor safety analysis code RELAP5 the value of n = -0.5 is used. While for annulus or rectangular channels the effect of gap width is not observed in many experiments.

In Savannah River lab and Columbia University the subcooled CHF experiments were conducted with D2O and H2O coolant and aluminum and stainless-steel heaters (Knoebel et al., 1973). It was concluded that the CHF for D2O is 16% greater than for H2O at constant subcooling and velocity, and the CHF of aluminum heaters is a minimum of 20% greater than for stainless steel.

Some typical subcooled boiling CHF correlations are listed in Tab.1. Similar trends of the CHF with the flow rate and subcooling are represented in various correlations, but the degrees of these effects are different significantly. The present investigation has revealed that these effects are inter-dependent, associated with complicated parametrical trends for different regions of conditions.

Table 1.

Subcooled flow boiling CHF correlations

Advertisement

3. Experiment

3.1. Technique

The onset of critical heat flux is characterized by a drastic increase in the wall temperature. For subcooled flow boiling of water with lower pressure the critical heat flux is higher and it could lead to a failure of the heated wall rapidly. This kind of CHF is also called as “fast burnout”. In experiment the onset of CHF is usually detected by thermocouples for protection of the test section. However, the occurrence of CHF generally initiates from a small area (or a spot), and for a test section of larger size the CHF spot can not be expected exactly. This presents a challenge for prevention of the test section from burnout. For this condition the photocell has advantage for the detection of CHF.

In the present experiments the pressure and flow rate are kept at constant, and the CHF is approached by increasing slowly the water temperature or the power to test section. When the CHF occurs and the wall temperature exceeds about 500°C, the photocell produces an output, which switches off the power supply to test section. This technique is used by author for all the experiments in tubes and annuli.

3.2. Experimental results

3.2.1. Higher pressure CHF (Chen et al., 2011)

Experiment was performed in an uniformly heated inconel tube of 7.95 mm in diameter and 0.8 m in heating length, covering the ranges of pressure of p= 1.96 – 20.4 MPa, mass flux of G= 476 – 1653 kg/m2s, inlet subcooling of ΔTs,i= 49 – 343 K, outlet subcooling ofΔTs,o= 1 – 145 K and critical heat flux of qC= 0.26 – 4.95 MW/m2.

For the present low flow condition the CHF is related to the inlet condition, characterizing the mechanism of total power dominant. Totally, 193 data are obtained, and are formulated as the following empiric correlation,

qC=cqsE1

where qs is the heat flux for the exit to reach the saturation temperature, evaluated by

qs=(HsHi)GD4LE2

and

c=Min[2350(10.0307p)(G(HsHi))0.35,1.0]E3

where p is the pressure, Hiand Hs the inlet enthalpy and saturation enthalpy, respectively, Gthe mass flux, Dthe diameter and L the heating length. Fig.2 shows the comparison of the prediction of Eq.(1) with the experimental data by plotting the ratio of qCHF,c/qCHF,M versus P or G. The average deviation, AVG, is 0.75% and the standard deviation, RMS, is 5.34%.

Figure 2.

Comparison of experimental data of higher pressure with the prediction by Eq.(1)

The effects of mass flux, inlet subcooling and pressure are exemplified in Fig.3 and 4. The CHF decreases substantially with mass flux decreasing. As can be seen, at G > 1200 kg/m2s the data are close to the prediction of 96-CHF Look-Up Table (LUT), but at low mass flux the data are overpredicted significantly (Fig.3). For lower pressure the effects of inlet subcooling and mass flux are stronger than higher pressure, associated with complicated trend of the CHF with pressure. For G > 1200 kg/m2s higher CHF corresponds to lower pressure, especially in high subcooling region (Fig.4(a)). For G= 700 – 1200 kg/m2s the results of p< 16 MPa are not different appreciably for different pressures. For G< 600 kg/m2s, in high subcooling region lower CHF corresponds to higher pressure, while in low subcooling region lower CHF is attained at lower pressure (Fig.4 (b))

Figure 3.

Effect of mass flux on the CHF

Figure 4.

Variations of CHF with inlet subcooling for different mass fluxes and pressures

3.2.2. Lower pressure CHF

3.2.2.1. CHF in tubes

Medium and high subcooling (Chen et al., 2000)

Experimental data were obtained in uniformly heated stainless-steel tubes of 5.17, 8.05, 10.0 and 16.0 mm in diameter, covering the ranges of pressure p = 0.13 – 1.92 MPa, velocity V = 1.47 – 22.32 m/s, as listed in Tab.2.

Fig.5 and 6 exemplify the variations of critical heat flux with local velocity and subcooling for different pressures. The CHF increases strongly with the velocity increasing (Fig.5). For subcooling higher than about 30 K, the CHF exhibits an approximately linear increase with increase of subcooling. In medium subcooling region the CHF is not different greatly between different pressures. For p < 0.3 MPa the trend of CHF with subcooling is steeper than that of higher pressure, so that in low subcooling region lower CHF is obtained at lower pressure (Fig.6). The CHF also exhibits a general increase trend with the decrease of diameter, and at lower velocity this effect appears stronger than higher velocity.

No.Diameter
D (mm)
Length
L (mm)
Pressure
P (MPa)
Velocity
V (m/s)
Subcooling
△Ts (K)
Number of data
15.172550.13-1.783.26-22.326.2-89.662
28.05383, 3960.14-1.921.85-16.058.3 – 88.265
310.0295, 4000.15-1.663.39-9.2630.3-89.553
416.0295, 3900.19-1.291.47-13.736.7-108.756

Table 2.

The Experimental conditions for CHF in tubes

Figure 5.

Effect of velocity on the CHF

Figure 6.

Effect of subcooling on the CHF

224 CHF data of subcooling higher than 35 K are formulated by the following empiric correlation with local parameters of p, V, △Ts and D:

qCHF=0.109×106×(1+0.104V)×(15P+ΔTs10.1p)×(D/8.0)0.350.05/lnVE4

where the pressure P is in MPa, velocity V in m/s, subcoolingΔTsin K and diameter D in mm. Eq.(2) predicts the experimental data with AVG of 0.83% and RMS of 7.2%, as shown in Fig.7.

Figure 7.

Comparison of experimental data of p<1.9 MPa in tubes with the prediction by Eq.(2)

Low subcooling (Chen et al., 2005).

The experiment was performed in a stainless-steel tube of D=15.9 mm with emphasis on the CHF characteristic in low subcooling region. The conditions cover the ranges of pressure of 0.2 - 1.7 MPa and velocity of 2.2 - 13.2 m/s. Fig.8 exemplifies the variations of CHF with subcooling. For p > 1.0 MPa, the CHF decreases with △Ts decreasing monotonously. For p < 0.3 MPa, however, this trend breaks at a certain low value of subcooling, and it turns to increase at further low subcooling. The subcooling at the minimum CHF varies from 13 to 30 K with lower value corresponding to lower velocity.

Figure 8.

The variation of CHF with subcooling for different pressures

This behavior was also observed in the author’s experiment in annuli and other similar experiments (Zeigarnik, 1994, Knoeble et al., 1973). It can be attributed to the onset of net vapor generation (NVG) or the onset of significant voiding (OSV). For p < 0.3 MPa, the vapor density is very small, so that in NVG regime the volumetric flow rate increases essentially, associated with a considerable increase in the liquid velocity. Therefore, the bubbles generated on the heated surface are more likely to enter into the liquid core, resulting in higher CHF. At high pressure the vapor density is much higher, and hence the CHF behavior could not vary distinctly in low subcooling region.

The NVG or OSV was generally identified by a sharper increase in the pressure drop. The following type of empiric correlation was derived

q''=ηΔTsVnE5

with the values of n ranging from 0.5 to 1.0. (Siman-Tov, et al. 1995). For the present experimental condition most correlations predict the OSV at subcooling of below 40 K.

Fig.9 shows the variations of pressure drop with the increase of exit temperature. As seen, before the OSV the pressure drop increases slowly with the temperature increasing. After the OSV this trend varies distinctly. Especially at low pressure it is much steeper than that at higher pressure.

In a reactor core the fuel elements are located in parallel channels. Therefore, at low pressure with low subcooling the OSV could result in flow instability or flow excursion (FE), characterized by a continuous decrease of flow rate in a channel. This could eventually lead to a failure of fuel element. Therefore, for reactor safety the limit of OSV is taken as a cr1terion in combination with the limit of minimum ratio of DNB

3.2.2.2. CHF in annuli

Single-side heating (Chen et al., 2004)

Experiments were performed in 8 annuli made of stainless-steel tubes with single-side heating. The diameter of outer wall is 16, 32 or 70mm and gap width is 2 to 4mm. Great majority of CHF data were obtained at outer wall and less at inner wall, covering the range of pressure of 0.17 - 1.8MPa, mass flux of 1300 to 18200 kg/m2s, outlet subcooling of 27-105 K and critical heat flux of 2.0 - 18.1 MW/m2. The experimental conditions are listed in Tab.3.

Figure 9.

The variations of pressure drop with exit temperature for different pressures

NoDiameters
D2/D1 (mm)
Length L (mm)Pressure
P (MPa)
Mass flux
G (Mg/m2s)
subcooling
△Ts (K)
Number of data
116/12260-4000.17-1.312.8-18.234-8967*
232/283000.24-1.212.8-12.435-9846**+27*
332/27.63000.3-1.13.5-12.129-84230*
432/26.8275-4000.28-1.12.9-13.037-10267*
532/263000.36-0.853.6-12.737-7047*
632/243000.18-1.81.3-8.027-10561*
770/662550.25-0.42.9-7.026-5415*
870/652550.25-0.373.2-5.734-4918*

Table 3.

Experimental conditions for CHF in annuli with single-side heating

The velocity and subcooling have predominant effects on the CHF. Under most conditions of interest the effect of pressure is not appreciable. The variation of gap width from 2.0 to 4.0mm does not make an appreciable effect on the CHF. This can probably be explained as follows: larger gap size associates with lower heat transfer coefficient to the liquid core, as suggested by the turbulent convection heat transfer correlation, on the other hand larger gap size corresponds to higher Reynolds number, which is benefit for the departure of bubbles from heated surface. For the present conditions these two opposite factors would be comparative, making the CHF not sensitive to the gap size. These results are consistent with many similar experiments (see Tab.1).

In the present experiment the effect of curvature of heated surface is not observed. This is understandable, because the curvature of heated surface is small, compared to the bubble, and it could not have a noticeable effect on the bubble behavior.

For the sake of simplicity in engineering applications, the effects of pressure, diameter and gap width are ignored, and the experimental data are formulated as the following empiric correlation

qc=1.21×106×V0.5(1+0.03ΔTS)E6

The comparison of calculation of Eq.(3) with the experimental data is shown in Fig.10. The AVG and RMS are -0.01 and 0.083, respectively.

Figure 10.

Comparison of the experimental data in annuli of single-side heating with the predictions of Eq.(3)

Bilateral-side heating (Chen, et al., 1996)

Experiment was performed in a stainless-steel annulus of D1=28 mm and D2=35.7 mm and heating length of 160 mm with bilateral-side heating. The critical heat flux data were obtained at the outer wall. The conditions cover the range of pressure of 0.31 – 0.39 MPa, velocity of 2.55 – 8.12 mm, subcooling of 49.1 – 76.6 K and the ratio of inner to outer-wall heat fluxes of q1/q2 of 0 – 0.94.

For convenience in comparison, the result of outer-side heating is formulated by

qc,0=0.96×106×V0.43×(1+0.057ΔTs,0)E7

as shown in Fig.11.

The experimental results of bilateral-side heating are displayed in Fig.12 by plotting the ratio of qc/qc,0 against q1/q2 (1 and 2 denote the inner-wall and outer-wall, respectively). As seen, the critical heat flux exhibits an increase trend with q1/q2 increasing. When q1/q2 closes to 1.0 the CHF is increased by 15 – 20%. It can be attributed to the variation of temperature profile in liquid core, which results in an increase in condensation efficiency of the bubbly layer by subcooled liquid core, that is similar with that in single-phase convection heat transfer. This effect can be clarified further by the model analysis latter in paragraph 4.3.

Figure 11.

The CHF results of outer-wall heating

Figure 12.

The ratio of qc/qc,0 versus q1/q2

3.2.3. Transient CHF (Chen et al., 2005)

Critical heat flux is more likely to occur under off-normal or accident conditions, in which a transient would experiences of flow rate, pressure and/or power. Many studies have focused on the transient CHF (Leung, 1978, Chang, et al., 1989, Iwamura, et al., 1987, 1994, Celata, et al., 1991, Weisman, 1993, Moon, et al., 2002). In higher quality region the experimental results revealed the inadequacy of the steady-state CHF correlation for transient conditions. While in subcooled and low quality region, the effect of transient on the CHF was found not appreciable. In general, the transient CHF has not been studied adequately for wider range of condition, and in evaluation of nuclear reactor safety the CHF for transient conditions is predicted with the correlations derived at steady-state conditions (IAEA-TECDOC-1203, 2001).

In the present study an experiment of flow-reduction transient CHF was performed in a stainless-steel tube of 15.9 mm in diameter, covering the range of pressure of 0.2 - 1.4 MPa, initial velocity of 4.5 - 13.5 m/s, and the initial inlet subcooling of 80 – 160 K. The flow rate was reduced linearly as

m=m0(1kt)E8

where m and m0 are the instantaneous and initial flow rate, respectively, t is the time, and k is the flow reduction rate, ranging from 0.0075 to 0.24 1/s.

The experimental results are shown in Fig.13, in which the P, V and △Ts are the instantaneous values. For P > 1.0 MPa the effect of flow transient on CHF appears not prominent. For P < 0.3 MPa, in high subcooling region the effect of transient is not appreciable, while for subcooling lower than about 50 K the result departs from the trend of steady-state distinctly, and higher CHF is attained at higher flow reduction rate.

Figure 13.

The experimental results under flow transient condition

Different effect on the CHF observed at different conditions can probably be explained by different mechanisms of the CHF. For low subcooling the CHF is induced by a limit of enthalpy of bubbly layer, while for high subcooling the CHF is induced by a limit of bubbly-layer condensation by the subcooled liquid core (Thorogerson et al., 1974). Compared to the steady-state, at a flow-reduction transient with constant heat flux and constant subcooling the enthalpy in the bubbly layer is higher and the temperature in the liquid core is lower. At high subcooling the thickness of bubbly layer is small, thus for a constant CHF the subcooling would not be different greatly from the steady-state. While at low subcooling the thickness of bubbly layer is larger, and a constant CHF would occur at a higher subcooling than that of steady-state. It would lead to the premature of the OSV, associated with prominent effect on the CHF, as observed at low pressure.

Fig 14 shows the variation of pressure drop before the onset of CHF in flow-reduction transients of p =0.23 MPa and k = 0.24 with heat flux of q = 890, 775 and 750 W/cm2 for run iii, iv and v respectively. In run iii, the pressure drop exhibits a monotonous decrease with flow rate decrease, until the onset of CHF. While in run iv and v, before the onset of CHF the decrease of pressure drop is followed by a sharp increase. In these three runs the CHF are higher than those of steady-state by about 5%, 18% and 36%. The critical subcoolings are 54.7, 46.5 and 37 K respectively, all of which are higher than the values of steady-state, evidencing the premature of OSV.

Figure 14.

Variation of pressure drop before the onset of CHF

Advertisement

4. Physical model

4.1. Mechanism

In subcooled flow boiling the enthalpy of bubbly layer is determined by the heat transfer from the interface of bubbly layer to the liquid core, and the excessive bubble crowding serves as a thermal shield, leading to the onset of CHF. For the DNB with low subcooling or saturated condition, the critical enthalpy models were proposed by Weisman and Pei (1983) and Tong (1968), in which the heat transfer coefficient from the interface of bubbly layer to liquid core was estimated by correlations derived from their experiments. For the DNB with high subcooling, the liquid sublayer dryout models were proposed by Katto (1992), Lee and Mudawar (1983) and Celata et al. (1994), in which the bubble diameter, the thickness of liquid sublayer and the length of vapor blanket were determinant for the sublayer dryout.

For higher subcooling the major part of heat from wall is transferred to the liquid core and a minor part for increase of the enthalpy of bubbly layer. Therefore, the characteristic of bubbly layer is primarily controlled by the heat transfer from the bubbly layer to liquid core. This heat transfer is closely relative to the turbulence near the edge of bubbly layer, and is sensitive to the distance from the wall. The increase in thickness of bubbly layer has positive effect on the CHF due to increase in the heat transfer efficiency to liquid core, but negative effect due to increase in the thermal resistance of the bubbly layer. The balance of these two factors gives a critical value of the thickness. Therefore, in the liquid sublayer dryout model the thickness of bubbly layer is a determinant factor.

4.2. Model for tube (Chen et al., 2011)

The model is based on the mechanism of liquid sublayer dryout by modifying the Celata’s model for the thickness of bubbly layer to cover both high and low subcooling region.

Bubbly layer

At high flow and high subcooling the minimum thickness of bubbly layer is determined by the size of a bubble, while at low subcooling it could be larger due to bubble crowding. For the present experimental condition the following expression on the thickness of bubbly layer is attempted,

δ=k1DB(1+k2ek3PrQ)E9

where the factork1,k2 and k3are the constants, Pr is the Prandtl number, Qis a parameter group (see Eq.(8)). DBis the bubble or vapor blanket equivalent diameter, evaluated by Staub correlation (1968), as

DB=32σf(β)ρlfG2E10

where σ is the surface tension, ρlthe liquid density, Gthe mass flux, f(β)is a function with parameter of contact angle and recommended as f(β)= 0.02-0.03. In the present model it is taken as

f(β)=0.03forp10MPaE11

and

f(β)=0.03(10.055(p10))forp>10MPaE12

where p is the pressure in MPa.

The friction factor,f , is calculated by Colebrook-White equation combined with Levy’s rough surface model (1967), as

1f=1.142.0log(εD+9.35Ref)E13

where D is the tube diameter, Re the Reynolds number, εis the surface roughness, accounted byε=0.75DB.

Liquid core

The velocity distribution in the liquid core is represented by Karman’s universal law, as in Celata’s model,

U+=y+for0y+<5E14
U+=5.0lny+3.05for5y+<30E15
U+=2.5lny++5.5fory+30E16

with

U+=UUτy+=yUτρlμlE17

and

Uτ=(τwρl)0.5E18

where Uis the liquid velocity, ythe distance from the wall, μlthe liquid viscosity and ρl the liquid density, Uτthe friction velocity, and τw is the wall shear stress, evaluated by

τw=fG28ρlE19

The temperature distribution in the liquid core is as follows (Martinelli, 1947),

T0T=QPry+for0y+<5E20
T0T=5Q{Pr+ln[1+Pr(y+51)]}for5y+<30E21
T0T=5Q[Pr+ln(1+5Pr)+0.5ln(y+30)]fory+30E22

with

Q=qρlCpLUτE23

Equations (5) to (7) are assumed valid in the region ofδyr, and the T0 is a referent value, which is determined byT=Ts aty=δ.

Calculation of critical heat flux

The local enthalpy,H , is calculated by

Hm=HC(mmB,gmB,l)+HgmB,g+HlmB,lE24

where m is the total flow rate, mB,gand mB,l are the vapor and liquid flow rate in the bubbly layer, respectively, Hgand Hl are the vapor and liquid enthalpy, and HC is the enthalpy of liquid core.

Them, mB,gand mB,lare evaluated by
m=πD24GE25
mB,g=π(Dδ)δαBρgUB¯E26

and

mB,L=π(Dδ)δ(1αB)ρlUB¯E27

where αB is the void fraction in the bubbly layer, and it is taken as αB= 0.9, UB¯is the average velocity of bubbly layer, estimated by

UB¯=0.5Uy=δE28
HCis calculated at the average temperature from the edge of bubbly layer to the center of tube,TC , which is calculated by
TC=δrTU(ry)dyδrU(ry)dyE29

where r is the radius of tube, and δis the distance from wall at which the temperature is equal to the saturation value.

The exit enthalpy,H , is evaluated from the heat balance equation, as

H=Hi+4qLGDE30

where Hiis the inlet enthalpy, and L the heating length.

Calculation is started with a test heat flux q (q<qs), and theδ,mB,g , mB,land TC are calculated by Eq. (4), (10), (11) and (12). Then, theHis calculated by Eq.(9) and compared to that calculated by Eq.(13). The result of CHF is obtained through an iterative process.

To get the calculations better fit to the experimental data, the constants in Eq. (4) are as: k1= 0.75, k2= 1000, and k3= 1.0. At low subcooling qC is close toqs, and not sensitive to theδ, thus the maximum value of δ is simply set as 0.1D.

The experimental data in tubes are calculated by the present model. The comparison is shown in Fig.15 and 16 for p > 2 MPa and < 2 MPa, respectively.

Figure 15.

Comparison of the calculations of present model with the experimental results in tube for p > 2 MPa

Figure 16.

Comparison of the calculations of present model with the experimental results in tubes for p < 2 MPa

4.3. Model for annulus (Chen et al., 1996)

Fig.17 shows schematically the profiles of velocity and temperature in the liquid core of an annulus. Some assumptions are made as follows:

  • Each wall is heated uniformly, and the flow and heat transfer conditions are fully developed;

  • At the edge of liquid bubbly layer the heat flux is equal to that of outer-wall

  • In liquid core the properties are evaluated at the bulk temperature.

Figure 17.

The profiles of velocity and temperature in the flow

In liquid core the energy balance equation is written as

utx=1rr[r(klρlCpl+1Prtεm)tr]E31

with

tx=t¯x=2(q1r1+q2r2)ρlCplu¯(r22r12)E32

For fully developed flow with uniform heating, the t/xis a constant. Integrating Eq.(14) gives

tr=1r(1+PrPrtεmνl)[2(q1r1+q2r2)kl(r22r12)u¯r1rurdrq1r1kl]E33

The average bulk temperature is approximated by

t¯=2u¯(r22r12)r1riturdrE34

Integrating Eq.(16) by parts gives

tit¯=2u(r22r12)t1tir1rturdrdtE35

where ti is the temperature at the outer edge of bubbly layer. For low pressure with higher subcooling the enthalpy of bubbly layer is negligible small.

By assuming tiequal to the saturation temperature, Eq.(17) is approximated as the subcooling △Ts. Introducing R=r/r2 andU=u/u¯, combining of Eq.(16) with Eq.(17) gives

ΔTs=21R12R1Ri1(1+PrPrtεmνl)R[2(q1r1+q2r2)kl(1R12)(R1RURdR)2q1r1klR1RURdR]dRE36

The velocity distribution is assumed in power law, as

uum=[rjrrjrm]1/5j=1forr1<r<rmj=2forrm<r<r2E37

where r1 and r2 are the radius of inner and outer wall, respectively, and rm is the radius of maximum velocityum, calculated from

τ*=τ2τ1=(1Rm2)R1Rm2R12E38

where τ1 andτ2are the shear stress at the inner and outer wall, respectively.

The friction factor is estimated by (Xu et al., 1979)

f=93(qhfgρgu¯)0.7(hfgρgCplρlTs)0.4(ρgρl)0.2f0E39

with

f0=0.3164Re0.25E40

The momentum eddy diffusivity is evaluated by (Levy, 1967)

εmνl=115|(r2rm)|u*νl(1η2)(1+2η2)E41

with

η=(rmr)/(rmr1)E42

and

u*=(τwρl)0.5E43

The turbulent Prandtl number, Prt, is taken as Prt=1/1.2.

Both the experimental data of 8 annuli with single-side heating and the annulus with bilateral-side heating are predicted by this model. The comparison is shown in Fig.18 to 20.

Figure 18.

Comparison of the prediction of present model with the experimental data of 8 annuli

Figure 19.

Comparison of the model prediction with experimental data of bilateral heating

Figure 20.

Effect of bilateral-side heating on the CHF by model prediction

Advertisement

5. Summary

Critical heat flux is an important subject to many applications. Especially for nuclear reactors, it is a major limit for the safety. The CHF has been investigated extensively over the world, and various prediction methods have been available. Unfortunately, there exists a scarcity of experimental data in certain regions. Because of extreme complexity of the phenomenon and the lack of adequate knowledge of the mechanisms, all these predictive methods are heavily relied on the experimental data, and can not be extrapolated out of the range with confidence.

In the present lab a great number of critical heat flux data of subcooled water have been obtained in tubes and annuli with different diameter and gap size over wide range of parameters with emphasis on lower pressure and higher pressure with low flow. The results fill the gap of database and the knowledge of the phenomenon.

The velocity and subcooling are the predominant parameters for the CHF. At lower pressure these effects are stronger. At the pressure below 0.3 MPa, when the subcooling decreases below a certain low value the CHF behavior varies substantially as a result of significant voiding. The effect of geometry is related to the pressure, subcooling and velocity. All these effects are inter-dependent, and are hardly to be represented in a single correlation for wide range of conditions. In the present study two models have been developed for the subcooled flow boiling CHF in circular tube and annulus, based on the mechanisms of CHF and the present experimental data. They will be validated and improved for extended range of conditions.

Nomenclature

A flow area

AH heated area

Cp specific heat

D diameter

△Ts subcooling

f friction factor

G mass flux

h heat transfer coefficient

hfg latent heat

H enthalpy

k thermal conductivity

L heating length

p pressure

q heat flux

r radius

T,t temperature

U u velocity in axial direction

V average liquid velocity at CHF

x quality

Nu Nusselt number

Pr Prandtl number

Prt turbulent Prandtl numbe

Re Reynolds number

W channel width

y distance from the wall

ρ density

σ surface tension

ε surface roughness

εm momentum eddy diffusivity

μ dynamic viscosity

ν kinematic viscosity

τw wall shear stress

αB void fraction

λ critical wavelength

Subscript

B bubble

c critical, calculatiom

l water

g steam

m maximum velocity

M measurement

s saturation

1 inner-wall

2 outer-wall

References

  1. 1. BerglestA. E.1977Burnout in Boiling Heat Transfer, Part II: Subcooled and Low-Quality Forced-Convection System, Nuclear Safety, 18N2, 154167
  2. 2. ChangS. H.LeeK. W.GroeneveldD. C.1989Transient-Effects Modelling of Critical Heat Flux, Nucl. Eng. Design, 1135157
  3. 3. CelataG. P.CumoM.D’annibaleF.FarelloG. E.MarianiA.1991CHF Behavior During Pressure, Power and/or Flow Rate Simultaneous Variations, Int. J. Heat Mass Transfer, 34(3). 723738
  4. 4. CelataG. P.CumaM.MarianiA.SimosiniM.ZummoG.1994Rationalization of Existing Mechanistic Models for the Prediction of Water Subcooled Flow Boiling Critical Heat FluxInt. J. Heat and Mass Transfer 37Suppl. 1, 347360
  5. 5. ChenY.ZhouR.ChenH.1996Critical Heat Flux for Subcooled Flow in an Annulus with Bilateral Heating, in Heat Transfer and Technology 1996, Bu-xuan Wang, Higher Education. Press, 7-04005-894-4376381
  6. 6. ChenY.ZhouR.HaoL.ChenH.1997Critical Heat Flux with Subcooled Boiling of Water at Low Pressure, Proc. 8th Int. Topical Meeting on Nuclear Reactor Thermal-Hydraulics, 1997, Japan, 2958964
  7. 7. ChenY.ZhangH.GuoF.HaoL.2000Subcooled Flow Boiling CHF in Tubes with Different Diameters, Presented at Boiling 2000, Alaska
  8. 8. ChenY.ZouL.YangC.2004Subcooled Critical Heat Flux in Annuli at Lower Pressure, Proc. NUTHOS-5, Japan
  9. 9. ChenY.YangC.MaoY.2005An Experimental Study of Subcooled Flow Boiling Critical Heat Flux of Water under Steady-State and Flow-Transient Conditions at Lower Pressure, Proc. 11th Int. Topical Meeting on Nuclear Reactor Thermal-Hydraulics (NURETH-11), Avignon, France
  10. 10. ChenY.YangC.ZhaoM.BiK.DuK.ZhangS.2011Subcooled Boiling Critical Heat Flux of Water Flowing Upward in a Tube for Lower Flow and Pressure up to 20 MPa, Proc. 14th Int. Topical Meeting on Nuclear Reactor Thermal Hydraulics (NURETH-14), LN-620
  11. 11. GambillW. R.1963Generalized Prediction of Burnout Heat Flux for Flowing Subcooled Wetting Liquids, Chem. Eng. Prog. Sump. Series, 5941
  12. 12. GroeneveldD. C.et al.1996The 1996 Look-up Table for Critical Heat Flux in Tubes, Nuclear Eng. Design 163123
  13. 13. GuntherF. C.1951Photographic Study of Surface Boiling Heat Transfer to Water with Forced Convection, Trans. ASME, 73115
  14. 14. IwamuraT.1987Transient Burnout Under Rapid Flow Reduction ConditionJ. Nucl. Sci. and Tech. 24811820
  15. 15. IwamuraT.WatanabeH.MuraoY.1994Critical Heat Flux Experiments under Steady-state and Transient Conditions and Visualization of CHF Phenomenon with Neutron RadiographyNuclear Engineering and Design 149195206
  16. 16. KattoY.1992A Prediction Model of Subcooled Water Flow Boiling CHF for Pressures in the region 0.1-20.0 MPa, Int. J. Heat ans Mass Transfer, 3511151123
  17. 17. KlausnerJ. F.MeiR.BernhardD. M.ZengL. Z.1993Vapor Bubble Departure in Forced Convection BoilingInt. J. Heat Mass Transfer, 36651662
  18. 18. KnoebelD. H.HarrisS. D.CrainB.1973Forced Convection Subcooled Critical Heat Flux, D2O and H2O Coolant with Aluminum and Stainless-Steel Heaters, DP- 1306
  19. 19. LevyS.1967Turbulent Flow in an AnnulusTrans. ASME, C, J. Heat Transfer, 892531
  20. 20. LeeC. H.MudawarI.1983A Mechanistic Critical Heat Flux Model for Subcooled Flow Boiling Based on Local Bulk Flow ConditionsInt. J. Multiphase Flow, 14711728
  21. 21. LeungJ. C. M.1978CHF under Transient Conditions: a Literature survey," NURETH/CP-0056
  22. 22. MartinelliR. C.1947Heat Transfer to Molter Metals”, Trans. ASME 69947951
  23. 23. MirshakS.DurantW. S.TowellR. H.1959Heat Flux at BurnoutDP- 355
  24. 24. MoonS. K.ChunS. Y.ChoiK. Y.BaekW. P.2002Transient Critical Heat Flux Under Flow Coastdown in a Vertical Annulus With Non-Uniform Heat Flux Distribution, J. Korea Nuclear Science, 34382395
  25. 25. Siman-TovM.FeldeD. K.Mc DuffeeJ. L.Yoder JrG. L.1995Static Flow-instability in Subcooled Flow Boiling in Wide Rectangular Parallel Channels, 2nd Int. Conf. on Multi-phase Flow, Japan
  26. 26. StaubF. W.1968The Void Fraction in Subcooled Boiling- Prediction of the initial Point of Net Vapor Generation, J. Heat Transfer, 90151157
  27. 27. SudoY.KaminagaM.1993A New CHF Correlation Scheme Proposed for Vertical Rectangular Channels Heated From Both Sides in Nuclear Research ReactorsASME, C. 115426434
  28. 28. Thermohydraulic relationships for advanced water cooled reactors2001IAEA-TECDOC-1203
  29. 29. ThorogersonE. J.KnoebelD. H.GibbonsJ. H.1974A Model to Predict Convective Subcooled Critical Heat Flux," Trans. ASME, J. Heat Transfer, 967982
  30. 30. TongL. S.1968Boundary Layer Analysis of the Flow Boiling Crisis, Int. J. Heat Mass Transfer, 1112081211
  31. 31. TongL. S.1967Prediction of Departure from Nucleate Boiling for An Axially Non-Uniform Heat Distribution, Journal Nuclear Energy, 21
  32. 32. TongL. S.TangY. S.1997Boiling Heat Transfer and Two-Phase FlowTaylor & Francis Pub., 1-56032-485-6
  33. 33. WeismanJ.PeiB. S.1983Prediction of Critical Heat Flux in Flow Boiling at low qualitiesIntJ. Heat Mass Transfer, 2614631477
  34. 34. WeismanJ.1995A Phenomenological Explanation of the Relationship Between Steady State and Transient CHF at Subcooled or low Quality ConditionsNucl. Eng. and Des. 158157160
  35. 35. XuG.atal. (1979Heat Transfer and Pressure Drop in an Annulus with Subcooled Boiling Water, Analysis and Experiment of Reactor Thermohydraulics, Atomic Energy Press, 412417in Chinese)
  36. 36. ZeigarnikYu. A.1994Critical Heat Flux with Boiling of Subcooled Water in Rectangular Channels with One Sided Supply of HeatThermal Engineering, 2840

Written By

Yuzhou Chen

Submitted: 01 December 2011 Published: 31 October 2012